Roman Olegovich Gorbatov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Roman Olegovich Gorbatov has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Andrey A. Zykin
Privolzhsky Research Medical University of the Ministry of Health of the Russian Federation
3 shared publications E.E. Malyshev
Privolzhsky Res Med Univ, Dept Traumatol Orthoped & Mil Surg, 10-1 Minin & Pozharsky Sq, Nizhnii Novgorod 603950, Russia
3 shared publications- Anton Viktorovich Yarikov
Privolzhsky District Medical Center
2 shared publications D.V. Pavlov
2 shared publications- Evgeniy E. Malyshev
федеральное государственное бюджетное образовательное учреждение высшего образования «Приволжский исследовательский медицинский университет» Министерства здравоохранения Российской Федерации
2 shared publications N.N. Karyakin
Privolzhsky Res Med Univ, 10-1 Minin & Pozharsky Sq, Nizhnii Novgorod 603950, Russia
2 shared publications
Latest Publications
- Open Access
- 15 May 2026
- Published by Euroasian Scientific and Industrial Chamber, Ltd. in Современные проблемы науки и образования (Modern Problems of Science and Education)
- No. №5 2026,p. 11
КОРРЕЛЯЦИЯ КТ- И РЕНТГЕНОЛОГИЧЕСКИХ ПАРАМЕТРОВ ПОЛОЖЕНИЯ НАДКОЛЕННИКА И РОТАЦИИ БЕДРЕННОЙ КОСТИ У ПАЦИЕНТОВ С ДИСПЛАСТИЧЕСКИМ ГОНАРТРОЗОМ III СТАДИИ ПРИ ПЛАНИРОВАНИИ ТОТАЛЬНОГО ЭНДОПРОТЕЗИРОВАНИЯ КОЛЕННОГО СУСТАВА
Эндопротезирование коленного сустава является одной из самых распространенных ортопедических операций, выполняемой по поводу гонартроза III стадии. Коленный сустав представляет собой сложную анатомическую структуру, обеспечивающую опороспособность нижней конечности, возможность движений и стабильность при осевых и сдвигающих нагрузках, возникающих при передне-заднем и медиально-латеральном отклонениях. Визуализация играет важную роль в диагностике и лечении гонартроза. Оценка изображений может помочь в принятии решений о консервативном или оперативном лечении. Цель. Провести корреляционный анализ рентгенологических индексов высоты надколенника и угла между трансэпикондилярной и задней мыщелковой линиями, определяемыми по данным компьютерной томографии, у пациентов с диспластическом гонартрозом III стадии при планировании тотального эндопротезирования коленного сустава. В ретроспективном клиническом исследовании были проанализированы данные 104 пациентов со средним возрастом 57,9 ± 13,7 года с диагнозом «диспластический гонартроз III стадии». Всем пациентам в предоперационном периоде выполнены инструментальные обследования: рентгенография в двух проекциях и компьютерная томография (КТ). Статистический анализ выявил значимые корреляции между основными измеряемыми параметрами (данные рентгенографии в сагиттальной плоскости и данными КТ), что указывает на статистически значимую взаимосвязь между предоперационными значениями и может служить дополнительным ориентиром при предоперационной оценке. При этом не было обнаружено корреляций между параметрами во фронтальной и сагиттальной плоскостях (включая вальгусную деформацию) и параметрами, полученными с помощью КТ.
