Ijaz Ahmed Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ijaz Ahmed Khan has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Hidayat Hussain
Heze Branch of Qilu University of Technology (Shandong Academy of Sciences)
3 shared publications Balendu C. Vasavada
Division of Cardiology, Long Island College Hospital, Brooklyn, NY, USA
2 shared publications- Tariq Yasin
Department of Chemistry Pakistan Institute of Engineering and Applied Sciences (PIEAS) Islamabad Pakistan
2 shared publications Chandra Nair
Cardiac Center of Creighton University, Omaha, NE; and
1 shared publication- Dhanunjaya Lakkireddy
Kansas City Heart Rhythm Institute, Overland Park, USA
1 shared publication Eric M. Thorn
Division of Cardiology, University of Maryland School of Medicine, Baltimore, Maryland 21201, USA
1 shared publication
Latest Publications
- Open Access
- 28 April 2021
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 45 (2) , 410-419
Fabrication and characterization of amidoxime-functionalized silica decorated with copper: a catalytic assembly for rapid reduction of dyes
In this study, amidoxime-functionalized silica decorated with copper (AFS-Cu) was fabricated and tested for its catalytic application. Fourier transform infrared spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction were employed to characterize its structure and morphology. The application of AFS-Cu as a catalyst for the catalytic reduction of methylene blue (MB) in aqueous media using NaBH4 as reductant was evaluated. The ability to reuse as well as the effect of catalyst dose and pH of solution on the catalytic activity was investigated. The reduction of MB followed pseudo-first-order kinetics and the rate constant (k) was 0.6224 min-1. AFS-Cu was found to be a highly effective catalyst for MB reduction reaction and can be easily recovered and reused several times with no appreciable loss of catalytic activity.
- 28 April 2021
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 45 (2) , 410-419
Open AccessFabrication and characterization of amidoxime-functionalized silica decorated with copper: a catalytic assembly for rapid reduction of dyes
In this study, amidoxime-functionalized silica decorated with copper (AFS-Cu) was fabricated and tested for its catalytic application. Fourier transform infrared spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction were employed to characterize its structure and morphology. The application of AFS-Cu as a catalyst for the catalytic reduction of methylene blue (MB) in aqueous media using NaBH4 as reductant was evaluated. The ability to reuse as well as the effect of catalyst dose and pH of solution on the catalytic activity was investigated. The reduction of MB followed pseudo-first-order kinetics and the rate constant (k) was 0.6224 min-1. AFS-Cu was found to be a highly effective catalyst for MB reduction reaction and can be easily recovered and reused several times with no appreciable loss of catalytic activity.
- 20 December 2019
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 137 (26)
Surface modification of mesoporous silica by radiation induced graft polymerization of styrene and subsequent sulfonation for ion‐exchange applications
In this study, the fabrication of silica‐grafted‐sulfonated styrene (S‐g‐SSt) resin by grafting of styrene onto silanized silica via gamma radiation‐induced polymerization and subsequent sulfonation of the grafted styrene is described. The grafting was strongly affected by the reaction conditions; absorbed dose, monomer concentration, and the type of solvent used. The structural analysis of the silica and all the relevant products were carried out by FTIR, SEM, TGA, XRD, and BET. FTIR analysis confirmed the presence of styrene onto silica and subsequent sulfonation. The BET nitrogen adsorption–desorption isotherms indicated that grafting occurs on the surface as well as inside the pores. Finally, the ion exchange capacity (IEC) of the fabricated S‐g‐SSt was evaluated by ion exchange titrations (back titration method). The IEC was found to be in the range of 0.43–2.97 meq/g depending on the degree of grafting. The facile fabrication method and high IEC value (2.97 meq/g) could lead to potential application of the fabricated S‐g‐SSt resin in ion exchange resin in waste water treatment and metal recovery. © 2019 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2019, 137, 48835.
