Tsuyoshi Kawakami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tsuyoshi Kawakami has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Kazuo Isama
Faculty of Pharmaceutical Sciences, Teikyo Heisei University, Tokyo, Japan
15 shared publicationsYoshiaki Ikarashi
National Institute of Health Sciences
14 shared publications- Maiko Tahara
Division of Environmental Chemistry, National Institute of Health Sciences
8 shared publications Maiko Tahara
National Institute of Health Sciences
6 shared publicationsAtsuko Matsuoka
National Institute of Health Sciences
4 shared publicationsTomoko Ooshima
Osaka Institute of Public Health
4 shared publications
Latest Publications
- 22 March 2026
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- p. 1-7
Analysis of isothiazolinones and other preservatives in leather, synthetic leather, and textile products available in Japan
Isothiazolinones are heterocyclic organic compounds composed of five-membered rings. Owing to their potent antimicrobial properties, they are widely used in cosmetics,[1] detergents,[2] household d...
- 22 March 2026
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- p. 1-7
Analysis of isothiazolinones and other preservatives in leather, synthetic leather, and textile products available in Japan
Isothiazolinones are heterocyclic organic compounds composed of five-membered rings. Owing to their potent antimicrobial properties, they are widely used in cosmetics,[1] detergents,[2] household d...
- 3 August 2025
- Published by Wiley in Contact Dermatitis
- Vol. 93 (5) , 390-397
Occupational Allergic Contact Dermatitis Caused by Mercaptobenzothiazole in DS2 Dust Mask Straps During the COVID ‐19 Pandemic: A Study of Outbreak and Proposal of Safer Alternatives
Background: The global COVID‐19 pandemic has necessitated the widespread use of dust masks, including N95 and DS2, in healthcare settings. Although allergic contact dermatitis caused by dust mask straps has been reported, component analysis of the straps is rare. We encountered an outbreak of dermatitis cases due to rubber straps of a DS2 mask (Mask A) at our hospital. Objectives: To investigate the cause of dermatitis associated with Mask A rubber strap, identify the allergens responsible for allergic contact dermatitis and propose suitable alternative masks. Patients/Methods: Twelve healthcare workers who developed contact dermatitis after wearing Mask A were enrolled. A detailed questionnaire, chemical analyses of Mask A rubber straps and alternatives and patch testing with identified components of the straps were performed. Results: Twelve cases (nine females, three males; mean age 47.8 ± 11.1 years) had no prior history of contact rubber allergy. The straps of Mask A contained thiazole‐type vulcanisation accelerators and degradation products. Patch testing revealed sensitisation to 2‐mercaptobenzothiazole, 2,2′‐dithiobis(benzothiazole) and 2‐(methylthio)benzothiazole in eight, three and five cases, respectively. Conclusion: Occupational allergic contact dermatitis due to 2‐mercaptobenzothiazole in Mask A straps was diagnosed in eight cases. All affected individuals successfully switched to alternative masks without recurrence.
- 3 August 2025
- Published by Wiley in Contact Dermatitis
- Vol. 93 (5) , 390-397
Occupational Allergic Contact Dermatitis Caused by Mercaptobenzothiazole in DS2 Dust Mask Straps During the COVID ‐19 Pandemic: A Study of Outbreak and Proposal of Safer Alternatives
Background: The global COVID‐19 pandemic has necessitated the widespread use of dust masks, including N95 and DS2, in healthcare settings. Although allergic contact dermatitis caused by dust mask straps has been reported, component analysis of the straps is rare. We encountered an outbreak of dermatitis cases due to rubber straps of a DS2 mask (Mask A) at our hospital. Objectives: To investigate the cause of dermatitis associated with Mask A rubber strap, identify the allergens responsible for allergic contact dermatitis and propose suitable alternative masks. Patients/Methods: Twelve healthcare workers who developed contact dermatitis after wearing Mask A were enrolled. A detailed questionnaire, chemical analyses of Mask A rubber straps and alternatives and patch testing with identified components of the straps were performed. Results: Twelve cases (nine females, three males; mean age 47.8 ± 11.1 years) had no prior history of contact rubber allergy. The straps of Mask A contained thiazole‐type vulcanisation accelerators and degradation products. Patch testing revealed sensitisation to 2‐mercaptobenzothiazole, 2,2′‐dithiobis(benzothiazole) and 2‐(methylthio)benzothiazole in eight, three and five cases, respectively. Conclusion: Occupational allergic contact dermatitis due to 2‐mercaptobenzothiazole in Mask A straps was diagnosed in eight cases. All affected individuals successfully switched to alternative masks without recurrence.
