DEDaniel Eisenson

Daniel Eisenson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniel Eisenson has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    What's Hot and What's New in Xenotransplantation From the Young Investigator Committee of the IXA–Clinical Science

    by Daniel Eisenson, Emilien Seizilles de Mazancourt, Joseph Ladowski, Evelyn J. Salvaris, Konrad Fischer, Antonio Citro, Liaoran Wang, Alessia Giarraputo, Margaret R. Connolly, Alban E. Longchamp, et al.

    The 2025 International Xenotransplantation Association (IXA) Congress in Geneva, convened in parallel with World Health Organization meetings on xenotransplantation guidance, marked a transition in clinical xenotransplantation from demonstrating that pig organs can function in humans to defining how graft injury is detected, interpreted, and managed in real time. We synthesize the major clinical themes that emerged from the meeting across kidney, heart, liver, and lung xenotransplantation. In kidney xenotransplantation, the NYU and Massachusetts General Hospital living‐recipient experiences now delineate two complementary injury patterns—antibody‐ and complement‐driven with a membranoproliferative, IgA‐positive, innate‐rich phenotype, and T cell–mediated with persistent innate immune activation—both converging on macrophage and NK‐cell biology that conventional immunosuppression does not address. The first registration‐supporting Phase 1/2/3 trial of a 10‐gene‐edited xenokidney (EXPAND) has begun, framed by IXA position‐paper recommendations and supported by recent FDA approvals. In cardiac xenotransplantation, real‐time complement‐function monitoring, global longitudinal strain, and donor‐derived cell‐free DNA emerge as an actionable surveillance toolkit, while other allotransplant biomarkers translate poorly. In liver xenotransplantation, extracorporeal cross‐circulation and the first preliminary data describing auxiliary pig‐to‐human liver transplant (171‐day survival) position porcine livers as bridge‐support platforms rather than definitive replacements. Lung xenotransplantation remains confined to ex vivo perfusion and short‐term preclinical models. Cross‐cutting priorities include donor‐pig design and individual graft phenotyping that accounts for transgene expression heterogeneity, prospectively validated multimodal monitoring, management of nephrotic‐range proteinuria and associated urinary loss of biologic immunosuppressants, and dedicated registry, ethical, and patient‐engagement infrastructure to support trustworthy clinical expansion.

  • Inhibition of Porcine Cytomegalovirus/Porcine Roseolovirus (PCMV/PRV) replication with antiviral compounds

    by H. Mei, A. Chelladurai, S.N. Atkinson, R. Avery, K. Yamada, D. Eisenson, R. Arav-Boger


  • Investigational New Drug Enabling Nonclinical Study of Xenogeneic Life‐Supporting Porcine Kidneys With 10 Gene Edits (10 GE) in a Nonhuman Primate Test System

    by Daniel L. Eisenson, Alexander C. Schulick, WeiLi Chen, Michelle R. Santillan, Michael Cole, Yu Hisadome, Kasra Shirini, Du Gu, Vina Nguyen, Yusuf Ciftci, et al.

    This Investigational New Drug (IND) enabling study evaluated life‐supporting kidney xenotransplantation using porcine source animals with 10 gene edits (10 GE) in a nonhuman primate (NHP) test system. Twelve baboons received xenografts with either calcineurin inhibitor (CNI)‐based or CD40/154 costimulation blockade immunosuppression. Source‐specific screening prevented early xenograft antibody‐mediated rejection in recipients, and clinically relevant preservation with hypothermic machine perfusion‐maintained xenograft viability after off‐site procurement at a high health herd facility. No zoonotic infections were detected. Six of 12 recipients achieved survival >3 months without evidence of cell‐ or antibody‐mediated rejection. CNI‐based regimens were well‐tolerated and achieved the longest survivals to date using this approach, contingent on maintenance of therapeutic drug levels. However, xenograft loss among recipients of each immunosuppression regimen was associated with complement activation and microangiopathy, despite 10 GE Xenokidney expression of h CD46 and h CD55 . Complement activation, potentially worsened by infection‐related inflammation, may lead to long‐term 10 GE Xenokidney failure.


  • Open Access

    Hypothermic machine perfusion prevents hyperacute graft loss in pig-to-primate kidney xenotransplantation after 5-hours of cold Ischemia

    by Yu Hisadome, Daniel L. Eisenson, WeiLi Chen, Alexander C. Schulick, Adam Luo, Michelle R. Santillan, Kelly Casella, Du Gu, Mitsuhiro Sekijima, Hisashi Sahara, et al.

    Xenotransplantation (XTx) is a promising strategy to address the organ shortage. Clinical application will likely require off-site procurement from designated pathogen-free (DPF) facilities, introducing unavoidable cold ischemic time (CIT). The impact of CIT and organ preservation method on graft function in XTx remains unclear. We evaluated eight cases of pig-to-baboon kidney xenotransplantation performed after five hours of CIT, comparing static cold storage (SCS) to hypothermic machine perfusion (HMP) preservation. Outcomes were assessed relative to six additional pig-to-baboon transplants performed with minimal CIT. All grafts preserved with SCS experience hyperacute rejection within 90 min of reperfusion, even in recipients with low levels of preformed anti-pig antibodies. In contrast, all HMP-preserved grafts reperfuse without clinical evidence of injury and maintain function for more than 14 days. Grafts transplanted with minimal CIT show similarly favorable outcomes. Porcine kidneys are highly sensitive to ischemia-reperfusion injury after cold preservation across xenogeneic barriers. Routine SCS leads to early graft failure, while HMP mitigates ischemic injury and may enable successful clinical XTx despite prolonged CIT.


