Peter Bruyndonckx
Research Subjects
Peter Bruyndonckx has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Gonzalez-Montoro
Instituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC–Universitat Politècnica de València
3 shared publications - Antonio Javier Gonzalez
Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC—Universitat Politècnica de València, Camino de Vera s/n, 46022 Valencia, Spain
3 shared publications - Alexander Sasov
Dniprovsk State Technical University Dniprobudivska str., 2, Kamianske, Ukraine, 51918
2 shared publications B. Pauwels
Skyscan, Kartuizersweg 3B, 2550 Kontich, Belgium
2 shared publications- Marta Freire
Instituto de Instrumentación Para Imagen Molecular (I3M), Centro Mixto CSIC-Universitat Politècnica de València, Valencia, Spain
2 shared publications - Neus Cucarella
Instituto de Instrumentacin para Imagen Molecular, Centro Mixto CSICUniversitat Politcnica de Valncia, Valencia, Spain
2 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (7) , 1143-1151
Development of a Preclinical PET Scanner With DOI Capabilities Using Semi-Monolithic Detectors
Most preclinical PET scanners are based on pixelated detectors without Depth of Interaction (DOI) capabilities, which is crucial to correct for parallax errors. Semi-monolithic crystals have the potential to combine the timing capabilities of pixelated crystals and the 3D positioning accuracy of monolithic scintillators. In this work, we present a preclinical PET prototype consisting of 2 rings defining an inner diameter of 106 mm and an axial length of 52 mm. Each ring contains 14 arrays of 1 × 22 LYSO slabs of 0.97 mm × 25.6 mm × 12 mm, coupled to 8 × 8 SiPMs arrays. The sensitivity, spatial resolution, count rate performance and image quality were studied using the NEMA NU 4-2008 protocol. All images were reconstructed using the MLEM algorithm with 0.5 mm voxel size, including DOI information and normalization correction. A mean spatial resolution for all measured positions and across the three directions (axial, transaxial and radial) of 1.61 ± 0.19 mm was obtained at the center of the FOV. A peak sensitivity of 3.5% was obtained at the center of the scanner, for an energy window (EW) between 358 keV -664 keV. The noise equivalent count rate peak reached 106.9 kcps for an activity of 11.7 MBq using the mouse-sized phantom, the same EW window and a time coincidence window of 10 ns. For the image quality phantom, contrast recovery coefficients of 0.20, 0.62, 0.75, 0.81 and 0.85 were found for the 1, 2, 3, 4 and 5 mm rods, respectively. Spill-over-ratio values of 0.10 for air-filled and 0.23 for water-filled cylinders were measured. Also, according to the Rayleigh criterion, 1.5, 1.2 and 1 mm hot spots of a micro-Derenzo phantom were well distinguished.
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (7) , 1143-1151
Open AccessDevelopment of a Preclinical PET Scanner With DOI Capabilities Using Semi-Monolithic Detectors
Most preclinical PET scanners are based on pixelated detectors without Depth of Interaction (DOI) capabilities, which is crucial to correct for parallax errors. Semi-monolithic crystals have the potential to combine the timing capabilities of pixelated crystals and the 3D positioning accuracy of monolithic scintillators. In this work, we present a preclinical PET prototype consisting of 2 rings defining an inner diameter of 106 mm and an axial length of 52 mm. Each ring contains 14 arrays of 1 × 22 LYSO slabs of 0.97 mm × 25.6 mm × 12 mm, coupled to 8 × 8 SiPMs arrays. The sensitivity, spatial resolution, count rate performance and image quality were studied using the NEMA NU 4-2008 protocol. All images were reconstructed using the MLEM algorithm with 0.5 mm voxel size, including DOI information and normalization correction. A mean spatial resolution for all measured positions and across the three directions (axial, transaxial and radial) of 1.61 ± 0.19 mm was obtained at the center of the FOV. A peak sensitivity of 3.5% was obtained at the center of the scanner, for an energy window (EW) between 358 keV -664 keV. The noise equivalent count rate peak reached 106.9 kcps for an activity of 11.7 MBq using the mouse-sized phantom, the same EW window and a time coincidence window of 10 ns. For the image quality phantom, contrast recovery coefficients of 0.20, 0.62, 0.75, 0.81 and 0.85 were found for the 1, 2, 3, 4 and 5 mm rods, respectively. Spill-over-ratio values of 0.10 for air-filled and 0.23 for water-filled cylinders were measured. Also, according to the Rayleigh criterion, 1.5, 1.2 and 1 mm hot spots of a micro-Derenzo phantom were well distinguished.
