INImad Noureldin

Imad Noureldin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Imad Noureldin has a total of 2 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Construction of a Zinc Oxide Nanorod-Modified Coated Wire Electrode for Potentiometric Determination of Levocetirizine Dihydrochloride in Its Pure and Combined Form

    by Dania Nashed, Imad Noureldin, Amir Alhaj Sakur

    Coated Wire Electrodes are considered the most effective and selective type of ion selective electrodes because of the modified surface with different materials according to the substance to be analyzed. This study aims to construct the first potentiometric method for analysis of Levocetirizine (LVZ) in its combination form with Montelukast drug. A novel potentiometric sensor which consists of a silver wire coated with Zinc Oxide (ZnO) nanorod modified with a polymeric membrane combining β-Cyclodextrin and tetraphenyl borate, plasticized with di-butyl phthalate was constructed for the determination of Levocetirizine.2HCl in its pure form and its combination dosage form. The fabricated sensor exhibited a linearity range (5x10 −6- 1x10−2) mol/L with a Nernstian slope 57.88 mV/decade, over pH range (2–4.5), the effect of the temperature on the constructed sensor was studied and it was found that the electrode works effectively over (10–50) C°. The electrode showed a fast response time and the lifetime of the electrode was found to be 72 days without significant change in the Nernstian slope value. The selectivity of the electrode toward levocetirizine was estimated in the presence of some obstructive ions. The method was validated according to ICH rules and applied to the determination of levocetirizine in its pure and combined pharmaceutical dosage forms. This paper introduces the synthesis of the first modified Coated Wire Electrode with ZnO Nanorods for determination the Levocetirizine drug. The obtained results demonstrate the ability of the electrochemical methods to analyze drugs in their combination. The presented method excels over another analytical methods in terms of sensitivity, selectivity and simplicity.


  • Open Access

    Selective Consecutive Determination of Desloratadine and Montelukast Sodium in Their Pure and Binary Dosage Form Based on Pencil Graphite Electrochemical Sensors

    by Amir Alhaj Sakur, Dania Nashed, Imad Noureldin

    In this study, we present a new, green electrochemical method for potentiometric estimation of desloratadine and montelukast sodium in their pure and binary dosage form. For that, three pencil graphite sensors were fabricated; the first one was prepared to analyse desloratadine drug (DES) by coating the graphite bar with the coating membrane, which comprises the ion pair of desloratadine and ammonium reineckate reagent (RNK), the polymer poly vinyl chloride (PVC), and the plasticizers dibutyl phthalate (DBP). The second one, which was used to analyse montelukast (MON), was constructed by using the ion pair of cadmium chloride reagent (Cd.) with montelukast and the same earlier named polymer and plasticizer. As a trial to analyse both of the drugs by the same sensor consecutively, we have constructed a combined pencil graphite electrode, which contains the two earlier suggested ion pairs, that is, we can use this electrode to selectively analyse for each drug. The proposed electrodes were effectively used for analysis of DES and MON as a single dosage form and as combined pharmaceutical preparation, without any need for prior separation that was performed depending on the difference in the efficient pH range for each sensor. The proposed sensors exhibited a Nernstian equation slopes of 30.11, 27.70, (29.16, 29.79)mv. decade−1 in the linearity range 5.00×10−51.00×10−2 and 1.00×10−51.00×10−2M, respectively. The sensors exhibit high sensitivity according to LOD values ((0.0360.018)(0.025-0.026)µM), respectively, and important selectivity toward the studied drugs in presence of interfering ions and excipients. The optimum circumstances were studied, and the method was validated by application of ICH rules. Finally, the method was compared with a documented method, and the required statistical values were calculated.


  • Open Access

    New pencil graphite electrodes for potentiometric determination of fexofenadine hydrochloride and montelukast sodium in their pure, synthetic mixtures, and combined dosage form

    by Dania Nashed, Imad Noureldin, Amir Alhaj Sakur

    This paper introduces the first electrochemical approach for the determination of Fexofenadine hydrochloride and Montelukast sodium as a combined form by constructing three new graphite electrodes coated with a polymeric membrane. The first electrode was constructed using ammonium molybdate reagent as an ion pair with fexofenadine cation for the determination of Fexofenadine drug, the second electrode was constructed using cobalt nitrate as an ion pair with montelukast anion for the determination of Montelukast drug, the third electrode was prepared by incorporating the two previously mentioned ion pairs in the same graphite sensor, which makes this sensor sensitive to each Fexofenadine and Montelukast drug. The coating material was a polymeric film comprises of Poly Vinyl Chloride (PVC), Di-butyl phthalate as a plasticizer (DBP), ion pairs of drugs with previously mentioned reagents. The electrodes showed a Nernstian response with a mean calibration graph slopes of [59.227, 28.430, (59.048, 28,643)] mv.decade−1 for the three pencil electrodes respectively, with detection limits 0.025 μM for Fexofenadine and 0.019 μM for Montelukast drug which makes this method outperforms the reported method for the determination of this combination. The electrodes work effectively over pH range (2–4.5) for Fexofenadine hydrochloride and (5–9.5) for Montelukast sodium. The influence of the proposed interfering species was negligible as shown by selectivity coefficient values. The effectiveness of the electrodes continued in a period of time (45–69) days. The suggested sensors demonstrated useful analytical features for the determination of both drugs in bulk powder, in laboratory prepared mixtures and their combined dosage form. We have validated the method following ICH protocol, and we have reached very significant results in terms of the linearity, accuracy, selectivity, and precision of the method.