- 15 May 2026
- Published by Euroasian Scientific and Industrial Chamber, Ltd. in Современные проблемы науки и образования (Modern Problems of Science and Education)
- No. №5 2026,p. 11
Open AccessКОРРЕЛЯЦИЯ КТ- И РЕНТГЕНОЛОГИЧЕСКИХ ПАРАМЕТРОВ ПОЛОЖЕНИЯ НАДКОЛЕННИКА И РОТАЦИИ БЕДРЕННОЙ КОСТИ У ПАЦИЕНТОВ С ДИСПЛАСТИЧЕСКИМ ГОНАРТРОЗОМ III СТАДИИ ПРИ ПЛАНИРОВАНИИ ТОТАЛЬНОГО ЭНДОПРОТЕЗИРОВАНИЯ КОЛЕННОГО СУСТАВА
Эндопротезирование коленного сустава является одной из самых распространенных ортопедических операций, выполняемой по поводу гонартроза III стадии. Коленный сустав представляет собой сложную анатомическую структуру, обеспечивающую опороспособность нижней конечности, возможность движений и стабильность при осевых и сдвигающих нагрузках, возникающих при передне-заднем и медиально-латеральном отклонениях. Визуализация играет важную роль в диагностике и лечении гонартроза. Оценка изображений может помочь в принятии решений о консервативном или оперативном лечении. Цель. Провести корреляционный анализ рентгенологических индексов высоты надколенника и угла между трансэпикондилярной и задней мыщелковой линиями, определяемыми по данным компьютерной томографии, у пациентов с диспластическом гонартрозом III стадии при планировании тотального эндопротезирования коленного сустава. В ретроспективном клиническом исследовании были проанализированы данные 104 пациентов со средним возрастом 57,9 ± 13,7 года с диагнозом «диспластический гонартроз III стадии». Всем пациентам в предоперационном периоде выполнены инструментальные обследования: рентгенография в двух проекциях и компьютерная томография (КТ). Статистический анализ выявил значимые корреляции между основными измеряемыми параметрами (данные рентгенографии в сагиттальной плоскости и данными КТ), что указывает на статистически значимую взаимосвязь между предоперационными значениями и может служить дополнительным ориентиром при предоперационной оценке. При этом не было обнаружено корреляций между параметрами во фронтальной и сагиттальной плоскостях (включая вальгусную деформацию) и параметрами, полученными с помощью КТ.
- Open Access
- 1 January 2025
- Published by Euroasian Scientific and Industrial Chamber, Ltd. in Современные проблемы науки и образования (Modern Problems of Science and Education)
- No. №3 2025,p. 6
ANALYSIS OF THE RESULTS OF SURGICAL TREATMENT OF PROGRESSIVE COLLAPSING FOOT DEFFORMITY IN ADULT PATIENTS
- 1 January 2025
- Published by Euroasian Scientific and Industrial Chamber, Ltd. in Современные проблемы науки и образования (Modern Problems of Science and Education)
- No. №3 2025,p. 6
Open AccessANALYSIS OF THE RESULTS OF SURGICAL TREATMENT OF PROGRESSIVE COLLAPSING FOOT DEFFORMITY IN ADULT PATIENTS
- Open Access
- 1 January 2025
- Published by Euroasian Scientific and Industrial Chamber, Ltd. in Современные проблемы науки и образования (Modern Problems of Science and Education)
- No. №2 2025,p. 74
COMPARATIVE ANALYSIS OF THE EFFECTIVENESS OF USING SERIAL AND INDIVIDUAL 3D-PRINTED ORTHOPEDIC INSOLES IN THE TREATMENT OF PATIENTS WITH FLAT FEET
- 1 January 2025
- Published by Euroasian Scientific and Industrial Chamber, Ltd. in Современные проблемы науки и образования (Modern Problems of Science and Education)
- No. №2 2025,p. 74
Open AccessCOMPARATIVE ANALYSIS OF THE EFFECTIVENESS OF USING SERIAL AND INDIVIDUAL 3D-PRINTED ORTHOPEDIC INSOLES IN THE TREATMENT OF PATIENTS WITH FLAT FEET
- Open Access
- 1 January 2023
- Published by Euroasian Scientific and Industrial Chamber, Ltd. in Современные проблемы науки и образования (Modern Problems of Science and Education)
- No. №6 2023,p. 11
THE USE OF INDIVIDUAL IMPLANTS IN TWO-STAGE TREATMENT OF PERIPROSTHETIC KNEE JOINT INFECTION: A CLINICAL CASE
- 1 January 2023
- Published by Euroasian Scientific and Industrial Chamber, Ltd. in Современные проблемы науки и образования (Modern Problems of Science and Education)
- No. №6 2023,p. 11
Open AccessTHE USE OF INDIVIDUAL IMPLANTS IN TWO-STAGE TREATMENT OF PERIPROSTHETIC KNEE JOINT INFECTION: A CLINICAL CASE
- Open Access
- 26 December 2022
- Published by ECO-Vector LLC in Traumatology and Orthopedics of Russia
- Vol. 28 (4) , 21-30
Results of Revision Knee Arthroplasty With Individual Implants
