QXQixiang Xu

Qixiang Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qixiang Xu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improved KS-GMM algorithm applied in classification and recognition of honey based on laser-induced fluorescence spectra

    by He Chen, Qixiang Xu, Yiwen Jia, Siying Chen, Yinchao Zhang, Pan Guo, Xin Li, Huiyun Wu

    The laser-induced fluorescence (LIF) technique, which has been widely used for food testing, can be combined with various algorithms to classify and recognize different kinds of honey. This paper proposes the Kolmogorov–Smirnov test-Gaussian mixture model (KS-GMM) algorithm, which is coupled with the LIF technique to realize accurate classification and recognition of different types of pure honey. The experiments are designed and carried out to obtain a set of LIF spectrum data from various honey and syrup samples. The proposed KS-GMM algorithm is applied for classification and recognition, with GMM, k-nearest neighbor (kNN), and decision tree algorithms as cross-validation methods. By comparing recognition results of training sets containing different amounts of data, it is found that the KS-GMM algorithm exhibits a maximum recognition accuracy of 96.52%. The research results prove that the KS-GMM algorithm outperforms, to the best of our knowledge, the other three algorithms in classifying and recognizing the honey types.


  • Approximate Voigt function formula for laser-induced breakdown spectroscopy fitting

    by Siying Chen, Yiwen Jia, He Chen, Pan Guo, Qixiang Xu, Lifu Wang, Yinchao Zhang

    Accurate and rapid spectrum fitting is very important for quantitatively analyzing laser-induced breakdown spectroscopy (LIBS). The Voigt function is often used to fit LIBS spectral lines. We propose a new approximate Voigt function formula. Based on the classic Lorentz–Gauss linear combination formula, a summation term was added that contained a specific convolution operation to improve the Voigt function’s calculation and fitting accuracy. This formula can be used for the approximate calculation of the Voigt function with an overall accuracy of 0.31% and a full width at half-maximum internal accuracy of 0.25% when the ratio of Lorentzian linewidth to Gaussian linewidth is 1:1. The formula was then applied to LIBS data processing to fit four element spectral lines of calcium (Ca-393.37, 396.85, and 422.67 nm) and potassium (K-766.49 nm). The fitting results showed that this new approximate formula could fit at least seven data points, and compared with the complex plane partition method and the classic linear combination formula, the new formula had better fitting speed and accuracy.