- 20 December 2019
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 137 (26)
Surface modification of mesoporous silica by radiation induced graft polymerization of styrene and subsequent sulfonation for ion‐exchange applications
In this study, the fabrication of silica‐grafted‐sulfonated styrene (S‐g‐SSt) resin by grafting of styrene onto silanized silica via gamma radiation‐induced polymerization and subsequent sulfonation of the grafted styrene is described. The grafting was strongly affected by the reaction conditions; absorbed dose, monomer concentration, and the type of solvent used. The structural analysis of the silica and all the relevant products were carried out by FTIR, SEM, TGA, XRD, and BET. FTIR analysis confirmed the presence of styrene onto silica and subsequent sulfonation. The BET nitrogen adsorption–desorption isotherms indicated that grafting occurs on the surface as well as inside the pores. Finally, the ion exchange capacity (IEC) of the fabricated S‐g‐SSt was evaluated by ion exchange titrations (back titration method). The IEC was found to be in the range of 0.43–2.97 meq/g depending on the degree of grafting. The facile fabrication method and high IEC value (2.97 meq/g) could lead to potential application of the fabricated S‐g‐SSt resin in ion exchange resin in waste water treatment and metal recovery. © 2019 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2019, 137, 48835.
- 25 November 2018
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 136 (10)
Surface modification of polypropylene waste by the radiation grafting of styrene and upcycling into a cation‐exchange resin
In this study, we radiation‐grafted polypropylene waste (PPw) powder obtained from the accelerated aging of pristine polypropylene with styrene (St) using γ rays from a Co‐60 source at dose rate of 4.78 kGy/h. The influence of the variation of the γ absorbed dose, solvent types, and monomer concentration on the grafting yield was investigated. Solution grafting in methanol resulted in a higher grafting yield of 162.6% at 30 kGy in contrast to the 69.5% obtained in the absence of solvent. Grafting was found to be enhanced with the increased dilution of St with methanol. The grafted St units were incorporated with sulfonic (SO3H) groups by a sulfonation reaction with sulfuric acid. Fourier transform infrared spectroscopy, X‐ray diffraction spectrometry, scanning electron microscopy/energy‐dispersive X‐ray spectroscopy, and thermogravimetric analysis were used to characterize the grafted and sulfonated products. Sulfonation of 162.6% grafted PPw powder exhibited a maximum ion‐exchange capacity (IEC) of 3.56 mequiv/g. The utilization of PPw and its conversion into sulfonated PPw with comparable IECs is a new addition to already existing radiation grafting systems. © 2018 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2019, 136, 47145.
- 25 November 2018
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 136 (10)
Surface modification of polypropylene waste by the radiation grafting of styrene and upcycling into a cation‐exchange resin
In this study, we radiation‐grafted polypropylene waste (PPw) powder obtained from the accelerated aging of pristine polypropylene with styrene (St) using γ rays from a Co‐60 source at dose rate of 4.78 kGy/h. The influence of the variation of the γ absorbed dose, solvent types, and monomer concentration on the grafting yield was investigated. Solution grafting in methanol resulted in a higher grafting yield of 162.6% at 30 kGy in contrast to the 69.5% obtained in the absence of solvent. Grafting was found to be enhanced with the increased dilution of St with methanol. The grafted St units were incorporated with sulfonic (SO3H) groups by a sulfonation reaction with sulfuric acid. Fourier transform infrared spectroscopy, X‐ray diffraction spectrometry, scanning electron microscopy/energy‐dispersive X‐ray spectroscopy, and thermogravimetric analysis were used to characterize the grafted and sulfonated products. Sulfonation of 162.6% grafted PPw powder exhibited a maximum ion‐exchange capacity (IEC) of 3.56 mequiv/g. The utilization of PPw and its conversion into sulfonated PPw with comparable IECs is a new addition to already existing radiation grafting systems. © 2018 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2019, 136, 47145.
