Paul Doumbe-Mandengue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paul Doumbe-Mandengue has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
Jérémie Jacques
Dupuytren University Hospital, France
4 shared publicationsEinas Abou Ali
Endoscopy and Gastroenterology Unit, Cochin University Hospital, Paris, France
3 shared publicationsGabriel Rahmi
Hôpital Européen Georges Pompidou, Île-de-France, France
3 shared publications- Geoffroy Vanbiervliet
Pôle Digestif, Hôpital de L'Archet 2, Nice, France
3 shared publications Jean-Baptiste Chevaux
CHRU de Nancy, Grand Est, France
3 shared publicationsJérôme Rivory
Hopital Edouard Herriot, Hospices Civils de Lyon, France
3 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 05) , E1142-E1143
Endoscopic management of an ileal Dieulafoy's lesion: a rare cause of severe lower gastrointestinal hemorrhage
- 1 October 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 05) , E1142-E1143
Open AccessEndoscopic management of an ileal Dieulafoy's lesion: a rare cause of severe lower gastrointestinal hemorrhage
- Open Access
- 6 August 2026
- Published by Georg Thieme Verlag KG in Endoscopy International Open
Impact of teleconsultation before endoscopic submucosal dissection on quality of care and environmental sustainability: a French multicenter study
Introduction: The European Society of Gastrointestinal Endoscopy has highlighted the environmental impact of endoscopic practice and the need to reduce it. One of the major contributors is patient transportation, despite the availability of remote alternatives for pre-procedural consultations. The aim of this study was to compare face-to-face (FF) and virtual remote (VR) consultations prior to colorectal endoscopic submucosal dissection (ESD) in terms of effectiveness, safety, and carbon footprint. Methods: We used a prospective national database including consecutive colorectal ESD cases performed in France between July 2023 and September 2024. Pre-procedural consultations were conducted either FF or via VR consultation, according to patient preference and logistical feasibility. Procedure-related travel included diagnostic colonoscopy and/or local consultation, anesthesiology consultation (local or remote, excluding same-day combined visits), gastroenterology consultation at the referral center, and travel for the ESD procedure itself. Environmental impact was estimated based on the distance between the patient’s residence and the endoscopy unit, the mode of transportation, and validated conversion coefficients. Results: Between July 2023 and September 2024, 1,729 patients undergoing colorectal ESD were included; 1,451 (84%) underwent face-to-face (FF) and 278 (16%) virtual remote (VR) pre-procedural consultations. Baseline characteristics were comparable. En bloc, R0, and curative resection rates were similar between FF and VR groups (97% vs 95%, p=0.31; 92% vs 88%, p=0.13; 90% vs 90%, p=0.86), as were bleeding and perforation rates. The median cumulative travel distance was significantly lower in the VR group (180.0 km [IQR 261.0] vs 394.6 km [IQR 447.6], p<0.001). Median cumulative carbon footprint decreased from 89.4 to 31.9 CO₂-eq units (p<0.001), corresponding to a total saving of 51,106 CO₂-eq units. Conclusion: Colorectal ESD performed after VR consultation shows comparable effectiveness and safety to FF consultation, while significantly reducing the carbon footprint.
- 6 August 2026
- Published by Georg Thieme Verlag KG in Endoscopy International Open
Open AccessImpact of teleconsultation before endoscopic submucosal dissection on quality of care and environmental sustainability: a French multicenter study
Introduction: The European Society of Gastrointestinal Endoscopy has highlighted the environmental impact of endoscopic practice and the need to reduce it. One of the major contributors is patient transportation, despite the availability of remote alternatives for pre-procedural consultations. The aim of this study was to compare face-to-face (FF) and virtual remote (VR) consultations prior to colorectal endoscopic submucosal dissection (ESD) in terms of effectiveness, safety, and carbon footprint. Methods: We used a prospective national database including consecutive colorectal ESD cases performed in France between July 2023 and September 2024. Pre-procedural consultations were conducted either FF or via VR consultation, according to patient preference and logistical feasibility. Procedure-related travel included diagnostic colonoscopy and/or local consultation, anesthesiology consultation (local or remote, excluding same-day combined visits), gastroenterology consultation at the referral center, and travel for the ESD procedure itself. Environmental impact was estimated based on the distance between the patient’s residence and the endoscopy unit, the mode of transportation, and validated conversion coefficients. Results: Between July 2023 and September 2024, 1,729 patients undergoing colorectal ESD were included; 1,451 (84%) underwent face-to-face (FF) and 278 (16%) virtual remote (VR) pre-procedural consultations. Baseline characteristics were comparable. En bloc, R0, and curative resection rates were similar between FF and VR groups (97% vs 95%, p=0.31; 92% vs 88%, p=0.13; 90% vs 90%, p=0.86), as were bleeding and perforation rates. The median cumulative travel distance was significantly lower in the VR group (180.0 km [IQR 261.0] vs 394.6 km [IQR 447.6], p<0.001). Median cumulative carbon footprint decreased from 89.4 to 31.9 CO₂-eq units (p<0.001), corresponding to a total saving of 51,106 CO₂-eq units. Conclusion: Colorectal ESD performed after VR consultation shows comparable effectiveness and safety to FF consultation, while significantly reducing the carbon footprint.
