Kathryn Anne Jimenez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kathryn Anne Jimenez has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Byung Ho Lee
Department of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
2 shared publications - Hak-Sun Kim
Department of Orthopedic Surgery, Yonsei University College of Medicine, Seoul, Republic of Korea
2 shared publications - Hwan-Mo Lee
Department of Orthopaedic Surgery, Yonsei University College of Medicine, Seoul, Korea
2 shared publications - Kyung-Soo Suk
Department of Orthopedic Surgery, Yonsei University College of Medicine, Seoul, Korea
2 shared publications - Seong-Hwan Moon
Department of Orthopedic Surgery, Yonsei University College of Medicine, Seoul, Korea
2 shared publications - Ja-Yeong Yoon
Department of Orthopedic Surgery, Chungnam National University Sejong Hospital, Sejong 30099, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 10 May 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (9) , 2034
Short Plate with Screw Angle over 20 Degrees Improves the Radiologic Outcome in ACDF: Clinical Study
Background: Anterior cervical discectomy and fusion surgery is a common procedure for degenerative cervical spine. This describes allospacer and implant-related outcomes, comparing medium plate–low screw angle and short plate–high screw angle techniques. Methods: From January 2016 to June 2019, 79 patients who underwent ACDF were prospectively enrolled. Patients were divided, depending on the plate–screw system used: medium plate–low screw angle (12.3 ± 2.5 to 13.2 ± 3.2 degrees), and short plate–high screw angle (22.8 ± 5.3 to 23.3 ± 4.7 degrees). Subsidence, ALOD, and sagittal cervical balance were analyzed using lateral cervical X-rays. NDI and VAS scores were also evaluated. Results: Age for medium plate–low-angled screw group is 58.0 ± 11.3 years, and 55.3 ± 12.0 in the short plate–high-angled screw group (p-value = 0.313). Groups were comparable in mean NDI (p-value = 0.347), VAS (p-value = 0.156), C2–C7 SVA, (p-value = 0.981), and lordosis angle (p-value = 0.836) at 1-year post-surgery. Subsidence was higher in the medium plate–low-angled screw than in the short plate–high-angled screw (25% and 8.5%, respectively, p-value = 0.045). ALOD is also more common in the medium plate group (p-value = 0.045). Conclusion: Use of a short plate and insertion of high-angled screws (more than 20 degrees) has less chance of subsidence and occurrence of ALOD than the traditional technique of using medium plate and low angle.
- 10 May 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (9) , 2034
Open AccessShort Plate with Screw Angle over 20 Degrees Improves the Radiologic Outcome in ACDF: Clinical Study
Background: Anterior cervical discectomy and fusion surgery is a common procedure for degenerative cervical spine. This describes allospacer and implant-related outcomes, comparing medium plate–low screw angle and short plate–high screw angle techniques. Methods: From January 2016 to June 2019, 79 patients who underwent ACDF were prospectively enrolled. Patients were divided, depending on the plate–screw system used: medium plate–low screw angle (12.3 ± 2.5 to 13.2 ± 3.2 degrees), and short plate–high screw angle (22.8 ± 5.3 to 23.3 ± 4.7 degrees). Subsidence, ALOD, and sagittal cervical balance were analyzed using lateral cervical X-rays. NDI and VAS scores were also evaluated. Results: Age for medium plate–low-angled screw group is 58.0 ± 11.3 years, and 55.3 ± 12.0 in the short plate–high-angled screw group (p-value = 0.313). Groups were comparable in mean NDI (p-value = 0.347), VAS (p-value = 0.156), C2–C7 SVA, (p-value = 0.981), and lordosis angle (p-value = 0.836) at 1-year post-surgery. Subsidence was higher in the medium plate–low-angled screw than in the short plate–high-angled screw (25% and 8.5%, respectively, p-value = 0.045). ALOD is also more common in the medium plate group (p-value = 0.045). Conclusion: Use of a short plate and insertion of high-angled screws (more than 20 degrees) has less chance of subsidence and occurrence of ALOD than the traditional technique of using medium plate and low angle.
- Open Access
- 5 May 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (9) , 1980
Handgrip Strength Correlated with Falling Risk in Patients with Degenerative Cervical Myelopathy
Background: Few studies have investigated associations between hand grip strength (HGS) and the surgical outcomes of degenerative cervical myelopathy (DCM). Methods: This study was designed as a prospective observational study of 203 patients who had undergone fusion surgery for DCM. We divided the patients according to sex and HGS differences. Clinical outcome parameters, including HGS, a fall diary and four functional mobility tests (alternative step test, six-meter walk test, timed up and go test, and sit-to-stand test) were measured preoperatively, at 3 months and 1 year after surgery. Results: Mean patient ages were 59.93 years in the male group and 67.33 years in the female group (p = 0.000; independent t-test). The mean HGS of both hands improved significantly at postoperative 3 months and 1 year in all patients (p = 0.000 for both; ANOVA). In male patients, preoperative risk of falls was negatively correlated with HGS (p = 0.000). In female patients, pre- and postoperative risk of falls were correlated negatively with HGS (p = 0.000). The postoperative incidence of falls decreased in both groups (p = 0.000) Conclusions: Postoperative HGS in patients with DCM is correlated with postoperative falls and functional outcome differently, when comparing male and female patients, for predicting favorable outcomes and neurologic deficit recovery after surgery in DCM patients.
- 5 May 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (9) , 1980
Open AccessHandgrip Strength Correlated with Falling Risk in Patients with Degenerative Cervical Myelopathy
Background: Few studies have investigated associations between hand grip strength (HGS) and the surgical outcomes of degenerative cervical myelopathy (DCM). Methods: This study was designed as a prospective observational study of 203 patients who had undergone fusion surgery for DCM. We divided the patients according to sex and HGS differences. Clinical outcome parameters, including HGS, a fall diary and four functional mobility tests (alternative step test, six-meter walk test, timed up and go test, and sit-to-stand test) were measured preoperatively, at 3 months and 1 year after surgery. Results: Mean patient ages were 59.93 years in the male group and 67.33 years in the female group (p = 0.000; independent t-test). The mean HGS of both hands improved significantly at postoperative 3 months and 1 year in all patients (p = 0.000 for both; ANOVA). In male patients, preoperative risk of falls was negatively correlated with HGS (p = 0.000). In female patients, pre- and postoperative risk of falls were correlated negatively with HGS (p = 0.000). The postoperative incidence of falls decreased in both groups (p = 0.000) Conclusions: Postoperative HGS in patients with DCM is correlated with postoperative falls and functional outcome differently, when comparing male and female patients, for predicting favorable outcomes and neurologic deficit recovery after surgery in DCM patients.