Robert Groth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Robert Groth has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Sadegh Niazi
School of Science, Located On Darug Country, Western Sydney University, Richmond, Australia
5 shared publications - Zoran Ristovski
International Laboratory for Air Quality and Health, Queensland University of Technology, Brisbane, Australia
5 shared publications - Graham Richard Johnson
Queensland University of Technology (QUT), Faculty of Science, School of Earth and Atmospheric Sciences, Brisbane 4001, Australia
3 shared publications Kirsten Spann
Queensland University of Technology (QUT)
2 shared publications- Lidia Morawska
Queensland University of Technology
2 shared publications Allen E. Haddrell
School of Chemistry, Cantock’s Close, University of Bristol, Bristol BS8 1TS, United Kingdom
1 shared publication
Latest Publications
- 14 September 2026
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (10) , 2484-2502
Germicidal UV for the Control of Airborne Bacteria and Viruses: A Critical Review of Efficacy and the Production of Secondary Pollutants
Germicidal ultraviolet radiation (GUV) has long been a promising solution to indoor transmission of airborne diseases, but has not yet seen widespread adoption. This review addresses: the efficacy of GUV in inactivating airborne pathogens in laboratory experiments; the effect of pathogen structural characteristics and taxonomy on GUV susceptibility; and evidence that GUV produces airborne pollutants, all of which are key challenges to the widespread adoption of this technology. With respect to the first objective, the median susceptibility constants Z for viruses and bacteria across all wavelengths were 2.2 cm2 mJ–1 and 3.5 cm2 mJ–1, respectively. GUV using 222 nm radiation has higher exposure thresholds than 254 nm, which permits a higher dose and is therefore likely more efficacious in practice. For the second objective, there is a difference in efficacy between bacterial families, dependent on cell wall characteristics, but there are not enough studies on viruses to determine whether their structural properties influence UV susceptibility. For the third objective, both 222 and 254 nm can generate air pollutants that differ in composition, quantity, and production pathways, and under some conditions can be at harmful levels. However, operating the devices at fluence rates within guideline limits and with adequate ventilation appears to greatly mitigate the risk of pollutant accumulation. The potential for human harm from these pollutants, however, is still concerning and requires a combination of adequate ventilation, consistent monitoring, and intelligent building systems to completely safeguard against human exposure to high levels of pollutants over prolonged periods. Exposure to high concentrations of pollutants leads to morbidity, and so confidence in the ability to prevent pollutant accumulation must be absolute prior to the implementation of GUV.
- 14 September 2026
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (10) , 2484-2502
Germicidal UV for the Control of Airborne Bacteria and Viruses: A Critical Review of Efficacy and the Production of Secondary Pollutants
Germicidal ultraviolet radiation (GUV) has long been a promising solution to indoor transmission of airborne diseases, but has not yet seen widespread adoption. This review addresses: the efficacy of GUV in inactivating airborne pathogens in laboratory experiments; the effect of pathogen structural characteristics and taxonomy on GUV susceptibility; and evidence that GUV produces airborne pollutants, all of which are key challenges to the widespread adoption of this technology. With respect to the first objective, the median susceptibility constants Z for viruses and bacteria across all wavelengths were 2.2 cm2 mJ–1 and 3.5 cm2 mJ–1, respectively. GUV using 222 nm radiation has higher exposure thresholds than 254 nm, which permits a higher dose and is therefore likely more efficacious in practice. For the second objective, there is a difference in efficacy between bacterial families, dependent on cell wall characteristics, but there are not enough studies on viruses to determine whether their structural properties influence UV susceptibility. For the third objective, both 222 and 254 nm can generate air pollutants that differ in composition, quantity, and production pathways, and under some conditions can be at harmful levels. However, operating the devices at fluence rates within guideline limits and with adequate ventilation appears to greatly mitigate the risk of pollutant accumulation. The potential for human harm from these pollutants, however, is still concerning and requires a combination of adequate ventilation, consistent monitoring, and intelligent building systems to completely safeguard against human exposure to high levels of pollutants over prolonged periods. Exposure to high concentrations of pollutants leads to morbidity, and so confidence in the ability to prevent pollutant accumulation must be absolute prior to the implementation of GUV.
