Latest Publications

  • Feasibility Study of HTS Current Leads With MgB2 Shunt for Tokamak Application

    by Nitin Bairagi, Vipul L. Tanna, Hiren Nimavat, Dashrath Sonara, Atul Garg, Rohitkumar Panchal, Gaurang Mahesuria, Rakeshkumar Patel, Dikens Christian, Gaurav Purwar, et al.

    Gas helium cooled HTS/MgB 2 based hybrid superconducting current feeders system have potential benefits in terms of better temperature margin and cryo stability for superconducting tokamaks and accelerators. As a proof of principle, a hybrid current feeders system comprising of a 3.3 kA rated prototype HTS current leads (CL) pair equipped with a meter long in-house developed MgB 2 shunt is recently tested at the Institute for Plasma Research (IPR). The prototype HTS CL and its bottom MgB 2 shunt is tested up to the maximum rated current of 3.3 kA with a ramp rate up to 300 A/s. The heat exchanger (HX) part is cooled using liquid nitrogen (LN 2 ). The HTS module utilizes BSCCO-2223 tapes. The bottom MgB 2 shunt section is cooled near 5 K–10 K using cold helium gas from a liquid helium Dewar. Prior to helium cooling, HX is pre-cooled to 80 K by utilizing LN 2 that allows HTS module and bottom MgB 2 shunt section conduction cooing thus optimizing and saving helium consumption. The scarcity of liquid helium in the market makes HTS/MgB 2 based superconducting current feeders a prominent candidate for large scale SC magnets application. The integrated test set-up is equipped with necessary sensors and diagnostics for detailed characterization. The temperature distribution at various sections of CL are reported in detail under cold and charging conditions. Here, we report the detailed experimental characterization results for HTS CL equipped with MgB 2 shunt under cold conditions. The main outcomes from the experiment are presented and discussed in detail.


  • Test Results of a Prototype HTS Current Lead With MgB2 and NbTi Superconducting Joints

    by Nitin Bairagi, Vipul L. Tanna, Hiren Nimavat, Dashrath Sonara, Rohitkumar Panchal, Atul Garg, Gaurang Mahesuria, Rakeshkumar Patel, Dikens Christian, Pradip Panchal, et al.

    Conventional vapor cooled current leads (CL) based on low-temperature superconductor are the major consumer of liquid helium in large-scale superconducting magnets-based nuclear fusion devices. Use of conduction-cooled, high-temperature superconductors (HTS) CL enable operation up to 80 K and saves significant cold capacity of cryo plant. Recently at Institute for Plasma Research, India, a 3.3 kA rated prototype HTS CL pair is developed with the help of Indian industries. It exploits various superconducting materials operating from 5 to 80 K. HTS module is based on commercially available rare earth cuprate oxide superconductor based BSCCO-2223 tapes. For testing purpose, we have developed bottom lap joints using composite magnesium diboride (MgB 2 ) wires as an intermediate between HTS module and NbTi: Cu cable that act as a shunt between CL pair. Such a hybrid concept is adopted as the next step to developing MgB 2 superconducting current feeder which could be operated near 20 K and save cryogenic cost in future fusion machines. Here, we report the salient features, basic details of HTS CL, superconducting joints fabrication, its test set-up, and experimental results. The inference from test results is then reported and discussed in detail.


  • Preliminary design and analysis of 20 K helium cooled MgB2 based superconducting current feeder system for Tokamak application

    by Nitin Bairagi, Vipul Tanna, Raju Daniel

    Current feeders system (CFS) is one of the most critical part of a large-scale superconducting (SC) magnets based machines like a tokamak or accelerator. One end of the SC feeder is connected to magnets and another end is connected to the power supply via optimised current leads (CL) for energizing the magnets. So far, low temperature superconductor (LTS) is the popular choice for such applications. For high temperature superconductor (HTS) applications, cuprate oxide based coated conductors or magnesium diboride (MgB 2 ) wires are the options. MgB 2 despite of its superconducting transition temperature of 39 K,is now gaining wide attention for SC feeders system due to its lower raw material cost and ease of availability than 2G HTS tapes. To assess its suitability, we report 1-D thermo-hydraulic study of 10 kA rated MgB 2 current feeders system cooled with 20 K helium for SST-1 tokamak as a case study. For varying mass flow rate, temperature margin along the feeder are calculated considering helium at 20 K, 4 bar (a) with cooling inlet from magnet side. Such a feeder yields a temperature margin of 6 K–16 K across its entire length depending up on mass flow rate of helium. There is also a possibility of cooling the binary current lead (HTS + MgB 2 ) from cold helium coming out from the feeder. From our study, MgB 2 current feeder system provides benefits of higher temperature margin, lower mass flow requirement and cryogenic savings by use of 20 K helium as coolant compared to LTS based feeders. In future, it could provide a safe, reliable and cryogenic operational cost saving solution for SC current feeders for Tokamak applications.


