WJWeiwei Jiang

Weiwei Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Weiwei Jiang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Xiaobo Lai

    School of Medical Technology and Information Engineering, Zhejiang Chinese Medical University, Hangzhou, China

    3 shared publications
  • Xiaomei Xu

    School of Medical Technology and Information Engineering, Zhejiang Chinese Medical University, Hangzhou, China

    3 shared publications
  • He Huang

    Academy of Medical Engineering and Translational Medicine, State Key Laboratory of Advanced Medical Materials and Devices, Haihe Laboratory of Brain-computer Interaction and Human-machine Integration, Tianjin Key Laboratory of Brain Science and Neural Engineering, Tianjin University, Tianjin, China

    2 shared publications
  • Bo Lu

    Shanghai Normal University Tianhua College

    1 shared publication
  • Chun Xie

    State Key Laboratory of Quality Research in Chinese Medicine, Macau Institute for Applied Research in Medicine and Health, Macau University of Science and Technology, Macau 853, (S.A.R.), China

    1 shared publication
  • Jianming Ye

    Department of Oncology, The First Affiliated Hospital of Gannan Medical University, China

    1 shared publication

Latest Publications

  • Retracted
    Open Access

    Retinal Vessel Automatic Segmentation Using SegNet

    by Xiaomei Xu, Yixin Wang, Yu Liang, Siyuan Luo, Jianqing Wang, Weiwei Jiang, Xiaobo Lai

    Extracting retinal vessels accurately is very important for diagnosing some diseases such as diabetes retinopathy, hypertension, and cardiovascular. Clinically, experienced ophthalmologists diagnose these diseases through segmenting retinal vessels manually and analysing its structural feature, such as tortuosity and diameter. However, manual segmentation of retinal vessels is a time-consuming and laborious task with strong subjectivity. The automatic segmentation technology of retinal vessels can not only reduce the burden of ophthalmologists but also effectively solve the problem that is a lack of experienced ophthalmologists in remote areas. Therefore, the automatic segmentation technology of retinal vessels is of great significance for clinical auxiliary diagnosis and treatment of ophthalmic diseases. A method using SegNet is proposed in this paper to improve the accuracy of the retinal vessel segmentation. The performance of the retinal vessel segmentation model with SegNet is evaluated on the three public datasets (DRIVE, STARE, and HRF) and achieved accuracy of 0.9518, 0.9683, and 0.9653, sensitivity of 0.7580, 0.7747, and 0.7070, specificity of 0.9804, 0.9910, and 0.9885, score of 0.7992, 0.8369, and 0.7918, MCC of 0.7749, 0.8227, and 0.7643, and AUC of 0.9750, 0.9893, and 0.9740, respectively. The experimental results showed that the method proposed in this research presented better results than many classical methods studied and may be expected to have clinical application prospects.


  • Nonlocal convolutional block attention module VNet for gliomas automatic segmentation

    by Ying Fang, He Huang, Weiji Yang, Xiaomei Xu, Weiwei Jiang, Xiaobo Lai

    Glioma is the most common primary tumor in the skull, but it has no obvious boundary with normal brain tissue and is difficult to completely remove. Currently, manual segmentation of the lesion regions has been widely used in the clinical practice of magnetic resonance (MR) images of gliomas, but the implementation process has disadvantages such as time‐consuming and poor repeatability. It is because of the shortcomings of traditional segmentation methods that we must seek other efficient technical means, which promote the development of automatic image segmentation technology. In this study, we propose a glioma automatic segmentation method called NLCA‐VNet. The framework is based on VNet, adding nonlocal and convolutional block attention modules, which can maintain more information, and can carry out attention in the channel and spatial dimensions, so that improve the segmentation effect. We employ the extended glioma MR image data set by the Brain Tumor Segmentation Challenge database (BraTS 2020, 2019, 2018), and finally obtained the effect image after tumor segmentation and achieved average Dice scores of 0.6702, 0.876, 0.7687, sensitivity of 0.7494, 0.9209, 0.7702, specificity of 0.0.9994, 0.9985, 0.9995, and Hausdorff95 of 50.8613, 9.3667, 12.4573 for enhancing tumor core, whole tumor, and tumor core in BraTS 2020, respectively. The results fully show that our method can fully adapt to the segmentation of glioma. To a certain extent, it improves the efficiency and accuracy of the doctor's diagnosis, which is of great significance to the scientific research and clinical aspects of glioma.


  • Open Access

    Tumor Grade and Overall Survival Prediction of Gliomas Using Radiomics

    by Jianming Ye, He Huang, Weiwei Jiang, Xiaomei Xu, Chun Xie, Bo Lu, Xiangcai Wang, Xiaobo Lai

    Glioma is one of the most common and deadly malignant brain tumors originating from glial cells. For personalized treatment, an accurate preoperative prognosis for glioma patients is highly desired. Recently, various machine learning-based approaches have been developed to predict the prognosis based on preoperative magnetic resonance imaging (MRI) radiomics, which extract quantitative features from radiographic images. However, major challenges remain for methodologic developments to optimize feature extraction and provide rapid information flow in clinical settings. This study investigates two machine learning-based prognosis prediction tasks using radiomic features extracted from preoperative multimodal MRI brain data: (i) prediction of tumor grade (higher-grade vs. lower-grade gliomas) from preoperative MRI scans and (ii) prediction of patient overall survival (OS) in higher-grade gliomas ( 12 months) from preoperative MRI scans. Specifically, these two tasks utilize the conventional machine learning-based models built with various classifiers. Moreover, feature selection methods are applied to increase model performance and decrease computational costs. In the experiments, models are evaluated in terms of their predictive performance and stability using a bootstrap approach. Experimental results show that classifier choice and feature selection technique plays a significant role in model performance and stability for both tasks; a variability analysis indicates that classification method choice is the most dominant source of performance variation for both tasks.