- 14 May 2026
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (6) , 1655-1663
Physicochemical Diversity of Cough-Generated Respiratory Particles Revealed by Single Particle Analysis
- 14 May 2026
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 3 (6) , 1655-1663
Physicochemical Diversity of Cough-Generated Respiratory Particles Revealed by Single Particle Analysis
- 14 February 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (8) , 3595-3608
Toward Standardized Aerovirology: A Critical Review of Existing Results and Methodologies
Understanding the airborne survival of viruses is important for public health and epidemiological modeling and potentially to develop mitigation strategies to minimize the transmission of airborne pathogens. Laboratory experiments typically involve investigating the effects of environmental parameters on the viability or infectivity of a target airborne virus. However, conflicting results among studies are common. Herein, the results of 34 aerovirology studies were compared to identify links between environmental and compositional effects on the viability of airborne viruses. While the specific experimental apparatus was not a factor in variability between reported results, it was determined that the experimental procedure was a major factor that contributed to discrepancies in results. The most significant contributor to variability between studies was poorly defined initial viable virus concentration in the aerosol phase, causing many studies to not measure the rapid inactivation, which occurs quickly after particle generation, leading to conflicting results. Consistently, studies that measured their reference airborne viability minutes after aerosolization reported higher viability at subsequent times, which indicates that there is an initial loss of viability which is not captured in these studies. The composition of the particles which carry the viruses was also found to be important in the viability of airborne viruses; however, the mechanisms for this effect are unknown. Temperature was found to be important for aerosol-phase viability, but there is a lack of experiments that directly compare the effects of temperature in the aerosol phase and the bulk phase. There is a need for repeated measurements between different research groups under identical conditions both to assess the degree of variability between studies and also to attempt to better understand already published data. Lack of experimental standardization has hindered the ability to quantify the differences between studies, for which we provide recommendations for future studies. These recommendations are as follows: measuring the reference airborne viability using the "direct method"; use equipment which maximizes time resolution; quantify all losses appropriately; perform, at least, a 5- and 10-min sample, if possible; report clearly the composition of the virus suspension; measure the composition of the gas throughout the experiment. Implementing these recommendations will address the most significant oversights in the existing literature and produce data which can more easily be quantitatively compared.
- 14 February 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (8) , 3595-3608
Toward Standardized Aerovirology: A Critical Review of Existing Results and Methodologies
Understanding the airborne survival of viruses is important for public health and epidemiological modeling and potentially to develop mitigation strategies to minimize the transmission of airborne pathogens. Laboratory experiments typically involve investigating the effects of environmental parameters on the viability or infectivity of a target airborne virus. However, conflicting results among studies are common. Herein, the results of 34 aerovirology studies were compared to identify links between environmental and compositional effects on the viability of airborne viruses. While the specific experimental apparatus was not a factor in variability between reported results, it was determined that the experimental procedure was a major factor that contributed to discrepancies in results. The most significant contributor to variability between studies was poorly defined initial viable virus concentration in the aerosol phase, causing many studies to not measure the rapid inactivation, which occurs quickly after particle generation, leading to conflicting results. Consistently, studies that measured their reference airborne viability minutes after aerosolization reported higher viability at subsequent times, which indicates that there is an initial loss of viability which is not captured in these studies. The composition of the particles which carry the viruses was also found to be important in the viability of airborne viruses; however, the mechanisms for this effect are unknown. Temperature was found to be important for aerosol-phase viability, but there is a lack of experiments that directly compare the effects of temperature in the aerosol phase and the bulk phase. There is a need for repeated measurements between different research groups under identical conditions both to assess the degree of variability between studies and also to attempt to better understand already published data. Lack of experimental standardization has hindered the ability to quantify the differences between studies, for which we provide recommendations for future studies. These recommendations are as follows: measuring the reference airborne viability using the "direct method"; use equipment which maximizes time resolution; quantify all losses appropriately; perform, at least, a 5- and 10-min sample, if possible; report clearly the composition of the virus suspension; measure the composition of the gas throughout the experiment. Implementing these recommendations will address the most significant oversights in the existing literature and produce data which can more easily be quantitatively compared.
- Open Access
- 21 October 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (20) , 13706
The Effectiveness of Ultraviolet-C (UV-C) Irradiation on the Viability of Airborne Pseudomonas aeruginosa
Pseudomonas aeruginosa (Pa) is the predominant bacterial pathogen in people with cystic fibrosis (CF) and can be transmitted by airborne droplet nuclei. Little is known about the ability of ultraviolet band C (UV-C) irradiation to inactivate Pa at doses and conditions relevant to implementation in indoor clinical settings. We assessed the effectiveness of UV-C (265 nm) at up to seven doses on the decay of nebulized Pa aerosols (clonal Pa strain) under a range of experimental conditions. Experiments were done in a 400 L rotating sampling drum. A six-stage Andersen cascade impactor was used to collect aerosols inside the drum and the particle size distribution was characterized by an optical particle counter. UV-C effectiveness was characterized relative to control tests (no UV-C) of the natural decay of Pa. We performed 112 tests in total across all experimental conditions. The addition of UV-C significantly increased the inactivation of Pa compared with natural decay alone at all but one of the UV-C doses assessed. UV-C doses from 246–1968 µW s/cm2 had an estimated effectiveness of approximately 50–90% for airborne Pa. The effectiveness of doses ≥984 µW s/cm2 were not significantly different from each other (p-values: 0.365 to ~1), consistent with a flattening of effectiveness at higher doses. Modelling showed that delivering the highest dose associated with significant improvement in effectiveness (984 µW s/cm2) to the upper air of three clinical rooms would lead to lower room doses from 37–49% of the 8 h occupational limit. Our results suggest that UV-C can expedite the inactivation of nebulized airborne Pa under controlled conditions, at levels that can be delivered safely in occupied settings. These findings need corroboration, but UV-C may have potential applications in locations where people with CF congregate, coupled with other indoor and administrative infection control measures.
- 21 October 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (20) , 13706
Open AccessThe Effectiveness of Ultraviolet-C (UV-C) Irradiation on the Viability of Airborne Pseudomonas aeruginosa
Pseudomonas aeruginosa (Pa) is the predominant bacterial pathogen in people with cystic fibrosis (CF) and can be transmitted by airborne droplet nuclei. Little is known about the ability of ultraviolet band C (UV-C) irradiation to inactivate Pa at doses and conditions relevant to implementation in indoor clinical settings. We assessed the effectiveness of UV-C (265 nm) at up to seven doses on the decay of nebulized Pa aerosols (clonal Pa strain) under a range of experimental conditions. Experiments were done in a 400 L rotating sampling drum. A six-stage Andersen cascade impactor was used to collect aerosols inside the drum and the particle size distribution was characterized by an optical particle counter. UV-C effectiveness was characterized relative to control tests (no UV-C) of the natural decay of Pa. We performed 112 tests in total across all experimental conditions. The addition of UV-C significantly increased the inactivation of Pa compared with natural decay alone at all but one of the UV-C doses assessed. UV-C doses from 246–1968 µW s/cm2 had an estimated effectiveness of approximately 50–90% for airborne Pa. The effectiveness of doses ≥984 µW s/cm2 were not significantly different from each other (p-values: 0.365 to ~1), consistent with a flattening of effectiveness at higher doses. Modelling showed that delivering the highest dose associated with significant improvement in effectiveness (984 µW s/cm2) to the upper air of three clinical rooms would lead to lower room doses from 37–49% of the 8 h occupational limit. Our results suggest that UV-C can expedite the inactivation of nebulized airborne Pa under controlled conditions, at levels that can be delivered safely in occupied settings. These findings need corroboration, but UV-C may have potential applications in locations where people with CF congregate, coupled with other indoor and administrative infection control measures.
- 19 July 2022
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 56 (15) , 10879-10890
Nanomechanics and Morphology of Simulated Respiratory Particles
The impact of respiratory particle composition on the equilibrium morphology and phase is not well understood. Furthermore, the effects of these different phases and morphologies on the viability of viruses embedded within these particles are equally unknown. Physiologically relevant respiratory fluid analogues were constructed, and their hygroscopic behavior was measured using an ensemble technique. A relationship between hygroscopicity and protein concentration was determined, providing additional validation to the high protein content of respiratory aerosol measured in prior works (>90%). It was found that the salt component of the respiratory particles could crystallize as a single crystal, multiple crystals, or would not crystallize at all. It was found that dried protein particles at indoor-relevant climatic conditions could exist separately in a glassy (∼77% of particles) or viscoelastic state (∼23% of particles). The phase state and morphology of respiratory particles may influence the viability of embedded pathogens. We recommend that pathogen research aiming to mimic the native composition of respiratory fluid should use a protein concentration of at least 90% by solute volume to improve the representativity of the pathogen's microenvironment.
- 19 July 2022
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 56 (15) , 10879-10890
Nanomechanics and Morphology of Simulated Respiratory Particles
The impact of respiratory particle composition on the equilibrium morphology and phase is not well understood. Furthermore, the effects of these different phases and morphologies on the viability of viruses embedded within these particles are equally unknown. Physiologically relevant respiratory fluid analogues were constructed, and their hygroscopic behavior was measured using an ensemble technique. A relationship between hygroscopicity and protein concentration was determined, providing additional validation to the high protein content of respiratory aerosol measured in prior works (>90%). It was found that the salt component of the respiratory particles could crystallize as a single crystal, multiple crystals, or would not crystallize at all. It was found that dried protein particles at indoor-relevant climatic conditions could exist separately in a glassy (∼77% of particles) or viscoelastic state (∼23% of particles). The phase state and morphology of respiratory particles may influence the viability of embedded pathogens. We recommend that pathogen research aiming to mimic the native composition of respiratory fluid should use a protein concentration of at least 90% by solute volume to improve the representativity of the pathogen's microenvironment.
- Open Access
- 1 June 2022
- Published by American Chemical Society (ACS) in ChemRxiv
Nanomechanics and morphology of simulated respiratory particles
The impact of respiratory particle composition on the equilibrium morphology and phase are not well understood. Furthermore, the effects of these different phases and morphologies on the viability of viruses embedded within these particles are equally unknown. Physiologically relevant respiratory fluid analogues were constructed, and their hygroscopic behavior were measured using an ensemble technique. A relationship between hygroscopicity and protein concentration was determined, providing additional validation to the high protein content of respiratory aerosol measured in prior works (>90%). It was found that the salt component of the respiratory particles could crystallize as a single crystal, multiple crystals, or would not crystallize at all. It was found that dried protein particles at indoor-relevant climatic conditions could exist separately in a glassy (~77% of particles) or viscoelastic state (~23% of particles). The phase state and morphology of respiratory particles may influence the viability of embedded pathogens. We recommend that pathogen research aiming to mimic the native composition of respiratory fluid should use a protein concentration of at least 90% by solute volume to improve the representativity of the pathogen’s microenvironment.
- 1 June 2022
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessNanomechanics and morphology of simulated respiratory particles
The impact of respiratory particle composition on the equilibrium morphology and phase are not well understood. Furthermore, the effects of these different phases and morphologies on the viability of viruses embedded within these particles are equally unknown. Physiologically relevant respiratory fluid analogues were constructed, and their hygroscopic behavior were measured using an ensemble technique. A relationship between hygroscopicity and protein concentration was determined, providing additional validation to the high protein content of respiratory aerosol measured in prior works (>90%). It was found that the salt component of the respiratory particles could crystallize as a single crystal, multiple crystals, or would not crystallize at all. It was found that dried protein particles at indoor-relevant climatic conditions could exist separately in a glassy (~77% of particles) or viscoelastic state (~23% of particles). The phase state and morphology of respiratory particles may influence the viability of embedded pathogens. We recommend that pathogen research aiming to mimic the native composition of respiratory fluid should use a protein concentration of at least 90% by solute volume to improve the representativity of the pathogen’s microenvironment.
- Open Access
- 5 May 2021
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 18 (178) , 20210209
In situ measurements of human cough aerosol hygroscopicity
The airborne dynamics of respiratory droplets, and the transmission routes of pathogens embedded within them, are governed primarily by the diameter of the particles. These particles are composed of the fluid which lines the respiratory tract, and is primarily mucins and salts, which will interact with the atmosphere and evaporate to reach an equilibrium diameter. Measuring organic volume fraction (OVF) of cough aerosol has proved challenging due to large variability and low material volume produced after coughing. Here, the diametric hygroscopic growth factors (GF) of the cough aerosol produced by healthy participants were measured in situ using a rotating aerosol suspension chamber and a humidification tandem differential mobility analyser. Using hygroscopicity models, it was estimated that the average OVF in the evaporated cough aerosol was 0.88 ± 0.07 and the average GF at 90% relative humidity (RH) was 1.31 ± 0.03. To reach equilibrium in dry air the droplets will reduce in diameter by a factor of approximately 2.8 with an evaporation factor of 0.36 ± 0.05. Hysteresis was observed in cough aerosol at RH = ∼35% and RH = ∼65% for efflorescence and deliquescence, respectively, and may depend on the OVF. The same behaviour and GF were observed in nebulized bovine bronchoalveolar lavage fluid.
- 5 May 2021
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 18 (178) , 20210209
Open AccessIn situ measurements of human cough aerosol hygroscopicity
The airborne dynamics of respiratory droplets, and the transmission routes of pathogens embedded within them, are governed primarily by the diameter of the particles. These particles are composed of the fluid which lines the respiratory tract, and is primarily mucins and salts, which will interact with the atmosphere and evaporate to reach an equilibrium diameter. Measuring organic volume fraction (OVF) of cough aerosol has proved challenging due to large variability and low material volume produced after coughing. Here, the diametric hygroscopic growth factors (GF) of the cough aerosol produced by healthy participants were measured in situ using a rotating aerosol suspension chamber and a humidification tandem differential mobility analyser. Using hygroscopicity models, it was estimated that the average OVF in the evaporated cough aerosol was 0.88 ± 0.07 and the average GF at 90% relative humidity (RH) was 1.31 ± 0.03. To reach equilibrium in dry air the droplets will reduce in diameter by a factor of approximately 2.8 with an evaporation factor of 0.36 ± 0.05. Hysteresis was observed in cough aerosol at RH = ∼35% and RH = ∼65% for efflorescence and deliquescence, respectively, and may depend on the OVF. The same behaviour and GF were observed in nebulized bovine bronchoalveolar lavage fluid.