Lara Struelens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lara Struelens has a total of 241 co-authors. Here are the top co-authors by number of shared publications:
Filip Vanhavere
Radiation Protection, Dosimetry and Calibration, Belgian Nuclear Research Centre, Mol, Flanders, BELGIUM
9 shared publications- Hilde Bosmans
Department of Imaging and Pathology, KU Leuven, Leuven, Belgium
6 shared publications C. Koukorava
Division of Licensing and Inspections, Greek Atomic Energy Commission, PO Box 60092, Ag. Paraskevi, Athens 15310, Greece
5 shared publicationsF. Vanhavere
Belgian Nuclear Research Center (SCK CEN), Nuclear Medical Applications, Mol, Belgium
5 shared publicationsE. Carinou
B Dosimetry and Calibration Department, Greek Atomic Energy Commission (EEAE), Agia Paraskevi, Greece
4 shared publications- Filip Vanhavere
European committee for standardization
4 shared publications
Latest Publications
- 6 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (10)
Design, development and characterization of pregnant anthropomorphic phantoms for fetal dose measurements in proton therapy
Objective: Radiotherapy during pregnancy is clinically challenging due to concerns about fetal radiation exposure. Proton therapy (PT) with pencil beam scanning can reduce out-of-field dose compared with photon therapy; however, secondary neutron production requires accurate fetal dosimetry. Approach: This study presents the design, material characterization, and computational modeling of two anatomically realistic pregnant anthropomorphic phantoms, MaTORI10 and MaTORI30, representing 10 and 30 weeks of gestation and developed for fetal dose assessment in PT. Candidate materials for lung, soft tissue, and bone—including commercial phantom materials, QA materials, and novel 3D-printed or castable polymers—were evaluated using MCNP 6.2 Monte Carlo simulations and compared with reference pregnant-tissue compositions. Depth–dose distributions, neutron yields, and out-of-field neutron spectra were analyzed to characterize radiological behavior. Suitable materials were implemented in physical phantoms constructed by integrating 3D-printed components and cast bone into an ATOM® female phantom. Pregnancy geometries from the University of Florida pregnant phantom library were merged with ATOM CT and surface scans to generate anatomically realistic models with detector inserts. Voxelized computational versions were generated from CT and surface scans and implemented in TOPAS 3.8. A virtual PT brain irradiation plan (78–116 MeV, 10 cm range SOBP, 5 cm modulation, 3 cm radius), with and without a range shifter (RS), was used to quantify in-field and fetal doses. Main Results: Material testing showed substantial variability, primarily driven by differences in hydrogen content and density. Both phantoms were successfully constructed and validated by CT imaging. For MaTORI30, modeled fetal dose was on average 29% higher without RS and 21% higher with RS compared to reference materials; for MaTORI10, increases of 10% and 18% were observed. Significance: The MaTORI10 and MaTORI30 phantoms provide the first anatomically detailed, pregnant anthropomorphic phantoms whose tissue-equivalent properties were computationally characterized for fetal dose assessment in PT. These phantoms provide a platform for experimental and Monte Carlo-based assessment of fetal dose, facilitating safer radiotherapy and optimal planning for pregnant patients.
