Shi Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shi Liu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Dong Li
College of Civil Engineering
2 shared publications - Dong Li
School of Civil Engineering, Liaoning Technical University, Fuxin 123000, China
1 shared publication - Haiqing Liu
School of Civil Engineering, Liaoning Technical University, Fuxin, China
1 shared publication - Qing Guo
College of Civil Engineering
1 shared publication - Shuchao Wei
School of Civil Engineering, Liaoning Technical University, Fuxin 123000, China
1 shared publication - Xiaojian Rong
School of Civil Engineering, Liaoning Technical University, Fuxin 123000, China
1 shared publication
Latest Publications
- Open Access
Investigation on Drying Shrinkage of Basalt Fiber-Reinforced Concrete with Coal Gangue Ceramsite as Coarse Aggregates
In order to investigate the basalt fiber influences on drying shrinkage of coal gangue ceramsite concrete, specimens with varying fiber dosages and matrix strength were prepared. The drying shrinkage (DS) was compared. To elucidate the characteristics of the DS, the internal humidity (IH) and electrical resistivity (ER) were also tested. The properties of the variation in the DS, IH, and ER were verified. The correlation between the values of the DS, IH, and ES was systematically analyzed, and a prediction model of DS considering the influence of fiber dosage and coal gangue ceramsite was proposed. The results showed that the incorporation of basalt fiber can significantly reduce the DS, and the value of the DS decreased with the increment of fiber dosage. The value of the DS also decreased with the enhancement of the matrix strength. An inverse relationship existed between the variation in the IH and DS, whereas the variation in the ER demonstrated a direct proportionality with the variation in the DS. The prediction model for the basalt fiber-reinforced coal gangue ceramsite concrete was obtained by modifying the AFREM model. The values predicted by the improved AFREM model demonstrated excellent consistency with the test data.
Open AccessInvestigation on Drying Shrinkage of Basalt Fiber-Reinforced Concrete with Coal Gangue Ceramsite as Coarse Aggregates
In order to investigate the basalt fiber influences on drying shrinkage of coal gangue ceramsite concrete, specimens with varying fiber dosages and matrix strength were prepared. The drying shrinkage (DS) was compared. To elucidate the characteristics of the DS, the internal humidity (IH) and electrical resistivity (ER) were also tested. The properties of the variation in the DS, IH, and ER were verified. The correlation between the values of the DS, IH, and ES was systematically analyzed, and a prediction model of DS considering the influence of fiber dosage and coal gangue ceramsite was proposed. The results showed that the incorporation of basalt fiber can significantly reduce the DS, and the value of the DS decreased with the increment of fiber dosage. The value of the DS also decreased with the enhancement of the matrix strength. An inverse relationship existed between the variation in the IH and DS, whereas the variation in the ER demonstrated a direct proportionality with the variation in the DS. The prediction model for the basalt fiber-reinforced coal gangue ceramsite concrete was obtained by modifying the AFREM model. The values predicted by the improved AFREM model demonstrated excellent consistency with the test data.
- Open Access
- 1 January 2021
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2021 (1)
Influence of Steel Fiber on Durability Performance of Concrete under Freeze‐Thaw Cycles
To verify the steel fiber effect on durability properties of the concrete in cold regions, four types of steel fiber reinforced concrete were prepared, and the fiber dosage were 0, 20 kg, 40 kg, and 60 kg, respectively. The rapid freeze‐thaw test was adopted to evaluate the frost resistance durability, and the evaluation indexes of the mass loss and the residual dynamic modulus of elasticity (RDME) the samples were compared, respectively. The frost damage of the matrix regarding the different freeze‐thaw cycles (FTCs) was evaluated using the Weibull distribution. The capillary water absorption (CWA) experiments were also conducted corresponding to different freeze‐thaw cycles (FTCs). The results revealed that the mass loss was not an effective index for frost damage evaluation of macro‐steel fiber reinforced concrete. The FTCs corresponding to the loss of RDME to 60% were enhanced noticeably with the increase of fiber content. The relationship between the frost damage and the FTCs can be evaluated using the Weibull distribution. Compared with the PC, the frost resistance grade of the reinforced concrete with fiber dosage of 60 kg/m3 increased by 125%. After the frost action, the CWA capacity of concrete improved significantly, while, under the same FTCs, the CWA of the matrix decreased with the increment of macro‐steel fiber dosage. The steel fiber showed a strong positive influence on enhancing the durability performance of concrete in cold region.
