Paul Ritsche
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paul Ritsche has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Oliver Faude
Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
13 shared publications - Martino Vladimiro Franchi
Department of Biomedical Sciences University of Padova Padova Italy
7 shared publications Oliver Faude
Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
6 shared publications- Fabio Sarto
Department of Biomedical Sciences, University of Padova, Padova, Italy
5 shared publications - Martin Keller
Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland
5 shared publications - Neil J. Cronin
Faculty of Sport and Health Sciences University of Jyväskylä Jyväskylä Finland
5 shared publications
Latest Publications
- Open Access
- 22 April 2026
- Published by University of Ottawa Library
Relationship of Quadriceps Geometry and Strength in Male and Female national-level Soccer Players
Quadriceps muscles are essential for various aspects soccer performance. This study explored the relationships between quadriceps muscle architecture, morphology, and strength in male and female national-level soccer players. The regional architecture and morphology of the rectus femoris (RF) and vastus lateralis (VL) muscles were examined using ultrasonography, whereas knee extension strength was assessed via isometric and isokinetic dynamometry at 60°/s and 240°/s. Participants included 25 female (age: 22.3±4.1 years; height: 169.9±5.0 cm; weight: 62.6±5.6 kg; muscle mass: 28.0±2.3 kg) and 55 male (age: 18.8±1.2 years; height: 177.16±7.1 cm; weight: 70.7±8.1 kg; muscle mass: 36.3±4.3 kg) tier 3 national-level soccer players. Males showed greater muscle cross-sectional areas (ACSA) and knee extension strength than females. Notably, relationships between ACSA and knee extension strength primarily differed between males and females during fast isokinetic contractions. Moderate correlations were consistent between isokinetic torque and VL ACSA at 33% femur length (r=0.41–0.61) in females. Muscle architectural parameters showed no differences between males and females or associations with strength, and weight adjustments attenuated most correlations. These results indicate differences in quadriceps morphology and strength in male and female soccer players, while muscle architecture remains similar across sexes.
- 22 April 2026
- Published by University of Ottawa Library
Open AccessRelationship of Quadriceps Geometry and Strength in Male and Female national-level Soccer Players
Quadriceps muscles are essential for various aspects soccer performance. This study explored the relationships between quadriceps muscle architecture, morphology, and strength in male and female national-level soccer players. The regional architecture and morphology of the rectus femoris (RF) and vastus lateralis (VL) muscles were examined using ultrasonography, whereas knee extension strength was assessed via isometric and isokinetic dynamometry at 60°/s and 240°/s. Participants included 25 female (age: 22.3±4.1 years; height: 169.9±5.0 cm; weight: 62.6±5.6 kg; muscle mass: 28.0±2.3 kg) and 55 male (age: 18.8±1.2 years; height: 177.16±7.1 cm; weight: 70.7±8.1 kg; muscle mass: 36.3±4.3 kg) tier 3 national-level soccer players. Males showed greater muscle cross-sectional areas (ACSA) and knee extension strength than females. Notably, relationships between ACSA and knee extension strength primarily differed between males and females during fast isokinetic contractions. Moderate correlations were consistent between isokinetic torque and VL ACSA at 33% femur length (r=0.41–0.61) in females. Muscle architectural parameters showed no differences between males and females or associations with strength, and weight adjustments attenuated most correlations. These results indicate differences in quadriceps morphology and strength in male and female soccer players, while muscle architecture remains similar across sexes.
- Open Access
- 20 February 2026
- Published by Oxford University Press (OUP) in JBMR Plus
- Vol. 10 (4) , ziag025
Open and reproducible research in musculoskeletal imaging: Why it matters and how to implement it with the guidelines of the ORMIR community
The Open and Reproducible Musculoskeletal Imaging Research (ORMIR) community is a scientific community dedicated to promoting openness and reproducibility in musculoskeletal imaging, image processing, and computational modelling. In this perspective paper, we outline the motivations for conducting transparent research and provide practical guidelines to implement it. We start with defining open and reproducible research and describing the benefits and challenges of working transparently. Next, we redefine the outputs of a computational research study as—ideally—a combination of data, code, and a publication, recommend a folder and file structure that reflects these three study outcomes, and describe how to maintain and update such a structure during the study and at study publication. Finally, we emphasize that working in an open and reproducible manner is a learning process and the best way to acquire the necessary competencies is simply to start. Lay summary: The ORMIR community promotes openness and reproducibility in musculoskeletal imaging research. In this perspective paper, we explain why transparency matters and recommend how to conduct a computational study in an open and reproducible manner focusing on its three outputs: data, code, and publication. Finally, we highlight that the best way to learn these practices is simply to start.