- Open Access
- 13 February 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (07) , 699-708
Outcomes after radical endoscopic resection of high risk T1 esophageal adenocarcinoma: an international multicenter retrospective cohort study
Post-endoscopic resection (ER) management of high risk T1 esophageal adenocarcinoma (EAC) is debated, with conflicting reports on lymph node metastasis (LNM). We aimed to assess outcomes following radical ER for high risk T1 EAC.We identified patients who underwent radical ER (tumor-negative deep margin) of high risk T1 EAC, followed by surgery or endoscopic surveillance, between 2008 and 2019 across 11 international centers.106 patients (86 men; mean [SD] age, 70 [11] years) were included. Of these, 26 (age, 64 [11] years) underwent additional surgery, with residual T1 EAC found in five patients (19%) and LNM in two (8%). After a median [IQR] follow-up of 47 [32–79] months, 2/26 patients (8%) developed LNM/distant metastasis, with one EAC-related death (4%), one unrelated death (4%), and four patients lost to follow-up (15%). Of the 80 patients (age, 71 [9] years) who entered endoscopic surveillance, 5/80 (6%) developed LNM/distant metastasis, with four EAC-related deaths (5%) over 46 (IQR 25–59) months follow-up; there were 15 unrelated deaths (19%), and 10 patients lost to follow-up (13%). The overall rates (95%CI) were: LNM, 6% (2%–12%); LNM/distant metastasis, 7% (3%–13%); EAC-related mortality, 5% (2%–11%); overall mortality, 20% (95%CI 13–29).Our findings present low rates of LNM after radical ER of high risk T1 EAC, consistent with other endoscopy-focused studies. Post-surgical patients are still at risk for metastasis and disease-specific mortality. These results suggest that endoscopic surveillance is suitable for selected cases, but further prospective studies are needed to refine patient selection and confirm optimal outcomes.
- 13 February 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (07) , 699-708
Open AccessOutcomes after radical endoscopic resection of high risk T1 esophageal adenocarcinoma: an international multicenter retrospective cohort study
Post-endoscopic resection (ER) management of high risk T1 esophageal adenocarcinoma (EAC) is debated, with conflicting reports on lymph node metastasis (LNM). We aimed to assess outcomes following radical ER for high risk T1 EAC.We identified patients who underwent radical ER (tumor-negative deep margin) of high risk T1 EAC, followed by surgery or endoscopic surveillance, between 2008 and 2019 across 11 international centers.106 patients (86 men; mean [SD] age, 70 [11] years) were included. Of these, 26 (age, 64 [11] years) underwent additional surgery, with residual T1 EAC found in five patients (19%) and LNM in two (8%). After a median [IQR] follow-up of 47 [32–79] months, 2/26 patients (8%) developed LNM/distant metastasis, with one EAC-related death (4%), one unrelated death (4%), and four patients lost to follow-up (15%). Of the 80 patients (age, 71 [9] years) who entered endoscopic surveillance, 5/80 (6%) developed LNM/distant metastasis, with four EAC-related deaths (5%) over 46 (IQR 25–59) months follow-up; there were 15 unrelated deaths (19%), and 10 patients lost to follow-up (13%). The overall rates (95%CI) were: LNM, 6% (2%–12%); LNM/distant metastasis, 7% (3%–13%); EAC-related mortality, 5% (2%–11%); overall mortality, 20% (95%CI 13–29).Our findings present low rates of LNM after radical ER of high risk T1 EAC, consistent with other endoscopy-focused studies. Post-surgical patients are still at risk for metastasis and disease-specific mortality. These results suggest that endoscopic surveillance is suitable for selected cases, but further prospective studies are needed to refine patient selection and confirm optimal outcomes.
