Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guoxi Luo has a total of 118 co-authors. Here are the top co-authors by number of shared publications:

  • Libo Zhao

    School of Instrument Science and Technology, Xi’an Jiaotong University, Xi’an, China

    18 shared publications
  • Zhuangde Jiang

    State Key Laboratory for Manufacturing Systems Engineering, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi’an Jiaotong University, Xi’an, China

    12 shared publications
  • Ping Yang

    State Key Laboratory for Manufacturing Systems Engineering, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi’an Jiaotong University, Xi’an, China

    11 shared publications
  • Min Li

    State Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme Environments, Shaanxi Provincial University Engineering Research Center for Micro/Nano Acoustic Devices and Intelligent Systems, Xi’an Jiaotong University, Xi’an 710049, China

    10 shared publications
  • Zhuangde Jiang

    State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China

    9 shared publications
  • Zhikang Li

    School of Instrument Science and Technology Xi'an Jiaotong University Xi'an China

    7 shared publications

Latest Publications

  • Modulus-matched epidermal biointerfaces for robust surface electromyography sensing

    by Guoxi Luo, Jiabao Tan, Wei Luo, Jiaqi Xie, Wenyan Li, Zhikang Li, Min Li, Ping Yang, Ryutaro Maeda, Pengjun Zhao, et al.

    Surface electromyography (sEMG) has emerged as a promising modality for intuitive and efficient human–machine interfacing. However, mismatches in You

  • High-sensitivity and robust laser-induced graphene sensing arrays for spatiotemporal pulse mapping

    by Guoxi Luo, Diying Pi, Wenyan Li, Min Li, Ping Yang, Ryutaro Maeda, Libo Zhao, Zhuangde Jiang

    Real-time pulse monitoring could enable the diagnosis of cardiovascular conditions and thus has potential application value in cardiovascular health assess


  • Open Access

    High-Precision Calibration Technology and Experimental Verification for Dual-Axis Laser Communication Systems

    by Wenyan Li, Xiaolei Zhang, Lei Zhang, Xiang Wei, Guoxi Luo, Peng Zhang, Zhipeng Xue

    With the continuous improvement of remote sensing satellite resolution, laser communication technology has gained significant traction. The pointing accuracy of ground-based laser communication terminals is critical for the stability of satellite–ground laser transmission links. To enhance the pointing accuracy of ground-based laser communication terminals, this study proposes a high-precision calibration methodology utilizing an error correction mathematical model. This approach complements traditional methods. The pointing errors of an alt-azimuth dual-axis laser communication terminal system are analyzed, and the principles and implementation processes of the error correction mathematical model are presented. Calibration experiments were conducted using an existing laser communication terminal test platform. Observation error data were obtained by comparing stellar observations with theoretical stellar positions, and error model parameters were fitted. Verification through stellar observations after model establishment and error correction showed that the mean open-loop pointing error can be controlled to approximately 5″ or less. Compared to traditional methods, accuracy can be improved by over 85%, demonstrating significant and highly accurate error correction effects and validating the proposed method.


  • Open Access

    Determination of Main Bearing Dynamic Clearance in a Shield Tunneling Machine Through a Broadband PMUT Array with a Decreased Blind Area and High Accuracy

    by Guoxi Luo, Haoyu Zhang, Delai Liu, Wenyan Li, Min Li, Zhikang Li, Lin Sun, Ping Yang, Ryutaro Maeda, Libo Zhao

    Traditional PMUT ultrasonic ranging systems usually possess a large measurement blind area under the integrated transmit–receive mode, dramatically limiting its distance measurement in confined spaces, such as when determining the clearance of large bearing components. Here, a broadband PMUT rangefinder was designed by integrating six types of different cells with adjacent resonant frequencies into an array. Through overlapping and coupling of the bandwidths from the different cells, the proposed PMUTs showed a wide –6 dB fractional bandwidth of 108% in silicon oil. Due to the broadening of bandwidth, the device could obtain the maximum steady state with less excitation (5 cycles versus 14 cycles) and reduce its residual ring-down (ca. 6 μs versus 15 μs) compared with the traditional PMUT array with the same cells, resulting in a small blind area. The pulse–echo ranging experiments demonstrated that the blind area was effectively reduced to 4.4 mm in air or 12.8 mm in silicon oil, and the error was controlled within ±0.3 mm for distance measurements up to 250 mm. In addition, a specific ultrasound signal processing circuit with functions of transmitting, receiving, and processing ultrasonic waves was developed. Combining the processing circuit and PMUT device, the system was applied to determine the axial clearance of the main bearing in a tunneling machine. This work develops broadband PMUTs with a small blind area and high resolution for distance measurement in narrow and confined spaces, opening up a new path for ultrasonic ranging technology.