Background. The presence of extensive bone defects significantly complicates the possibility of stable fixation and correct spatial positioning of the revision endoprosthesis components. The primary task of revision surgery is to restore the lost bone. The use of modern implants makes it possible to replace large metaphyseal defects of the tibia and femur, including AORI type 2B и 3 bone defects. The aim of the study was to evaluate the long-term results of surgical treatment of patients with extensive bone defects (2B and 3 according to AORI) of the proximal tibia and/or distal femur using custom-made implants for revision knee arthroplasty. Methods. A retrospective clinical study was performed in 24 patients who underwent revision arthroplasty using individual implants (9 femoral and 18 tibial) made on a 3D printer in the period from 2017 to 2021. T3 defect according to AORI classification was diagnosed in 12 patients (50%), F3 defect in 1 (4.17%), F2B in 8 (33.3%), T2B in 6 (25%). All patients before surgery and 3, 6, 12 months after surgery were surveyed according to the international scales VAS, KSS, WOMAC and SF-36. Results. At the follow-up examination 12 months after the surgery, 9 out of 24 patients (37.510%) walked without additional means of support, 10 out of 24 (41.710%) with a cane, 4 out of 24 (16,78%), walkers 1 out of 24 (4.210%). There were no periprosthetic fractures during surgery and in the postoperative period. When evaluating the functional state of the knee joint, an excellent result was registered in 45.810% and 33.310%; good in 37.510% and 54.210%; satisfactory in 16.678% and 12.57% according to the KSS and WOMAC scales, respectively. When assessed on the VAS scale, there was a positive trend in the form of statistically significant decrease in pain in all patients (p0.01). Conclusion. The use of individual implants made using additive 3D printing technologies in revision knee arthroplasty in the presence of extensive bone defects (2B and 3 according to AORI) allows to perform an organ-preserving surgery without loss of the statodynamic function of the lower limb. This study has limitations due to the small sample size. We believe that it is promising to study the long-term results of surgical treatment of patients with extensive bone defects (2B and 3 AORI) of the proximal tibia and /or distal femur using individually manufactured implants for revision knee replacement and a comparative analysis of these results with those using conventional implants.
- 26 December 2022
- Published by ECO-Vector LLC in Traumatology and Orthopedics of Russia
- Vol. 28 (4) , 21-30
Open AccessResults of Revision Knee Arthroplasty With Individual Implants
Background. The presence of extensive bone defects significantly complicates the possibility of stable fixation and correct spatial positioning of the revision endoprosthesis components. The primary task of revision surgery is to restore the lost bone. The use of modern implants makes it possible to replace large metaphyseal defects of the tibia and femur, including AORI type 2B и 3 bone defects. The aim of the study was to evaluate the long-term results of surgical treatment of patients with extensive bone defects (2B and 3 according to AORI) of the proximal tibia and/or distal femur using custom-made implants for revision knee arthroplasty. Methods. A retrospective clinical study was performed in 24 patients who underwent revision arthroplasty using individual implants (9 femoral and 18 tibial) made on a 3D printer in the period from 2017 to 2021. T3 defect according to AORI classification was diagnosed in 12 patients (50%), F3 defect in 1 (4.17%), F2B in 8 (33.3%), T2B in 6 (25%). All patients before surgery and 3, 6, 12 months after surgery were surveyed according to the international scales VAS, KSS, WOMAC and SF-36. Results. At the follow-up examination 12 months after the surgery, 9 out of 24 patients (37.510%) walked without additional means of support, 10 out of 24 (41.710%) with a cane, 4 out of 24 (16,78%), walkers 1 out of 24 (4.210%). There were no periprosthetic fractures during surgery and in the postoperative period. When evaluating the functional state of the knee joint, an excellent result was registered in 45.810% and 33.310%; good in 37.510% and 54.210%; satisfactory in 16.678% and 12.57% according to the KSS and WOMAC scales, respectively. When assessed on the VAS scale, there was a positive trend in the form of statistically significant decrease in pain in all patients (p0.01). Conclusion. The use of individual implants made using additive 3D printing technologies in revision knee arthroplasty in the presence of extensive bone defects (2B and 3 according to AORI) allows to perform an organ-preserving surgery without loss of the statodynamic function of the lower limb. This study has limitations due to the small sample size. We believe that it is promising to study the long-term results of surgical treatment of patients with extensive bone defects (2B and 3 AORI) of the proximal tibia and /or distal femur using individually manufactured implants for revision knee replacement and a comparative analysis of these results with those using conventional implants.