- 12 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (3) , 282-305
Evolution of PET Detectors and Event Positioning Algorithms Using Monolithic Scintillation Crystals
The use of monolithic scintillator-based photon detectors in positron emission tomography (PET) has emerged as an attractive alternative to traditional pixelated array designs. Monolithic-based detector designs employ the scintillation light distribution (LD) shape to provide a single 3D photon interaction position per event, enabling high spatial resolution throughout the crystal volume. Since there are no intercrystal gaps, monolithic designs provide higher intrinsic detection efficiency compared to pixelated designs. However, in order to make the monolithic detector design practical for clinical PET systems, some major drawbacks need to be addressed such as the timeconsuming and complex calibration procedures to obtain precise spatial and timing information. This paper gives a historical review of monolithic-based PET detectors, a description of their main advantages and challenges, describes the state-of-the-art, including their use in current commercial system, and ends with a future prospective.
- 12 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 5 (3) , 282-305
Evolution of PET Detectors and Event Positioning Algorithms Using Monolithic Scintillation Crystals
The use of monolithic scintillator-based photon detectors in positron emission tomography (PET) has emerged as an attractive alternative to traditional pixelated array designs. Monolithic-based detector designs employ the scintillation light distribution (LD) shape to provide a single 3D photon interaction position per event, enabling high spatial resolution throughout the crystal volume. Since there are no intercrystal gaps, monolithic designs provide higher intrinsic detection efficiency compared to pixelated designs. However, in order to make the monolithic detector design practical for clinical PET systems, some major drawbacks need to be addressed such as the timeconsuming and complex calibration procedures to obtain precise spatial and timing information. This paper gives a historical review of monolithic-based PET detectors, a description of their main advantages and challenges, describes the state-of-the-art, including their use in current commercial system, and ends with a future prospective.
- 1 June 2010
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 25 (2) , 157-160
Towards sub-100-nm X-ray microscopy for tomographic applications
We have demonstrated that structures down to 150 nm can be visualized in X-ray projection images using nanofocus X-ray sources. Due to their unlimited depth of focus, they do not possess a limit on the specimen size. This is essential for three-dimensional tomographic imaging of samples with a diameter larger than a few microns. Further simulation studies have shown that optimization of the detector response curve and switching from a reflective X-ray target to a transmission target should allow us to reach sub-100-nm resolutions.
- 1 June 2010
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 25 (2) , 157-160
Towards sub-100-nm X-ray microscopy for tomographic applications
We have demonstrated that structures down to 150 nm can be visualized in X-ray projection images using nanofocus X-ray sources. Due to their unlimited depth of focus, they do not possess a limit on the specimen size. This is essential for three-dimensional tomographic imaging of samples with a diameter larger than a few microns. Further simulation studies have shown that optimization of the detector response curve and switching from a reflective X-ray target to a transmission target should allow us to reach sub-100-nm resolutions.
- 1 June 2009
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 24 (2) , 166
D-44 Towards Sub-100 nm X-ray Microscopy for Tomographic Applications
- 1 June 2009
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 24 (2) , 166
D-44 Towards Sub-100 nm X-ray Microscopy for Tomographic Applications
- 16 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 53 (5) , 2543-2548
Initial Characterization of a Nonpixelated Scintillator Detector in a PET Prototype Demonstrator
Previous experimental results have demonstrated that a PET detector module based on a 20times10times10 mm LSO block read out by a Hamamatsu S8550 APD array is able to determine the impinging position of perpendicularly incident 511-keV photons with a resolution better than 2-mm FWHM. A prototype PET demonstrator using two of these detector heads was build and evaluated. The axial and transaxial resolution measured in two-dimensional (2-D) OSEM and 2-D FBP reconstructed images is better than 1.5- and 2-mm FWHM, respectively, for radial distances less than 15 mm. A Monte Carlo simulation showed that a four-ring PET scanner based on these monolithic scintillator blocks has a sensitivity which is about 2.5 times higher than the sensitivity of a similar system equipped with detector heads using a 4times8 matrix of 2times2times10 mm LSO pixels
- 16 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 53 (5) , 2543-2548
Initial Characterization of a Nonpixelated Scintillator Detector in a PET Prototype Demonstrator
Previous experimental results have demonstrated that a PET detector module based on a 20times10times10 mm LSO block read out by a Hamamatsu S8550 APD array is able to determine the impinging position of perpendicularly incident 511-keV photons with a resolution better than 2-mm FWHM. A prototype PET demonstrator using two of these detector heads was build and evaluated. The axial and transaxial resolution measured in two-dimensional (2-D) OSEM and 2-D FBP reconstructed images is better than 1.5- and 2-mm FWHM, respectively, for radial distances less than 15 mm. A Monte Carlo simulation showed that a four-ring PET scanner based on these monolithic scintillator blocks has a sensitivity which is about 2.5 times higher than the sensitivity of a similar system equipped with detector heads using a 4times8 matrix of 2times2times10 mm LSO pixels