KMKevin P. McNamara

Kevin P. McNamara

*This is an algorithmically generated author record based on publicly available information.

Kevin P. McNamara has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Nonlinear Modeling of Series-Type Pendulum Tuned Mass Damper-Tuned Liquid Damper

    by Kevin P McNamara, J. Shayne Love, Michael J. Tait

    The nonlinear response of a series-type pendulum tuned mass damper-tuned liquid damper (TMD-TLD) system is investigated in this study. The TLD is mounted on the pendulum TMD in series to remove the need for costly viscous damping elements. Since the response of the TMD is greater than that of the primary structure, the TLD experiences a significant base motion, leading to a highly nonlinear response that is difficult to model. The nonlinear pendulum TMD equation of motion is modeled without linearizing assumptions. The TLD is represented by an incompressible smoothed particle hydrodynamics (SPH) model that can capture large sloshing responses. The nonlinear model results are compared to shake table testing for a TMD-TLD system and a linear equivalent mechanical model. Four system configurations are considered. The nonlinear model shows good agreement with the experimental data for the TMD displacement and TLD wave heights in both time and frequency domains. The nonlinear model shows improved agreement compared to the linear model for all cases studied, especially for the TLD wave heights. The impact of simplifying the pendulum TMD equation of motion by the small-angle assumption is investigated for two cases. The results indicate that the simplified pendulum equation does not properly capture the frequency of the TMD in the TMD-TLD system and results in a reduction in calculated TLD wave heights compared to the fully nonlinear equation. It is therefore critical to consider the fully nonlinear pendulum TMD response to capture the TMD-TLD behavior.


  • Nonlinear multimodal model for an annular tuned sloshing damper equipped with damping screens

    by J Shayne Love, Kevin P McNamara, Michael J Tait, Trevor C Haskett

    Annular tuned sloshing dampers equipped with damping screens are studied experimentally and analytically. A nonlinear multimodal model is presented to simulate the coupled response among the lowest order sloshing modes in a tank equipped with damping screens, which leads to velocity-squared damping. Shake table tests are conducted on annular tanks with various inner radii, water depths, screen orientations, and base excitation amplitudes. The proposed model is evaluated by comparing the predicted and measured sloshing forces, energy dissipation per cycle, and wave heights. The predicted sloshing forces and energy dissipation per cycle are in good agreement with the measured results. The wave heights show larger discrepancies, including phase shifts; however, the peak amplitudes are captured with reasonable accuracy for the tests conducted. Secondary resonances lead to multiple peaks in the frequency response plots when higher order sloshing modes become excited through modal coupling. Plots created to indicate which secondary resonances are likely to occur for a given liquid depth ratio indicate that it may not be possible to avoid all secondary resonances. Radial damping screens can be strategically positioned within the tank to provide the desired level of damping to the fundamental sloshing modes, as well as a reasonable amount of damping to higher order modes that are susceptible to secondary resonance excitation. Since existing linearized models for annular tuned sloshing dampers equipped with damping screens do not capture the important nonlinear response characteristics of these devices, the proposed model fills an important research gap necessary to facilitate their effective design.


  • Modeling the Response of Structure–Tuned Liquid Damper Systems Under Large Amplitude Excitation Using Smoothed Particle Hydrodynamics

    by Kevin P. McNamara, Michael J. Tait

    The tuned liquid damper (TLD) is a system used to reduce the response of tall structures. Numerical modeling is a very important tool when designing TLDs. Many existing numerical models are capable of accurately capturing the structure–TLD system response at serviceability levels, covering the range where TLDs are primarily intended to perform. However, these models often have convergence issues when considering more extreme structural excitations. The goal of this study is to develop a structure–TLD model without convergence limitations at large amplitude excitations. A structure–TLD numerical model where the TLD is represented by a two-dimensional incompressible smoothed particle hydrodynamics (ISPH) scheme is presented. The TLD contains damping screens which are represented by a force term based on the Morison equation. The performance of the model is assessed by comparing to experimental data for a structure–TLD system undergoing large amplitude excitations consisting of 4-h random signals and shorter transient signals. The model shows very good agreement with the experimental data for the structural response. The free surface response of the TLD is captured accurately by the model for the lower excitation forces considered, however as the excitation force is increased there are some discrepancies. The large amplitude excitations also result in smoothed particle hydrodynamics (SPH) fluid particles penetrating the boundaries, resulting in degradation of the model performance over the 4-h simulations. Overall, the model is shown to capture the response of a structure–TLD system undergoing large amplitude excitations well.


