NHNoriyuki Hirakawa

Noriyuki Hirakawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Noriyuki Hirakawa has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Efficacy of Endoscopic Ultrasound‐guided Fine Needle Biopsy With Simplified Macroscopic On‐site Evaluation (With Video)

    by Kento Shionoya, Ryosuke Tonozuka, Shuntaro Mukai, Yuki Joyama, Takayoshi Tsuchiya, Reina Tanaka, Kenjiro Yamamoto, Kazumasa Nagai, Yukitoshi Matsunami, Hiroyuki Kojima, et al.

    Background and Aims: With advances in preoperative chemotherapy and comprehensive genomic profiling, endoscopic ultrasound‐guided fine needle biopsy (EUS‐FNB) has become vital for diagnosing pancreatic and peridigestive tract lesions. However, evidence remains limited regarding the performance of new‐generation puncture needles and simplified specimen evaluation methods. This study retrospectively assessed the diagnostic ability and procedural adverse events (AEs) of a new‐generation puncture needle for solid pancreatic, subepithelial, and other lesions. Methods: We analyzed data from 1232 consecutive patients who underwent EUS‐FNB between August 2016 and November 2023 at a single care center. Specimen processing was performed using the simplified macroscopic on‐site evaluation (S‐MOSE) method, which does not require additional pathological tests such as rapid on‐site evaluation or cytology. Results: The overall diagnostic accuracy using S‐MOSE was 93.7%. Specifically, the diagnostic accuracy for pancreatic cancer was 95.8%. The AE rate was 1.1% (14/1232), including pancreatitis (six), hemorrhage (five), hematoma (two), and pancreatic fistulas (one). The first puncture diagnostic rate was 83.6%, which increased to 92.5% after the second puncture, with only a marginal gain of 1.2% beyond the third puncture. Multivariable analysis identified smaller lesion size and benign pathology as factors associated with lower diagnostic accuracy; conversely, malignant pathology was associated with higher diagnostic accuracy (odds ratio 1.895, p = 0.011). Conclusion: EUS‐FNB with S‐MOSE, typically requiring up to two punctures, provides efficient and accurate histopathological diagnosis across diverse lesions while minimizing procedural burden. Trial Registration : N/A.

  • Open Access

    Ultra-slim pancreatoscopy-guided laser lithotripsy for retrieval of a kinked guidewire caused by a pancreatic duct stone

    by Noriyuki Hirakawa, Kazumasa Nagai, Ryosuke Tonozuka, Shuntaro Mukai, Kyoko Asano, Takao Itoi

    Pancreatic duct stones are a common complication of chronic pancreatitis, and various therapeutic approaches are available when symptoms occur [1] [2] [3]. Endoscopic treatment of pancreatic duct stones is often technically challenging [2]. However, laser lithotripsy has been reported to have favorable clinical outcomes in the treatment of these stones [4]. In addition, the usefulness of an ultra-slim peroral pancreatoscope (POPS; Briview CHV-US120J-U, 7.8 Fr; Shanghai SeeGen Photoelectric Technology Co., Ltd, Shanghai, China) has recently been reported [5]. This report describes a case in which a kinked guidewire caused by a pancreatic duct stone at a stricture site was successfully retrieved by ultra-slim pancreatoscopy-guided laser lithotripsy. A 52-year-old woman had recurrent episodes of pancreatitis caused by pancreatic duct stones. She had previously undergone extracorporeal shock wave lithotripsy and endoscopic pancreatic sphincterotomy. She was admitted to our hospital for the endoscopic removal of pancreatic duct stones. The pancreatic duct was cannulated, and pancreatography revealed pancreatic duct stones and strictures in both the pancreatic head and tail. Stone extraction was attempted using a balloon catheter and basket mechanical lithotripsy. During the procedure, the guidewire encountered a stone and became kinked at a pancreatic duct stricture in the tail ([Fig. 1]). Dilation of the stricture was attempted using a drill dilator; however, the guidewire could not be retrieved. Therefore, an additional guidewire was placed in the pancreatic duct. Given the presence of a stricture in the pancreatic duct in the head, an ultra-slim POPS was advanced over the guidewire ([Fig. 2] a). Under pancreatoscopic visualization, the pancreatic stone and the kinked guidewire were identified. The pancreatic stone was directly visualized and fragmented using laser lithotripsy ([Fig. 2] b). Next, the kinked guidewire was successfully retrieved without fracture. Finally, endoscopic nasopancreatic drainage was performed, and the procedure was completed. No procedure-related adverse events were observed ([Video 1]). Endoscopy_UCTN_Code_TTT_1AR_2A Article published online: 24 April 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    Effectiveness of immediate contrast-enhanced evaluation after endoscopic ultrasound-guided ethanol injection for a pancreatic neuroendocrine tumor

    by Shuntaro Mukai, Atsushi Sofuni, Takayoshi Tsuchiya, Ryosuke Tonozuka, Kazumasa Nagai, Noriyuki Hirakawa, Takao Itoi