- 5 July 2017
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 134 (42)
Development of amidoxime functionalized silica by radiation‐induced grafting
A novel amidoxime‐based silica adsorbent was prepared by using radiation‐induced grafting technique. Grafting of acrylonitrile (AN) on silanized silica that was silanized by vinyltriethoxysilane (VTES) was carried out in solvent‐free system. The grafting of AN was increased with increasing the absorbed dose and monomer concentration in the mixture. Grafting of 748% of AN was achieved at 20 kGy dose. The nitrile groups of acrylonitrile grafted silica (AN‐g‐S) were chemically converted into amidoxime groups. The structure of AN‐g‐S and its corresponding products was investigated by FTIR, SEM, TGA, BET, and XRD analysis. FTIR and EDX analysis confirmed the grafting of AN onto silica surface. The changed morphology of SEM images shows the presence polyacrylonitrile layers on silica particles. The adsorption application of amidoxime‐grafted silica (AO‐g‐S) was studied against Cu2+. Its adsorption capacity is strongly depended on the pH of the solution and 172 (mg/g) of Cu2+ uptake was obtained at pH 5.0. The developed adsorbent has potential application to remove heavy metal ions from aqueous solutions. © 2017 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2017, 134, 45437.
- 5 July 2017
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 134 (42)
Development of amidoxime functionalized silica by radiation‐induced grafting
A novel amidoxime‐based silica adsorbent was prepared by using radiation‐induced grafting technique. Grafting of acrylonitrile (AN) on silanized silica that was silanized by vinyltriethoxysilane (VTES) was carried out in solvent‐free system. The grafting of AN was increased with increasing the absorbed dose and monomer concentration in the mixture. Grafting of 748% of AN was achieved at 20 kGy dose. The nitrile groups of acrylonitrile grafted silica (AN‐g‐S) were chemically converted into amidoxime groups. The structure of AN‐g‐S and its corresponding products was investigated by FTIR, SEM, TGA, BET, and XRD analysis. FTIR and EDX analysis confirmed the grafting of AN onto silica surface. The changed morphology of SEM images shows the presence polyacrylonitrile layers on silica particles. The adsorption application of amidoxime‐grafted silica (AO‐g‐S) was studied against Cu2+. Its adsorption capacity is strongly depended on the pH of the solution and 172 (mg/g) of Cu2+ uptake was obtained at pH 5.0. The developed adsorbent has potential application to remove heavy metal ions from aqueous solutions. © 2017 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2017, 134, 45437.
- 1 January 2008
- Published by Wolters Kluwer Health in American Journal of Therapeutics
- Vol. 15 (1) , 19-23
Does Beta Blocker Therapy Affect the Diagnostic Accuracy of Adenosine Single-Photon-Emission Computed Tomographic Myocardial Perfusion Imaging?
We retrospectively evaluated perfusion defect presence, extent, and severity in 158 consecutive patients receiving beta blockers, who underwent adenosine single-photon-emission computed tomography (SPECT) myocardial perfusion imaging (MPI) and coronary angiography. Seventy-six patients (group 1) had their beta blockers withdrawn 48 hours prior to testing, and 82 patients (group 2) remained on the beta blocker regimen. Groups 1 and 2 were similar in gender, age, pretest symptoms, and history of coronary artery disease (CAD). Group 1 patients had higher resting heart rates (79 ± 19/min versus 68 ± 13/min; P < 0.001), peak heart rates (91 ± 21/min versus 80 ± 15/min; P < 0.001), resting diastolic blood pressures (82 ± 14 mm Hg versus 74 ± 13 mm Hg; P < 0.001), peak systolic blood pressures (139 ± 23 mm Hg versus 124 ± 23 mm Hg; P < 0.001), and peak diastolic blood pressures (72 ± 12 mm Hg versus 68 ± 11 mm Hg; P = 0.04) than group 2 patients. Group 1 also had a higher incidence of angina during the 48 hours off beta blockers than group 2 (10% versus 2%; P < 0.001). There was no significant difference between the two groups in symptoms and side effects during adenosine infusion, quantitated lung/heart ratio, visually assessed lung uptake, transient ischemic dilation, post-stress ejection fraction, summed stress score, summed rest score, and summed difference score. In conclusion, in patients with CAD, beta blocker therapy does not affect the extent, severity, and reversibility of perfusion defects on adenosine SPECT MPI.