- 25 February 2025
- Published by Wiley in Contact Dermatitis
- Vol. 92 (6) , 493-496
Concomitant Reactions Among Rosin‐Related Compounds in Five Cases of Allergic Contact Dermatitis Caused by Glyceryl Hydrogenated Rosinate
- 25 February 2025
- Published by Wiley in Contact Dermatitis
- Vol. 92 (6) , 493-496
Concomitant Reactions Among Rosin‐Related Compounds in Five Cases of Allergic Contact Dermatitis Caused by Glyceryl Hydrogenated Rosinate
- 23 February 2025
- Published by Elsevier in Chemosphere
- Vol. 375, 144247
Identification of an aryl hydrocarbon receptor agonistic disperse dye in commercially available textile products by effect-directed analysis
- 23 February 2025
- Published by Elsevier in Chemosphere
- Vol. 375, 144247
Identification of an aryl hydrocarbon receptor agonistic disperse dye in commercially available textile products by effect-directed analysis
- 20 May 2024
- Published by Wiley in Contact Dermatitis
- Vol. 91 (3) , 264-266
Allergic contact dermatitis caused by menthoxypropanediol in a skin care lotion
- 20 May 2024
- Published by Wiley in Contact Dermatitis
- Vol. 91 (3) , 264-266
Allergic contact dermatitis caused by menthoxypropanediol in a skin care lotion
- Open Access
- 1 April 2024
- Published by Pharmaceutical Society of Japan in YAKUGAKU ZASSHI
- Vol. 144 (4) , 463-471
有害物質を含有する家庭用品の規制に関する法律(有害物質含有家庭用品規制法)におけるトリス(2,3-ジブロムプロピル)ホスフェイト(TDBPP)及びビス(2,3-ジブロムプロピル)ホスフェイト(BDBPP)化合物試験法改定に係わる検討
In Japan, the use of frame retardants [tris(2,3-dibromopropyl)phosphate: TDBPP and bis(2,3-dibromopropyl)phosphate: BDBPP] in several household textile products is banned under the “Act on the Control of Household Products Containing Harmful Substances.” As the official analytical methods for testing these substances have not been revised for over 42 years, several issues such as the using of harmful reagents, have been pointed out. Therefore, we developed a new method to revise the official method in our previous study. In this study, the validity of the developed test method is evaluated at six laboratories using two types of textile samples spiked with TDBPP and BDBPP at three concentrations (4, 8, and 20 µg/g). TDBPP and BDBPP are extracted under reflux using methanol containing hydrochloric acid. TDBPP is analyzed using GC-MS, and BDBPP is also analyzed using GC-MS after methylation with trimethylsilyl diazomethane. Although the accuracy (70–120%), repeatability (<10%), and reproducibility (<15%) of a few samples, mainly low concentration samples, are out of range, overall, the concentration level of detection limits of TDBPP and BDBPP (8 and 10 µg/g) in official analytical methods are quantifiable with sufficient precision using the proposed method. Furthermore, harmful reagents are not used in this method. Thus, the method validated in this study is effective as a revised method for the testing of TDBPP and BDBPP in household textile products.
- 1 April 2024
- Published by Pharmaceutical Society of Japan in YAKUGAKU ZASSHI
- Vol. 144 (4) , 463-471
Open Access有害物質を含有する家庭用品の規制に関する法律(有害物質含有家庭用品規制法)におけるトリス(2,3-ジブロムプロピル)ホスフェイト(TDBPP)及びビス(2,3-ジブロムプロピル)ホスフェイト(BDBPP)化合物試験法改定に係わる検討
In Japan, the use of frame retardants [tris(2,3-dibromopropyl)phosphate: TDBPP and bis(2,3-dibromopropyl)phosphate: BDBPP] in several household textile products is banned under the “Act on the Control of Household Products Containing Harmful Substances.” As the official analytical methods for testing these substances have not been revised for over 42 years, several issues such as the using of harmful reagents, have been pointed out. Therefore, we developed a new method to revise the official method in our previous study. In this study, the validity of the developed test method is evaluated at six laboratories using two types of textile samples spiked with TDBPP and BDBPP at three concentrations (4, 8, and 20 µg/g). TDBPP and BDBPP are extracted under reflux using methanol containing hydrochloric acid. TDBPP is analyzed using GC-MS, and BDBPP is also analyzed using GC-MS after methylation with trimethylsilyl diazomethane. Although the accuracy (70–120%), repeatability (<10%), and reproducibility (<15%) of a few samples, mainly low concentration samples, are out of range, overall, the concentration level of detection limits of TDBPP and BDBPP (8 and 10 µg/g) in official analytical methods are quantifiable with sufficient precision using the proposed method. Furthermore, harmful reagents are not used in this method. Thus, the method validated in this study is effective as a revised method for the testing of TDBPP and BDBPP in household textile products.