    The efficacy of local ablation therapies such as endoscopic ultrasound-guided ethanol injection (EUS-EI) and radiofrequency ablation for small pancreatic neuroendocrine tumors (P-NETs, ≤15 mm, G1) has been reported [1] [2] [3] [4] [5]. However, the risk of recurrence due to residual tumor where treatment is inadequate remains a major issue. Here, we report a case showing the effectiveness of immediate contrast-enhanced EUS evaluation after EUS-EI for a small P-NET as a means of overcoming this issue. A 63-year-old man had a 15-mm pancreatic tumor in the head of the pancreas. The tumor showed early enhancement on contrast-enhanced computed tomography (CE-CT) and contrast-enhanced EUS. A pathological diagnosis of the P-NET (G1) was made by EUS-guided tissue acquisition. The patient declined surgical treatment and requested minimally invasive local ablation therapy using EUS-EI. Three transgastric punctures were performed using a 25-gauge needle, and a total of 1.8 mL of ethanol was injected. Just after EUS-EI, a high-echo area spread within the tumor, revealing the injected region. However, after a short time, it appeared as a low-echo area, making it impossible to identify areas where injection was inadequate and residual tumor was present. When contrast-enhanced EUS was subsequently performed using 0.5 mL perfluorobutane (Sonazoid; Daiichi-Sankyo, Tokyo, Japan), the contrast effect in the tumor, which showed early enhancement before EUS-EI, almost completely disappeared immediately after EUS-EI, confirming that there were no areas where the injection was insufficient ([Fig. 1], [Video 1]). No residual tumor showing enhancement was observed in a CE-CT scan performed 3 days after EUS-EI, confirming complete ablation of the tumor ([Fig. 2]). Immediate CE-EUS evaluation after EUS-EI can be considered useful for residual tumor evaluation. Endoscopy_UCTN_Code_TTT_1AS_2AI Article published online: 20 January 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Impact of a Thinner Snare Wire With Optimal Electrosurgical Unit Settings on the Risk of Delayed Bleeding After Endoscopic Papillectomy: A Propensity Score‐Matched Analysis (With Video)

    by Kenjiro Yamamoto, Takao Itoi, Takayoshi Tsuchiya, Yuki Joyama, Reina Tanaka, Ryosuke Tonozuka, Shuntaro Mukai, Kazumasa Nagai, Yukitoshi Matsunami, Hiroyuki Kojima, et al.

    Objectives: The indications for endoscopic papillectomy (EP) have expanded. However, post‐procedural adverse events remain high. We performed ex vivo and clinical studies to determine the usefulness of a thinner snare wire (TSW) for preventing delayed bleeding after EP. Methods: To verify the effect of current flow in the monopolar device, a model of an ampulla lesion was created and then resected using a snare. To examine the coagulation effects produced by varying snare wire diameters, patients who underwent EP for ampullary neoplasms were retrospectively analyzed according to the snare wire diameter in the TSW group and the conventional snare wire (CSW) group. The outcomes were compared after propensity score matching (PSM) to control for selection bias and lack of randomization. Results: In the ex vivo study, thermal denaturation was found to be stronger on the counter electrode plate side. In the clinical study, 102 patients who underwent EP were included (TSW group, n = 52; CSW group, n = 50). The matched cohorts included 29 patients per group. Delayed bleeding was significantly less frequent in the TSW group than in the CSW group after PSM (3.4% vs. 31%; p = 0.012). Although residual lesions tended to be more frequent in the TSW group ( p = 0.053), there were no significant differences in other procedural and pathological outcomes. Conclusions: The coagulation effect produced by current flow cannot be ignored. Using a TSW may decrease the incidence of delayed bleeding. It is important to select both a suitable snare wire diameter and appropriate electrosurgical unit settings.


  • Open Access

    Pancreatic Neuroendocrine Tumor Leading to a Diagnosis of Multiple Endocrine Neoplasia Type 1

    by Noriyuki Hirakawa, Katsuya Kitamura, Kei Yamamoto, Kenichi Tadokoro, Yasunosuke Akita, Jun Uemura, Fumito Yamanishi, Masakazu Abe, Munehide Nakatsugawa, Takao Itoi

    Pancreatic neuroendocrine neoplasms are rare but occasionally encountered. They are generally highly vascularized solid tumors, often round in shape with clear boundaries, defined contours, and a homogeneous internal structure. However, they can also present with atypical features, such as cystic degeneration, hemorrhage, calcification, and fibrosis, making diagnosis difficult in some cases. They are also known as comorbidities of multiple endocrine neoplasia type 1 (MEN1). This report describes a case in which endoscopic ultrasound (EUS) led to a diagnosis of MEN1. A 50‐year‐old man was referred to our hospital for examination of a mass in the pancreatic body. An EUS‐guided fine‐needle biopsy was performed, and a histological diagnosis of neuroendocrine tumor (NET) was made. In addition, the NET was also identified in the duodenum. Serum calcium and parathyroid hormone levels were elevated. Examination of the parathyroid and pituitary glands revealed concurrent hyperparathyroidism and a pituitary adenoma, confirming the diagnosis of MEN1, including a NET in the duodenum.

