Jayant Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jayant Sharma has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Chinnayan Karuppaiyah Sundarabalan
School of Electrical and Electronics Engineering, SASTRA Deemed University, Thanjavur, India
9 shared publications - Balasundar Chelladurai
School of Electrical and Electronics Engineering, SASTRA Deemed University, Thanjavur, India
4 shared publications - Josep Maria Guerrero
Zhejiang University
4 shared publications - Srinath Nangavaram Santhanam
School of Electrical and Electronics Engineering, SASTRA Deemed University, Thanjavur, India
4 shared publications C. Balasundar
2 shared publications- Hari Venkadesh Ramamoorthi
School of Electrical and Electronics Engineering, SASTRA Deemed University, Thanjavur, India
2 shared publications
Latest Publications
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (3) , 4447-4458
Gaussian Process Regression and Linear Degradation-Based RUL Prediction of DC-Link Capacitors in Electric Aircraft Powertrains
In modern electric aircraft, DC-link capacitors are critical for voltage regulation in power converters, directly affecting the reliability and performance of onboard electrical systems. Accurate prediction of capacitor degradation is essential for proactive maintenance and fault prevention. This article investigates the remaining useful life (RUL) prediction of 270 V DC-link capacitors in electric aircraft powertrains using two distinct methods, linear degradation modeling (LDM) and Gaussian process regression (GPR). Diagnostic features are extracted from simulated voltage waveforms representing extended flight operations, and a health indicator (HI) is constructed to quantify capacitor aging. The LDM provides incremental RUL estimation with confidence intervals, while GPR captures nonlinear degradation patterns and associated uncertainties, achieving higher prediction performance compared to LDM. Real-time validation is conducted using a dSPACE 1202 processor under different flight phases, coordinated by an energy management centre (EMC) compliant with MIL-STD-704F standards. Comparative results demonstrate the superior performance of GPR, enabling informed decisions for intelligent energy management and maintenance in aircraft power systems.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (3) , 4447-4458
Gaussian Process Regression and Linear Degradation-Based RUL Prediction of DC-Link Capacitors in Electric Aircraft Powertrains
In modern electric aircraft, DC-link capacitors are critical for voltage regulation in power converters, directly affecting the reliability and performance of onboard electrical systems. Accurate prediction of capacitor degradation is essential for proactive maintenance and fault prevention. This article investigates the remaining useful life (RUL) prediction of 270 V DC-link capacitors in electric aircraft powertrains using two distinct methods, linear degradation modeling (LDM) and Gaussian process regression (GPR). Diagnostic features are extracted from simulated voltage waveforms representing extended flight operations, and a health indicator (HI) is constructed to quantify capacitor aging. The LDM provides incremental RUL estimation with confidence intervals, while GPR captures nonlinear degradation patterns and associated uncertainties, achieving higher prediction performance compared to LDM. Real-time validation is conducted using a dSPACE 1202 processor under different flight phases, coordinated by an energy management centre (EMC) compliant with MIL-STD-704F standards. Comparative results demonstrate the superior performance of GPR, enabling informed decisions for intelligent energy management and maintenance in aircraft power systems.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (4) , 5206-5216
Conjugate-Gradient Based Control in a Grid-Integrated PV With 24/7 Distortion-Free Charging for Bidirectional EV Charger
Plug-in electric vehicles (EVs) are viewed as a step forward in the electrification of transportation, replacing conventional vehicles powered by internal combustion engines. However, to provide consistent and efficient charging, the EV charging infrastructure needs to be developed, which is capable of delivering distortion-free grid supply, even in the absence of renewable energy resources. This article presents an application of a grid-connected EV charger supplied by a grid-connected solar photovoltaic array that provides 24/7 distortion-free charging. The bidirectional charging system includes an EV battery connected to the dc bus; an independent solar-PV source connected to the ac grid through a bifunctional voltage source converter. A new conjugate gradient based adaptive control algorithm is implemented for the voltage source converter control. Real-time analysis is done using dSPACE 1202 processor. The proposed system is validated to maintain IEEE-519 standards.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (4) , 5206-5216
Conjugate-Gradient Based Control in a Grid-Integrated PV With 24/7 Distortion-Free Charging for Bidirectional EV Charger
Plug-in electric vehicles (EVs) are viewed as a step forward in the electrification of transportation, replacing conventional vehicles powered by internal combustion engines. However, to provide consistent and efficient charging, the EV charging infrastructure needs to be developed, which is capable of delivering distortion-free grid supply, even in the absence of renewable energy resources. This article presents an application of a grid-connected EV charger supplied by a grid-connected solar photovoltaic array that provides 24/7 distortion-free charging. The bidirectional charging system includes an EV battery connected to the dc bus; an independent solar-PV source connected to the ac grid through a bifunctional voltage source converter. A new conjugate gradient based adaptive control algorithm is implemented for the voltage source converter control. Real-time analysis is done using dSPACE 1202 processor. The proposed system is validated to maintain IEEE-519 standards.
