Elisa Matarazzo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Elisa Matarazzo has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Arianna Pani
Department of Oncology and Hemato-oncology, University of Milan, Milan, Italy
1 shared publication - Carlo Federico Perno
Microbiology and Diagnostic Immunology Unit, Bambino Gesù Children’s Hospital, IRCCS, 00165 Rome, Italy
1 shared publication - Chiara Vismara
Division of Clinical Microbiology, ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy
1 shared publication - Claudia Alteri
Microbiology and Virology Unit, Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milan, Italy
1 shared publication - Diana Fanti
Division of Clinical Microbiology, ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy
1 shared publication - Federica Di Ruscio
Residency in Microbiology and Virology, Università degli Studi di Milano, 20122 Milan, Italy
1 shared publication
Latest Publications
- Open Access
Frontline Screening for SARS-CoV-2 Infection at Emergency Department Admission by Third Generation Rapid Antigen Test: Can We Spare RT-qPCR?
To complement RT-qPCR testing for diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections, many countries have introduced the use of rapid antigen tests. As they generally display lower real-life performances than expected, their correct positioning as frontline screening is still controversial. Despite the lack of data from daily clinical use, third generation microfluidic assays (such as the LumiraDx SARS-CoV-2 Ag test) have recently been suggested to have similar performances to RT-qPCR and have been proposed as alternative diagnostic tools. By analyzing 960 nasopharyngeal swabs from 960 subjects at the emergency department admissions of a tertiary COVID-19 hospital, LumiraDx assay demonstrated a specificity of 97% (95% CI: 96–98), and a sensitivity of 85% (95% CI: 82–89) in comparison with RT-qPCR, which increases to 91% (95% CI: 86–95) for samples with a cycle threshold ≤ 29. Fifty false-negative LumiraDx-results were confirmed by direct quantification of genomic SARS-CoV-2 RNA through droplet-digital PCR (median (IQR) load = 5880 (1657–41,440) copies/mL). Subgenomic N and E RNAs were detected in 52% (n = 26) and 56% (n = 28) of them, respectively, supporting the presence of active viral replication. Overall, the LumiraDx test complies with the minimum performance requirements of the WHO. Yet, the risk of a misrecognition of patients with active COVID-19 persists, and the need for confirmatory RT-qPCR should not be amended.
Open AccessFrontline Screening for SARS-CoV-2 Infection at Emergency Department Admission by Third Generation Rapid Antigen Test: Can We Spare RT-qPCR?
To complement RT-qPCR testing for diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections, many countries have introduced the use of rapid antigen tests. As they generally display lower real-life performances than expected, their correct positioning as frontline screening is still controversial. Despite the lack of data from daily clinical use, third generation microfluidic assays (such as the LumiraDx SARS-CoV-2 Ag test) have recently been suggested to have similar performances to RT-qPCR and have been proposed as alternative diagnostic tools. By analyzing 960 nasopharyngeal swabs from 960 subjects at the emergency department admissions of a tertiary COVID-19 hospital, LumiraDx assay demonstrated a specificity of 97% (95% CI: 96–98), and a sensitivity of 85% (95% CI: 82–89) in comparison with RT-qPCR, which increases to 91% (95% CI: 86–95) for samples with a cycle threshold ≤ 29. Fifty false-negative LumiraDx-results were confirmed by direct quantification of genomic SARS-CoV-2 RNA through droplet-digital PCR (median (IQR) load = 5880 (1657–41,440) copies/mL). Subgenomic N and E RNAs were detected in 52% (n = 26) and 56% (n = 28) of them, respectively, supporting the presence of active viral replication. Overall, the LumiraDx test complies with the minimum performance requirements of the WHO. Yet, the risk of a misrecognition of patients with active COVID-19 persists, and the need for confirmatory RT-qPCR should not be amended.