  • Open Access

    Verification in an animal study of the appropriate settings for a novel radiofrequency generator in radiofrequency ablation therapy for residual intraductal lesions after endoscopic papillectomy (with video)

    by Kenjiro Yamamoto, Takao Itoi, Atsushi Sofuni, Takayoshi Tsuchiya, Reina Tanaka, Ryosuke Tonozuka, Kazumasa Nagai, Yukitoshi Matsunami, Hiroyuki Kojima, Hirohito Minami, et al.

    Endoscopic intraductal radiofrequency ablation (ID‐RFA) can curatively treat residual intraductal lesions after endoscopic papillectomy. This study aimed to verify the tissue invasiveness of ID‐RFA using a novel RF generator and to explore its appropriate settings in an animal experiment, followed by a small clinical study. Pig liver specimens were ablated using a dedicated RF catheter and two RF generators to investigate structural differences between them and the ablation effects produced under various voltage and power settings. Appropriate settings for the novel generator were sought to provide an ablation effect equivalent to that with the recommended settings for a conventional generator. The ablation effect was also observed at various ablation times in vitro. Then we performed ID‐RFA in five patients. Each generator has a different structure, and no novel generator settings are identical to the recommended conventional generator settings. Obtaining adequate ablation requires both sufficient power and sufficient voltage. Based on the validation experiments, we concluded that the appropriate novel generator settings were 125 Vp and 30 W for 30 s. In the clinical study, good tumor ablation was obtained with no recurrence after a single ID‐RFA treatment, although the incidence of ductal stricture was relatively high. ID‐RFA for residual intraductal lesions may potentially be curative. However, excessive ablation should be avoided. To ensure safe and effective ID‐RFA, a thorough understanding of the RF generator specifications is required.


  • Open Access

    Endoluminal radiofrequency ablation for ingrowth occlusion after endoscopic ultrasound-guided hepaticogastrostomy with bridging stent placement

    by Kenjiro Yamamoto, Takayoshi Tsuchiya, Ryosuke Tonozuka, Shuntaro Mukai, Hiroyuki Kojima, Noriyuki Hirakawa, Takao Itoi

    Endoscopic ultrasound-guided hepaticogastrostomy with bridging stent placement is a useful drainage option when endoscopic retrograde cholangiopancreatography fails for reasons such as inaccessible papillae or surgical anastomosis, particularly in patients with malignant hilar biliary obstruction who require bilateral drainage [1] [2]. Recent advances in chemotherapy, such as targeted drugs for specific gene mutations, have improved prognosis in biliary tract cancers [3]. Therefore, the management of recurrent biliary obstruction after stent placement is also an important issue. Endoluminal radiofrequency ablation (RFA) is a novel procedure for biliary diseases and may be an option for treating ingrowth occlusion after metal stent deployment [4] [5]. An 80-year-old man was admitted with obstructive jaundice during chemotherapy for local relapse after Whipple surgery for cholangiocarcinoma. He had previously undergone right hepatic drainage with bridging metal stent placement through the hepaticogastrostomy route. Contrast-enhanced computed tomography demonstrated dilatation of the anterior bile duct ([Fig. 1]). Cholangiography and peroral cholangioscopy (POCS) revealed stent occlusion due to tumor ingrowth ([Fig. 2]). Additional stent placement through previously inserted bilateral metal stents was considered technically challenging. Thus, RFA was performed with a temperature-controlled RF catheter (ELRA; StarMed Co., Goyang, Korea). The RF generator (VIVA Combo; StarMed Co.) was set to a maximum temperature of 80°C and power of 7W for a 2-min duration and was then connected to an 18-mm RF catheter. Ablation was performed stepwise, spanning the stricture ([Fig. 3]). After RFA, a temporary endoscopic nasobiliary drainage tube was placed. Four days after RFA, cholangiography and POCS confirmed ablation of the ingrowth regions and recanalization of the stent lumen ([Fig. 4]; [Video 1]). The patient was discharged after plastic stent placement through the hepaticogastrostomy route. Recanalization using RFA was clinically successful, with no recurrence of biliary obstruction for more than 3 months. Endoscopy_UCTN_Code_TTT_1AR_2AZ Article published online: 21 October 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    One-step removal of a migrated biliary plastic stent using a novel long thin dilating balloon catheter

    by Noriyuki Hirakawa, Kenjiro Yamamoto, Takayoshi Tsuchiya, Ryosuke Tonozuka, Shuntaro Mukai, Takao Itoi