- 6 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (10)
Design, development and characterization of pregnant anthropomorphic phantoms for fetal dose measurements in proton therapy
Objective: Radiotherapy during pregnancy is clinically challenging due to concerns about fetal radiation exposure. Proton therapy (PT) with pencil beam scanning can reduce out-of-field dose compared with photon therapy; however, secondary neutron production requires accurate fetal dosimetry. Approach: This study presents the design, material characterization, and computational modeling of two anatomically realistic pregnant anthropomorphic phantoms, MaTORI10 and MaTORI30, representing 10 and 30 weeks of gestation and developed for fetal dose assessment in PT. Candidate materials for lung, soft tissue, and bone—including commercial phantom materials, QA materials, and novel 3D-printed or castable polymers—were evaluated using MCNP 6.2 Monte Carlo simulations and compared with reference pregnant-tissue compositions. Depth–dose distributions, neutron yields, and out-of-field neutron spectra were analyzed to characterize radiological behavior. Suitable materials were implemented in physical phantoms constructed by integrating 3D-printed components and cast bone into an ATOM® female phantom. Pregnancy geometries from the University of Florida pregnant phantom library were merged with ATOM CT and surface scans to generate anatomically realistic models with detector inserts. Voxelized computational versions were generated from CT and surface scans and implemented in TOPAS 3.8. A virtual PT brain irradiation plan (78–116 MeV, 10 cm range SOBP, 5 cm modulation, 3 cm radius), with and without a range shifter (RS), was used to quantify in-field and fetal doses. Main Results: Material testing showed substantial variability, primarily driven by differences in hydrogen content and density. Both phantoms were successfully constructed and validated by CT imaging. For MaTORI30, modeled fetal dose was on average 29% higher without RS and 21% higher with RS compared to reference materials; for MaTORI10, increases of 10% and 18% were observed. Significance: The MaTORI10 and MaTORI30 phantoms provide the first anatomically detailed, pregnant anthropomorphic phantoms whose tissue-equivalent properties were computationally characterized for fetal dose assessment in PT. These phantoms provide a platform for experimental and Monte Carlo-based assessment of fetal dose, facilitating safer radiotherapy and optimal planning for pregnant patients.
- 2 December 2025
- Published by Elsevier in Physica Medica
- Vol. 140, 105685
Considerations on dose constraints in interventional cardiology – first approach to establishing dose constraints
- 2 December 2025
- Published by Elsevier in Physica Medica
- Vol. 140, 105685
Considerations on dose constraints in interventional cardiology – first approach to establishing dose constraints
- 1 December 2025
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 45 (4) , 041519
Interactive posture program: a software platform for using the realistic anthropomorphic flexible phantom family in computational dosimetry applications
Boundary-representation (B-Rep) computational phantoms (CPs) offer high flexibility and anatomical accuracy, making them valuable tools in dosimetry and medical imaging simulations. However, their complexity and the need for expertise in graphic modelling limit their accessibility and adoption. Moreover, most Monte Carlo (MC) particle transport codes lack native support for B-Rep geometries, requiring complex and non-automated conversion to compatible formats, further complicating their use. To address these challenges, we developed the interactive posture program (IPP), a software platform to ease the use of B-Rep phantoms. The IPP features a real-time three-dimensional (3D) graphical interface, allowing users to easily create individualised phantoms and realistic exposure scenarios. Currently, the IPP includes three flexible phantoms—Adult Male, Adult Female, and 1-year-old Female—from the realistic anthropomorphic flexible (RAF) family, which can be extensively customised using integrated morphing tools to simulate diverse anatomical variations. Additionally, the IPP provides a comprehensive library of predefined exposure scenarios and advanced geometry creation tools, which allow the creation of accurate and individualised simulations. Finally, the IPP automatically generates simulation input files compatible with the most widely used MC transport codes, significantly simplifying the use of B-Rep phantoms within dosimetry and imaging simulations.
- 1 December 2025
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 45 (4) , 041519
Interactive posture program: a software platform for using the realistic anthropomorphic flexible phantom family in computational dosimetry applications
Boundary-representation (B-Rep) computational phantoms (CPs) offer high flexibility and anatomical accuracy, making them valuable tools in dosimetry and medical imaging simulations. However, their complexity and the need for expertise in graphic modelling limit their accessibility and adoption. Moreover, most Monte Carlo (MC) particle transport codes lack native support for B-Rep geometries, requiring complex and non-automated conversion to compatible formats, further complicating their use. To address these challenges, we developed the interactive posture program (IPP), a software platform to ease the use of B-Rep phantoms. The IPP features a real-time three-dimensional (3D) graphical interface, allowing users to easily create individualised phantoms and realistic exposure scenarios. Currently, the IPP includes three flexible phantoms—Adult Male, Adult Female, and 1-year-old Female—from the realistic anthropomorphic flexible (RAF) family, which can be extensively customised using integrated morphing tools to simulate diverse anatomical variations. Additionally, the IPP provides a comprehensive library of predefined exposure scenarios and advanced geometry creation tools, which allow the creation of accurate and individualised simulations. Finally, the IPP automatically generates simulation input files compatible with the most widely used MC transport codes, significantly simplifying the use of B-Rep phantoms within dosimetry and imaging simulations.