  • Open Access

    Routine cold storage leads to hyperacute graft loss in pig-to-primate kidney xenotransplantation; hypothermic machine perfusion may be preferred preservation modality in xenotransplantation

    by Kazuhiko Yamada, Yu Hisadome, Daniel Eisenson, WeiLi Chen, Alex Schulick, Michelle Santillan, Adam Luo, Kelly Casella, Du Gu, Mitsuhiro Sekijima, et al.

    Xenotransplantation (XTx) is an increasingly realistic solution to the organ shortage. Clinical XTx may require off-site procurement in a designated pathogen free (DPF) facility necessitating a period of cold ischemic time during transportation. This study evaluates the impact of different kidney preservation strategies on early graft function in pig-to-baboon XTx in a series of eight cases of pig-to-baboon xenotransplantation performed after five hours of cold ischemic time and compares these results to six cases of pig-to-baboon xenotransplantation performed with minimal ischemic time. Our data indicates that porcine kidneys appear to be particularly sensitive to IRI after cold preservation, especially across xenogeneic barriers, and routine static cold storage leads to hyperacute graft loss even in recipients with low levels of preformed antibodies. Hypothermic machine perfusion minimizes IRI and may prevent early xenograft loss.


  • Top Cited Papers
    Open Access

    Physiological basis for xenotransplantation from genetically modified pigs to humans

    by Leigh Peterson, Magdi H. Yacoub, David Ayares, Kazuhiko Yamada, Daniel Eisenson, Bartley P. Griffith, Muhammad M. Mohiuddin, Willard Eyestone, J. Craig Venter, Ryszard T. Smolenski, et al.

    The collective efforts of scientists over multiple decades have led to advancements in molecular and cellular biology-based technologies including genetic engineering and animal cloning that are now being harnessed to enhance the suitability of pig organs for xenotransplantation into humans. Using organs sourced from pigs with multiple gene deletions and human transgene insertions, investigators have overcome formidable immunological and physiological barriers in pig-to-nonhuman primate (NHP) xenotransplantation and achieved prolonged pig xenograft survival. These studies informed the design of Revivicor’s (Revivicor Inc, Blacksburg, VA) genetically engineered pigs with 10 genetic modifications (10 GE) (including the inactivation of 4 endogenous porcine genes and insertion of 6 human transgenes), whose hearts and kidneys have now been studied in preclinical human xenotransplantation models with brain-dead recipients. Additionally, the first two clinical cases of pig-to-human heart xenotransplantation were recently performed with hearts from this 10 GE pig at the University of Maryland. Although this review focuses on xenotransplantation of hearts and kidneys, multiple organs, tissues, and cell types from genetically engineered pigs will provide much-needed therapeutic interventions in the future.


  • Top Cited Papers
    Open Access

    Consistent survival in consecutive cases of life-supporting porcine kidney xenotransplantation using 10GE source pigs

    by Daniel Eisenson, Yu Hisadome, Michelle Santillan, Hayato Iwase, WeiLi Chen, Akira Shimizu, Alex Schulick, Du Gu, Armaan Akbar, Alice Zhou, et al.

    Xenotransplantation represents a possible solution to the organ shortage crisis and is an imminent clinical reality with long-term xenograft survival in pig-to-nonhuman primate (NHP) heart and kidney large animal models, and short-term success in recent human decedent and clinical studies. However, concerns remain about safe clinical translation of these results, given the inconsistency in published survival as well as key differences between preclinical procurement and immunosuppression and clinical standards-of-care. Notably, no studies of solid organ pig-to-NHP transplantation have achieved xenograft survival longer than one month without CD40/CD154 costimulatory blockade, which is not currently an FDA-approved immunosuppression strategy. We now present consistent survival in consecutive cases of pig-to-NHP kidney xenotransplantation, including long-term survival after >3 hours of xenograft cold preservation time as well as long-term survival using FDA-approved immunosuppression. These data provide critical supporting evidence for the safety and feasibility of clinical kidney xenotransplantation. Moreover, long-term survival without CD40/CD154 costimulatory blockade may provide important insights for immunosuppression regimens to be considered for first-in-human clinical trials.


  • Prevalence and consequences of empiric anticoagulation for venous thromboembolism in patients hospitalized for COVID-19: a cautionary tale

    by Daniel L. Eisenson, Oluwafemi P. Owodunni, Brandyn D. Lau, Mujan Varasteh Kia, Peggy S. Kraus, Christine G. Holzmueller, Dauryne L. Shaffer, Michael B. Streiff, Elliott R. Haut