- 27 July 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (11) , 1002-1009
Use of endoscopic submucosal dissection or full-thickness resection device to treat residual colorectal neoplasia after endoscopic resection: a multicenter historical cohort study
Introduction Residual colorectal neoplasia (RCN) after previous endoscopic mucosal resection is a frequent challenge. Different management techniques are feasible including endoscopic full-thickness resection using the full-thickness resection device (FTRD) system and endoscopic submucosal dissection (ESD). We aimed to compare the efficacy and safety of these two techniques for the treatment of such lesions. Methods All consecutive patients with RCN treated either using the FTRD or by ESD were retrospectively included in this multicenter study. The primary outcome was the R0 resection rate, defined as an en bloc resection with histologically tumor-free lateral and deep margins. Results 275 patients (median age 70 years; 160 men) who underwent 177 ESD and 98 FTRD procedures for RCN were included. R0 resection was achieved in 83.3 % and 77.6 % for ESD and FTRD, respectively (P = 0.25). Lesions treated by ESD were however larger than those treated by FTRD (P < 0.001). The R0 rates for lesions of 20–30 mm were 83.9 % and 57.1 % in the ESD and FTRD groups, respectively, and for lesions of 30–40 mm were 93.6 % and 33.3 %, respectively. On multivariable analysis, ESD procedures were associated with statistically higher en bloc and R0 resection rates after adjustment for lesion size (P = 0.02 and P < 0.001, respectively). The adverse event rate was higher in the ESD group (16.3 % vs. 5.1 %), mostly owing to intraoperative perforations. Conclusion ESD is effective in achieving R0 resection for RCN whatever the size and location of the lesions. When residual lesions are smaller than 20 mm, the FTRD is an effective alternative.
- 27 July 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (11) , 1002-1009
Use of endoscopic submucosal dissection or full-thickness resection device to treat residual colorectal neoplasia after endoscopic resection: a multicenter historical cohort study
Introduction Residual colorectal neoplasia (RCN) after previous endoscopic mucosal resection is a frequent challenge. Different management techniques are feasible including endoscopic full-thickness resection using the full-thickness resection device (FTRD) system and endoscopic submucosal dissection (ESD). We aimed to compare the efficacy and safety of these two techniques for the treatment of such lesions. Methods All consecutive patients with RCN treated either using the FTRD or by ESD were retrospectively included in this multicenter study. The primary outcome was the R0 resection rate, defined as an en bloc resection with histologically tumor-free lateral and deep margins. Results 275 patients (median age 70 years; 160 men) who underwent 177 ESD and 98 FTRD procedures for RCN were included. R0 resection was achieved in 83.3 % and 77.6 % for ESD and FTRD, respectively (P = 0.25). Lesions treated by ESD were however larger than those treated by FTRD (P < 0.001). The R0 rates for lesions of 20–30 mm were 83.9 % and 57.1 % in the ESD and FTRD groups, respectively, and for lesions of 30–40 mm were 93.6 % and 33.3 %, respectively. On multivariable analysis, ESD procedures were associated with statistically higher en bloc and R0 resection rates after adjustment for lesion size (P = 0.02 and P < 0.001, respectively). The adverse event rate was higher in the ESD group (16.3 % vs. 5.1 %), mostly owing to intraoperative perforations. Conclusion ESD is effective in achieving R0 resection for RCN whatever the size and location of the lesions. When residual lesions are smaller than 20 mm, the FTRD is an effective alternative.
