HHHitoshi Hachiya

Hitoshi Hachiya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hitoshi Hachiya has a total of 169 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Left Atrial Calcification After Atrial Fibrillation Ablation Predicts Long-term Risk of Heart Failure Hospitalization

    by Tadanori Nakata, Naoyuki Miwa, Satoshi Hara, Hikaru Shimosato, Mirei Setoguchi, Taiki Ishizawa, Hidenori Hirano, Yoshikazu Sato, Shigeki Kusa, Hitoshi Hachiya, et al.

    Background: Left atrial calcification (LAC) after atrial fibrillation (AF) ablation has recently been described, but its clinical significance and determinants remain insufficiently defined. Methods: Among 1,741 patients who underwent first-time radiofrequency AF ablation between 2011 and 2018, 231 patients underwent both pre- and post-ablation chest CT. Patients were classified into an LAC group (n=71) and a non-LAC group (n=160). Baseline characteristics, ablation parameters, and calcification sites were analyzed. Independent predictors of LAC formation were identified using Cox proportional hazards models. Clinical outcomes, including heart failure (HF) hospitalization, stroke, and a composite endpoint of all-cause mortality, HF, stroke, or coronary intervention, were compared during long-term follow-up. Results: Over a mean follow-up of 9.5 ± 2.7 years, LAC was detected in 31% of patients, typically 7.3 ± 3.1 years after ablation. LAC occurred most frequently at the lateral mitral annulus and right pulmonary veins. Independent predictors of LAC formation were non-paroxysmal AF (HR 1.7, 95% CI 1.0–2.8, p=0.04), LA diameter >50 mm (HR 2.7, 95% CI 1.3–5.5, p<0.01), and ablation beyond the pulmonary veins (HR 2.3, 95% CI 1.3–4.2, p=0.04). Kaplan–Meier analysis showed significantly higher HF hospitalization in the LAC group (log-rank p=0.02), while stroke incidence was similar between groups (p=0.50). The composite endpoint occurred more frequently in the LAC group (p=0.05). Conclusion: LAC is a not uncommon late finding after AF ablation, particularly in patients with advanced atrial remodeling or extensive ablation. Its presence is associated with a higher risk of HF hospitalization, underscoring the importance of procedural planning and long-term imaging surveillance in AF ablation patients.

  • Open Access

    Impact of cryoballoon size adjustability on procedural and clinical outcomes

    by Naoya Kikkoji, Shinsuke Miyazaki, Junichi Nitta, Takeshi Sasaki, Yasuteru Yamauchi, Shu Yamashita, Yuichiro Sagawa, Yasuhiro Shirai, Osamu Inaba, Atsushi Suzuki, et al.


  • Outcomes of Exclusive 50 W High Power, 5 s Ablation Close to the Esophagus in Pulmonary Vein Isolation

    by Yoshikazu Sato, Shigeki Kusa, Naoyuki Miwa, Satoshi Hara, Tadanori Nakata, Hidenori Hirano, Taiki Ishizawa, Tomohiro Tahara, Tetsuo Sasano, Hitoshi Hachiya

    Background: In pulmonary vein isolation (PVI) employing a high‐power and short‐duration (HP‐SD) strategy, no consensus exists regarding the optimal settings for radiofrequency application (RFA) to the section of left atrium adjacent to the esophagus (esophageal area, EA).Objective: To evaluate (1) the efficacy and safety of HP‐SD RFA with 50 W for 5 s on the EA, and (2) the predictive factors of esophageal thermal injury (ETI).Methods: We performed esophagogastroduodenoscopy on 85 patients who had undergone PVI with 50 W RFA. RFA duration was limited to 5 s on the EA.Results: Of the 85 patients, 16 (18.8%) developed asymptomatic thermal injury (1 mucosal injury, namely erosion and 15 gastric hypomotility). All of those were asymptomatic and transient, and any symptomatic or severe, esophageal or gastric complications was not observed. On the EA, conduction block was achieved after the first encircling in 82 (96.5%) patients. The number of RFA on the EA and the proportion of patients whose EA was located at the posterior wall of the right inferior PV (right‐sided EA) were higher in the patients with ETI than without (9.0 [7.0−10.5] vs. 7.0 [5.0−9.0] p = 0.021, and 18.8% vs. 2.9%, p = 0.044, respectively). In multivariate analysis, the number of RFA on the EA (hazard ratio 1.32, p = 0.019) and RFA on the right‐sided EA (hazard ratio, 13.50, p = 0.013) were identified as the predictors of ETI.Conclusion: RFA of 50 W for 5 s on the EA can be performed with a low incidence of esophageal mucosal injury while maintaining efficacy. RFA on the right‐sided EA and the high number of RFA on the EA increase the risk of ETI.


