SNSayedu Khasim Noorbasha

Sayedu Khasim Noorbasha

*This is an algorithmically generated author record based on publicly available information.

Sayedu Khasim Noorbasha has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • VME-EFD : A novel framework to eliminate the Electrooculogram artifact from single-channel EEGs

    by Sayedu Khasim Noorbasha, Arun Kumar

    The diagnosis of neurological disorders often involves analyzing EEG data, which can be contaminated by artifacts from eye movements or blinking (EOG). To improve the accuracy of EEG-based analysis, we propose a novel framework, VME-EFD, which combines Variational Mode Extraction (VME) and Empirical Fourier Decomposition (EFD) for effective EOG artifact removal. In this approach, the EEG signal is first decomposed by VME into two segments: the desired EEG signal and the EOG artifact. The EOG component is further processed by EFD, where decomposition levels are analyzed based on energy and skewness. The level with the highest energy and skewness, corresponding to the artifact, is discarded, while the remaining levels are reintegrated with the desired EEG. Simulations on both synthetic and real EEG datasets demonstrate that VME-EFD outperforms existing methods, with lower RRMSE (0.1358 versus 0.1557, 0.1823, 0.2079, 0.2748), lower ΔPSD in the α band (0.10 ± 0.01 and 0.17 ± 0.04 versus 0.89 ± 0.91 and 0.22 ± 0.19, 1.32 ± 0.23 and 1.10 ± 0.07, 2.86 ± 1.30 and 1.19 ± 0.07, 3.96 ± 0.56 and 2.42 ± 2.48), and higher correlation coefficient (CC: 0.9732 versus 0.9695, 0.9514, 0.8994, 0.8730). The framework effectively removes EOG artifacts and preserves critical EEG features, particularly in the α band, making it highly suitable for brain-computer interface (BCI) applications.


  • Novel approach to remove Electrical Shift and Linear Trend artifact from single channel EEG

    by Sayedu Khasim Noorbasha, Gnanou Florence Sudha

    Electroencephalogram (EEG) signals are crucial to Brain-Computer Interfacing (BCI). However, these are vulnerable to a variety of unintended artifacts that could negatively impact the precise brain function assessment. This paper provides a new algorithm to eliminate Electrical Shift and Linear Trend artifact (ESLT) in EEG using Singular Spectrum Analysis (SSA) and Enhanced local Polynomial (LP) Approximation-based Total Variation (EPATV). The contaminated single channel EEG is subdivided into multiple bands of frequency components by SSA. In order to acquire all LP and TV components, EPATV filtering is applied over the contaminated component frequency band. Filtered sub-signal is collected by subtracting both the LP and TV components from the component contaminated frequency band. Then, the addition of filtered sub-signal and remaining SSA frequency band components yield the final denoised EEG signal. The effectiveness of the proposed method in this paper is evaluated using the data obtained from three databases and compared with the existing methods. From the extensive simulation results, it is inferred that the algorithm discussed in the paper is effective when compared the existing methods, exhibiting a highest averaged Correlation Coefficient (CC) of 0.9534, averaged Signal to Noise Ratio (SNR) of 10.2208dB, lowest averaged Relative Root Mean Square Error (RRMSE) value 0.2787 and averaged Mean absolute Error (MAE) in α band value of 0.0557. The algorithm presented in this paper may be a viable choice for extracting ESLT artifact from a small streaming section of the EEG without requirement of the initial calibration or enormous EEG data.


  • Hybrid algorithm for multi artifact removal from single channel EEG

    by Sayedu Khasim Noorbasha, Gnanou Florence Sudha

    Electroencephalogram (EEG) signals recorded from the ambulatory systems are mostly contaminated by various artifacts like, electrooculogram (EOG), motion artifacts (MA) and electrocardiogram (ECG) artifacts. These artifacts limit the accuracy in further analysis of EEG in practise. So far, several existing methods have been proposed with the combination of decomposition techniques and independent component analysis (ICA) to remove single artifacts and only few methods to remove multiple artifacts from the single channel EEG. As improperly denoised EEG signals can result in wrong diagnosis, in this work, Singular Spectrum Analysis (SSA) and ICA are jointly combined with Generalized Moreau Envelope Total Variation (GMETV) technique to simultaneously remove combinations of different artifacts from single channel EEG. In this work, the SSA is used to decompose the contaminated single channel EEG, while the ICA is employed to separate the various hidden sources as independent components (ICs). Although the ICA is adequate in source separation, there is still, some essential EEG signal data appearing as artifact in the IC. Hence, eliminating this would allow EEG signal information to be lost. The GMETV approach is proposed in this paper, to estimate the actual artifacts in order to address these issues. The estimated actual artifacts are subtracted from the artifact ICs providing the residue of wanted component of EEG. This residue is added back to the remaining ICs, to obtain the denoised EEG. Simulation results demonstrated that the proposed technique performs better compared to the existing techniques. The Relative Root Mean Square Error (RRMSE) is reduced by 12.02% and 7.22% compared to SSA-ICA and SSA-ICA-thresholding respectively. Similarly, the Correlation Coefficient (CC) is increased by 21.48% and 8.25% with respect to SSA-ICA and SSA-ICA-thresholding respectively.