- 3 June 2022
- Published by ECO-Vector LLC in N.N. Priorov Journal of Traumatology and Orthopedics
- Vol. 28 (4) , 5-12
Long-term results of reconstructive surgery in posttraumatic deformities of the proximal epymetaphysis of the tibia
BACKGROUND: Tibial plateau fractures (TPF) are common and account for up to 1% of all fractures. The most unfavorable results of their treatment occur with nonunion, malunion, and malunion of TPF fractures. Unfavorable functional results of treatment are due to the occurrence of stiffness in the joint, the development of post-traumatic osteoarthritis, instability in the joint and the presence of infectious complications. In this case, there are indications for surgical treatment of intraarticular fractures of TPF. AIM: to evaluate long-term results and factors leading to knee arthroplasty after reconstructive surgery for post-traumatic deformities of the proximal tibial epimetaphysis. MATERIALS AND METHODS: The long-term (in terms of 5 to 10 years) treatment results were assessed in 46 patients with malunion of intra-articular fractures of the tibial plateau, operated in the period from 2010 to 2015.The average age of patients was 47.611 years. We considered both cases of neglected conservative treatment (87%) and cases with unsuccessful surgical fixation (13%). RESULTS: The KOOS pain score was 75.0 [66.6; 94.0] points, which corresponds to a good result. Satisfactory results were observed during the examination on the basis of daily physical activity (66.1 [51.5; 85.3] points) and on the basis of symptoms and stiffness (65.4 [53.6; 86.0] points). Average scores for the attribute physical activity while playing sports, games and entertainment and for the attribute quality of life 53.75 [25.0; 81.0] and 53.8 [25.0; 81.0] points, respectively, were assessed as unsatisfactory. In terms of up to 10 years, 5 out of 46 patients (10.9%) underwent knee arthroplasty. A statistically significant relationship was determined between the varus deformity more than 3 persisting after reconstructive surgery (r=0.664, p 0.0001), the time period between injury and reconstructive surgery (r=0.262, p=0.007) and the appearance of indications for TKA. CONCLUSION: The study revealed a statistically significant direct correlation relationships between persisting varus deformity more than 3, as well as a long time interval between injury and the performed reconstructive surgery with the emergence of indications for arthroplasty.
- 3 June 2022
- Published by ECO-Vector LLC in N.N. Priorov Journal of Traumatology and Orthopedics
- Vol. 28 (4) , 5-12
Long-term results of reconstructive surgery in posttraumatic deformities of the proximal epymetaphysis of the tibia
BACKGROUND: Tibial plateau fractures (TPF) are common and account for up to 1% of all fractures. The most unfavorable results of their treatment occur with nonunion, malunion, and malunion of TPF fractures. Unfavorable functional results of treatment are due to the occurrence of stiffness in the joint, the development of post-traumatic osteoarthritis, instability in the joint and the presence of infectious complications. In this case, there are indications for surgical treatment of intraarticular fractures of TPF. AIM: to evaluate long-term results and factors leading to knee arthroplasty after reconstructive surgery for post-traumatic deformities of the proximal tibial epimetaphysis. MATERIALS AND METHODS: The long-term (in terms of 5 to 10 years) treatment results were assessed in 46 patients with malunion of intra-articular fractures of the tibial plateau, operated in the period from 2010 to 2015.The average age of patients was 47.611 years. We considered both cases of neglected conservative treatment (87%) and cases with unsuccessful surgical fixation (13%). RESULTS: The KOOS pain score was 75.0 [66.6; 94.0] points, which corresponds to a good result. Satisfactory results were observed during the examination on the basis of daily physical activity (66.1 [51.5; 85.3] points) and on the basis of symptoms and stiffness (65.4 [53.6; 86.0] points). Average scores for the attribute physical activity while playing sports, games and entertainment and for the attribute quality of life 53.75 [25.0; 81.0] and 53.8 [25.0; 81.0] points, respectively, were assessed as unsatisfactory. In terms of up to 10 years, 5 out of 46 patients (10.9%) underwent knee arthroplasty. A statistically significant relationship was determined between the varus deformity more than 3 persisting after reconstructive surgery (r=0.664, p 0.0001), the time period between injury and reconstructive surgery (r=0.262, p=0.007) and the appearance of indications for TKA. CONCLUSION: The study revealed a statistically significant direct correlation relationships between persisting varus deformity more than 3, as well as a long time interval between injury and the performed reconstructive surgery with the emergence of indications for arthroplasty.
