Małgorzata Muzalewska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Małgorzata Muzalewska has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Marek Wyleżoł
Department of Fundamentals of Machinery Design, Faculty of Mechanical Engineering, Silesian University of Technology, Konarskiego 18A, 44-100 Gliwice, Poland
5 shared publications - Monika Dobrzyńska-Mizera
Institute of Materials Technology, Polymer Division, Poznan University of Technology, Piotrowo 3, 61-138 Poznan, Poland
3 shared publications - Jacek Andrzejewski
Institute of Materials Technology, Poznan University of Technology, Piotrowo 3, 61-138 Poznań, Poland
2 shared publications - Maria Laura Di Lorenzo
National Research Council, Institute of Polymers, Composites and Biomaterials, Via Campi Flegrei, 34, Pozzuoli (NA) 80078, Italy
2 shared publications Michał Mikulski
Artdent Dental Office, Piekarska 11-13, 62-800 Kalisz, Poland
2 shared publications- Monika Knitter
Institute of Materials Technology, Polymer Division, Poznan University of Technology, Piotrowo 3, 61-138 Poznan, Poland
2 shared publications
Latest Publications
- Open Access
3D-Printed Polylactide-Based Implants: Influence of Processing, Radiation Sterilization and In Vivo Bioresorption on Structural and Physicochemical Material Characteristics
The manuscript details the influence of high-temperature and high-shear processing, as well as radiation sterilization, on properties of bioresorbable and osteoconductive, patient-tailored alloplastic scaffolds for guided bone regeneration. Functionalized poly(l-lactide-co-d,l-lactide) copolymer filled with hydroxyapatite was used to produce two personalized implants for upper and lower jaw reconstruction via 3D printing. Morphology analysis (SEM, µCT), gel permeation chromatography, and thermal analysis quantified the effects of melt processing and sterilization on chain structure. Physical properties of sterilized parts, such as hardness and density, proved suitable for bone implants. Removal of the upper jaw implant after 4 months and of the lower jaw substitute after 18 months enabled monitoring of bioresorption and tissue regrowth over time. Gradual overgrowth of the implants with human tissue, initiated by the osteoconductive filler, was observed, along with time-dependent polylactide degradation, showing up to 92% molar mass reduction. The medical procedures confirmed safety, nontoxicity, non-allergenicity, and, most importantly, the tissue-forming properties of the polylactide-based formulation.
Open Access3D-Printed Polylactide-Based Implants: Influence of Processing, Radiation Sterilization and In Vivo Bioresorption on Structural and Physicochemical Material Characteristics
The manuscript details the influence of high-temperature and high-shear processing, as well as radiation sterilization, on properties of bioresorbable and osteoconductive, patient-tailored alloplastic scaffolds for guided bone regeneration. Functionalized poly(l-lactide-co-d,l-lactide) copolymer filled with hydroxyapatite was used to produce two personalized implants for upper and lower jaw reconstruction via 3D printing. Morphology analysis (SEM, µCT), gel permeation chromatography, and thermal analysis quantified the effects of melt processing and sterilization on chain structure. Physical properties of sterilized parts, such as hardness and density, proved suitable for bone implants. Removal of the upper jaw implant after 4 months and of the lower jaw substitute after 18 months enabled monitoring of bioresorption and tissue regrowth over time. Gradual overgrowth of the implants with human tissue, initiated by the osteoconductive filler, was observed, along with time-dependent polylactide degradation, showing up to 92% molar mass reduction. The medical procedures confirmed safety, nontoxicity, non-allergenicity, and, most importantly, the tissue-forming properties of the polylactide-based formulation.
