Grzegorz Gralewicz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Grzegorz Gralewicz has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Grzegorz Owczarek
Department of Personal Protective Equipment, Central Institute for Labour Protection—National Research Institute, 48 Wierzbowa Street, 90-133 Lodz, Poland
5 shared publications Janusz Kubrak
B Vigo SL , Poland
2 shared publications- Agnieszka Wolska
Department of Safety Engineering and Department of Ergonomics, Central Institute for Labour Protection—National Research Institute, Czerniakowska 16, 00-701 Warsaw, Poland
1 shared publication Bogusław Więcek
Institute of Electronics, Technical University of Łódź, Łódź, Poland
1 shared publication- Bogusław Więcek
Lodz University of Technology
1 shared publication Natalia Skuza
Uniwersytet Medyczny w Łodzi / Medical University of Lodz, Łódź, Poland (Klinika Okulistyki i Rehabilitacji Wzroku / Department of Ophthalmology and Visual Rehabilitation)
1 shared publication
Latest Publications
- Open Access
- 10 July 2017
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
- Vol. 68 (5) , 629-637
Potential impact of colors of filters used in sunglasses on the melatonin suppression process
Background: In this article the methods for determining spectral transmittance of optical radiation in the visible waveband range through selected materials used as optical filters against solar glare were described. Material and Methods: Transmittance coefficients specified for the fraction...
- 10 July 2017
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
- Vol. 68 (5) , 629-637
Open AccessPotential impact of colors of filters used in sunglasses on the melatonin suppression process
Background: In this article the methods for determining spectral transmittance of optical radiation in the visible waveband range through selected materials used as optical filters against solar glare were described. Material and Methods: Transmittance coefficients specified for the fraction...
- Open Access
- 6 October 2016
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 23 (1) , 105-109
Analysis of the selected mechanical parameters of coating of filters protecting against hazardous infrared radiation
This article presents a comparison of the test results of selected mechanical parameters (hardness, Young’s modulus, critical force for delamination) for protective filters intended for eye protection against harmful infrared radiation. Filters with reflective metallic films were studied, as well as interference filters developed at the Central Institute for Labour Protection – National Research Institute (CIOP-PIB). The test results of the selected mechanical parameters were compared with the test results, conducted in accordance with a standardised method, of simulating filter surface destruction that occurs during use.
- 6 October 2016
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 23 (1) , 105-109
Open AccessAnalysis of the selected mechanical parameters of coating of filters protecting against hazardous infrared radiation
This article presents a comparison of the test results of selected mechanical parameters (hardness, Young’s modulus, critical force for delamination) for protective filters intended for eye protection against harmful infrared radiation. Filters with reflective metallic films were studied, as well as interference filters developed at the Central Institute for Labour Protection – National Research Institute (CIOP-PIB). The test results of the selected mechanical parameters were compared with the test results, conducted in accordance with a standardised method, of simulating filter surface destruction that occurs during use.
- Open Access
- 31 March 2016
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 22 (3) , 305-309
Analysis of the selected optical parameters of filters protecting against hazardous infrared radiation
The paper analyses the selected optical parameters of protective optic filters used for protection of the eyes against hazardous radiation within the visible (VIS) and near infrared (NIR) spectrum range. The indexes characterizing transmission and reflection of optic radiation incident on the filter are compared. As it follows from the completed analysis, the newly developed interference filters provide more effective blocking of infrared radiation in comparison with the currently used protective filters.
- 31 March 2016
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 22 (3) , 305-309
Open AccessAnalysis of the selected optical parameters of filters protecting against hazardous infrared radiation
The paper analyses the selected optical parameters of protective optic filters used for protection of the eyes against hazardous radiation within the visible (VIS) and near infrared (NIR) spectrum range. The indexes characterizing transmission and reflection of optic radiation incident on the filter are compared. As it follows from the completed analysis, the newly developed interference filters provide more effective blocking of infrared radiation in comparison with the currently used protective filters.
- Open Access
- 11 February 2015
- Published by Taylor & Francis in Cogent Engineering
- Vol. 2 (1)
Changes of transmission characteristics for different optic radiation incidence angles in filters protecting against hazardous infrared radiation
- 11 February 2015
- Published by Taylor & Francis in Cogent Engineering
- Vol. 2 (1)
Open AccessChanges of transmission characteristics for different optic radiation incidence angles in filters protecting against hazardous infrared radiation
- 8 January 2009
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 15 (4) , 363-371
Active Thermography in Qualitative Evaluation of Protective Materials
This is a study of the possibilities of a qualitative evaluation of protective materials with active thermography. It presents a simulation of a periodic excitation of a multilayer composite material. Tests were conducted with lock-in thermography on Kevlar composite consisting of 16 layers of Kevlar fabric reinforced with formaldehyde resin with implanted delamination defects. Lock-in thermography is a versatile tool for nondestructive evaluation. It is a fast, remote and nondestructive procedure. Hence, it was used to detect delaminations in the composite structure of materials used in the production of components designed for personal protection. This method directly contributes to an improvement in safety.
- 8 January 2009
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 15 (4) , 363-371
Active Thermography in Qualitative Evaluation of Protective Materials
This is a study of the possibilities of a qualitative evaluation of protective materials with active thermography. It presents a simulation of a periodic excitation of a multilayer composite material. Tests were conducted with lock-in thermography on Kevlar composite consisting of 16 layers of Kevlar fabric reinforced with formaldehyde resin with implanted delamination defects. Lock-in thermography is a versatile tool for nondestructive evaluation. It is a fast, remote and nondestructive procedure. Hence, it was used to detect delaminations in the composite structure of materials used in the production of components designed for personal protection. This method directly contributes to an improvement in safety.
- 8 January 2005
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 11 (2) , 211-215
Investigations of Single and Multilayer Structures Using Lock-In Thermography—Possible Applications
This paper presents a study of the possibilities of evaluating thermal parameters of single and multilayer structures using dynamic thermography. It also discusses potential uses of lock-in thermography. It presents a simulation of a periodic excitation of a multilayer composite material. In practice, the described methods can be employed in various applications, for example, in multilayer nonwoven microelectronic components manufactured from hemp fibers, chemical fibers, with an addition of electrically conducting fibers, and in medicine and biology. This paper describes tests conducted with lock-in thermography on carbon fibre reinforced composites with implanted delamination defects. Lock-in thermography is a versatile tool for non-destructive evaluation (NDE). Lock-in thermography is a fast, remote and non-destructive procedure. Hence, it has been used to detect delaminations in the composite structure of aircraft. This method directly contributes to an improvement in safety.
- 8 January 2005
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 11 (2) , 211-215
Investigations of Single and Multilayer Structures Using Lock-In Thermography—Possible Applications
This paper presents a study of the possibilities of evaluating thermal parameters of single and multilayer structures using dynamic thermography. It also discusses potential uses of lock-in thermography. It presents a simulation of a periodic excitation of a multilayer composite material. In practice, the described methods can be employed in various applications, for example, in multilayer nonwoven microelectronic components manufactured from hemp fibers, chemical fibers, with an addition of electrically conducting fibers, and in medicine and biology. This paper describes tests conducted with lock-in thermography on carbon fibre reinforced composites with implanted delamination defects. Lock-in thermography is a versatile tool for non-destructive evaluation (NDE). Lock-in thermography is a fast, remote and non-destructive procedure. Hence, it has been used to detect delaminations in the composite structure of aircraft. This method directly contributes to an improvement in safety.