- 4 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 19 (6) , 7583-7591
Mixed Step Size Normalized Least Mean Fourth Algorithm of DSTATCOM Integrated Electric Vehicle Charging Station
The growth of electric vehicle loads increases the harmonics in the distribution grid. This article proposes a mixed step size normalized least mean fourth control algorithm (MSSNLMF) of distribution static compensator to alleviate the harmonics in the electric vehicles connected distribution grid. The overall system comprises bidirectional ac–dc, dc–dc converters, and distribution static compensator. The bidirectional converters are employed to achieve the vehicle to grid and grid to vehicle operations. A lithium-ion battery is utilized as an electric vehicle energy storage device. An adaptive MSSNLMF control algorithm is proposed to extract active and reactive power signals from the distorted load current to obtain the reference source currents. This algorithm combines the least mean fourth and normalized least mean fourth algorithms with mixed step size. The performance of the control algorithm is evaluated in the MATLAB/Simulink environment. It is experimentally verified through the real time simulation using the dSPACE (DS1202) real-time processor. The proposed MSSNLMF algorithm performs well in the DSTATCOM dc-link voltage regulation and reduction of total harmonic distortion. The source current total harmonic distortion is maintained below the allowable limit of IEEE 519-2014 standard.
- 4 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 19 (6) , 7583-7591
Mixed Step Size Normalized Least Mean Fourth Algorithm of DSTATCOM Integrated Electric Vehicle Charging Station
The growth of electric vehicle loads increases the harmonics in the distribution grid. This article proposes a mixed step size normalized least mean fourth control algorithm (MSSNLMF) of distribution static compensator to alleviate the harmonics in the electric vehicles connected distribution grid. The overall system comprises bidirectional ac–dc, dc–dc converters, and distribution static compensator. The bidirectional converters are employed to achieve the vehicle to grid and grid to vehicle operations. A lithium-ion battery is utilized as an electric vehicle energy storage device. An adaptive MSSNLMF control algorithm is proposed to extract active and reactive power signals from the distorted load current to obtain the reference source currents. This algorithm combines the least mean fourth and normalized least mean fourth algorithms with mixed step size. The performance of the control algorithm is evaluated in the MATLAB/Simulink environment. It is experimentally verified through the real time simulation using the dSPACE (DS1202) real-time processor. The proposed MSSNLMF algorithm performs well in the DSTATCOM dc-link voltage regulation and reduction of total harmonic distortion. The source current total harmonic distortion is maintained below the allowable limit of IEEE 519-2014 standard.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (2) , 2469-2478
Effect of Fault Ride Through Capability on Electric Vehicle Charging Station Under Critical Voltage Conditions
A high-quality power supply is required for the proper functioning of the electric vehicle (EV) charging system. However, the voltage quality is one of the significant issues in the distribution grid. This article aims to examine the impacts of voltage disturbance on EV batteries and charging systems, and provides a fault ride-through capability (FRTC) to enhance the voltage quality. The charging system is constructed by the three-phase controlled rectifier and the dc–dc converter. The EV battery pack is modeled with lithium-ion batteries. The FRTC system is designed to improve the voltage quality, and it is achieved through the dynamic voltage restorer. It protects the EV batteries and charging system from the critical voltage sag levels. The performance of the proposed EV charging station (EVCS) has been investigated in 30%, 60%, and 90% voltage sag through the MATLAB/Simulink platform. Also, the real-time validation has been carried out by the software-in-the-loop test with the help of the dSPACE (DS1202) real-time system. The EVCS with an FRTC system provides better performance than the conventional EVCS.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 8 (2) , 2469-2478
Effect of Fault Ride Through Capability on Electric Vehicle Charging Station Under Critical Voltage Conditions
A high-quality power supply is required for the proper functioning of the electric vehicle (EV) charging system. However, the voltage quality is one of the significant issues in the distribution grid. This article aims to examine the impacts of voltage disturbance on EV batteries and charging systems, and provides a fault ride-through capability (FRTC) to enhance the voltage quality. The charging system is constructed by the three-phase controlled rectifier and the dc–dc converter. The EV battery pack is modeled with lithium-ion batteries. The FRTC system is designed to improve the voltage quality, and it is achieved through the dynamic voltage restorer. It protects the EV batteries and charging system from the critical voltage sag levels. The performance of the proposed EV charging station (EVCS) has been investigated in 30%, 60%, and 90% voltage sag through the MATLAB/Simulink platform. Also, the real-time validation has been carried out by the software-in-the-loop test with the help of the dSPACE (DS1202) real-time system. The EVCS with an FRTC system provides better performance than the conventional EVCS.