  • A Case of Ventricular Premature Contractions With Multiple Morphologies Reproduced by a Single Ventricular Extrastimulus With Different Coupling Intervals

    by Naoyuki Miwa, Tadanori Nakata, Satoshi Hara, Tomohiro Tahara, Taiki Ishizawa, Hidenori Hirano, Yoshikazu Sato, Shigeki Kusa, Hitoshi Hachiya

    Introduction: A 22‐year‐old male with no cardiovascular history presented with frequent symptomatic ventricular premature contractions (VPCs) with multiple QRS morphologies despite bisoprolol treatment.Results: The coupling intervals progressively increased from VPC1 to VPC3, and VPC2 was the most frequent. The earliest activation site was identified at the left‐right coronary cusp junction. Single ventricular extrastimuli with variable coupling intervals from this site successfully reproduced QRS morphologies identical to VPC1‐3.Conclusion: This case illustrated how a single focus VPC could exhibit multiform morphology due to varying fusion with intrinsic conduction and the importance of coupling interval‐matched extrastimuli in identifying the origin.

  • Open Access

    A case of ventricular premature contractions with multiple morphologies reproduced by a single ventricular extrastimulus with different coupling intervals

    by Naoyuki Miwa, Tadanori Nakata, Satoshi Hara, Tomohiro Tahara, Taiki Ishizawa, Hidenori Hirano, Yoshikazu Sato, Shigeki Kusa, Hitoshi Hachiya

    ; Introduction: A 22-year-old male with no prior cardiovascular history presented with frequent symptomatic ventricular premature contractions (VPCs) with multiple QRS morphologies despite bisoprolol treatment. Results: The coupling intervals progressively increased from VPC1 to VPC3, and VPC2 was the most frequent (VPC1: 9.3%, VPC2: 30.2%, VPC3: 0.5%). The earliest activation site was identified at the left-right coronary cusp junction. Single ventricular extrastimuli with variable coupling intervals from this site successfully reproduced QRS morphologies identical to VPC 1-3. Conclusion: The findings revealed the utility of unique pace-mapping technique in cases of VPCs with multiple morphologies.

  • A slightly irregular SVT: What is the mechanism?

    by Hitoshi Hachiya, Shigeki Kusa, Satoshi Hara, Taiki Ishizawa, Hidenori Hirano, Tadanori Nakata, Junichi Doi, Yoshikazu Sato, Naoyuki Miwa

  • Open Access

    Incidence of phrenic nerve injury during pulmonary vein isolation using different cryoballoons: data from a large prospective ablation registry

    by Shinichi Tachibana, Shinsuke Miyazaki, Junichi Nitta, Yasuhiro Shirai, Yasutoshi Nagata, Yuichiro Sagawa, Yukio Sekiguchi, Yukihiro Inamura, Takeshi Sasaki, Yasuteru Yamauchi, et al.

    Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


  • Open Access

    Relationship between the atrial‐activation pattern around the triangle of Koch and successful ablation sites in slow‐fast atrioventricular nodal reentrant tachycardia

    by Tomonori Watanabe, Hitoshi Hachiya, Hiroaki Watanabe, Kazunori Anno, Takafumi Okuyama, Tomohiko Harunari, Ayako Yokota, Masashi Kamioka, Takahiro Komori, Yuko Torigoe‐Kurosu, et al.

    Background: The precise details of atrial activation around the triangle of Koch (ToK) remain unknown. We evaluated the relationship between the atrial‐activation pattern around the ToK and success sites for slow‐pathway (SP) modification ablation in slow‐fast atrioventricular reentrant tachycardia (AVNRT).Methods: Thirty patients with slow‐fast AVNRT who underwent successful ablation were enrolled. Atrial activation around the ToK during sinus rhythm was investigated using ultra‐high‐density mapping pre‐ablation. The relationships among features of atrial‐activation pattern and success sites were examined.Results: Of 30 patients (22 cryoablation; 8 radiofrequency ablation), 26 patients had a collision site of two wavefronts of delayed atrial activation within ToK, indicating a success site. The activation‐search function of Lumipoint software, which highlights only atrial activation with a spatiotemporal consistency, showed non‐highlighted area on the tricuspid‐annulus side of ToK. In 23 of the patients, a spiky potential was recorded at that collision site outside the Lumipoint‐highlighted area. Fifteen cryoablation patients with a success site coincident with a collision site outside the Lumipoint‐highlighted area had significantly more frequent disappearances of SP after initial cryoablation (46.7% vs. 0%, p = .029), fewer cryoablations (3.7 ± 1.8 vs. 5.3 ± 1.3, p = .045), and shorter procedure times (170 ± 57 vs. 228 ± 91 min, p = .082) compared to the seven cryoablation patients without such sites. Four patients had transient AV block by ablation inside the Lumipoint‐highlighted area with fractionated signals, but no patient developed permanent AV block or recurrence post‐procedure (median follow‐up: 375 days).Conclusions: SP modification ablation at the collision site of atrial activation of the tricuspid‐annulus side along with a spiky potential could provide a better outcome.