- 9 October 2025
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 45 (4) , 041502
Computational system for extremity dosimetry in nuclear medicine
The goal of this research is to create a computational dosimetry system to monitor the dose received by nuclear medicine workers on their extremities. The system creates multiple Monte Carlo simulations to assess the dose received in different sections of the hands. Each simulation is created based on depth camera images of the manipulation of radioactive sources, using digital twins to represent the hands of the worker and the radiation source. The position of the hands and the source is constantly recalculated using computer vision algorithms. In this paper, we explain the different components of the computational system, assessing the possible sources of uncertainty introduced by each component. As a proof of concept, we compared the dose estimated by the computational system with real dosimeter measurements for two different scenarios. The simulated dose was, on average, 51% of the measured dose.
- 9 October 2025
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 45 (4) , 041502
Computational system for extremity dosimetry in nuclear medicine
The goal of this research is to create a computational dosimetry system to monitor the dose received by nuclear medicine workers on their extremities. The system creates multiple Monte Carlo simulations to assess the dose received in different sections of the hands. Each simulation is created based on depth camera images of the manipulation of radioactive sources, using digital twins to represent the hands of the worker and the radiation source. The position of the hands and the source is constantly recalculated using computer vision algorithms. In this paper, we explain the different components of the computational system, assessing the possible sources of uncertainty introduced by each component. As a proof of concept, we compared the dose estimated by the computational system with real dosimeter measurements for two different scenarios. The simulated dose was, on average, 51% of the measured dose.
- Open Access
- 13 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105049
Radiation protection in proton therapy: Insights from a multi-institutional survey and experimental measurements within the SINFONIA project
- 13 August 2025
- Published by Elsevier in Physica Medica
- Vol. 137, 105049
Open AccessRadiation protection in proton therapy: Insights from a multi-institutional survey and experimental measurements within the SINFONIA project
- 25 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (16)
Analysis of the mixed secondary radiation field in proton therapy using a Timepix detector
Objective: One major advantage of proton therapy (PT) over conventional photon radiotherapy is reduced dose delivered to normal tissue. However, the complexity of the secondary radiation field composed of a mixture of particles with a wide energy range makes its characterization a challenging task. Approach: Measurements with a miniaturized Timepix detector were carried out in three positions out-of-field (7.4 cm, 14.1 cm, and 18.5 cm from the isocenter), inside a phantom resembling a 5 year old undergoing proton pencil beam scanning treatment for a brain tumor. Total and particle-specific deposited energy, absorbed dose, and dose equivalent in water were calculated. Results were compared with thermoluminescent detectors (TLDs) measurements and Monte Carlo (MC) simulations modelling the experimental setup. Main results: The proton absorbed dose in water normalized to the target dose, ranged from 4.8 mGy/Gy to 65.5 µGy/Gy, while the gamma dose, which remained consistently lower, ranged between 88.4 µGy/Gy and 6.1 µGy/Gy. The measured dose equivalent varied between 6.3 mSv/Gy and 82.3 µSv/Gy. Good agreement was observed for the two farthest-locations when comparing the absorbed dose in water estimated by the MiniPIX Timepix detector with TLD measurements and MC simulations. However, the closest position showed an overestimation for both the absorbed dose and the dose equivalent, while the farthest position exhibited an underestimation for the dose equivalent. Significance: Out-of-field dosimetry in proton therapy is challenging due to the complexity of the secondary mixed radiation field. Multiple detectors are typically required, but many are too large for use in anthropomorphic phantoms. This study demonstrates that the MiniPIX Timepix detector can accurately determine absorbed dose, dose equivalent and particle-specific contributions (electrons/gammas, protons, and ions). Unlike passive detectors such as TLDs, it enables active measurements with high time resolution, allowing dose rates analysis. The results, validated through experimental data and MC simulations, support the detector’s potential for reliable out-of-field dose assessment and improved patient safety.