- Open Access
- 12 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 59888-59899
Power Quality Enhancement in Sensitive Local Distribution Grid Using Interval Type-II Fuzzy Logic Controlled DSTATCOM
In the current scenario, integration of renewables, growth of non-linear industrial and commercial loads results in various power quality issues. Among commercial utilities connected to the grid, hospital-operated loads include sensitive, linear, non-linear, and unbalanced loads. These loads are diverse as well as prioritized, which also causes major power quality issues in the local distribution system. Due to its widespread divergence, it leads to harmonic injection and reactive power imbalance. Distribution Static Compensator (DSTATCOM) is proposed as a solution for harmonic mitigation, load balancing, reactive power imbalances, and neutral current compensation. The present work utilizes Interval Type-2 Fuzzy Logic Controller (IT2FLC) with Recursive Least Square (RLS) filter for generating switching pulses for IGBT switches in the DSTATCOM to improve power quality in the Local Distribution Grid. The proposed approach also shows superior performance over Type 1 fuzzy logic controller and Conventional PI controller in mitigating harmonics. For effective realization, the proposed system is simulated using MATLAB software.
- 12 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 59888-59899
Open AccessPower Quality Enhancement in Sensitive Local Distribution Grid Using Interval Type-II Fuzzy Logic Controlled DSTATCOM
In the current scenario, integration of renewables, growth of non-linear industrial and commercial loads results in various power quality issues. Among commercial utilities connected to the grid, hospital-operated loads include sensitive, linear, non-linear, and unbalanced loads. These loads are diverse as well as prioritized, which also causes major power quality issues in the local distribution system. Due to its widespread divergence, it leads to harmonic injection and reactive power imbalance. Distribution Static Compensator (DSTATCOM) is proposed as a solution for harmonic mitigation, load balancing, reactive power imbalances, and neutral current compensation. The present work utilizes Interval Type-2 Fuzzy Logic Controller (IT2FLC) with Recursive Least Square (RLS) filter for generating switching pulses for IGBT switches in the DSTATCOM to improve power quality in the Local Distribution Grid. The proposed approach also shows superior performance over Type 1 fuzzy logic controller and Conventional PI controller in mitigating harmonics. For effective realization, the proposed system is simulated using MATLAB software.
- Open Access
- 18 April 2020
- Published by MDPI AG in Electronics
- Vol. 9 (4) , 662
Novel Exertion of Intelligent Static Compensator Based Smart Inverters for Ancillary Services in a Distribution Utility Network-Review
Integration of distributed energy resources (DER) has always posed a challenge. Smart inverters have started playing a crucial role in efficient integration of DERs. With the basic functionalities of traditional inverters in place, smart inverters can provide grids with related ancillary services either from the customer side or from the utility as well. The ancillary/augmented service from smart inverters includes the concept of reactive power exchange with the grid. Such grid support functions includes the functionalities of photovoltaic/plug in electric vehicles (PV/PEV) inverters as a static synchronous compensators (STATCOMs) by performing virtual detuning, temporary over voltage (TOV) mitigation, voltage regulation, frequency support and ride through capabilities. As the penetration levels of DERs have gone up, the need for such ancillary services has grown as well. This paper is organized in such a way that it will serve as a benchmark for smart inverter technologies in the form of a review. It includes several domains involving the applications, advanced and coordinated control, topologies and many more aspects that are associated with smart inverters based on reactive power compensation schemes for ancillary services. Apart from that, the applications those are associated with smart inverters in the smart grid domain are also highlighted in this paper.
- 18 April 2020
- Published by MDPI AG in Electronics
- Vol. 9 (4) , 662
Open AccessNovel Exertion of Intelligent Static Compensator Based Smart Inverters for Ancillary Services in a Distribution Utility Network-Review
Integration of distributed energy resources (DER) has always posed a challenge. Smart inverters have started playing a crucial role in efficient integration of DERs. With the basic functionalities of traditional inverters in place, smart inverters can provide grids with related ancillary services either from the customer side or from the utility as well. The ancillary/augmented service from smart inverters includes the concept of reactive power exchange with the grid. Such grid support functions includes the functionalities of photovoltaic/plug in electric vehicles (PV/PEV) inverters as a static synchronous compensators (STATCOMs) by performing virtual detuning, temporary over voltage (TOV) mitigation, voltage regulation, frequency support and ride through capabilities. As the penetration levels of DERs have gone up, the need for such ancillary services has grown as well. This paper is organized in such a way that it will serve as a benchmark for smart inverter technologies in the form of a review. It includes several domains involving the applications, advanced and coordinated control, topologies and many more aspects that are associated with smart inverters based on reactive power compensation schemes for ancillary services. Apart from that, the applications those are associated with smart inverters in the smart grid domain are also highlighted in this paper.