AEAbang Annuar Ehsan

Abang Annuar Ehsan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Abang Annuar Ehsan has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electrical performance of water drop energy harvesting device using modified MXene-coated triboelectric nanogenerators

    by Firdaus Jamal Rashid, Muhammad Aniq Shazni Mohammad Haniff, Abang Annuar Ehsan

    Nanogenerators have emerged as promising technologies for sustainable energy harvesting, with water-drop triboelectric nanogenerators (TENGs) showing great potential for operation in water-based environments. However, their energy output remains relatively limited. This study explores the incorporation of alkylammonium-treated MXene as a coating material to enhance the performance of water-drop TENGs. MXene was mixed with PTFE (60 wt% dispersion in H 2 O) to form PTFE/MXene composite solutions with concentrations of 0.01 wt%, 0.05 wt%, and 0.1 wt%. The coatings were applied onto PTFE substrates using the spin-coating method to ensure uniform deposition. Characterization was performed using FTIR, XRD, FESEM, water contact angle (WCA) analysis, and triboelectric performance testing. The results demonstrated that MXene-enhanced coatings significantly improved voltage, current, and power generation compared with uncoated devices. Among all compositions, the 0.01 wt% MXene coating achieved the highest performance, with an average voltage of 14.2 V, current of 20.2 μA, and power of 4.56 μW. The 0.01 wt% MXene-coated device also exhibited excellent durability and stability, maintaining its output after two hours of continuous operation. These findings confirm that MXene incorporation effectively enhances TENG performance and highlight the role of material composition in determining energy output, contributing to the advancement of sustainable triboelectric energy-harvesting technologies.

  • Influence of structural design and electrode configuration on the electrical performance and reliability of polytetrafluoroethylene-based water drop triboelectric nanogenerators

    by Firdaus Jamal Rashid, Abang Annuar Ehsan, Muhammad Aniq Shazni Mohammad Haniff

    The growing environmental concerns associated with conventional fuel-based energy generation have increased the demand for sustainable and green energy solutions. Among these, nanogenerators have emerged as a promising alternative due to their ability to harvest energy from diverse sources, including light, heat, wind, and temperature variations. This study focuses on the development of a triboelectric nanogenerator (TENG) that utilizes water droplets as the primary energy source. The device generates energy through the interaction between water droplets and the TENG surface, enabling efficient conversion via the triboelectric effect. The objective of this work is to investigate the influence of critical device parameters, including electrode configuration and design, electrode material, electrode size, and the thickness of the polytetrafluoroethylene (PTFE) substrate, on the overall electrical performance. The results reveal that an Al–Cu asymmetric electrode in a sandwich configuration, combined with a 1 mm PTFE thickness and a 2 mm electrode size, achieves the best performance with an average voltage of 8.81 V, current of 11.6 µA, and power of 1.68 µW. Furthermore, the device exhibited good reliability, maintaining stable electrical output for over two hours of continuous droplet impact, which highlights its potential for long-term operation. This study demonstrates that device configuration and structural design directly control charge transfer efficiency and electric field strength, thereby governing the overall energy output. The findings provide valuable insights into water droplet-based TENG design and establish a simple, low-cost, and scalable strategy for developing high-performance devices for sustainable energy harvesting and environmental applications.

  • Open Access

    Integrating hetero-core fiber optics sensor in intelligent technological textiles

    by Noor Azie Azura Mohd Arif, Chong Chee Jiun, Yong Wei Sen, Abang Annuar Ehsan

    In the context of the emerging Industry 4.0 paradigm, smart fabric sensors have been representing a novel addition to the textile industry. The proposed sensors utilize macro-bending techniques with varying fiber optic core sizes. The study involved the construction and testing of macro-bending sensors using single-mode (9 μm) and hetero-core (50–9–50 μm) fibers, configured into seven sinusoidal loops. The experiment was further extended to different types of elastic textiles. Spandex demonstrated superior linearity compared with jersey and rubber bands. The integration with the DOIT ESP32 DevKit facilitated real-time monitoring of respiratory rates. The results from the experiment indicated that the macro-bending sensor, fabricated using hetero-core optical fiber, exhibited superior sensitivity in comparison to the sensor assembled from single-mode optical fiber, with respective sensitivity values of 1.72 and 1.30 dB/cm. The designed sensors displayed closely aligned behavior during forward and reverse loading, indicating the reversibility of the fiber optic sensor. Given its simplistic design and low fabrication cost, the proposed sensor holds significant potential for practical applications.