  • Thermo-Hydraulic Study of MgB2 Superconducting Feeder for SST-1 Tokamak

    by Nitin Bairagi, Vipul L. Tanna

    Better cryo stability is mandatory for any superconducting feeders system of fusion devices as the large amount of the magnet-stored energy can be safely dumped via feeder path only. Magnesium diboride (MgB2) as a feeder may provide innovative solution in lieu of low temperature superconductor (LTS). It has a critical superconducting transition temperature (TC) of 39 K, ductile nature, ease of availability at a relatively lower cost. SST-1 Tokamak at IPR India utilizes NbTi/Cu based cable-in-conduit-conductors (CICC) for its superconducting (SC) feeders rated at 10 kA and designed to be cooled using forced-flow helium at 4.5 K, 0.4 MPa. In order to assess the suitability of MgB2 as feeder, we report a thermo-hydraulic study of 10 kA rated SC feeders for SST-1. The results show that MgB2 SC feeders can provide benefits of higher temperature margin at a lower mass flow rate with reduced pressure drop and the cryo plant capacity savings in comparison to existing NbTi based feeders.


  • Open Access

    Cryogenic process optimization for simultaneous cool down of the TF and PF superconducting coils of SST-1 Tokamak

    by P Panchal, R Panchal, R Patel, G Mahesuriya, D Sonara, L N G Srikanth, A Garg, D Christian, N Bairagi, R Sharma, et al.

    Recent experiments of SST-1 have shown that cryogenic heat loads are more than installed cold capacity. Due to this fact, the system cool down goes into the status-quo in temperatures at ~12K and further cool down is not possible. This issue can be resolved in three folds i.e. by grouping and distribution of the PF coils, optimization of the cryogenic plant process and heat loads reduction. First, we replaced common PF coils distribution to three groups having equal path lengths. Secondly, providing the best possible pressure heads to each PF groups during cool down and using turbine-C to get cold capacity with active cooling of all paths. Third is the heat loads reduction at some parts of SST-1. While adopting the same, it has been shown that the simultaneous cool down of the TF and PF coils are possible while achieving superconducting transition in all the coils except PF-5(lower).


  • Development of lab scale sub-cooled liquid nitrogen facility for high temperature superconductor applications

    by Nitin Bairagi, H. Nimavat, D. Sonara, V. L. Tanna

    The technological advances in high temperature superconductors (HTS) have led to its use in various high voltage and high current applications. HTS based devices have huge application prospect compared to low temperature superconductors (LTS) owing to their higher engineering current density, higher critical temperature (hence higher operating temperature) resulting in high power density and lower investment on cryogenics. Here we report the development of sub-cooled liquid nitrogen facility for cooling small scale HTS application with single phase liquid nitrogen under a temperature range of 64 K – 77 K. We have sub-cooled liquid nitrogen inside commercially available 50 L Dewar by boiling nitrogen under reduced pressure. As a proof of principle, we have cooled a 1 meter long vacuum insulated flexible cryogenic transfer line to 70 K using sub-cooled nitrogen. This same facility can be used to efficiently cool future High Temperature Superconductor (HTS) based applications at a laboratory scale.

  • Open Access

    Initial results in SST-1 after up-gradation

    by S Pradhan, Z Khan, V L Tanna, U Prasad, Y Paravastu, D C Raval, H Masand, Aveg Kumar, J R Dhongde, S Jana, et al.