- 28 September 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (1) , 61-68
GC-MS Analysis of Primary Aromatic Amines Originated From Azo Dyes in Commercial Textile or Leather Products Using Helium Alternative Carrier Gases
Background: In recent years, due to the global shortage of helium gas, the development of gas chromatography (GC) analytical methods using alternatives to helium carrier gases is necessary. Objective: The objective of this study was to examine the applicability of hydrogen and nitrogen as alternative carrier gases using the test method for azo compounds in the Act on Control of Household Products Containing Harmful Substances of Japan. Method: The gas chromatograph mass spectrometer (GC-MS) analytical method using hydrogen and nitrogen as alternative carrier gases was compared with a method using helium for 26 primary aromatic amines (PAAs) originated from azo dyes. Results: When hydrogen and nitrogen were used as carrier gases under the same conditions used during analysis using helium (same column, gas flow rate, oven temperature conditions, etc.), sufficient peak separation of 26 PAAs was obtained. The sensitivities of the methods using helium and hydrogen were comparable, whereas the sensitivity was lower when nitrogen was used, with the detection limits ranging from 1/220 to 1/25. However, all carrier gases achieved quantification at concentrations below the standard value (30 μg/g) of the Act on Control of Household Products Containing Harmful Substances, and the results were in agreement with the standard value for the target product. Conclusions: Our results indicated that hydrogen or nitrogen can be used as alternative carrier gases to helium for GC-MS analysis of azo compounds producing specific aromatic amines. Highlights: Using hydrogen or nitrogen as an alternative carrier gas to helium, azo compounds could be quantified with excellent accuracy.
- 28 September 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (1) , 61-68
GC-MS Analysis of Primary Aromatic Amines Originated From Azo Dyes in Commercial Textile or Leather Products Using Helium Alternative Carrier Gases
Background: In recent years, due to the global shortage of helium gas, the development of gas chromatography (GC) analytical methods using alternatives to helium carrier gases is necessary. Objective: The objective of this study was to examine the applicability of hydrogen and nitrogen as alternative carrier gases using the test method for azo compounds in the Act on Control of Household Products Containing Harmful Substances of Japan. Method: The gas chromatograph mass spectrometer (GC-MS) analytical method using hydrogen and nitrogen as alternative carrier gases was compared with a method using helium for 26 primary aromatic amines (PAAs) originated from azo dyes. Results: When hydrogen and nitrogen were used as carrier gases under the same conditions used during analysis using helium (same column, gas flow rate, oven temperature conditions, etc.), sufficient peak separation of 26 PAAs was obtained. The sensitivities of the methods using helium and hydrogen were comparable, whereas the sensitivity was lower when nitrogen was used, with the detection limits ranging from 1/220 to 1/25. However, all carrier gases achieved quantification at concentrations below the standard value (30 μg/g) of the Act on Control of Household Products Containing Harmful Substances, and the results were in agreement with the standard value for the target product. Conclusions: Our results indicated that hydrogen or nitrogen can be used as alternative carrier gases to helium for GC-MS analysis of azo compounds producing specific aromatic amines. Highlights: Using hydrogen or nitrogen as an alternative carrier gas to helium, azo compounds could be quantified with excellent accuracy.
