Desheng Lü
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Desheng Lü has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
Wei Ren
Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Aerosp Laser Engn Dept, Shanghai 201800, Peoples R China
13 shared publications- Liang Liu
Aerospace Laser Technology and System Department, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, China
11 shared publications Lin Li
Aerospace Laser Technology and Systems Department, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, China
11 shared publicationsTang Li
Aerospace Laser Technology and Systems Department, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, China
11 shared publicationsBin Wang
Key Laboratory of Quantum Optics and Center of Cold Atom Physics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
8 shared publicationsXin Zhao
Key Laboratory of Quantum Optics, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences 1 , Shanghai 201811, China
7 shared publications
Latest Publications
- 25 May 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (21)
Precise control of launch velocity vector for cold atomic cloud based on moving optical molasses
We propose a method for precise control of the launch velocity vector of a cold atomic cloud. By independently adjusting the relative detuning of three pairs of orthogonal counter-propagating laser beams in moving optical molasses, this method achieves accurate regulation of three-dimensional velocity components, thereby realizing precise calibration of atomic launch direction. It can significantly reduce the complexity of mechanical adjustments and mitigate residual errors caused by mechanical tuning, with the advantages of simplicity and easy implementation. Experimental verification on an 87Rb atomic fountain clock shows that the spatial distribution of the cold atomic cloud is obtained via horizontal velocity scanning, and the tilt deviation of the fountain clock is evaluated and corrected. Ultimately, the angles between the cold atom launch direction, the central axis of the fountain clock, and the vertical direction are all less than 0.1 mrad. Time-of-flight signal analysis indicates that under 3% laser power fluctuation, the long-term instability (5000 s) of the velocity reaches 62 μm/s. This method holds significant application value for atomic fountains, atomic gravimeters, atomic gyroscopes, and other cold atomic precision instruments based on moving molasses.
- 25 May 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (21)
Precise control of launch velocity vector for cold atomic cloud based on moving optical molasses
We propose a method for precise control of the launch velocity vector of a cold atomic cloud. By independently adjusting the relative detuning of three pairs of orthogonal counter-propagating laser beams in moving optical molasses, this method achieves accurate regulation of three-dimensional velocity components, thereby realizing precise calibration of atomic launch direction. It can significantly reduce the complexity of mechanical adjustments and mitigate residual errors caused by mechanical tuning, with the advantages of simplicity and easy implementation. Experimental verification on an 87Rb atomic fountain clock shows that the spatial distribution of the cold atomic cloud is obtained via horizontal velocity scanning, and the tilt deviation of the fountain clock is evaluated and corrected. Ultimately, the angles between the cold atom launch direction, the central axis of the fountain clock, and the vertical direction are all less than 0.1 mrad. Time-of-flight signal analysis indicates that under 3% laser power fluctuation, the long-term instability (5000 s) of the velocity reaches 62 μm/s. This method holds significant application value for atomic fountains, atomic gravimeters, atomic gyroscopes, and other cold atomic precision instruments based on moving molasses.
- Top Cited Papers
- 19 March 2025
- Published by Springer Nature in Nature Cancer
- Vol. 6 (5) , 768-785
Palmitoylation of GPX4 via the targetable ZDHHC8 determines ferroptosis sensitivity and antitumor immunity
Ferroptosis is closely linked with various pathophysiological processes, including aging, neurodegeneration, ischemia-reperfusion injury, viral infection and, notably, cancer progression; however, its post-translational regulatory mechanisms remain incompletely understood. Here we revealed a crucial role of S-palmitoylation in regulating ferroptosis through glutathione peroxidase 4 (GPX4), a pivotal enzyme that mitigates lipid peroxidation. We identified that zinc finger DHHC-domain containing protein 8 (zDHHC8), an S-acyltransferase that is highly expressed in multiple tumors, palmitoylates GPX4 at Cys75. Through small-molecule drug screening, we identified PF-670462, a zDHHC8-specific inhibitor that promotes the degradation of zDHHC8, consequently attenuating GPX4 palmitoylation and enhancing ferroptosis sensitivity. PF-670462 inhibition of zDHHC8 facilitates the CD8+ cytotoxic T cell-induced ferroptosis of tumor cells, thereby improving the efficacy of cancer immunotherapy in a B16-F10 xenograft model. Our findings reveal the prominent role of the zDHHC8–GPX4 axis in regulating ferroptosis and highlight the potential application of zDHHC8 inhibitors in anticancer therapy.