- 25 July 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (16)
Analysis of the mixed secondary radiation field in proton therapy using a Timepix detector
Objective: One major advantage of proton therapy (PT) over conventional photon radiotherapy is reduced dose delivered to normal tissue. However, the complexity of the secondary radiation field composed of a mixture of particles with a wide energy range makes its characterization a challenging task. Approach: Measurements with a miniaturized Timepix detector were carried out in three positions out-of-field (7.4 cm, 14.1 cm, and 18.5 cm from the isocenter), inside a phantom resembling a 5 year old undergoing proton pencil beam scanning treatment for a brain tumor. Total and particle-specific deposited energy, absorbed dose, and dose equivalent in water were calculated. Results were compared with thermoluminescent detectors (TLDs) measurements and Monte Carlo (MC) simulations modelling the experimental setup. Main results: The proton absorbed dose in water normalized to the target dose, ranged from 4.8 mGy/Gy to 65.5 µGy/Gy, while the gamma dose, which remained consistently lower, ranged between 88.4 µGy/Gy and 6.1 µGy/Gy. The measured dose equivalent varied between 6.3 mSv/Gy and 82.3 µSv/Gy. Good agreement was observed for the two farthest-locations when comparing the absorbed dose in water estimated by the MiniPIX Timepix detector with TLD measurements and MC simulations. However, the closest position showed an overestimation for both the absorbed dose and the dose equivalent, while the farthest position exhibited an underestimation for the dose equivalent. Significance: Out-of-field dosimetry in proton therapy is challenging due to the complexity of the secondary mixed radiation field. Multiple detectors are typically required, but many are too large for use in anthropomorphic phantoms. This study demonstrates that the MiniPIX Timepix detector can accurately determine absorbed dose, dose equivalent and particle-specific contributions (electrons/gammas, protons, and ions). Unlike passive detectors such as TLDs, it enables active measurements with high time resolution, allowing dose rates analysis. The results, validated through experimental data and MC simulations, support the detector’s potential for reliable out-of-field dose assessment and improved patient safety.
- Open Access
- 14 November 2024
- Published by Springer Nature in EJNMMI Physics
- Vol. 11 (1) , 1-15
How much do 68Ga-, 177Lu- and 131I-based radiopharmaceuticals contribute to the global radiation exposure of nuclear medicine staff?
The radiation exposure of nuclear medicine personnel, especially concerning extremity doses, has been a significant focus over the past two decades. This study addresses the evolving practice of NM, particularly with the rise of radionuclide therapy and theranostic procedures, which involve a variety of radionuclides such as 68Ga, 177Lu, and 131I. Traditional studies have concentrated on common radioisotopes like 99mTc, 18F, and 90Y, but there is limited data on these radionuclides, which are more and more frequently used. This study, part of the European SINFONIA project, aims to fill this gap by providing new dosimetry data through a multicenter approach. The research monitors extremity doses to hands, eye lens doses, and whole-body doses in nuclear medicine staff handling 68Ga, 177Lu, and 131I. It examines the type of activities performed and the protective measures used. The study extrapolates measured doses to annual doses, comparing them with annual dose limits, and assesses the contribution of these specific procedures to the overall occupational dose of nuclear medicine personnel. Measurements were conducted from November 2020 to August 2023 across nine hospitals. The highest whole-body, eye lens and extremity doses were observed for 68Ga. Average maximum extremity doses, normalized per manipulated activity, were found of 6200 µSv/GBq, 30 µSv/GBq and 260 µSV/GBq for 68Ga, 177Lu and 131I, respectively. Average whole-body doses stayed below 60 µSv/GBq for all 3 isotopes and below 200 µSv/GBq for the eye lens dose. The variation in doses also depends on the task performed. For 68Ga there is a risk of reaching the annual dose limit for skin dose during synthesis and dispensing. This study’s measurement campaigns across various European countries have provided new and extensive occupational dosimetry data for nuclear medicine staff handling 68Ga, 177Lu and 131I radiopharmaceuticals. The results indicate that 68Ga contributes significantly to the global occupational dose, despite its relatively low usage compared to other isotopes. Staff working in radiopharmacy hot labs, labeling and dispensing 177Lu contribute less to the finger dose compared to other isotopes.