  • Open Access

    Indoor Environmental Quality in Micro & Nanoelectronics Laboratories at IMEN, Research Complex, UKM

    by Mohd Hannas Hosnon, Noor Anilizawatima Sulong, Abang Annuar Ehsan, Khairul Nisha Mohd. Kharuddin

    The National University of Malaysia's Micro and Nanoelectronics laboratories were examined to ascertain their comfort levels. Eight laboratories were chosen as the study locations. This study aims to assess the interior air quality at six locations by measuring CO2, formaldehyde CHOH, total volatile organic compound TVOC, PM2.5, indoor temperature, and relative humidity. The thermal comfort evaluation for labs 1, 2, 3, 4, 5, and 7 is between 20.45 and 22.47 °C, which is below the range of DOSH and Ashrae. While the average readings in laboratories 6 and 8 are within the limits allowed at 23,21 °C and 23,75 °C, respectively. Five laboratories were exceeding the upper limit of RH (30–60%) but only three laboratories were still within the maximum level mentioned by the Ashrae standard. RH exceeded the ICOP limit (60%) at 70.3%, 63.7%, 75.4%, 60.6%, 62.8% and 65.5%, at Lab 1, 2,3,6,7 and 8, respectively, whereas temperature exceeded it (22.5- 26 °C) at 20.45, 22.2, 21.9, 22.43, 21.58 and 22.47 at Lab 1, 2, 3, 4, 5, 7 and 8, respectively. While the average air velocities for all laboratories are 0.17, 0.13, 0.10, 0.16, 0.12, 0.14, 0.15 and 0.09 ms-1, respectively. All the data that has been measured is found to be below the maximum level as recommended by the ASHRAE Standard 55 (2004) of 0.25 ms-1. The indoor air contaminants (CO, CHOH, TVOC, PM2.5, and PM10) met the standard level of ICOP and DOSH except for CHOH approaches ICOP (0.1ppm) at 0.1 and 0.09, at Point 9 and Point 10 for laboratory 3 compared to other laboratories where the concentration obtained is lower. The highest laboratories average concentration of PM2.5 was 13 µg/m3 determined in Lab 3, which was the most actively utilized one because the research activity in this laboratory was working more intensively than the others. As in the study of PM2.5, the highest average PM10 concentration was evaluated in Lab 3 as 36 µg/m3. Based on observations and studies, we find that fresh outdoor air with a complete and good purifier/filter should be used to reduce the concentration of indoor pollutants.


  • Open Access

    Optoelectrical Properties of Hexamine Doped-Methylammonium Lead Iodide Perovskite under Different Grain-Shape Crystallinity

    by Marjoni Imamora Ali Umar, Annisa Zahra Ahdaliza, Salah M. El-Bahy, Nur Aliza, Siti Naqiyah Sadikin, Jaenudin Ridwan, Abang Annuar Ehsan, Mohammed A. Amin, Zeinhom M. El-Bahy, Akrajas Ali Umar

    The crystallinity properties of perovskite influence their optoelectrical performance in solar cell applications. We optimized the grain shape and crystallinity of perovskite film by annealing treatment from 130 to 170 °C under high humidity (relative humidity of 70%). We found that the grain size, grain interface, and grain morphology of the perovskite are optimized when the sample was annealed at 150 °C for 1 h in the air. At this condition, the perovskite film is composed of 250 nm crystalline shape grain and compact inter-grain structure with an invincible grain interface. Perovskite solar cells device analysis indicated that the device fabricated using the samples annealed at 150 °C produced the highest power conversion efficiency, namely 17.77%. The open circuit voltage (Voc), short-circuit current density (Jsc), and fill factor (FF) of the device are as high as 1.05 V, 22.27 mA/cm2, and 0.76, respectively. Optoelectrical dynamic analysis using transient photoluminescence and electrochemical impedance spectroscopies reveals that (i) carrier lifetime in the champion device can be up to 25 ns, which is almost double the carrier lifetime of the sample annealed at 130 °C. (ii) The interfacial charge transfer resistance is low in the champion device, i.e., ~20 Ω, which has a crystalline grain morphology, enabling active photocurrent extraction. Perovskite’s behavior under annealing treatment in high humidity conditions can be a guide for the industrialization of perovskite solar cells.