    Biliary plastic stent migration in endoscopic retrograde cholangiopancreatography (ERCP)-related procedures is a complication that is occasionally encountered [1]. Techniques for removing migrated plastic stents have been reported [2] [3] [4]; however, some cases are still challenging, even with the use of these techniques. Here, we report the one-step removal of a migrated plastic stent using a novel long dilating balloon. The patient was a 59-year-old man who had undergone biliary drainage using a straight-type 7-Fr plastic stent for obstructive jaundice due to pancreatic head cancer. He was admitted with chief complaints of chills and right upper quadrant abdominal pain. An abdominal radiograph showed stent migration ([Fig. 1]), so an emergent endoscopic procedure was performed. Endoscopic examination confirmed that the stent had become dislodged into the bile duct ([Fig. 2]), so we therefore attempted stent removal. The bile duct was cannulated, and cholangiography showed a distal bile duct stricture. After endoscopic sphincterotomy had been performed, we tried but failed to grasp the distal end of the stent with grasping forceps under fluoroscopic guidance. A stone extraction balloon catheter was advanced to the bile duct, but could not be advanced beyond the stricture owing to the migrated stent. We next attempted to use a novel long thin dilating balloon catheter (3 mm × 6 cm; REN Biliary Dilation Catheter; Kaneka Medix, Osaka, Japan) ([Fig. 3]) [5]. First, another guidewire (0.025-inch straight type) was advanced through the stent’s lumen under fluoroscopic guidance. The novel dilating balloon catheter was then inserted into the stent’s lumen ([Fig. 4]) and inflated. The balloon catheter was next pulled gently and slowly backward, with the plastic stent finally being successfully removed through the scope without further difficulty ([Video 1]). Removal was achieved as the inflated balloon expands into the flap hole, so that the balloon catheter becomes integrated with the plastic stent ([Fig. 5]). Endoscopy_UCTN_Code_CPL_1AK_2AD Article published online: 03 June 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany


  • Open Access

    Technical tip: endoscopic internalization by cutting the drainage tube after endoscopic ultrasound-guided naso-gallbladder drainage for acute cholecystitis

    by Noriyuki Hirakawa, Shuntaro Mukai, Takayoshi Tsuchiya, Reina Tanaka, Ryosuke Tonozuka, Takao Itoi

    Although a fully covered metal stent (FCMS) placed for malignant distal biliary obstruction can maintain long-term patency, it can obstruct the bifurcation of the cystic duct [1] [2]. Endoscopic ultrasound-guided naso-gallbladder drainage (EUS-NGBD) for acute cholecystitis caused by FCMS is reported to be effective [3] [4]. To prevent recurrence, it is recommended that internalization be performed by cutting the drainage tube in the stomach with a loop cutter after improvement of cholecystitis [5]. Here, we present a case of acute cholecystitis caused by FCMS placement in which EUS-NGBD was performed and endoscopic internalization was achieved using a reusable loop cutter. A 74-year-old man was referred to us with obstructive jaundice caused by unresectable pancreatic head cancer ([Fig. 1]). Endoscopic transpapillary drainage was performed by placing a 10-mm FCMS for malignant distal biliary obstruction. Acute cholecystitis occurred when the cystic duct bifurcation became obstructed by the FCMS. Use of an apposition stent to drain the gallbladder represents one option in this situation. However, this approach requires tract dilation, which increases the risk of infected bile leaking into the abdominal cavity. Therefore, EUS-NGBD was performed ([Fig. 2]). The gallbladder was punctured from the duodenal bulb using a 19-gauge needle under EUS guidance ([Fig. 3] a, [Video 1]). A 0.025-inch guidewire was inserted into the gallbladder, and the tract was dilated using a hard-type ultra-tapered bougie dilator. A 5-Fr naso-gallbladder drainage tube was inserted into the gallbladder ([Fig. 3] b). Aspiration of infected bile from the drainage tube led to rapid improvement of inflammation. Endoscopic internalization using a reusable loop cutter was performed 4 days later. The tip of the loop cutter blade was sharpened by biting the edge of a sheet of aluminum foil seven times ([Fig. 4]). The NGBD tube was cut using the sharpened loop cutter ([Fig. 5]). No procedure-related adverse events occurred, and chemotherapy was initiated. Endoscopy_UCTN_Code_TTT_1AS_2AH Article published online: 16 January 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany