Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Laura de Cubas has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Use of Genetically Encoded Reporters to Quantify Intracellular H2O2 Levels in Eukaryotic Cells

    by Laura de Cubas, Fernando Antunes, Olga Lyublinskaya, Elena Hidalgo

    The synthesis and scavenging of hydrogen peroxide (H2O2) is tightly regulated in all cell types. H2O2 can fluctuate from low, physiological levels to intermediate, signaling ones and can further raise to participate in toxic reactions. Cell membranes contribute to the generation of gradients between the extracellular and intracellular media, as well as between cellular compartments. Elucidating steady-state levels of H2O2 at different cell compartments and the gradients across membranes is essential to understand redox signaling and toxicity effects. The most efficient tools for specific, quantitative, spatial, and timely measurements of H2O2 are genetically encoded biosensors of two families: redox-sensitive (ro)GFP fused to peroxiredoxins and HyPer derivatives. We will briefly describe here the advantages of three members of these families (roGFP2-Tpx1.C169S, HyPer, and Hyper7) and how the application of mathematical equations to the experimental data obtained with these probes has proven very useful to determine peroxide gradients across membranes, and can be used for calculating absolute and relative steady-state levels of H2O2 in different eukaryotic models.

  • Open Access

    Expression of the H2O2 Biosensor roGFP-Tpx1.C169S in Fission and Budding Yeasts and Jurkat Cells to Compare Intracellular H2O2 Levels, Transmembrane Gradients, and Response to Metals

    by Laura de Cubas, Jorge Mallor, Víctor Herrera-Fernández, José Ayté, Rubén Vicente, Elena Hidalgo

    Intracellular hydrogen peroxide (H2O2) levels can oscillate from low, physiological concentrations, to intermediate, signaling ones, and can participate in toxic reactions when overcoming certain thresholds. Fluorescent protein-based reporters to measure intracellular H2O2 have been developed in recent decades. In particular, the redox-sensitive green fluorescent protein (roGFP)-based proteins fused to peroxiredoxins are among the most sensitive H2O2 biosensors. Using fission yeast as a model system, we recently demonstrated that the gradient of extracellular-to-intracellular peroxides through the plasma membrane is around 300:1, and that the concentration of physiological H2O2 is in the low nanomolar range. Here, we have expressed the very sensitive probe roGFP2-Tpx1.C169S in two other model systems, budding yeast and human Jurkat cells. As in fission yeast, the biosensor is ~40–50% oxidized in these cell types, suggesting similar peroxide steady-state levels. Furthermore, probe oxidation upon the addition of extracellular peroxides is also quantitatively similar, suggesting comparable plasma membrane H2O2 gradients. Finally, as a proof of concept, we have applied different concentrations of zinc to all three model systems and have detected probe oxidation, demonstrating that an excess of this metal can cause fluctuations of peroxides, which are moderate in yeasts and severe in mammalian cells. We conclude that the principles governing H2O2 fluxes are very similar in different model organisms.


  • Open Access

    The Mitochondria-to-Cytosol H2O2 Gradient Is Caused by Peroxiredoxin-Dependent Cytosolic Scavenging

    by Laura de Cubas, Valeriy V. Pak, Vsevolod V. Belousov, José Ayté, Elena Hidalgo

    Fluorescent protein-based reporters used to measure intracellular H2O2 were developed to overcome the limitations of small permeable dyes. The two major families of genetically encoded redox reporters are the reduction-oxidation sensitive green fluorescent protein (roGFP)-based proteins fused to peroxiredoxins and HyPer and derivatives. We have used the most sensitive probes of each family, roGFP2-Tpx1.C169S and HyPer7, to monitor steady-state and fluctuating levels of peroxides in fission yeast. While both are able to monitor the nanomolar fluctuations of intracellular H2O2, the former is two-five times more sensitive than HyPer7, and roGFP2-Tpx1.C169S is partially oxidized in the cytosol of wild-type cells while HyPer7 is fully reduced. We have successfully expressed HyPer7 in the mitochondrial matrix, and it is ~40% oxidized, suggesting higher steady-state levels of peroxides, in the low micromolar range, than in the cytosol. Cytosolic HyPer7 can detect negligible H2O2 in the cytosol from mitochondrial origin unless the main H2O2 scavenger, the cytosolic peroxiredoxin Tpx1, is absent, while mitochondrial HyPer7 is oxidized to the same extent in wild-type and ∆tpx1 cells. We conclude that there is a bidirectional flux of H2O2 across the matrix and the cytosol, but Tpx1 rapidly and efficiently scavenges mitochondrial-generated peroxides and stops their steady-state cytosolic levels rising.