- 19 March 2025
- Published by Springer Nature in Nature Cancer
- Vol. 6 (5) , 768-785
Top Cited PapersPalmitoylation of GPX4 via the targetable ZDHHC8 determines ferroptosis sensitivity and antitumor immunity
Ferroptosis is closely linked with various pathophysiological processes, including aging, neurodegeneration, ischemia-reperfusion injury, viral infection and, notably, cancer progression; however, its post-translational regulatory mechanisms remain incompletely understood. Here we revealed a crucial role of S-palmitoylation in regulating ferroptosis through glutathione peroxidase 4 (GPX4), a pivotal enzyme that mitigates lipid peroxidation. We identified that zinc finger DHHC-domain containing protein 8 (zDHHC8), an S-acyltransferase that is highly expressed in multiple tumors, palmitoylates GPX4 at Cys75. Through small-molecule drug screening, we identified PF-670462, a zDHHC8-specific inhibitor that promotes the degradation of zDHHC8, consequently attenuating GPX4 palmitoylation and enhancing ferroptosis sensitivity. PF-670462 inhibition of zDHHC8 facilitates the CD8+ cytotoxic T cell-induced ferroptosis of tumor cells, thereby improving the efficacy of cancer immunotherapy in a B16-F10 xenograft model. Our findings reveal the prominent role of the zDHHC8–GPX4 axis in regulating ferroptosis and highlight the potential application of zDHHC8 inhibitors in anticancer therapy.
- Open Access
- 6 June 2024
- Published by Springer Nature in npj Microgravity
- Vol. 10 (1) , 1-8
Cold atom microwave clock based on intracavity cooling in China space station
Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.
- 6 June 2024
- Published by Springer Nature in npj Microgravity
- Vol. 10 (1) , 1-8
Open AccessCold atom microwave clock based on intracavity cooling in China space station
Atomic clocks with higher frequency stability and accuracy than traditional space-borne atomic clocks are the cornerstone of long-term autonomous operation of space-time-frequency systems. We proposed a space cold atoms clock based on an intracavity cooling scheme, which captures cold atoms at the center of a microwave cavity and then executes in situ interactions between the cold atoms and microwaves. As a result of the microgravity environment in space, the cold atoms can interact with the microwaves for a longer time, which aids in realizing a high-precision atomic clock in space. This paper presents the overall design, operational characteristics, and reliability test results of the space atomic clock based on the intracavity cooling scheme designed for the operation onboard the China space station. In addition, the engineering prototype performance of the space cold atoms microwave clock is also presented. The ground test results for the clock show a fractional frequency stability of 1.1 × 10−12 τ−1/2 reaching 2.5 × 10−15 at 200,000 s, providing solid technical and data support for its future operation in orbit.
- 1 January 2023
- Published by IOP Publishing in Chinese Physics B
- Vol. 32 (1) , 013202
Integrated, reliable laser system for an 87Rb cold atom fountain clock
We designed, assembled, and tested a reliable laser system for 87Rb cold atom fountain clocks. The laser system is divided into four modules according to function, which are convenient for installing, adjusting, maintaining, and replacing of the modules. In each functional module, all optical components are fixed on a baseplate with glue and screws, ensuring the system’s structural stability. Mechanical stability was verified in a 6.11g RMS randomvibration test, where the change in output power before and after vibration was less than 5%. Thermal stability was realized by optimizing of the structure and appropriate selection of component materials of the modules through thermal simulation. In the laser splitting and output module, the change in laser power was less than 20% for each fiber in thermal cycles from 5 °C to 43 °C. Finally, the functionality of the laser system was verified for a rubidium fountain clock.
