MAMohamed Abdel-Wahed

Mohamed Abdel-Wahed

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohamed Abdel-Wahed has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pronator quadratus–sparing volar plating of distal radius fractures: A prospective study

    by Ahmed Nouh, Mohammad H. Amer, Hassan Magdy El-Barbary, Ahmed Al-Feeshawy, Mohamed Abdel-Wahed

    Purpose: Volar locked plates for the distal radius fractures (DRFs) are applied through the Henry approach, and its modification entails a routine step to disinsert the pronator quadratus from its radial and distal attachments. This muscle insertion is mostly fleshy with minimal tendinous tissue, and surgeons find it difficult to reattach at the end of the surgery, the hardware comes in direct contact with the flexor tendons. Methods: The study was performed as a single-center prospective case series to investigate the possibility of preserving the pronator quadratus and, at the same time, achieving good reduction. Out of 73 patients enrolled in the study, the pronator quadratus was successfully spared in 60 patients. The quality of reduction and fixation in these patients was assessed functionally and radiologically. Results: Cases showed radiographic union commencing 3 months postoperatively. Twenty-nine cases had to wait for the 6th months follow up radiographs. No case had a nonunion of its fracture. The PQ sparing approach can be shifted to the FCR approach when needed. In our series, the pronator quadratus muscle was taken down in 4 patients, where a satisfactory reduction could not be achieved. Conclusion: PQ sparing approach is readily adopted and can be used for the majority of DRFs, achieving a good functional and radiological outcome. Its use can enhance recovery and reduce hardware-related complications. Nonetheless, reduction should not be compromised, and the PQ sparing can be converted readily to the FCR approach.

  • Open Access

    Reinforcement K-wires reduce the risk of tibial plateau and lateral cortex fractures during open wedge high tibial osteotomy: a prospective comparative cohort study

    by Ebeed Yasin, Ahmed Darweash, Mohamed Salman, Alaa Abououf, Mohamed Abdel-Wahed, Hosam El-Din Amin

    Open wedge high tibial osteotomy (OWHTO) may be complicated by iatrogenic fractures of the tibial plateau or lateral cortex, potentially compromising osteo

  • Dorsal turnover adipo-fascial homo-digital flap, a versatile coverage solution for exposed fingers’ dorsum

    by Mohamed I Mousa, Naiem S Moiemen, Mostafa Elhadidy, Ahmed Arafat Ahmed Elready, Mahmoud Elsayed Gouda, Belal Ahmed Abdelgawad, Ahmed Gamal Hemidan, Mohamed Abdel-Wahed, Ahmed Samy Saad

    A cohort of eleven patients, presenting with fifteen fingers exhibiting soft tissue loss subsequent to trauma or burns, was included in this study. The defects ranged from 20 to 45 mm in length and appeared at various anatomical sites on the dorsal aspect of the fingers. Coverage of exposed structures was achieved utilizing a local dorsal turnover adipo-fascial flap. Soft-tissue coverage was successfully obtained in all cases (n=15). Minor distal partial flap necrosis developed in 20% of procedures (n=3), which was managed effectively with conservative treatment. Partial split-thickness skin graft (STSG) loss occurred in cases with minor flap necrosis and in one additional instance, resulting in an overall incidence of 27% (n=4). All affected areas resolved without requiring secondary grafting. In summary, the dorsal turnover adipo-fascial flap serves as a technically straightforward reconstructive option, yielding satisfactory soft-tissue coverage and aesthetic results within this series. Although some distal flap-related complications occurred, they were limited and managed with conservative measures.

  • Open Access

    Volar locking plate fixation for distal radius fractures: did variable-angle plates make difference?

    by Mohamed Abdel-Wahed, Ahmed Abdel-Zaher Khater, Mahmoud Ahmed El-Desouky

    Purpose: Two different locking plate designs are now being used for volar plating of the distal radius fractures based on the freedom of screw direction; the fixed-angle, and the variable-angle (polyaxial) plates. We investigated the clinical and radiographic outcomes of both designs. Methods: We reviewed 96 patients with 113 unstable distal radius fractures that were operated on with volar locking plates. The patients’ mean age was 41 years. Fixed-angle volar locking plates were utilized in 65 fractures and variable-angle volar locking plates in 48 fractures through modified Henry approach or extended carpal tunnel approach. Full clinical and radiographic evaluation was done for all patients with a mean follow-up of 14 months. Results: All patients had acceptable clinical and radiographic parameters. The overall functional results (Mayo score, Quick Disability of Arm, Shoulder, and Hand (Q-DASH) score, Range of motion (ROM), and grip strength) were in favor of the variable-angle plate. The radiographic parameters were better with the variable-angle group. The variable-angle group recorded less operative time but more mean image intensifier exposure time. There were two cases of flexor tendon rupture with the fixed-angle group. Fixation with the fixed-angle system needed K-wire augmentation more than the variable-angle group. There was a positive correlation between hand dominance and the final score. Conclusion: Distal radius volar locking plates yield satisfactory results comparable among different designs. In our series, the variable-angle system showed slightly better function and radiographic outcomes. Supplementary K-wires were needed more frequently with the fixed-angle system.