- 20 February 2026
- Published by Oxford University Press (OUP) in JBMR Plus
- Vol. 10 (4) , ziag025
Open AccessOpen and reproducible research in musculoskeletal imaging: Why it matters and how to implement it with the guidelines of the ORMIR community
The Open and Reproducible Musculoskeletal Imaging Research (ORMIR) community is a scientific community dedicated to promoting openness and reproducibility in musculoskeletal imaging, image processing, and computational modelling. In this perspective paper, we outline the motivations for conducting transparent research and provide practical guidelines to implement it. We start with defining open and reproducible research and describing the benefits and challenges of working transparently. Next, we redefine the outputs of a computational research study as—ideally—a combination of data, code, and a publication, recommend a folder and file structure that reflects these three study outcomes, and describe how to maintain and update such a structure during the study and at study publication. Finally, we emphasize that working in an open and reproducible manner is a learning process and the best way to acquire the necessary competencies is simply to start. Lay summary: The ORMIR community promotes openness and reproducibility in musculoskeletal imaging research. In this perspective paper, we explain why transparency matters and recommend how to conduct a computational study in an open and reproducible manner focusing on its three outputs: data, code, and publication. Finally, we highlight that the best way to learn these practices is simply to start.
- Open Access
- 17 February 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (2) , 056
Symposium 8.3 - From Principles to Practice: Building a Reproducible Future for Movement Sciences
Open science is transforming biomedical sciences by fostering transparency, reproducibility, and data reuse across laboratories and disciplines. Yet, despite broad consensus on its importance, the community still lacks the infrastructures, standards, and practical guidance needed to make openness routine. This symposium presents three initiatives that address this gap, from identifying community needs to implementing sustainable solutions. The first presentation (Ariana Ortigas-Vásquez) summarises results from the Internation Society of Biomechanics 2025 data-sharing survey, revealing strong motivation for openness but persistent barriers related to metadata standards, legal uncertainty, and methodological inconsistency. These findings define the community’s urgent priorities. Building on this evidence, the second talk (Michelle Haas) introduces the MoveD guidelines, an empirically grounded framework for FAIR-compliant data sharing in Swiss movement laboratories. MoveD was developed through nationwide surveys and expert workshops to translate open-science ideals into feasible laboratory practice. The final presentation (Paul Ritsche) demonstrates how such frameworks can be realised in imaging research through the ORMIR and UMUD initiatives, which establish interoperable standards for musculoskeletal imaging and open ultrasonography databases. Together, these talks show a coherent path from community insights to actionable infrastructures by illustrating how shared standards can strengthen reproducible, integrative research in sport and health.
- 17 February 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (2) , 056
Open AccessSymposium 8.3 - From Principles to Practice: Building a Reproducible Future for Movement Sciences
Open science is transforming biomedical sciences by fostering transparency, reproducibility, and data reuse across laboratories and disciplines. Yet, despite broad consensus on its importance, the community still lacks the infrastructures, standards, and practical guidance needed to make openness routine. This symposium presents three initiatives that address this gap, from identifying community needs to implementing sustainable solutions. The first presentation (Ariana Ortigas-Vásquez) summarises results from the Internation Society of Biomechanics 2025 data-sharing survey, revealing strong motivation for openness but persistent barriers related to metadata standards, legal uncertainty, and methodological inconsistency. These findings define the community’s urgent priorities. Building on this evidence, the second talk (Michelle Haas) introduces the MoveD guidelines, an empirically grounded framework for FAIR-compliant data sharing in Swiss movement laboratories. MoveD was developed through nationwide surveys and expert workshops to translate open-science ideals into feasible laboratory practice. The final presentation (Paul Ritsche) demonstrates how such frameworks can be realised in imaging research through the ORMIR and UMUD initiatives, which establish interoperable standards for musculoskeletal imaging and open ultrasonography databases. Together, these talks show a coherent path from community insights to actionable infrastructures by illustrating how shared standards can strengthen reproducible, integrative research in sport and health.