  • Response of an Annular Tuned Liquid Damper Equipped With Damping Screens

    by Kevin P. McNamara, J. Shayne Love, Michael J. Tait, Trevor C. Haskett

    Annular tuned liquid dampers (TLDs) may be installed in slender structures with limited floor space, in which people and utilities must pass through the core, such as a wind turbine or observation tower. This study investigates an annular-shaped TLD equipped with damping screens. A linearized equivalent mechanical model capable of capturing the fundamental sloshing mode response of an annular TLD is presented. An experimental shake table testing program is completed to assess the performance of the model. Thirty-six frequency sweep tests consisting of various TLD configurations, excitation amplitudes, and excitation directions are completed. Good agreement is observed between the linearized equivalent mechanical model and experimental wave heights, sloshing forces, and energy dissipated per cycle that have been filtered to include only the fundamental sloshing mode response. The model is also observed to be in good agreement with experimental data for different excitation directions. The model is coupled to a generalized structure to investigate the response of a structure equipped with an annular TLD. The annular TLD is found to reduce the response of a generalized offshore wind turbine structure undergoing harmonic force excitation. The annular TLD provides performance comparable to an optimal linear tuned mass damper (TMD) with the same properties for a range of force excitation amplitudes.


  • Tuned Sloshing Dampers With Large Rectangular Core Penetrations

    by J. S. Love, K. P. McNamara, M. J. Tait, T. C. Haskett

    Space restrictions at the top of tall buildings may necessitate using tuned sloshing dampers (TSD) tanks with large rectangular penetrations to accommodate the structural core of the tower. A finite element model is employed to predict the natural sloshing frequencies and mode shapes of liquid sloshing in a rectangular tank with a rectangular core. Equivalent mechanical properties are determined to predict the sloshing response. Frequency response predictions of wave heights, sloshing forces, and energy-dissipation per cycle agree with results from shake table testing conducted on a rectangular tank with a rectangular core. Energy dissipation due to flow around the core adds considerable damping to the liquid and is proportional to the response velocity-squared. Nonlinear coupling among sloshing modes results in multiple peaks in the frequency response plots near the fundamental resonant frequency. An interior core with a broad dimension in one direction substantially reduces the fundamental sloshing frequency and equivalent mechanical mass in the perpendicular direction; however, the fundamental sloshing frequency and equivalent mechanical mass in the parallel direction are only influenced marginally. Large rectangular cores reduce the proportion of the total water mass that is effective in controlling tower motion. A TSD with a rectangular penetrating core may enable a TSD option to be considered for the control of a tall building in cases where a traditional rectangular TSD is infeasible.


  • Series-Type Pendulum Tuned Mass Damper-Tuned Sloshing Damper

    by J. Shayne Love, K. P. McNamara, Michael J. Tait, Trevor C. Haskett

    A pendulum-type tuned mass damper (TMD)-tuned sloshing damper (TSD) system is proposed as a cost-effective device to reduce wind-induced structural motion. Lagrange's principle is employed to develop an equivalent mechanical model for the system. The sloshing liquid provides additional gravitational restoring force to the pendulum TMD but does not provide a corresponding increase to its inertia. As a result, the natural frequency of the pendulum TMD is increased due to the TSD degree-of-freedom. Shake table testing is conducted on several pendulum TMD-TSD systems that are subjected to harmonic base excitation at discrete frequencies near the natural frequency of the pendulum TMD. The modeled and experimental results are in reasonable agreement when the liquid is not shallow or the response amplitude is not large. The pendulum TMD-TSD is coupled to a linear structure, and it is demonstrated through an analytical study that the device provides performance that is comparable to a traditional TMD. The proposed system is advantageous because it does not require a viscous damping system that is often one of the most costly components of traditional TMDs.