- 1 January 2008
- Published by Wolters Kluwer Health in American Journal of Therapeutics
- Vol. 15 (1) , 19-23
Does Beta Blocker Therapy Affect the Diagnostic Accuracy of Adenosine Single-Photon-Emission Computed Tomographic Myocardial Perfusion Imaging?
We retrospectively evaluated perfusion defect presence, extent, and severity in 158 consecutive patients receiving beta blockers, who underwent adenosine single-photon-emission computed tomography (SPECT) myocardial perfusion imaging (MPI) and coronary angiography. Seventy-six patients (group 1) had their beta blockers withdrawn 48 hours prior to testing, and 82 patients (group 2) remained on the beta blocker regimen. Groups 1 and 2 were similar in gender, age, pretest symptoms, and history of coronary artery disease (CAD). Group 1 patients had higher resting heart rates (79 ± 19/min versus 68 ± 13/min; P < 0.001), peak heart rates (91 ± 21/min versus 80 ± 15/min; P < 0.001), resting diastolic blood pressures (82 ± 14 mm Hg versus 74 ± 13 mm Hg; P < 0.001), peak systolic blood pressures (139 ± 23 mm Hg versus 124 ± 23 mm Hg; P < 0.001), and peak diastolic blood pressures (72 ± 12 mm Hg versus 68 ± 11 mm Hg; P = 0.04) than group 2 patients. Group 1 also had a higher incidence of angina during the 48 hours off beta blockers than group 2 (10% versus 2%; P < 0.001). There was no significant difference between the two groups in symptoms and side effects during adenosine infusion, quantitated lung/heart ratio, visually assessed lung uptake, transient ischemic dilation, post-stress ejection fraction, summed stress score, summed rest score, and summed difference score. In conclusion, in patients with CAD, beta blocker therapy does not affect the extent, severity, and reversibility of perfusion defects on adenosine SPECT MPI.
- 11 December 2006
- Published by Elsevier in International Journal of Cardiology
- Vol. 117 (3) , 370-372
Pregnancy-associated plasma protein-A: An emerging cardiac biomarker
- 11 December 2006
- Published by Elsevier in International Journal of Cardiology
- Vol. 117 (3) , 370-372
Pregnancy-associated plasma protein-A: An emerging cardiac biomarker
- 1 November 2004
- Published by Elsevier in International Journal of Cardiology
- Vol. 97 (2) , 335-337
Prolonged QT interval in acute pulmonary embolism
- 1 November 2004
- Published by Elsevier in International Journal of Cardiology
- Vol. 97 (2) , 335-337
Prolonged QT interval in acute pulmonary embolism
- 1 July 1998
- Published by S. Karger AG in Cardiology
- Vol. 90 (1) , 72-74
Separate Origins of All Three Major Coronary Arteries from the Right Sinus of Valsalva:A Rare Coronary Artery Anoma ly
The origination of all three major coronary arteries from three separate ostia in the right sinus of Valsalva is an exceedingly rare coronary anomaly. Few radiographic and clinical details of this anomaly are available in the literature. We describe this anomaly in a patient with acute myocardial infarction who remained asymptomatic until the 8th decade of her life. Atherosclerotic narrowing of the normally originating right coronary artery caused the acute myocardial infarction. Anomalous left anterior descending and left circumflex arteries were free of any significant obstruction.
- 1 July 1998
- Published by S. Karger AG in Cardiology
- Vol. 90 (1) , 72-74
Separate Origins of All Three Major Coronary Arteries from the Right Sinus of Valsalva:A Rare Coronary Artery Anoma ly
The origination of all three major coronary arteries from three separate ostia in the right sinus of Valsalva is an exceedingly rare coronary anomaly. Few radiographic and clinical details of this anomaly are available in the literature. We describe this anomaly in a patient with acute myocardial infarction who remained asymptomatic until the 8th decade of her life. Atherosclerotic narrowing of the normally originating right coronary artery caused the acute myocardial infarction. Anomalous left anterior descending and left circumflex arteries were free of any significant obstruction.