- Open Access
- 17 February 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (2) , 032
Ultrasonography-Based Patellar Tendon Area Measurement: Comparability of Automated vs. Manual Segmentation
Introduction & Purpose: The patellar tendon shows region-specific structural adaptations to loading and aging, making accurate assessment of its anatomical cross sectional area (ACSA) clinically relevant (Ito et al., 2023). Ultrasound offers a practical alternative to MRI, but manual analysis is time-consuming and operator-dependent, motivating automated solutions. While several openly available tools for the automatic segmentation of the anatomical cross-sectional area of muscle exist, there is no open-source and peer-reviewed tool for the patellar tendon. In this study, we tested a fully automatic approach for the segmentation of the patellar tendon ACSA in panoramic and non-panoramic ultrasound images. Methods: Images were acquired at 25%, 50%, and 75% of the length of the patellar tendon from 30 participants (age: 46.87±6.03 years; BMI: 25.45±4.14 kg/m²). To assess measurement consistency, we evaluated intra-rater and inter-session reliability using manual segmentation of the ACSA (Ritsche et al., 2022). Additionally, we trained three neural networks with a dataset of 497 images (156 panoramic images) to compare the performance of manual segmentation with automatic segmentation on a test set of unseen images. Results: Intra-rater reliability was found to be good with ICC of 0.804 (95% CI: 0.628-0.902), SEM equal to 0.05 cm² (0.03-0.07), and MAE of 0.05 cm² (0.04-0.07); while inter-session reliability was excellent with ICC of 0.980 (0.970-0.987), SEM equal to 0.02 cm² (0.02-0.02), and MAE of 0.02 cm² (0.01-0.02). Regarding the comparability of the best model (i.e., UNet3+) after the removal of erroneous predictions with manual analysis, the ICC was equal to 0.848 (0.702-0.914), SEM was 0.05 (0.04-0.07), and MAE was 0.05 cm² (0.05-0.06) with a small standardized mean difference of 0.53 (0.33-0.75). When applying the model, analysis times per image ranged between 0.302 and 0.414 s. Discussion: Both intra-rater and inter-session analyses demonstrated good to excellent reliability for assessing patellar tendon ACSA, confirming the repeatability of manual segmentation. Intra-rater reliability was slightly lower than in muscle ACSA studies, likely due to the tendon’s smaller size, where minor inaccuracies have a larger relative impact. Still, error margins were sufficient to detect known sex-related differences, though potentially insufficient for subtle age-related changes (Carroll et al., 2008). Inter-session reliability was excellent and consistent with existing literature, likely aided by standardized acquisition and reference images. The UNet3+ model slightly underestimated ACSA, and removing erroneous predictions only modestly improved agreement, emphasizing that visually subtle segmentation errors may escape detection yet remain physiologically meaningful. Model performance was particularly dependent on image quality and tendon boundary visibility. Overall, these findings support the feasibility of automated ACSA segmentation, with UNet3+ providing the most stable performance and substantial time savings, though expert oversight remains essential and further validation across devices, operators, and longitudinal designs is needed. Conclusion: The proposed approach enables fast and less operator-dependent patellar tendon ACSA analysis. Although some differences were observed between manual and automatic analysis, this tool, when applied with caution, could provide valuable support in both clinical and research settings. References Carroll, C. C., Dickinson, J. M., Haus, J. M., Lee, G. A., Hollon, C. J., Aagaard, P., Magnusson, S. P., & Trappe, T. A. (2008). Influence of aging on the in vivo properties of human patellar tendon. Journal of Applied Physiology (Bethesda, Md.: 1985), 105(6), Article 6. https://doi.org/10.1152/japplphysiol.00059.2008 Ito, N., Scattone Silva, R., Sigurðsson, H. B., Cortes, D. H., & Silbernagel, K. G. (2023). Challenging the assumption of uniformity in patellar tendon structure: Regional patellar tendon morphology and mechanical properties in vivo. Journal of Orthopaedic Research: Official Publication of the Orthopaedic Research Society, 41(10), Article 10. https://doi.org/10.1002/jor.25563 Ritsche, P., Wirth, P., Cronin, N. J., Sarto, F., Narici, M. V., Faude, O., & Franchi, M. V. (2022). DeepACSA: Automatic Segmentation of Cross-Sectional Area in Ultrasound Images of Lower Limb Muscles Using Deep Learning. Medicine and Science in Sports and Exercise, 54(12), Article 12. https://doi.org/10.1249/MSS.0000000000003010