- 1 January 2023
- Published by IOP Publishing in Chinese Physics B
- Vol. 32 (1) , 013202
Integrated, reliable laser system for an 87Rb cold atom fountain clock
We designed, assembled, and tested a reliable laser system for 87Rb cold atom fountain clocks. The laser system is divided into four modules according to function, which are convenient for installing, adjusting, maintaining, and replacing of the modules. In each functional module, all optical components are fixed on a baseplate with glue and screws, ensuring the system’s structural stability. Mechanical stability was verified in a 6.11g RMS randomvibration test, where the change in output power before and after vibration was less than 5%. Thermal stability was realized by optimizing of the structure and appropriate selection of component materials of the modules through thermal simulation. In the laser splitting and output module, the change in laser power was less than 20% for each fiber in thermal cycles from 5 °C to 43 °C. Finally, the functionality of the laser system was verified for a rubidium fountain clock.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 054702
Design and operation of a transportable 87Rb atomic fountain clock
A transportable fountain clock with high reliability is important for high-precision time-frequency measurements. Because of its relatively small cold atoms’ collision frequency shift and ease of attaining high quantum state preparation efficiency, the rubidium atomic fountain clock has an indicated higher stability and reliability. This paper reports the design and operation of a transportable rubidium atomic fountain clock developed by the Shanghai Institute of Optical and Fine Mechanics, Chinese Academy of Science. After being transported more than 1000 km from Shanghai to the Changping Campus of the National Institute of Metrology, China, the optical platform and other hardware of the fountain clock did not need to be adjusted. The rubidium fountain clock maintained a stability of 4.0 × 10−13τ1/2, reaching 5.0 × 10−16 at 300 000 s. After transportation, the rubidium fountain clock and a cesium fountain clock (NIM5) were operated together against the reference frequency of a hydrogen maser. In three separate operating periods, over a total of nearly three months, the average frequency repeatability of the rubidium fountain was less than 3.8 × 10−15.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 054702
Design and operation of a transportable 87Rb atomic fountain clock
A transportable fountain clock with high reliability is important for high-precision time-frequency measurements. Because of its relatively small cold atoms’ collision frequency shift and ease of attaining high quantum state preparation efficiency, the rubidium atomic fountain clock has an indicated higher stability and reliability. This paper reports the design and operation of a transportable rubidium atomic fountain clock developed by the Shanghai Institute of Optical and Fine Mechanics, Chinese Academy of Science. After being transported more than 1000 km from Shanghai to the Changping Campus of the National Institute of Metrology, China, the optical platform and other hardware of the fountain clock did not need to be adjusted. The rubidium fountain clock maintained a stability of 4.0 × 10−13τ1/2, reaching 5.0 × 10−16 at 300 000 s. After transportation, the rubidium fountain clock and a cesium fountain clock (NIM5) were operated together against the reference frequency of a hydrogen maser. In three separate operating periods, over a total of nearly three months, the average frequency repeatability of the rubidium fountain was less than 3.8 × 10−15.
- 1 January 2021
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 19 (12) , 120201
Uncertainty evaluation of the second-order Zeeman shift of a transportable 87Rb atomic fountain clock
In this article, taking advantage of the special magnetic shieldings and the optimal coil design of a transportable Rb atomic fountain clock, the intensity distribution in space and the fluctuations with time of the quantization magnetic field in the Ramsey region were measured using the atomic magneton-sensitive transition method. In an approximately 310 mm long Ramsey region, a peak-to-peak magnetic field intensity of a 0.74 nT deviation in space and a 0.06 nT fluctuation with time were obtained. These results correspond to a second-order Zeeman frequency shift of approximately . This is an essential step in advancing the total frequency uncertainty of the fountain clock to the order of .- 1 January 2021
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 19 (12) , 120201
Uncertainty evaluation of the second-order Zeeman shift of a transportable 87Rb atomic fountain clock
In this article, taking advantage of the special magnetic shieldings and the optimal coil design of a transportable Rb atomic fountain clock, the intensity distribution in space and the fluctuations with time of the quantization magnetic field in the Ramsey region were measured using the atomic magneton-sensitive transition method. In an approximately 310 mm long Ramsey region, a peak-to-peak magnetic field intensity of a 0.74 nT deviation in space and a 0.06 nT fluctuation with time were obtained. These results correspond to a second-order Zeeman frequency shift of approximately . This is an essential step in advancing the total frequency uncertainty of the fountain clock to the order of .- Open Access
- 31 August 2020
- Published by Oxford University Press (OUP) in National Science Review
- Vol. 7 (12) , 1828-1836
Development of a space cold atom clock
Atomic clocks with cold atoms play important roles in the field of fundamental physics as well as primary frequency standards. Operating such cold atom clocks in space paves the way for further exploration in fundamental physics, for example dark matter and general relativity. We developed a space cold atom clock (SCAC), which was launched into orbit with the Space Lab TG-2 in 2016. Before it deorbited with TG-2 in 2019, the SCAC had been working continuously for almost 3 years. During the period in orbit, many scientific experiments and engineering tests were performed. In this article, we summarize the principle, development and in-orbit results. These works provide the basis for construction of a space-borne time-frequency system in deep space.
- 31 August 2020
- Published by Oxford University Press (OUP) in National Science Review
- Vol. 7 (12) , 1828-1836
Open AccessDevelopment of a space cold atom clock
Atomic clocks with cold atoms play important roles in the field of fundamental physics as well as primary frequency standards. Operating such cold atom clocks in space paves the way for further exploration in fundamental physics, for example dark matter and general relativity. We developed a space cold atom clock (SCAC), which was launched into orbit with the Space Lab TG-2 in 2016. Before it deorbited with TG-2 in 2019, the SCAC had been working continuously for almost 3 years. During the period in orbit, many scientific experiments and engineering tests were performed. In this article, we summarize the principle, development and in-orbit results. These works provide the basis for construction of a space-borne time-frequency system in deep space.
