WLWenjie Li

Wenjie Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wenjie Li has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Yinping Miao

    School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin, China

    4 shared publications
  • Kailiang Zhang

    Tianjin Key Laboratory of Film Electronic and Communication Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin 300384, China

    3 shared publications
  • Mingpan Bi

    School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin, China

    2 shared publications
  • Aijun Wen

    Collaborative Innovation Center of Information Sensing and Understanding at Xidian University

    1 shared publication
  • Bin Li

    Tianjin Key Laboratory of Film Electronic and Communicate Devices, School of Electrical and Electronic Engineering, Tianjin University of Technology, Tianjin 300384, China

    1 shared publication
  • Cheng-Wei Fei

    College of Intelligent Robotics and Advanced Manufacturing, Fudan University, Shanghai 200433, China

    1 shared publication

Latest Publications

  • Nb2CTx MXene Integrated Tapered Microfiber Based on Light-Controlled Light for Ultra-Sensitive and Wide-Range Hemoglobin Detection

    by Wenjie Li, Yinping Miao, Yibo Zheng, Kailiang Zhang, Jianquan Yao

    Hemoglobin is an indicator of various diseases in humans, and shows excellent photothermal properties. Here, a biosensor combining the molecular photothermal effect with the Nb 2 CT x MXene integrated microfiber is proposed for the specific detection of human hemoglobin concentration by light-controlled light technique. The Nb 2 CT x MXene with a large specific surface and hydrophilicity is deposited on the surface of the microfiber through an optical deposition method, which makes hemoglobin molecules adsorbed on the surface of the microfiber and enhance the interaction between light and matter. Under the irradiation of excitation light, the photothermal effect of the molecules amplifies the optical signal to be measured, which further improves the sensitivity and selectivity of detection. The experimental results show that the sensitivity reaches 7.581 nm/(g•dL −1 ) with a limit of detection of 0.0026 g/dL, which is far below the blood hemoglobin level of humans (0–13 g/dL). It has been also confirmed that the sensor exhibits good selectivity. This method has the advantages of being resistant to electromagnetic interference, low cost, and is applicable for in-situ label-free detection, therefore, being potentially useful in the fields of disease diagnosis, food safety monitoring, and environmental pollution detection.


  • Niobium carbide MXene-optics fiber-sensor for high sensitivity humidity detection

    by Mingpan Bi, Yinping Miao, Wenjie Li, Jianquan Yao

    Niobium carbide (Nb2CTX) MXene is an emerging two-dimensional material and exhibits promising potential in relative humidity (RH) measurement because of its superior photoelectronic and structural properties. Here, Nb2CTX nanosheets were integrated with microfibers via an optical deposition method, and a fiber-optic-based RH sensing strategy was experimentally demonstrated. The ambient H2O molecules could be absorbed and intercalated into the Nb2CTX sheets, thereby modulating the transmission spectra of the microfiber interferometer. The RH sensing experiments showed that the transmission spectra initially blue-shifted as the RH levels increased from 18.5% to 72.4% RH, and the sensitivity was −86 pm/% RH because the effective refractive index of Nb2CTX changes, whereas the transmission spectra exhibited a red shift in the RH range of 72.4%–95.4% RH with a high sensitivity of 585 pm/% RH because of the structure of Nb2CTX variations. The combination of Nb2CTX MXene and fiber optics exhibits great prospects in the RH sensing field and brings innovative ideas for gas-sensing applications.


  • Ultrasensitive BOD Detection of Fiber Integrated With Nb2CTX MXene for Water Pollution

    by Mingpan Bi, Yinping Miao, Wenjie Li, Chengwei Fei, Kailiang Zhang

    Two-dimensional (2D) Nb2CTX MXene has outstanding physicochemical properties and great potential in biochemical sensing applications. Here, we proposed and designed an ultrasensitive microfiber sensor integrated with Nb2CTX nanosheets and tested its BOD detection power. The Nb2CTX nanosheets were coated on the microfiber surfaces to enhance BOD sensing performance. The Nb2CTX nanosheets have a sheet-like structure, large specific surface area, and hydrophilic surface functional groups that significantly increase light-matter interactions and refractive index modulation around the microfiber. The transmission spectrum red shift significantly increases with BOD concentration whereas the transmission spectrum blue shift significantly increases with external temperature. An ultrasensitivity value of 34.98 nm/mg/mL and a detection limit of 0.00057 mg/mL were obtained. These values were more than twice those obtained using the bare sensor. The temperature sensitivity was -0.41 nm/. The device had inverse spectral responses to BOD concentration and temperature. For this reason, we achieved temperature compensation by demodulating the shifts in the various transmission dips. As the proposed microfiber sensor is ultrasensitive and has temperature compensation, it is a novel and promising design for biosensing and environmental pollution monitoring.


  • Nb2CTx MXene-tilted fiber Bragg grating optofluidic system based on photothermal spectroscopy for pesticide detection

    by Wenjie Li, Yinping Miao, Tuan Guo, Kialiang Zhang, Jian-Quan Yao

    An optofluidic system based on photothermal spectroscopy is proposed, which combines molecular photothermal effect with Nb2CTx MXene-tilted fiber Bragg grating (TFBG) for the detection of organophosphorus pesticides (OPs) with temperature compensated. Under the irradiation of excitation light, the photothermal effect of OPs produces a detectable change in the refractive index of the sample, and the concentration of chlorpyrifos can be quantified using TFBG. The Nb2CTx MXene coated TFBG allow more molecules to be absorbed on the surface of TFBG, which enhances the interaction between light and matter, and improves the sensitivity of detection. The temperature compensation is performed by referring to the core mode of TFBG, thereby eliminating the influence of ambient temperature on the photothermal detection. The experimental results show that the sensitivity reaches 1.8 pm/ppm with a limit of detection (LOD) of 0.35 ppm, and the obtained temperature compensation coefficient is 4.84 ppm/°C. This photothermal biosensor has the advantages of low LOD, temperature compensation and real-time online monitoring, making it a good candidate in medicine, chemistry and environmental monitoring.


  • Enhanced photothermal signal detection by graphene oxide integrated long period fiber grating for on-site quantification of sodium copper chlorophyllin

    by Wenjie Li, Yinping Miao, Chengwei Fei, Hongmin Zhang, Bin Li, Kailiang Zhang

    An enhanced photothermal signal detection method based on graphene oxide (GO) integrated long period fiber grating (LPFG) for on-site sodium copper chlorophyllin (SCC) quantification is proposed. SCC, as a porphyrin compound, can be photonically excited to induce a stronger photothermal effect. GO offers superior molecular adsorption and thermal conductivity properties; depositing it on the LPFG surface significantly improves the sensitivity and detection efficiency of the SCC photothermal signal, when irradiated with a 405 nm laser. The experimental results showed improved performance compared with those from uncoated LPFG, with a sensitivity of 0.0587 dB (mg L−1)−1 and a limit of detection (LOD) of 0.17 mg kg−1, which is also an order of magnitude lower than that of traditional high-performance liquid chromatography. The proposed method has potential applications in the fields of real-time food safety monitoring, environmental pollutant detection, and disease diagnosis.