- 17 February 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (2) , 032
Open AccessUltrasonography-Based Patellar Tendon Area Measurement: Comparability of Automated vs. Manual Segmentation
Introduction & Purpose: The patellar tendon shows region-specific structural adaptations to loading and aging, making accurate assessment of its anatomical cross sectional area (ACSA) clinically relevant (Ito et al., 2023). Ultrasound offers a practical alternative to MRI, but manual analysis is time-consuming and operator-dependent, motivating automated solutions. While several openly available tools for the automatic segmentation of the anatomical cross-sectional area of muscle exist, there is no open-source and peer-reviewed tool for the patellar tendon. In this study, we tested a fully automatic approach for the segmentation of the patellar tendon ACSA in panoramic and non-panoramic ultrasound images. Methods: Images were acquired at 25%, 50%, and 75% of the length of the patellar tendon from 30 participants (age: 46.87±6.03 years; BMI: 25.45±4.14 kg/m²). To assess measurement consistency, we evaluated intra-rater and inter-session reliability using manual segmentation of the ACSA (Ritsche et al., 2022). Additionally, we trained three neural networks with a dataset of 497 images (156 panoramic images) to compare the performance of manual segmentation with automatic segmentation on a test set of unseen images. Results: Intra-rater reliability was found to be good with ICC of 0.804 (95% CI: 0.628-0.902), SEM equal to 0.05 cm² (0.03-0.07), and MAE of 0.05 cm² (0.04-0.07); while inter-session reliability was excellent with ICC of 0.980 (0.970-0.987), SEM equal to 0.02 cm² (0.02-0.02), and MAE of 0.02 cm² (0.01-0.02). Regarding the comparability of the best model (i.e., UNet3+) after the removal of erroneous predictions with manual analysis, the ICC was equal to 0.848 (0.702-0.914), SEM was 0.05 (0.04-0.07), and MAE was 0.05 cm² (0.05-0.06) with a small standardized mean difference of 0.53 (0.33-0.75). When applying the model, analysis times per image ranged between 0.302 and 0.414 s. Discussion: Both intra-rater and inter-session analyses demonstrated good to excellent reliability for assessing patellar tendon ACSA, confirming the repeatability of manual segmentation. Intra-rater reliability was slightly lower than in muscle ACSA studies, likely due to the tendon’s smaller size, where minor inaccuracies have a larger relative impact. Still, error margins were sufficient to detect known sex-related differences, though potentially insufficient for subtle age-related changes (Carroll et al., 2008). Inter-session reliability was excellent and consistent with existing literature, likely aided by standardized acquisition and reference images. The UNet3+ model slightly underestimated ACSA, and removing erroneous predictions only modestly improved agreement, emphasizing that visually subtle segmentation errors may escape detection yet remain physiologically meaningful. Model performance was particularly dependent on image quality and tendon boundary visibility. Overall, these findings support the feasibility of automated ACSA segmentation, with UNet3+ providing the most stable performance and substantial time savings, though expert oversight remains essential and further validation across devices, operators, and longitudinal designs is needed. Conclusion: The proposed approach enables fast and less operator-dependent patellar tendon ACSA analysis. Although some differences were observed between manual and automatic analysis, this tool, when applied with caution, could provide valuable support in both clinical and research settings. References Carroll, C. C., Dickinson, J. M., Haus, J. M., Lee, G. A., Hollon, C. J., Aagaard, P., Magnusson, S. P., & Trappe, T. A. (2008). Influence of aging on the in vivo properties of human patellar tendon. Journal of Applied Physiology (Bethesda, Md.: 1985), 105(6), Article 6. https://doi.org/10.1152/japplphysiol.00059.2008 Ito, N., Scattone Silva, R., Sigurðsson, H. B., Cortes, D. H., & Silbernagel, K. G. (2023). Challenging the assumption of uniformity in patellar tendon structure: Regional patellar tendon morphology and mechanical properties in vivo. Journal of Orthopaedic Research: Official Publication of the Orthopaedic Research Society, 41(10), Article 10. https://doi.org/10.1002/jor.25563 Ritsche, P., Wirth, P., Cronin, N. J., Sarto, F., Narici, M. V., Faude, O., & Franchi, M. V. (2022). DeepACSA: Automatic Segmentation of Cross-Sectional Area in Ultrasound Images of Lower Limb Muscles Using Deep Learning. Medicine and Science in Sports and Exercise, 54(12), Article 12. https://doi.org/10.1249/MSS.0000000000003010