- 18 February 2025
- Published by Springer Nature
- p. 56-64
Applications of 3D Printing in Pediatric Rehabilitation Products
- 18 February 2025
- Published by Springer Nature
- p. 56-64
Applications of 3D Printing in Pediatric Rehabilitation Products
- 8 October 2024
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 12 (23) , 6063-6081
Thermosensitive hydrogel doped with osteoconductive fillers for the treatment of periodontitis periapicalis chronica: from synthesis to clinical trial
Herein, a chitosan-based thermosensitive hydrogel (CH) containing hydroxyapatite (HAp), poly(lactic acid) (PLDLLA) or their mixture is proposed as an innovative, biomimetic composition with antimicrobial and bone-forming properties for guided bone regeneration. The modified hydrogels were synthesized and characterized to verify their suitability for the treatment of periodontitis periapicalis chronica. Compared to the unmodified hydrogel, both CH_HAp and CH_PLDLLA revealed improved mechanical properties, as evidenced by rotational rheology. FTIR analysis proved that no chemical interplay existed between the components. All the tested samples displayed no cytotoxicity against osteoblast-like cell culture and confirmed antimicrobial features, both crucial from an application perspective. Radiation sterilization dosage was tailored for the tested samples to maintain sterility for a minimum of 8 weeks of storage and limit crosslinking of the samples. Finally, the hydrogel was used in a clinical trial to treat a patient with chronic inflammation of periapical tissues in teeth 26 and 27. The medical procedure proved the safety, nontoxicity, non-allergenicity, and, most importantly, bone-forming properties of the hydrogel formulation. The kinetics of new bone formation was analyzed in-depth using graphical cross-sections of anatomical structures obtained from pre- and post-operative CBCT scans.
- 8 October 2024
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 12 (23) , 6063-6081
Thermosensitive hydrogel doped with osteoconductive fillers for the treatment of periodontitis periapicalis chronica: from synthesis to clinical trial
Herein, a chitosan-based thermosensitive hydrogel (CH) containing hydroxyapatite (HAp), poly(lactic acid) (PLDLLA) or their mixture is proposed as an innovative, biomimetic composition with antimicrobial and bone-forming properties for guided bone regeneration. The modified hydrogels were synthesized and characterized to verify their suitability for the treatment of periodontitis periapicalis chronica. Compared to the unmodified hydrogel, both CH_HAp and CH_PLDLLA revealed improved mechanical properties, as evidenced by rotational rheology. FTIR analysis proved that no chemical interplay existed between the components. All the tested samples displayed no cytotoxicity against osteoblast-like cell culture and confirmed antimicrobial features, both crucial from an application perspective. Radiation sterilization dosage was tailored for the tested samples to maintain sterility for a minimum of 8 weeks of storage and limit crosslinking of the samples. Finally, the hydrogel was used in a clinical trial to treat a patient with chronic inflammation of periapical tissues in teeth 26 and 27. The medical procedure proved the safety, nontoxicity, non-allergenicity, and, most importantly, bone-forming properties of the hydrogel formulation. The kinetics of new bone formation was analyzed in-depth using graphical cross-sections of anatomical structures obtained from pre- and post-operative CBCT scans.
- 20 May 2024
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 12 (13) , 3374-3388
Design, clinical applications and post-surgical assessment of bioresorbable 3D-printed craniofacial composite implants
This paper describes in detail the design, fabrication, clinical trial evaluation and post clinical application analysis of 3D-printed bone implants made from the nHAp@PLDLLA [nanohydroxyapatite; poly( l -lactide- co - d , l -lactide)] biomaterial.
- 20 May 2024
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 12 (13) , 3374-3388
Design, clinical applications and post-surgical assessment of bioresorbable 3D-printed craniofacial composite implants
This paper describes in detail the design, fabrication, clinical trial evaluation and post clinical application analysis of 3D-printed bone implants made from the nHAp@PLDLLA [nanohydroxyapatite; poly( l -lactide- co - d , l -lactide)] biomaterial.
- Open Access
Effect of the Advanced Cranial and Craniofacial Implant Fabrication on Their Degradation Affinity
Biodegradable craniofacial and cranial implants are a new aspect in terms of reducing potential complications, especially in the long term after surgery. They are also an important contribution in the field of surgical reconstructions for children, for whom it is important to restore natural bone in a relatively short time, due to the continuous growth of bones. The aim of this study was to verify the impact of the technology on biodegradability and to estimate the risk of inappropriate implant resorption time, which is an important aspect necessary to select prototypes of implants for in vivo testing. Prototypes of implants were made using two technologies: 3D printing using a PLDLA: poly(L-co-D,L lactide) (PLDLA) filament containing hydroxyapatite nanoparticles, and injection using PLDLA. After the radiation sterilization process, they were subjected to in vitro degradation under accelerated conditions. As part of this study, the in vitro degradation of newly developed biodegradable implant technologies was assessed in accordance with the guidelines of European standards. It was found that the implant manufacturing process had a significant impact on the degradation time under simulated conditions in various media. Implants made using the injection technique were characterized by lower susceptibility to degradation media compared to the 3D-printed implant under accelerated conditions.