- 9 May 2023
- Published by Elsevier in Clinics and Research in Hepatology and Gastroenterology
- Vol. 47 (6) , 102138
Endoscopic submucosal dissection versus endoscopic mucosal resection for early esophageal adenocarcinoma
- 9 May 2023
- Published by Elsevier in Clinics and Research in Hepatology and Gastroenterology
- Vol. 47 (6) , 102138
Endoscopic submucosal dissection versus endoscopic mucosal resection for early esophageal adenocarcinoma
- Open Access
- 24 June 2022
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (S 02) , E869-E870
Underwater endoscopic mucosal resection for a protruding lesion in the esophagus
A 70-year-old man with a history of ischemic cardiopathy, taking clopidogrel as his usual treatment, was referred because of cholangitis. Computed tomography and magnetic resonance imaging scans revealed a dilated bile duct without any obvious obstruction. Gastroscopy and endoscopic ultrasound were performed in search of an ampulloma, and unexpectedly identified a sessile tumor 2 cm above the gastroesophageal junction ([Fig. 1]). Gastroscopy performed with a high definition endoscope and magnification (EG-760Z; Fujifilm, Tokyo, Japan) confirmed a 0-Ip esophageal lesion with a suspicious irregular mucosal and vascular pattern ([Fig. 2]). In the absence of endoscopic features suggesting deep submucosal invasion, endoscopic resection was chosen. Owing to the sessile shape of the lesion, an underwater endoscopic mucosal resection (UEMR) was performed. We used a water pump to fill the entire esophageal lumen with saline ([Video 1]). A 15-mm diathermic snare was deployed to encircle the tumor, and was then closed on the polyp ([Fig. 3]). Safe margins were confirmed endoscopically before resecting the lesion using an Endocut current. After the resection, minor bleeding was successfully treated with the tip of the snare in soft coagulation mode, and the wound was closed with standard clips. Video 1 Underwater endoscopic mucosal resection for a sessile esophageal lesion. The resected specimen was 1.5 × 0.8 × 0.6 cm in size. Histological examination revealed a well-differentiated intramucosal adenocarcinoma, with margins free of dysplasia and cancer. Previous studies have reported colorectal [1] [2] [3] and gastric [4] UEMR as an alternative to classic EMR. To the best of our knowledge, this is the first UEMR reported for an esophageal lesion. UEMR can be used for small sessile or pedunculated lesions in the esophagus, and is safe, fast, and efficient. Endoscopy_UCTN_Code_TTT_1AO_2AC Article published online: 24 June 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 24 June 2022
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (S 02) , E869-E870
Open AccessUnderwater endoscopic mucosal resection for a protruding lesion in the esophagus
A 70-year-old man with a history of ischemic cardiopathy, taking clopidogrel as his usual treatment, was referred because of cholangitis. Computed tomography and magnetic resonance imaging scans revealed a dilated bile duct without any obvious obstruction. Gastroscopy and endoscopic ultrasound were performed in search of an ampulloma, and unexpectedly identified a sessile tumor 2 cm above the gastroesophageal junction ([Fig. 1]). Gastroscopy performed with a high definition endoscope and magnification (EG-760Z; Fujifilm, Tokyo, Japan) confirmed a 0-Ip esophageal lesion with a suspicious irregular mucosal and vascular pattern ([Fig. 2]). In the absence of endoscopic features suggesting deep submucosal invasion, endoscopic resection was chosen. Owing to the sessile shape of the lesion, an underwater endoscopic mucosal resection (UEMR) was performed. We used a water pump to fill the entire esophageal lumen with saline ([Video 1]). A 15-mm diathermic snare was deployed to encircle the tumor, and was then closed on the polyp ([Fig. 3]). Safe margins were confirmed endoscopically before resecting the lesion using an Endocut current. After the resection, minor bleeding was successfully treated with the tip of the snare in soft coagulation mode, and the wound was closed with standard clips. Video 1 Underwater endoscopic mucosal resection for a sessile esophageal lesion. The resected specimen was 1.5 × 0.8 × 0.6 cm in size. Histological examination revealed a well-differentiated intramucosal adenocarcinoma, with margins free of dysplasia and cancer. Previous studies have reported colorectal [1] [2] [3] and gastric [4] UEMR as an alternative to classic EMR. To the best of our knowledge, this is the first UEMR reported for an esophageal lesion. UEMR can be used for small sessile or pedunculated lesions in the esophagus, and is safe, fast, and efficient. Endoscopy_UCTN_Code_TTT_1AO_2AC Article published online: 24 June 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 7 January 2022
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 117 (4) , 533
Duodenal Lymphangiectasia
An abstract is unavailable. This article is available as a PDF only.
- 7 January 2022
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 117 (4) , 533
Duodenal Lymphangiectasia
An abstract is unavailable. This article is available as a PDF only.
- 1 May 2021
- Published by Elsevier in Clinics and Research in Hepatology and Gastroenterology
- Vol. 45 (3) , 101700
Outcomes of endoscopic submucosal dissection for early esophageal and gastric cardia adenocarcinomas
- 1 May 2021
- Published by Elsevier in Clinics and Research in Hepatology and Gastroenterology
- Vol. 45 (3) , 101700
Outcomes of endoscopic submucosal dissection for early esophageal and gastric cardia adenocarcinomas