  • Open Access

    Intensity Loss of ZnO Coated on Fiber Optic

    by Noor Azie Azura Mohd Arif, Sahbudin Shaari, Abang Annuar Ehsan

    Macrobends are optical fiber structures suitable for detecting motion changes. This structure has been developed using single-mode fibers and a combination of single-mode and multimode fibers called hetero-core. In this study, a new macrobending structure was designed and developed by adding a nano-ZnO element to the fiber optic core based on Revolution 4.0. The addition of nanomaterial elements involves an etching process that uses harmful chemicals or high-cost laser technology. Therefore, hetero-core was applied in this study to replace the etching process. The ZnO-coated fiber optics with 10 (ZnO1), 20 (ZnO2), and 30 (ZnO3) times of dip coating were developed using the dip-coating method and characterized using scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) spectroscopy. Sensitivity measurement was conducted with glued optical fiber in the form of bending using a tape with a bending dimension of 2.5 cm × 1.5 cm and a wavelength of 1,550 nm. Morphological characterization using SEM proves that nanoparticles are attached to the optical fiber, and the EDX characterization confirms that the nanoparticles are ZnO elements. Optical fiber sensor sensitivity using core sizes 9, 50–9–50, 50–9–50 (ZnO1), 50–9–50 (ZnO2), and 50–9–50 (ZnO3) achieved sensitivity values of 0.91, 1.61, 2.98, 3.34, and 3.51, respectively. This study successfully produced ZnO-coated optical fiber sensors with a hetero-core structure without performing the etching process and successfully increased the sensitivity of the sensors.


  • Sensitivity optimization of U-shaped fiber optics based on the Taguchi method

    by Noor Azie Azura Mohd Arif, Abang Annuar Ehsan

    The structure of macrobending fiber optics is an ideal structure for constructing fiber optic sensors. This study presents a new design and implementation of U-shaped fiber optics. The basic geometric parameters of U-shaped fiber optics, such as dimension size or curve radius, are analyzed. The Taguchi method was used to optimize the effects of the control and noise factors with respect to dimension size, loop, wavelength, and core size. The control factors were varied at different levels to achieve a novel sensitivity response optimization of the wavelength and core size. The quality characteristics of the signal-to-noise ratio (larger-the-better characteristics) were used to determine the effect of the control parameters in the data analysis. The data of the sensitivity response was analyzed to predict the performance of the U-shaped fiber optics. Results indicate that, by using the Taguchi method, the best control factor setting involves 2.5 cm × 1.5 cm (dimension size) and 1550 nm (wavelength). The percentage contribution of wavelength is the highest at 67.17%, followed by dimension size (13.31%) and number of loops (11.72%) for the fiber optic core size of 50–9–50 μm. For the 9 μm single-mode fiber optics, the corresponding percentages are 61.48%, 16.64%, and 12.81% for wavelength, dimension size, and number of loops, respectively. The Taguchi methodology is suitable for designing sensor geometry.


  • Open Access

    Sensitivity Enhancement of Heterocore Macrobend Fiber Optics by Adding a ZnO Film

    by Noor Azie Azura Mohd Arif, Dilla Duryha Berhanuddin, Abang Annuar Ehsan

    Optical fibers with high sensitivity are in demand due to their great potential in sensor application. Semiconductors, such as ZnO, are good materials. Using them as a second cladding offers opportunities in realizing next-generation multimaterial fiber optics. COMSOL Multiphysics is used to simulate heterocore macrobend fiber optics with the same curvature radius but different values of refractive index and thickness of ZnO films. The optimum thickness of ZnO films is identified by determining the loss of optical fibers. Macrobend heterocore fiber optics by adding ZnO thin film has been established by simulating and interpreting the relationship in terms of transmission and refractive index in the evanescent field. These results will provide a reliable fundamental to guide the performance in practice.


  • Open Access

    Micro Milling Process for the Rapid Prototyping of Microfluidic Devices

    by Muhammad Syafiq Rahim, Abang Annuar Ehsan

    Micro milling process has become an attractive method for the rapid prototyping of micro devices. The process is based on subtractive manufacturing method in which materials from a sample are removed selectively. A comprehensive review on the fabrication of circular and rectangular cross-section channels of microfluidic devices using micro milling process is provided this review work. Process and machining parameters such as micro-tools selection, spindle speed, depth of cut, feed rate and strategy for process optimization will be reviewed. A case study on the rapid fabrication of a rectangular cross section channel of a microflow cytometer device with 200 um channel width and 50 um channel depth using CNC micro milling process is provided. The experimental work has produced a low surface roughness micro channel of 20 nm in roughness and demonstrated a microflow cytometer device that can produce hydrodynamic focusing with a focusing width of about 60 um.


  • Bend loss fiber optics design based on sinusoidal and ellipse configurations

    by Noor Azie Azura Mohd Arif, Dilla Durhya Burhanuddin, Sahbudin Shaari, Abang Annuar Ehsan