Open AccessEffect of the Advanced Cranial and Craniofacial Implant Fabrication on Their Degradation Affinity
Biodegradable craniofacial and cranial implants are a new aspect in terms of reducing potential complications, especially in the long term after surgery. They are also an important contribution in the field of surgical reconstructions for children, for whom it is important to restore natural bone in a relatively short time, due to the continuous growth of bones. The aim of this study was to verify the impact of the technology on biodegradability and to estimate the risk of inappropriate implant resorption time, which is an important aspect necessary to select prototypes of implants for in vivo testing. Prototypes of implants were made using two technologies: 3D printing using a PLDLA: poly(L-co-D,L lactide) (PLDLA) filament containing hydroxyapatite nanoparticles, and injection using PLDLA. After the radiation sterilization process, they were subjected to in vitro degradation under accelerated conditions. As part of this study, the in vitro degradation of newly developed biodegradable implant technologies was assessed in accordance with the guidelines of European standards. It was found that the implant manufacturing process had a significant impact on the degradation time under simulated conditions in various media. Implants made using the injection technique were characterized by lower susceptibility to degradation media compared to the 3D-printed implant under accelerated conditions.
- Open Access
- 22 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 11070
Methodology of Multicriterial Optimization of Geometric Features of an Orthopedic Implant
The main purpose of the article is to describe the methodology used for multi-criteria optimization of the geometric features of the orthopedic implant used for the reconstruction of the anterior cruciate ligament located in the knee joint. The methodology includes: 1. Method of development of the bones of the knee joint model; 2. Method of multi-criteria optimization of the geometric features of the orthopedic implant using an artificial immune system, the objective function and the Pareto front; 3. Expert evaluation method based on forms. The work confirmed that the assumed thesis, a multi-criteria optimization using an artificial immune system, which is a specially defined objective function, and the Pareto method, which allows to determine the geometrical features of the implant, will lead to fulfill optimal blood perfusion and sufficient strength properties of the implant simultaneously. We conclude that the described methodology allowed to achieve the optimal geometrical features of the orthopedic implant used for reconstruction of the anterior cruciate ligament located in the knee joint.
- 22 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 11070
Open AccessMethodology of Multicriterial Optimization of Geometric Features of an Orthopedic Implant
The main purpose of the article is to describe the methodology used for multi-criteria optimization of the geometric features of the orthopedic implant used for the reconstruction of the anterior cruciate ligament located in the knee joint. The methodology includes: 1. Method of development of the bones of the knee joint model; 2. Method of multi-criteria optimization of the geometric features of the orthopedic implant using an artificial immune system, the objective function and the Pareto front; 3. Expert evaluation method based on forms. The work confirmed that the assumed thesis, a multi-criteria optimization using an artificial immune system, which is a specially defined objective function, and the Pareto method, which allows to determine the geometrical features of the implant, will lead to fulfill optimal blood perfusion and sufficient strength properties of the implant simultaneously. We conclude that the described methodology allowed to achieve the optimal geometrical features of the orthopedic implant used for reconstruction of the anterior cruciate ligament located in the knee joint.
- Open Access
- 29 December 2017
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 54 (4) , 347-351
An evaluation of the relationship between the range of mandibular opening and the condyle positions in functional panoramic radiographs
- 29 December 2017
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 54 (4) , 347-351
Open AccessAn evaluation of the relationship between the range of mandibular opening and the condyle positions in functional panoramic radiographs
- 24 October 2017
- Published by Springer Nature
- p. 289-297
Methodology of multicriterial optimization of geometric features of an orthopedic implant
- 24 October 2017
- Published by Springer Nature
- p. 289-297
Methodology of multicriterial optimization of geometric features of an orthopedic implant