- Open Access
- 1 January 2019
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 17 (8) , 080201
Optimization of temperature characteristics of a transportable 87Rb atomic fountain clock
A high-performance transportable fountain clock is attractive for use in laboratories with high-precision time-frequency measurement requirements. This Letter reports the improvement of the stability of a transportable rubidium-87 fountain clock because of an optimization of temperature characteristics. This clock integrates its physical packaging, optical benches, microwave frequency synthesizers, and electronic controls onto an easily movable wheeled plate. Two optical benches with a high-vibration resistance are realized in this work. No additional adjustment is required after moving them several times. The Allan deviation of the fountain clock frequency was measured by comparing it with that of the hydrogen maser. The fountain clock got a short-term stability of at 1 s and long-term stability on the order of 10 16 at 100,000 s.- 1 January 2019
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 17 (8) , 080201
Open AccessOptimization of temperature characteristics of a transportable 87Rb atomic fountain clock
A high-performance transportable fountain clock is attractive for use in laboratories with high-precision time-frequency measurement requirements. This Letter reports the improvement of the stability of a transportable rubidium-87 fountain clock because of an optimization of temperature characteristics. This clock integrates its physical packaging, optical benches, microwave frequency synthesizers, and electronic controls onto an easily movable wheeled plate. Two optical benches with a high-vibration resistance are realized in this work. No additional adjustment is required after moving them several times. The Allan deviation of the fountain clock frequency was measured by comparing it with that of the hydrogen maser. The fountain clock got a short-term stability of at 1 s and long-term stability on the order of 10 16 at 100,000 s. - 1 January 2019
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 68 (13) , 130701-130701-10
Online learning method based on artificial neural network to optimize magnetic shielding characteristic parameters
磁屏蔽在磁场敏感的装置如原子钟、原子干涉仪等精密设备中发挥重要的作用, 在变化外磁场下的某个磁屏蔽内部剩余磁场, 可以通过Jiles-Atherton磁滞模型和磁屏蔽系数计算得出, 根据计算结果可以进行主动补偿来抵消内部磁场的改变. 然而实际应用中磁滞模型中五个与磁屏蔽相关的参数以及磁场衰减的两个参数的准确值的获得是比较困难的, 通常根据实测磁滞回线人工匹配调节参数会花费大量时间且很难确保最终参数是全局最优值. 基于人工神经网络的机器学习方法已经成为一种对复杂模型进行参数优化的有效手段, 得益于现代计算机强大的运算能力, 该过程通常远远快于人工参数调节, 并有更大概率找到全局最优值, 获得优于手工调节的参数值. 本文利用人工神经网络在线机器学习的方法, 对磁滞模型的五个参数与磁屏蔽的另外两个屏蔽相关参数进行优化测定, 并对模拟卫星磁场环境下磁屏蔽内剩余磁场进行预测. 通过实际测量屏蔽筒内剩余磁场与预测值比对, 发现通过机器学习方法得到的磁屏蔽特性参数优于手动找到的参数, 且所用时间大大缩短. 该结果不仅有助于更好地进行磁场补偿, 用于冷原子系统参数优化调整, 更重要的是验证了神经网络在多参数物理系统中的应用, 可以使其他多参数共同作用的物理实验进行最优参数的快速确定.
- 1 January 2019
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 68 (13) , 130701-130701-10
Online learning method based on artificial neural network to optimize magnetic shielding characteristic parameters
磁屏蔽在磁场敏感的装置如原子钟、原子干涉仪等精密设备中发挥重要的作用, 在变化外磁场下的某个磁屏蔽内部剩余磁场, 可以通过Jiles-Atherton磁滞模型和磁屏蔽系数计算得出, 根据计算结果可以进行主动补偿来抵消内部磁场的改变. 然而实际应用中磁滞模型中五个与磁屏蔽相关的参数以及磁场衰减的两个参数的准确值的获得是比较困难的, 通常根据实测磁滞回线人工匹配调节参数会花费大量时间且很难确保最终参数是全局最优值. 基于人工神经网络的机器学习方法已经成为一种对复杂模型进行参数优化的有效手段, 得益于现代计算机强大的运算能力, 该过程通常远远快于人工参数调节, 并有更大概率找到全局最优值, 获得优于手工调节的参数值. 本文利用人工神经网络在线机器学习的方法, 对磁滞模型的五个参数与磁屏蔽的另外两个屏蔽相关参数进行优化测定, 并对模拟卫星磁场环境下磁屏蔽内剩余磁场进行预测. 通过实际测量屏蔽筒内剩余磁场与预测值比对, 发现通过机器学习方法得到的磁屏蔽特性参数优于手动找到的参数, 且所用时间大大缩短. 该结果不仅有助于更好地进行磁场补偿, 用于冷原子系统参数优化调整, 更重要的是验证了神经网络在多参数物理系统中的应用, 可以使其他多参数共同作用的物理实验进行最优参数的快速确定.