  • Array Equivalent Circuit Model and Experimental Analysis of Square CMUTs

    by Jie Li, Zutang Wu, Jin Li, Zhaohui Xiao, Zhikang Li, Yihe Zhao, Guoxi Luo, Jiawei Yuan, Zixuan Li, Shaohui Qin, et al.

    The equivalent circuit is a commonly used tool for performance analysis during CMUT design and optimization. In this study, the immersion equivalent circuit model of square CMUT array is established for the first time. Using this model, the vibration, electrical, and acoustic characteristics of square CMUTs can be rapidly analyzed. Consequently, it can replace the time-consuming finite element model for design and optimization. For comparison with the equivalent circuit model presented in this paper, the finite element model of the square CMUT array was established by COMSOL 6.0a. The theoretical calculation results of the equivalent circuit model are highly consistent with the FEM results. Finally, a 28×28 CMUT array composed of square cells was fabricated using the wafer bonding process, and its vibration and impedance characteristics were tested using a Laser Doppler Vibrometer and an impedance analyzer. All experimental results well verified the accuracy of the proposed equivalent circuit models.


  • Open Access

    Facile assembly of flexible, stretchable and attachable symmetric microsupercapacitors with wide working voltage windows and favorable durability

    by Xiangguang Han, Xiaoyu Wu, Libo Zhao, Min Li, Chen Jia, Zhikang Li, Jiaqi Xie, Guoxi Luo, Ping Yang, Rabah Boukherroub, et al.

    With the increasing development of intelligent robots and wearable electronics, the demand for high-performance flexible energy storage devices is drastically increasing. In this study, flexible symmetric microsupercapacitors (MSCs) that could operate in a wide working voltage window were developed by combining laser-direct-writing graphene (LG) electrodes with a phosphoric acid-nonionic surfactant liquid crystal (PA-NI LC) gel electrolyte. To increase the flexibility and enhance the conformal ability of the MSC devices to anisotropic surfaces, after the interdigitated LG formed on the polyimide (PI) film surface, the devices were further transferred onto a flexible, stretchable and transparent polydimethylsiloxane (PDMS) substrate; this substrate displayed favorable flexibility and mechanical characteristics in the bending test. Furthermore, the electrochemical performances of the symmetric MSCs with various electrode widths (300, 400, 500 and 600 μm) were evaluated. The findings revealed that symmetric MSC devices could operate in a large voltage range (0–1.5 V); additionally, the device with a 300 μm electrode width (MSC-300) exhibited the largest areal capacitance of 2.3 mF cm−2 at 0.07 mA cm−2 and an areal (volumetric) energy density of 0.72 μWh cm−2 (0.36 mWh cm−3) at 55.07 μW cm−2 (27.54 mW cm−3), along with favorable mechanical and cycling stability. After charging for ~20 s, two MSC-300 devices connected in series could supply energy to a calculator to operate for ~130 s, showing its practical application potential as an energy storage device. Moreover, the device displayed favorable reversibility, stability and durability. After 12 months of aging in air at room temperature, its electrochemical performance was not altered, and after charging-discharging measurements for 5000 cycles at 0.07 mA cm−2, ~93.6% of the areal capacitance was still retained; these results demonstrated its practical long-term application potential as an energy storage device.


  • Open Access

    Fabrication and characterization of high-sensitivity, wide-range, and flexible MEMS thermal flow velocity sensors

    by Min Li, Guangzhao Qin, Chen Jia, Danyu Zhang, Zhikang Li, Xiangguang Han, Shusheng Xu, Libo Zhao, Guoxi Luo, Cunlang Liu, et al.