- 14 November 2024
- Published by Springer Nature in EJNMMI Physics
- Vol. 11 (1) , 1-15
Open AccessHow much do 68Ga-, 177Lu- and 131I-based radiopharmaceuticals contribute to the global radiation exposure of nuclear medicine staff?
The radiation exposure of nuclear medicine personnel, especially concerning extremity doses, has been a significant focus over the past two decades. This study addresses the evolving practice of NM, particularly with the rise of radionuclide therapy and theranostic procedures, which involve a variety of radionuclides such as 68Ga, 177Lu, and 131I. Traditional studies have concentrated on common radioisotopes like 99mTc, 18F, and 90Y, but there is limited data on these radionuclides, which are more and more frequently used. This study, part of the European SINFONIA project, aims to fill this gap by providing new dosimetry data through a multicenter approach. The research monitors extremity doses to hands, eye lens doses, and whole-body doses in nuclear medicine staff handling 68Ga, 177Lu, and 131I. It examines the type of activities performed and the protective measures used. The study extrapolates measured doses to annual doses, comparing them with annual dose limits, and assesses the contribution of these specific procedures to the overall occupational dose of nuclear medicine personnel. Measurements were conducted from November 2020 to August 2023 across nine hospitals. The highest whole-body, eye lens and extremity doses were observed for 68Ga. Average maximum extremity doses, normalized per manipulated activity, were found of 6200 µSv/GBq, 30 µSv/GBq and 260 µSV/GBq for 68Ga, 177Lu and 131I, respectively. Average whole-body doses stayed below 60 µSv/GBq for all 3 isotopes and below 200 µSv/GBq for the eye lens dose. The variation in doses also depends on the task performed. For 68Ga there is a risk of reaching the annual dose limit for skin dose during synthesis and dispensing. This study’s measurement campaigns across various European countries have provided new and extensive occupational dosimetry data for nuclear medicine staff handling 68Ga, 177Lu and 131I radiopharmaceuticals. The results indicate that 68Ga contributes significantly to the global occupational dose, despite its relatively low usage compared to other isotopes. Staff working in radiopharmacy hot labs, labeling and dispensing 177Lu contribute less to the finger dose compared to other isotopes.
- 1 June 2024
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 44 (2) , 021524
Object and person tracking systems to enable extremity dosimetry in nuclear medicine using computational methods
Nuclear medicine (NM) professionals are potentially exposed to high doses of ionising radiation, particularly in the skin of the hands. Ring dosimeters are used by the workers to ensure extremity doses are kept below the legal limits. However, ring dosimeters are often susceptible to large uncertainties, so it is difficult to ensure a correct measurement using the traditional occupational monitoring methods. An alternative solution is to calculate the absorbed dose by using Monte Carlo simulations. This method could reduce the uncertainty in dose calculation if the exact positions of the worker and the radiation source are represented in these simulations. In this study we present a set of computer vision and artificial intelligence algorithms that allow us to track the exact position of unshielded syringes and the hands of NM workers. We showcase a possible hardware configuration to acquire the necessary input data for the algorithms. And finally, we assess the tracking confidence of our software. The tracking accuracy achieved for the syringe detection was 57% and for the hand detection 98%.
- 1 June 2024
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 44 (2) , 021524
Object and person tracking systems to enable extremity dosimetry in nuclear medicine using computational methods
Nuclear medicine (NM) professionals are potentially exposed to high doses of ionising radiation, particularly in the skin of the hands. Ring dosimeters are used by the workers to ensure extremity doses are kept below the legal limits. However, ring dosimeters are often susceptible to large uncertainties, so it is difficult to ensure a correct measurement using the traditional occupational monitoring methods. An alternative solution is to calculate the absorbed dose by using Monte Carlo simulations. This method could reduce the uncertainty in dose calculation if the exact positions of the worker and the radiation source are represented in these simulations. In this study we present a set of computer vision and artificial intelligence algorithms that allow us to track the exact position of unshielded syringes and the hands of NM workers. We showcase a possible hardware configuration to acquire the necessary input data for the algorithms. And finally, we assess the tracking confidence of our software. The tracking accuracy achieved for the syringe detection was 57% and for the hand detection 98%.