  • Differences between typical and reverse typical atrial flutter identified by ultrahigh resolution mapping

    by Satoshi Hara, Yoshikazu Sato, Shigeki Kusa, Naoyuki Miwa, Hidenori Hirano, Tadanori Nakata, Junichi Doi, Hitoshi Hachiya

    Background: Although atrial flutter (AFL) is a common arrhythmia that is based on a macro‐reentrant tachycardia around the tricuspid annulus, the factors giving rise to typical AFL (t‐AFL) versus reverse typical AFL (rt‐AFL) are unknown. To investigate the difference between t‐AFL and rt‐AFL circuits using ultrahigh resolution mapping of the right atrium.Methods: We investigated 30 isthmus‐dependent AFL patients (mean age 71, 28 male) who underwent first‐time cavo‐tricuspid isthmus (CTI) ablation guided by Boston Scientific's Rhythmia mapping system and divided them into two groups: t‐AFL (22 patients) and rt‐AFL (8 patients). We compared the anatomy and electrophysiology of their reentrant circuits.Results: Baseline patient characteristics, use of antiarrhythmic drugs, prevalence of atrial fibrillation, AFL cycle length (227.1 ± 21.4 vs. 245.5 ± 36.0 ms, p = .10), and CTI length (31.9 ± 8.3 vs. 31.1 ± 5.2 mm, p = .80) did not differ between the two groups. Functional block was observed at the crista terminalis in 16 patients and at the sinus venosus in 11. No functional block was observed in three patients, all of whom belonged to the rt‐AFL group. That is, functional block was observed in 100% of the t‐AFL group as opposed to 5/8 (62.5%) of the rt‐AFL (p < .05). Slow conduction zones were frequently observed at the intra‐atrial septum in the t‐AFL group and at the CTI in the rt‐AFL group.Conclusion: Mapping with ultrahigh‐resolution mapping showed differences between t‐AFL and rt‐AFL in conduction properties in the right atrium and around the tricuspid valve, which suggested directional mechanisms.


  • Open Access

    Peri-procedural anticoagulation in patients with end-stage kidney disease undergoing atrial fibrillation ablation: results from the multicentre end-stage kidney disease–atrial fibrillation ablation registry

    by Tasuku Yamamoto, Shinsuke Miyazaki, Yasuaki Tanaka, Toshikazu Kono, Tadanori Nakata, Akira Mizukami, Daisetsu Aoyama, Hirofumi Arai, Yuta Taomoto, Tomoki Horie, et al.

    The optimal anticoagulation regimen in patients with end-stage kidney disease (ESKD) undergoing atrial fibrillation (AF) catheter ablation is unknown. We sought to describe the real-world practice of peri-procedural anticoagulation management in patients with ESKD undergoing AF ablation. Patients with ESKD on haemodialysis undergoing catheter ablation for AF in 12 referral centres in Japan were included. The international normalized ratio (INR) before and 1 and 3 months after ablation was collected. Peri-procedural major haemorrhagic events as defined by the International Society on Thrombosis and Haemostasis, as well as thromboembolic events, were adjudicated. A total of 347 procedures in 307 patients (67 ±9 years, 40% female) were included. Overall, INR values were grossly subtherapeutic [1.58 (interquartile range: 1.20–2.00) before ablation, 1.54 (1.22–2.02) at 1 month, and 1.22 (1.01–1.71) at 3 months]. Thirty-five patients (10%) suffered major complications, the majority of which was major bleeding (19 patients; 5.4%), including 11 cardiac tamponade (3.2%). There were two peri-procedural deaths (0.6%), both related to bleeding events. A pre-procedural INR value of 2.0 or higher was the only independent predictor of major bleeding [odds ratio, 3.3 (1.2–8.7), P = 0.018]. No cerebral or systemic thromboembolism occurred. Despite most patients with ESKD undergoing AF ablation showing undertreatment with warfarin, major bleeding events are common while thromboembolic events are rare.