  • Open Access

    Temporary spanning plate across the elbow for complex fractures of the distal humerus

    by Ashraf N. Moharram, Mostafa Mahmoud, Ahmed Lymona, Ahmed Afifi, Mostafa Ezzat, Mohamed Abdel-Wahed

    Background: Open reduction internal fixation (ORIF) is the gold standard management of fractures of the distal humerus. Stable fixation to allow early mobilization is not always possible in cases with comminuted fracture patterns and bone loss, with a high failure rate. We propose augmentation of internal fixation in these unstable situations with a spanning plate across the elbow to protect the fixation construct temporarily until bone union. Methods: Eighteen patients with complex distal humeral fractures were managed with standard ORIF technique augmented with a temporary plate spanning across the elbow as an internal fixator. Cases included were either very distal, comminuted (6 cases) or insufficiency fractures (4 cases) or revision fixation cases (8 cases). The temporary spanning plate was removed as soon as signs of early radiographic union were detected. Results: Seventeen patients were available for final follow up at a mean 28.3 months. The spanning plate was removed after 3.4 months on average. At the final follow-up, the mean elbow total arc of motion was 86.3°. The mean Mayo Elbow Performance Score (MEPS) was 80, and the mean Quick Disabilities of the Arm, Shoulder and Hand (Q-DASH) score was 27. Conclusion: Spanning the elbow temporarily with a plate in adjunct to standard ORIF technique is both simple and effective in achieving fracture stability and union and minimizes failure rates after fixation of comminuted, very distal fractures, osteoporotic cases, or revision fixation cases with bone loss. Level of evidence: Level IV, Therapeutic study


  • Open Access

    The Impact of Neuroscience on the Evolution of Decision-Making in Brachial Plexus Surgery. Part II: Nerve Grafts Act as Operator Channels (How the New May Meet the Old)

    by Sherif N. Amin, Mohamad Abdel-Wahed Kotb

    Nerve grafts could be conceived of as operator channels (rather than anatomical guidance channels), proximal nerve stumps as operator donors, and distal nerve stumps and the muscles supplied by them as operator recipients. First, consequences of nerve grafts acting as molecular operator channels include recipient end to donor side nerve grafting; donor end to recipient side grafting; donor side to recipient side coaptation; recipient/donor end to donor/recipient side grafting would better be assisted by recipient/donor side to donor/recipient side grafting, augmenting not yet regenerated neuromas in continuity by bypass grafts; augmenting end-to-end repairs/grafts by side grafts; augmenting late neuromas in continuity; preserving neuromas at proximal and distal nerve stumps of injured nerves; assisting nerve transfer (neurotization); and assisting side grafting of end-to-end grafts/repairs. Second, nerve grafts act as operator channels responding to a cellular membranous bed and incremental neurolysis of fibrosis by heparin and chondroitinase ABC. Third, subjecting intact nerve endings to tensile forces to promote axonal sprouting while simultaneously relieving tensile and shear forces off the grafted or sutured area has led to the following consequences: mobilization of the brachial plexus along its whole length during surgery; not completely excising the fibrosis but leaving a posterior fibrous segment to help unload the grafted segment from tensile and shearing forces; using epiperineurial 2/0 vicryl tension sutures to both intact nerve endings to apply tensile forces to them while unloading the grafted segment; loop grafting; continual tensile forces (dynamic tension devices, magnetic nanoparticles); revision brachial plexus surgery; free muscle transplantation as internal splints; dealing with neuromata of Types 1A, 1B, 2A, 2B, 3A, and 3B (so-called neuromata in continuity) by a shortening/tensioning/loop grafting procedure; widening the indications for surgery in obstetric brachial plexus; humeral shortening osteotomy; and inciting axonal sprouting from the spinal cord into avulsed brachial plexus roots by magnetic nanoparticles. Fourth, distal nerve transfer techniques may act as conditioning lesions enhancing direct cord implantation and brachial plexus grafting, a plea for reverting to full exploration of the brachial plexus. Fifth, in chronically denervated muscles, the motor end plate can regenerate even years after nerve injury, provided muscle mass has been preserved, and the muscle has not been replaced by fibrous tissue. This has paved the way for many reconstructive procedures including direct muscle implantation.