- Open Access
- 22 April 2024
- Published by Springer Nature in EJNMMI Physics
- Vol. 11 (1) , 1-17
Joint EURADOS-EANM initiative for an advanced computational framework for the assessment of external dose rates from nuclear medicine patients
Background: In order to ensure adequate radiation protection of critical groups such as staff, caregivers and the general public coming into proximity of nuclear medicine (NM) patients, it is necessary to consider the impact of the radiation emitted by the patients during their stay at the hospital or after leaving the hospital. Current risk assessments are based on ambient dose rate measurements in a single position at a specified distance from the patient and carried out at several time points after administration of the radiopharmaceutical to estimate the whole-body retention. The limitations of such an approach are addressed in this study by developing and validating a more advanced computational dosimetry approach using Monte Carlo (MC) simulations in combination with flexible and realistic computational phantoms and time activity distribution curves from reference biokinetic models. Results: Measurements of the ambient dose rate equivalent Ḣ*(10) at 1 m from the NM patient have been successfully compared against MC simulations with 5 different codes using the ICRP adult reference computational voxel phantoms, for typical clinical procedures with 99mTc-HDP/MDP, 18FDG and Na131I. All measurement data fall in the 95% confidence intervals, determined for the average simulated results. Moreover, the different MC codes (MCNP-X, PHITS, GATE, GEANT4, TRIPOLI-4®) have been compared for a more realistic scenario where the effective dose rate Ė of an exposed individual was determined in positions facing and aside the patient model at 30 cm, 50 cm and 100 cm. The variation between codes was lower than 8% for all the radiopharmaceuticals at 1 m, and varied from 5 to 16% for the face-to face and side-by-side configuration at 30 cm and 50 cm. A sensitivity study on the influence of patient model morphology demonstrated that the relative standard deviation of Ḣ*(10) at 1 m for the range of included patient models remained under 16% for time points up to 120 min post administration. Conclusions: The validated computational approach will be further used for the evaluation of effective dose rates per unit administered activity for a variety of close-contact configurations and a range of radiopharmaceuticals as part of risk assessment studies. Together with the choice of appropriate dose constraints this would facilitate the setting of release criteria and patient restrictions.
- 22 April 2024
- Published by Springer Nature in EJNMMI Physics
- Vol. 11 (1) , 1-17
Open AccessJoint EURADOS-EANM initiative for an advanced computational framework for the assessment of external dose rates from nuclear medicine patients
Background: In order to ensure adequate radiation protection of critical groups such as staff, caregivers and the general public coming into proximity of nuclear medicine (NM) patients, it is necessary to consider the impact of the radiation emitted by the patients during their stay at the hospital or after leaving the hospital. Current risk assessments are based on ambient dose rate measurements in a single position at a specified distance from the patient and carried out at several time points after administration of the radiopharmaceutical to estimate the whole-body retention. The limitations of such an approach are addressed in this study by developing and validating a more advanced computational dosimetry approach using Monte Carlo (MC) simulations in combination with flexible and realistic computational phantoms and time activity distribution curves from reference biokinetic models. Results: Measurements of the ambient dose rate equivalent Ḣ*(10) at 1 m from the NM patient have been successfully compared against MC simulations with 5 different codes using the ICRP adult reference computational voxel phantoms, for typical clinical procedures with 99mTc-HDP/MDP, 18FDG and Na131I. All measurement data fall in the 95% confidence intervals, determined for the average simulated results. Moreover, the different MC codes (MCNP-X, PHITS, GATE, GEANT4, TRIPOLI-4®) have been compared for a more realistic scenario where the effective dose rate Ė of an exposed individual was determined in positions facing and aside the patient model at 30 cm, 50 cm and 100 cm. The variation between codes was lower than 8% for all the radiopharmaceuticals at 1 m, and varied from 5 to 16% for the face-to face and side-by-side configuration at 30 cm and 50 cm. A sensitivity study on the influence of patient model morphology demonstrated that the relative standard deviation of Ḣ*(10) at 1 m for the range of included patient models remained under 16% for time points up to 120 min post administration. Conclusions: The validated computational approach will be further used for the evaluation of effective dose rates per unit administered activity for a variety of close-contact configurations and a range of radiopharmaceuticals as part of risk assessment studies. Together with the choice of appropriate dose constraints this would facilitate the setting of release criteria and patient restrictions.