    SST-1 Tokamak has recently completed the 1st phase of up-gradation with successful installation and integration of all its First Wall components. The First Wall of SST-1 comprises of ~ 3800 high heat flux compatible graphite tiles being assembled and installed on 132 CuCrZr heat sink back plates engraved with ~ 4 km of leak tight baking and cooling channels in five major sub groups equipped with ~ 400 sensors and weighing ~ 6000 kg in total in thirteen isolated galvanic and six isolated hydraulic circuits. The phase-1 up-gradation spectrum also includes addition of Supersonic Molecular Beam Injection (SMBI) both on the in-board and out-board side, installation of fast reciprocating probes, adding some edge plasma probe diagnostics in the SOL region, installation and integration of segmented and up-down symmetric radial coils aiding/controlling plasma rotations, introduction of plasma position feedback and density controls etc. Post phase-I up-gradation spanning from Nov 2014 till June 2016, initial plasma experiments in up-graded SST-1 have begun since Aug 2016 after a brief engineering validation period in SST-1. The first experiments in SST-1 have revealed interesting aspects on the 'eddy currents in the First Wall support structures' influencing the 'magnetic Null evolution dynamics' and the subsequent plasma start-up characteristics after the ECH pre-ionization, the influence of the first walls on the 'field errors' and the resulting locked modes observed, the magnetic index influencing the evolution of the equilibrium of the plasma column, low density supra-thermal electron induced discharges and normal ohmic discharges etc. Presently; repeatable ohmic discharges regimes in SST-1 having plasma currents in excess of 65 KA (qa ~ 3.8, BT = 1.5 T) with a current ramp rates ~ 1.2 MA/s over a duration of ~ 300 ms with line averaged densities ~ 0.8 × 1019 and temperatures ~ 200 eV with copious MHD signatures have been experimentally established. Further elongation of the plasma duration up to one second or more with position and density feedback as well as coupling of Lower Hybrid waves are currently being persuaded in SST-1 apart from increasing the core plasma parameters with further optimizations and with wall conditioning.


  • Open Access

    Cryogenic heat loads analysis from SST-1 plasma experiments

    by N Bairagi, V L Tanna, S Pradhan

    Cryogenic heat load analysis is an important aspect for stable operation of Tokamaks employing large scale superconducting magnets. Steady State Superconducting Tokamak (SST-1) at IPR is equipped with superconducting magnets system (SCMS) comprising sixteen numbers of modified 'D' shaped toroidal field (TF) and nine poloidal field (PF) superconducting coils which are wound using NbTi/Cu based cable-in conduit conductor (CICC). SST-1 magnets operation has flexibility to cool either in two-phase with sub-cooling, two-phase without sub-cooling or single phase (supercritical) helium using a dedicated 1.3 kW helium refrigerator cum liquefier (HRL). Here, we report gross heat losses for integrated TF superconducting magnets of SST-1 during the plasma campaign using cryogenic helium supply/return thermodynamic data from cryoplant. Heat loads mainly comprising of steady state as well as transient loads are smoothly absorbed by SST-1 cryogenic helium plant during plasma experiments. The corresponding heat produced in the coils is totally released to the helium flowing through the TF coils, which in turn is dumped into liquid helium stored in main control Dewar. These results are very useful reference for heat loss analysis for TF as well as PF coils and provides database for future operation of SST-1 machine.

  • Open Access

    Process optimization of helium cryo plant operation for SST-1 superconducting magnet system

    by P Panchal, R Panchal, R Patel, G Mahesuriya, D Sonara, L N Srikanth G, A Garg, D Christian, N Bairagi, R Sharma, et al.

    Several plasma discharge campaigns have been carried out in steady state superconducting tokamak (SST-1). SST-1 has toroidal field (TF) and poloidal field (PF) superconducting magnet system (SCMS). The TF coils system is cooled to 4.5 - 4.8 K at 1.5 – 1.7 bar(a) under two phase flow condition using 1.3 kW helium cryo plant. Experience revealed that the PF coils demand higher pressure heads even at lower temperatures in comparison to TF coils because of its longer hydraulic path lengths. Thermal run away are observed within PF coils because of single common control valve for all PF coils in distribution system having non-uniform lengths. Thus it is routine practice to stop the cooling of PF path and continue only TF cooling at SCMS inlet temperature of ~ 14 K. In order to achieve uniform cool down, different control logic is adopted to make cryo stable system. In adopted control logic, the SCMS are cooled down to 80 K at constant inlet pressure of 9 bar(a). After authorization of turbine A/B, the SCMS inlet pressure is gradually controlled by refrigeration J-T valve to achieve stable operation window for cryo system. This paper presents process optimization for cryo plant operation for SST-1 SCMS.