- 11 June 2021
- Published by PANORAMA Publishing House in Vestnik Nevrologii, Psihiatrii i Nejrohirurgii (Bulletin of Neurology, Psychiatry and Neurosurgery)
- No. 7,p. 534-556
The application of three-dimensional prototyping and printing in reconstructive neurosurgery and vertebrology (literature review and own results)
This article is devoted to the analysis of the possibility of using additive technologies in clinical practice. The number of medical specialties that use 3D printing technologies to treat patients is increasing every year. Thanks to the emergence of high-tech qualified medical care, it is possible to carry out the most complex surgical interventions and give a person who is faced with serious diseases a high-quality and fulfilling life. The creation of a 3D model using the data of a specific patient, the use of 3D computer modeling and additive technologies have become a real breakthrough in many areas of surgery. Today, such an approach in planning reconstructive and restorative operations occupies an important position in modern medicine. The authors of the article presented their experience of using additive 3D printing technologies in clinical practice. The researchers paid special attention to the results of the use of additive technologies in the treatment of diseases of the spine: deformities, degenerative-dystrophic and oncological diseases.
- 11 June 2021
- Published by PANORAMA Publishing House in Vestnik Nevrologii, Psihiatrii i Nejrohirurgii (Bulletin of Neurology, Psychiatry and Neurosurgery)
- No. 7,p. 534-556
The application of three-dimensional prototyping and printing in reconstructive neurosurgery and vertebrology (literature review and own results)
This article is devoted to the analysis of the possibility of using additive technologies in clinical practice. The number of medical specialties that use 3D printing technologies to treat patients is increasing every year. Thanks to the emergence of high-tech qualified medical care, it is possible to carry out the most complex surgical interventions and give a person who is faced with serious diseases a high-quality and fulfilling life. The creation of a 3D model using the data of a specific patient, the use of 3D computer modeling and additive technologies have become a real breakthrough in many areas of surgery. Today, such an approach in planning reconstructive and restorative operations occupies an important position in modern medicine. The authors of the article presented their experience of using additive 3D printing technologies in clinical practice. The researchers paid special attention to the results of the use of additive technologies in the treatment of diseases of the spine: deformities, degenerative-dystrophic and oncological diseases.
- Open Access
- 10 June 2021
- Published by "MedINK" Publishing House in Russian journal of neurosurgery
- Vol. 23 (2) , 34-43
Cranioplasty of post-trepanation skull defects using additive 3D printing technologies
Introduction. Every year, there is an increase in the number of operations performed using personalized cranioplasts, which are made with additive 3D printing technologies. They allow surgical intervention, taking into account the characteristics of the shape of the patient's skull. This is especially important when closing large and complex defects extending from the cranial vault to the bones of the facial skeleton. One of the innovative applications of additive technologies in cranioplasty is the creation of implants, preformed based on individual 3D-printed models. However, no preliminary estimates of the results of treatment of patients using the traditional methods of cranial implants and individualized modeling methods were found in the available literary sources.The study objective is to compare the results of treatment using cranioplasts, preformed based on individual 3D-printed skull models and using traditional intraoperative modeling.Materials and methods. A study of 50 patients with post-craniotomy defects of the skull. All patients have undergone cranioplasty. Depending on the technique of individualization of the cranial implants, patients were divided into 2 groups: 1st - using individual 3D-printed models (n = 32), 2nd - traditional intraoperative modeling (n = 18).Results. Statistically, the groups differed significantly in terms of the duration of the intraoperative stage of cranioplasty, postoperative and total hospital stay, indicators of symmetry and financial costs. No differences were found in the duration of the preoperative hospital stay, the number of implant fixation points, the volume of intraoperative blood loss and the quality of life according to the SF-36. The first group (6.25 %) in comparison with the second (16.7 %) had a smaller number of postoperative complications.Conclusion. Modern 3D printing technologies recreate bone models based on patients' individual characteristics, thereby providing time for careful planning of the operation, even at the outpatient stage. The results of the study showed that the usage of cranioplasts preformed with 3D-printed models provides precise closure of post-craniotomy defects, better restoration of the skull contours, and a significant reduction in the duration of the cranioplasty stage. The use of the technology does not lead to a significant increase in the cost of treatment using traditional intraoperative modeling.