- 15 March 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (6) , 064001
Biophysical characterization of collimated and uncollimated fields in pencil beam scanning proton therapy
Objective. The lateral dose fall-off in proton pencil beam scanning (PBS) technique remains the preferred choice for sparing adjacent organs at risk as opposed to the distal edge due to the proton range uncertainties and potentially high relative biological effectiveness. However, because of the substantial spot size along with the scattering in the air and in the patient, the lateral penumbra in PBS can be degraded. Combining PBS with an aperture can result in a sharper dose fall-off, particularly for shallow targets. Approach. The aim of this work was to characterize the radiation fields produced by collimated and uncollimated 100 and 140 MeV proton beams, using Monte Carlo simulations and measurements with a MiniPIX-Timepix detector. The dose and the linear energy transfer (LET) were then coupled with published in silico biophysical models to elucidate the potential biological effects of collimated and uncollimated fields. Main results. Combining an aperture with PBS reduced the absorbed dose in the lateral fall-off and out-of-field by 60%. However, the results also showed that the absolute frequency-averaged LET (LETF) values increased by a maximum of 3.5 keV μm−1 in collimated relative to uncollimated fields, while the dose-averaged LET (LETD) increased by a maximum of 7 keV μm−1. Despite the higher LET values produced by collimated fields, the predicted DNA damage yields remained lower, owing to the large dose reduction. Significance. This work demonstrated the dosimetric advantages of combining an aperture with PBS coupled with lower DNA damage induction. A methodology for calculating dose in water derived from measurements with a silicon-based detector was also presented. This work is the first to demonstrate experimentally the increase in LET caused by combining PBS with aperture, and to assess the potential DNA damage which is the initial step in the cascade of events leading to the majority of radiation-induced biological effects.
- 15 March 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (6) , 064001
Biophysical characterization of collimated and uncollimated fields in pencil beam scanning proton therapy
Objective. The lateral dose fall-off in proton pencil beam scanning (PBS) technique remains the preferred choice for sparing adjacent organs at risk as opposed to the distal edge due to the proton range uncertainties and potentially high relative biological effectiveness. However, because of the substantial spot size along with the scattering in the air and in the patient, the lateral penumbra in PBS can be degraded. Combining PBS with an aperture can result in a sharper dose fall-off, particularly for shallow targets. Approach. The aim of this work was to characterize the radiation fields produced by collimated and uncollimated 100 and 140 MeV proton beams, using Monte Carlo simulations and measurements with a MiniPIX-Timepix detector. The dose and the linear energy transfer (LET) were then coupled with published in silico biophysical models to elucidate the potential biological effects of collimated and uncollimated fields. Main results. Combining an aperture with PBS reduced the absorbed dose in the lateral fall-off and out-of-field by 60%. However, the results also showed that the absolute frequency-averaged LET (LETF) values increased by a maximum of 3.5 keV μm−1 in collimated relative to uncollimated fields, while the dose-averaged LET (LETD) increased by a maximum of 7 keV μm−1. Despite the higher LET values produced by collimated fields, the predicted DNA damage yields remained lower, owing to the large dose reduction. Significance. This work demonstrated the dosimetric advantages of combining an aperture with PBS coupled with lower DNA damage induction. A methodology for calculating dose in water derived from measurements with a silicon-based detector was also presented. This work is the first to demonstrate experimentally the increase in LET caused by combining PBS with aperture, and to assess the potential DNA damage which is the initial step in the cascade of events leading to the majority of radiation-induced biological effects.