- 20 April 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1698, 464007
Development of a safer and improved analytical method for polycyclic aromatic hydrocarbons in creosote products
- 20 April 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1698, 464007
Development of a safer and improved analytical method for polycyclic aromatic hydrocarbons in creosote products
- 31 October 2022
- Published by American Chemical Society (ACS) in Chemical Research in Toxicology
- Vol. 35 (11) , 2107-2121
Theoretical Validation of In Chemico Skin Sensitization Assay “ADRA” Using the Products Formed by Nucleophilic Reagents and Chemicals
Amino acid derivative reactivity assay (ADRA) is an in chemico assay for assessing the skin sensitization potential of chemicals by evaluating the reactivity of nucleophilic reagents that mimic skin proteins. N-(2-(1-Naphthyl)acetyl)-l-cysteine (NAC) and α-N-(2-(1-naphthyl)acetyl)-l-lysine (NAL), used as nucleophilic reagents, are small-molecule derivatives of two different amino acids, each with a naphthalene ring attached. The rate of decrease in the amount of NAC or NAL in the reaction solution is evaluated in this assay as an indicator of the test substance's skin sensitization ability. However, the products formed between the nucleophilic reagent and the test substance, which play an important role in vivo, are not directly identified. Therefore, six highly reactive chemicals, including the proficiency substances listed in the OECD Test Guidelines─squaric acid diethyl ester, 2-methyl-2H-isothiazol-3-one (MI), p-benzoquinone, palmitoyl chloride, diphenylcyclopropenone (DPCP), and imidazolidinyl urea (IU)─were used to determine each formed product. Samples were prepared according to the standard ADRA method, and the formed products were predicted on the basis of the reaction mechanism. Excluding DPCP, the estimated structures were validated using mass spectrometry and nuclear magnetic resonance spectrometry on the synthesized samples. In this manner, the products of each nucleophile were confirmed for all examined test substances. The estimated structure products were obtained through a series of reactions initiated by the nucleophilic attack of NAC's thiol group or NAL's amino group on the test substance's electron-deficient carbonyl carbon. However, contrary to expectations, disulfide-linked-type ring-opened products were detected in the case of MI, and products with free formaldehyde in solution were detected in the case of IU. In summary, all skin sensitizers tested herein reacted with NAC and/or NAL to give products. This supports the theoretical validity of ADRA, which provides an indirect evaluation of the formed products based on a decrease in nucleophilic reagents.
- 31 October 2022
- Published by American Chemical Society (ACS) in Chemical Research in Toxicology
- Vol. 35 (11) , 2107-2121
Theoretical Validation of In Chemico Skin Sensitization Assay “ADRA” Using the Products Formed by Nucleophilic Reagents and Chemicals
Amino acid derivative reactivity assay (ADRA) is an in chemico assay for assessing the skin sensitization potential of chemicals by evaluating the reactivity of nucleophilic reagents that mimic skin proteins. N-(2-(1-Naphthyl)acetyl)-l-cysteine (NAC) and α-N-(2-(1-naphthyl)acetyl)-l-lysine (NAL), used as nucleophilic reagents, are small-molecule derivatives of two different amino acids, each with a naphthalene ring attached. The rate of decrease in the amount of NAC or NAL in the reaction solution is evaluated in this assay as an indicator of the test substance's skin sensitization ability. However, the products formed between the nucleophilic reagent and the test substance, which play an important role in vivo, are not directly identified. Therefore, six highly reactive chemicals, including the proficiency substances listed in the OECD Test Guidelines─squaric acid diethyl ester, 2-methyl-2H-isothiazol-3-one (MI), p-benzoquinone, palmitoyl chloride, diphenylcyclopropenone (DPCP), and imidazolidinyl urea (IU)─were used to determine each formed product. Samples were prepared according to the standard ADRA method, and the formed products were predicted on the basis of the reaction mechanism. Excluding DPCP, the estimated structures were validated using mass spectrometry and nuclear magnetic resonance spectrometry on the synthesized samples. In this manner, the products of each nucleophile were confirmed for all examined test substances. The estimated structure products were obtained through a series of reactions initiated by the nucleophilic attack of NAC's thiol group or NAL's amino group on the test substance's electron-deficient carbonyl carbon. However, contrary to expectations, disulfide-linked-type ring-opened products were detected in the case of MI, and products with free formaldehyde in solution were detected in the case of IU. In summary, all skin sensitizers tested herein reacted with NAC and/or NAL to give products. This supports the theoretical validity of ADRA, which provides an indirect evaluation of the formed products based on a decrease in nucleophilic reagents.