- 10 June 2021
- Published by "MedINK" Publishing House in Russian journal of neurosurgery
- Vol. 23 (2) , 34-43
Open AccessCranioplasty of post-trepanation skull defects using additive 3D printing technologies
Introduction. Every year, there is an increase in the number of operations performed using personalized cranioplasts, which are made with additive 3D printing technologies. They allow surgical intervention, taking into account the characteristics of the shape of the patient's skull. This is especially important when closing large and complex defects extending from the cranial vault to the bones of the facial skeleton. One of the innovative applications of additive technologies in cranioplasty is the creation of implants, preformed based on individual 3D-printed models. However, no preliminary estimates of the results of treatment of patients using the traditional methods of cranial implants and individualized modeling methods were found in the available literary sources.The study objective is to compare the results of treatment using cranioplasts, preformed based on individual 3D-printed skull models and using traditional intraoperative modeling.Materials and methods. A study of 50 patients with post-craniotomy defects of the skull. All patients have undergone cranioplasty. Depending on the technique of individualization of the cranial implants, patients were divided into 2 groups: 1st - using individual 3D-printed models (n = 32), 2nd - traditional intraoperative modeling (n = 18).Results. Statistically, the groups differed significantly in terms of the duration of the intraoperative stage of cranioplasty, postoperative and total hospital stay, indicators of symmetry and financial costs. No differences were found in the duration of the preoperative hospital stay, the number of implant fixation points, the volume of intraoperative blood loss and the quality of life according to the SF-36. The first group (6.25 %) in comparison with the second (16.7 %) had a smaller number of postoperative complications.Conclusion. Modern 3D printing technologies recreate bone models based on patients' individual characteristics, thereby providing time for careful planning of the operation, even at the outpatient stage. The results of the study showed that the usage of cranioplasts preformed with 3D-printed models provides precise closure of post-craniotomy defects, better restoration of the skull contours, and a significant reduction in the duration of the cranioplasty stage. The use of the technology does not lead to a significant increase in the cost of treatment using traditional intraoperative modeling.
- Open Access
- 1 June 2020
- Published by Journal Sovremennye Tehnologii v Medicine in Sovremennye tehnologii v medicine
- Vol. 12 (3) , 55-61
Digital Technologies in the Surgical Treatment of Post-Traumatic Zygomatico-Orbital Deformities
The article summarizes treatment results of 231 patients with ZOC injuries who underwent surgery at the clinical facilities of Privolzhsky Research Medical University (Nizhny Novgorod) in 2011–2019. There were treated 44.2% (102/231) of patients with post-traumatic deformities of ZOC, including 38.2% (39/102) with post-traumatic defects and deformities of the orbital floor. Based on clinical and radiological planning of surgical operations, the patients were divided into two groups: group 1 included patients who underwent surgery without preoperative virtual planning (54.9% (56/102) of cases), group 2 included patients who underwent virtually planned surgical interventions (45.1% (46/102) of cases). There were 22 and 17 patients with orbital deformities in groups 1 and 2, respectively. The optimal restoration of ZOC anatomy was observed in 75% (42/56) of patients in group 1 and 93.5% (43/46) of patients in group 2. During reconstruction of the orbital floor in patients of group 1, successful results were achieved in 68.2% (15/22) of cases and 88.2% (15/17) in group 2, various complications were observed in the rest of cases. Based on the analysis of surgical treatment results, there was developed a personalized approach to manufacturing of zygomatic bone and orbital floor implants using computer modeling and 3D printing technologies. In contrast to the conventional methods, the use of digital technologies in the surgical treatment of post-traumatic deformities of ZOC allows avoiding the problematic issues of implant positioning and the development of complications during reconstruction, significantly reducing surgical injury and improving patient rehabilitation.