- 1 January 2021
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2021 (1)
Open AccessInfluence of Steel Fiber on Durability Performance of Concrete under Freeze‐Thaw Cycles
To verify the steel fiber effect on durability properties of the concrete in cold regions, four types of steel fiber reinforced concrete were prepared, and the fiber dosage were 0, 20 kg, 40 kg, and 60 kg, respectively. The rapid freeze‐thaw test was adopted to evaluate the frost resistance durability, and the evaluation indexes of the mass loss and the residual dynamic modulus of elasticity (RDME) the samples were compared, respectively. The frost damage of the matrix regarding the different freeze‐thaw cycles (FTCs) was evaluated using the Weibull distribution. The capillary water absorption (CWA) experiments were also conducted corresponding to different freeze‐thaw cycles (FTCs). The results revealed that the mass loss was not an effective index for frost damage evaluation of macro‐steel fiber reinforced concrete. The FTCs corresponding to the loss of RDME to 60% were enhanced noticeably with the increase of fiber content. The relationship between the frost damage and the FTCs can be evaluated using the Weibull distribution. Compared with the PC, the frost resistance grade of the reinforced concrete with fiber dosage of 60 kg/m3 increased by 125%. After the frost action, the CWA capacity of concrete improved significantly, while, under the same FTCs, the CWA of the matrix decreased with the increment of macro‐steel fiber dosage. The steel fiber showed a strong positive influence on enhancing the durability performance of concrete in cold region.
- Open Access
- 1 January 2021
- Published by Wiley in Advances in Civil Engineering
- Vol. 2021 (1)
Effect of Capillary Water Absorption on Electrical Resistivity of Concrete with Coal Gangue Ceramsite as Coarse Aggregates
This study intends to access the influence of the capillary action on electrical property of the concrete containing the coal gangue ceramsite. For this purpose, four kinds of concrete samples were prepared; the coal gangue ceramsite was adopted at four volume ratios of 0%, 30%, 60%, and 100%, respectively. The resistivity of the samples was explored using the two‐electrode method during the capillary action. The effects of the coal gangue ceramsite contents on capillary water absorption capacity and resistivity of the matrix were verified. The variation of the resistivity of the matrix under the influence of capillary water transmission was analyzed. The results demonstrated that, for the unsaturated concrete, the resistivity of the matrix increased with the increment of the coal gangue ceramsite dosage. The electrical properties of the concrete were affected noticeably by the capillary water absorption of the matrix; the resistivity of the matrix dropped significantly under the capillary suction, which may be attributed to the formation of the new conductive channels caused by the absorbed water. The variation of the resistivity of the concrete under the capillary suction sustained the two‐stage reduction curve. The ability of the capillary water absorption of concrete was enhanced with the addition of coal gangue ceramsite, compared to the traditional aggregates concrete, the initial sorptivity, and secondary sorptivity of the matrix increased by 47% and 16% with the 100% content of coal gangue ceramsite. However, during the process of the capillary suction, the resistivity of the coal gangue ceramic concrete was always greater than that of the concrete with traditional crushed aggregates.
- 1 January 2021
- Published by Wiley in Advances in Civil Engineering
- Vol. 2021 (1)
Open AccessEffect of Capillary Water Absorption on Electrical Resistivity of Concrete with Coal Gangue Ceramsite as Coarse Aggregates
This study intends to access the influence of the capillary action on electrical property of the concrete containing the coal gangue ceramsite. For this purpose, four kinds of concrete samples were prepared; the coal gangue ceramsite was adopted at four volume ratios of 0%, 30%, 60%, and 100%, respectively. The resistivity of the samples was explored using the two‐electrode method during the capillary action. The effects of the coal gangue ceramsite contents on capillary water absorption capacity and resistivity of the matrix were verified. The variation of the resistivity of the matrix under the influence of capillary water transmission was analyzed. The results demonstrated that, for the unsaturated concrete, the resistivity of the matrix increased with the increment of the coal gangue ceramsite dosage. The electrical properties of the concrete were affected noticeably by the capillary water absorption of the matrix; the resistivity of the matrix dropped significantly under the capillary suction, which may be attributed to the formation of the new conductive channels caused by the absorbed water. The variation of the resistivity of the concrete under the capillary suction sustained the two‐stage reduction curve. The ability of the capillary water absorption of concrete was enhanced with the addition of coal gangue ceramsite, compared to the traditional aggregates concrete, the initial sorptivity, and secondary sorptivity of the matrix increased by 47% and 16% with the 100% content of coal gangue ceramsite. However, during the process of the capillary suction, the resistivity of the coal gangue ceramic concrete was always greater than that of the concrete with traditional crushed aggregates.