    With the rapid development of various fields, including aerospace, industrial measurement and control, and medical monitoring, the need to quantify flow velocity measurements is increasing. It is difficult for traditional flow velocity sensors to fulfill accuracy requirements for velocity measurements due to their small ranges, susceptibility to environmental impacts, and instability. Herein, to optimize sensor performance, a flexible microelectromechanical system (MEMS) thermal flow sensor is proposed that combines the working principles of thermal loss and thermal temperature difference and utilizes a flexible cavity substrate made of a low-thermal-conductivity polyimide/SiO2 (PI/SiO2) composite porous film to broaden the measurement range and improve the sensitivity. The measurement results show that the maximum measurable flow velocity can reach 30 m/s with a resolution of 5.4 mm/s. The average sensitivities of the sensor are 59.49 mV/(m s−1) in the medium-to-low wind velocity range of 0–2 m/s and 467.31 mV/(m s−1) in the wind velocity range of 2–30 m/s. The sensor proposed in this work can enable new applications of flexible flow sensors and wearable devices.


  • Open Access

    Highly sensitive piezoresistive and thermally responsive fibrous networks from the in situ growth of PEDOT on MWCNT-decorated electrospun PU fibers for pressure and temperature sensing

    by Yunyun Luo, Libo Zhao, Guoxi Luo, Linxi Dong, Yong Xia, Min Li, Ziping Li, Kaifei Wang, Ryutaro Maeda, Zhuangde Jiang

    Flexible electronics have demonstrated various strategies to enhance the sensory ability for tactile perception and wearable physiological monitoring. Fibrous microstructures have attracted much interest because of their excellent mechanical properties and fabricability. Herein, a structurally robust fibrous mat was first fabricated by electrospinning, followed by a sequential process of functionalization utilizing ultrasonication treatment and in situ polymerization growth. Electrospun polyurethane (PU) microfibers were anchored with multi-walled carbon nanotubes (MWCNTs) to form conductive paths along each fiber by a scalable ultrasonic cavitation treatment in an MWCNT suspension. After, a layer of poly(3,4-ethylene dioxythiophene) (PEDOT) was grown on the surface of PU fibers decorated with MWCNTs to enhance the conductive conjunctions of MWCNTs. Due to the superior electromechanical behaviors and mechanical reinforcement of PEDOT, the PEDOT/MWCNT@PU mat-based device exhibits a wide working range (0–70 kPa), high sensitivity (1.6 kPa−1), and good mechanical robustness (over 18,000 cycles). The PEDOT/MWCNT@PU mat-based sensor also demonstrates a good linear response to different temperature variations because of the thermoelectricity of the PEDOT/MWCNT composite. This novel strategy for the fabrication of multifunctional fibrous mats provides a promising opportunity for future applications for high-performance wearable devices.


  • Small blind-area, high-accuracy ultrasonic rangefinder using a broadband multi-frequency piezoelectric micromachined ultrasonic transducer array

    by Guoxi Luo, Kang He, Yongliang Wang, Wenke Zhou, Ke Chen, Libo Zhao, Tingzhong Xu, Zhikang Li, Min Li, Ping Yang, et al.

    This paper presents a broadband ultrasonic rangefinder, with merits of a small blind area and high accuracy, based on a multi-frequency piezoelectric micromachined ultrasonic transducer (MF-PMUT) array. The coupling bandwidth between six types of resonant cells with adjacent resonant frequencies was studied and optimized, and these cells were then integrated into an array to broaden the bandwidth of the device. The array device showed a wide −6 dB fractional bandwidth of 108% in silicon oil. A wide bandwidth can contribute to obtaining the maximum steady-state with less excitation and reducing its residual ring-down, resulting in a small blind area. Pulse-echo ranging experiments demonstrated that the blind area was effectively reduced to 5 mm due to the multi-frequency array. For short distance measurements (σ accuracy was 0.445 mm. Compared with earlier reported PMUTs designed for bandwidth enhancement, the proposed broadband MF-PMUT array is much simpler in design and fabrication, revealing it as a promising candidate for short-distance high-accuracy measurements.


  • Plasma-activated silicon–glass high-strength multistep bonding for low-temperature vacuum packaging

    by Mingzhi Yu, Libo Zhao, Yongliang Wang, Yong Xia, Yintao Ma, Yanbin Wang, Xiangguang Han, Yao Chen, Shun Lu, Guoxi Luo, et al.