- 1 June 2020
- Published by Journal Sovremennye Tehnologii v Medicine in Sovremennye tehnologii v medicine
- Vol. 12 (3) , 55-61
Open AccessDigital Technologies in the Surgical Treatment of Post-Traumatic Zygomatico-Orbital Deformities
The article summarizes treatment results of 231 patients with ZOC injuries who underwent surgery at the clinical facilities of Privolzhsky Research Medical University (Nizhny Novgorod) in 2011–2019. There were treated 44.2% (102/231) of patients with post-traumatic deformities of ZOC, including 38.2% (39/102) with post-traumatic defects and deformities of the orbital floor. Based on clinical and radiological planning of surgical operations, the patients were divided into two groups: group 1 included patients who underwent surgery without preoperative virtual planning (54.9% (56/102) of cases), group 2 included patients who underwent virtually planned surgical interventions (45.1% (46/102) of cases). There were 22 and 17 patients with orbital deformities in groups 1 and 2, respectively. The optimal restoration of ZOC anatomy was observed in 75% (42/56) of patients in group 1 and 93.5% (43/46) of patients in group 2. During reconstruction of the orbital floor in patients of group 1, successful results were achieved in 68.2% (15/22) of cases and 88.2% (15/17) in group 2, various complications were observed in the rest of cases. Based on the analysis of surgical treatment results, there was developed a personalized approach to manufacturing of zygomatic bone and orbital floor implants using computer modeling and 3D printing technologies. In contrast to the conventional methods, the use of digital technologies in the surgical treatment of post-traumatic deformities of ZOC allows avoiding the problematic issues of implant positioning and the development of complications during reconstruction, significantly reducing surgical injury and improving patient rehabilitation.
- Open Access
- 28 December 2018
- Published by ECO-Vector LLC in Traumatology and Orthopedics of Russia
- Vol. 24 (4) , 129-136-136
Regulatory Concerns about Medical Device Manufacturing Using 3D Printing: Current State of the Issue
В настоящее время на ЗD-принтерах создаются индивидуальные имплантаты, ортопедические стельки, ортезы, макеты для предоперационного планирования и обучения и многое другое. В представленном обзоре авторы обобщили информацию о законах и подзаконных актах в области правового обеспечения ЗD-печати медицинских изделий в России и за рубежом. ЗD-печать является одним из перспективных направлений в сфере разработки новых методов лечения, поэтому необходимо уже сейчас установить четкие критерии ее правового регулирования. Однако до сих пор в законодательстве существует множество пробелов. Нерешенными остаются вопросы качества ЗD-моделей, стандартизации материалов и процессов их изготовления с использованием технологий ЗD-печати. При использовании индивидуальных изделий медицинского назначения необходимо соблюдать права пациентов и не допускать использования запрещенных или ограниченных к продаже материалов, но в то же время избегать правовых барьеров для развития этого инновационного направления медицины.
- 28 December 2018
- Published by ECO-Vector LLC in Traumatology and Orthopedics of Russia
- Vol. 24 (4) , 129-136-136
Open AccessRegulatory Concerns about Medical Device Manufacturing Using 3D Printing: Current State of the Issue
В настоящее время на ЗD-принтерах создаются индивидуальные имплантаты, ортопедические стельки, ортезы, макеты для предоперационного планирования и обучения и многое другое. В представленном обзоре авторы обобщили информацию о законах и подзаконных актах в области правового обеспечения ЗD-печати медицинских изделий в России и за рубежом. ЗD-печать является одним из перспективных направлений в сфере разработки новых методов лечения, поэтому необходимо уже сейчас установить четкие критерии ее правового регулирования. Однако до сих пор в законодательстве существует множество пробелов. Нерешенными остаются вопросы качества ЗD-моделей, стандартизации материалов и процессов их изготовления с использованием технологий ЗD-печати. При использовании индивидуальных изделий медицинского назначения необходимо соблюдать права пациентов и не допускать использования запрещенных или ограниченных к продаже материалов, но в то же время избегать правовых барьеров для развития этого инновационного направления медицины.