- Open Access
- 17 February 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (2) , 022
deepPatella: A Tool for Automatic Tracking of Patella Tendon Elongation and Stiffness Calculation
Patellar tendon (PT) stiffness is highly load-sensitive and can decrease by up to 29% after 14 days of unloading, impacting force transfer and thereby rehabilitation processes and athletic performance. While automated ultrasound (US) analysis has been applied to the Achilles tendon, PT elongation—an indirect marker of stiffness—still relies on manual and time-consuming frame-by-frame annotation. We present deepPatella, a novel, automated, transformer-based, open-source software with Kalman (KF) filtering to efficiently (and objectively) track PT elongation from US frame sequences. PT elongation was assessed using US (ArtUS, Telemed) with a 6 cm linear probe (LF9-5N60-A3 @7 MHz) fixed over the PT apex and tibial tuberosity during ramped isometric knee extensions. US images were recorded at 50 fps. Elongation was defined as relative displacement of proximal and distal insertions, manually labelled by two raters. The dataset included 17.475 frames from 30 participants (13 males, age=46.5 years (35-56), weight=73.7 kg (53.1-95.1), height=171.3 cm (158.0-188.0)), split into 12.221/5.254 frames (or 27/14 videos) for training/testing. A TransUNet model with sigmoid-based heatmaps, BCE-Dice loss, and ADAM optimizer predicted insertion points; predictions were subsequently smoothed using a Kalman filter. Accuracy was evaluated via Euclidean distance to manual labels and by comparing predicted and Kalman filtered PT elongation against the manually labelled one. In the 14 test videos, PT elongation was 4.8±1.5 mm based on manual annotation, 4.6±2.8 mm from the model prediction, and 4.6 ±2.9 mm with KF. Mean Euclidean errors compared to manual labels were 0.9±0.5 mm for the distal and 1.0±0.4 mm for the proximal insertions, for both model and Kalman. Accordingly, total absolute elongation Euclidean errors were 1.0±0.9 mm for the model and 1.0±1.8 mm for Kalman. Overall, the model predicted PT insertions with high accuracy and KF smoothed but did not improve the predictions. Additionally, using deepPatella, the processing time of per test video was reduced by 90% from 30 minutes (manual labelling) to 3 minutes. Thus, deepPatella enables time-efficient and objective PT elongation analysis in US videos and provides the basis for automated stiffness estimation. The openly available deepPatella software further enables users to compute tendon elongation and stiffness on their own data.
- 17 February 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (2) , 022
Open AccessdeepPatella: A Tool for Automatic Tracking of Patella Tendon Elongation and Stiffness Calculation
Patellar tendon (PT) stiffness is highly load-sensitive and can decrease by up to 29% after 14 days of unloading, impacting force transfer and thereby rehabilitation processes and athletic performance. While automated ultrasound (US) analysis has been applied to the Achilles tendon, PT elongation—an indirect marker of stiffness—still relies on manual and time-consuming frame-by-frame annotation. We present deepPatella, a novel, automated, transformer-based, open-source software with Kalman (KF) filtering to efficiently (and objectively) track PT elongation from US frame sequences. PT elongation was assessed using US (ArtUS, Telemed) with a 6 cm linear probe (LF9-5N60-A3 @7 MHz) fixed over the PT apex and tibial tuberosity during ramped isometric knee extensions. US images were recorded at 50 fps. Elongation was defined as relative displacement of proximal and distal insertions, manually labelled by two raters. The dataset included 17.475 frames from 30 participants (13 males, age=46.5 years (35-56), weight=73.7 kg (53.1-95.1), height=171.3 cm (158.0-188.0)), split into 12.221/5.254 frames (or 27/14 videos) for training/testing. A TransUNet model with sigmoid-based heatmaps, BCE-Dice loss, and ADAM optimizer predicted insertion points; predictions were subsequently smoothed using a Kalman filter. Accuracy was evaluated via Euclidean distance to manual labels and by comparing predicted and Kalman filtered PT elongation against the manually labelled one. In the 14 test videos, PT elongation was 4.8±1.5 mm based on manual annotation, 4.6±2.8 mm from the model prediction, and 4.6 ±2.9 mm with KF. Mean Euclidean errors compared to manual labels were 0.9±0.5 mm for the distal and 1.0±0.4 mm for the proximal insertions, for both model and Kalman. Accordingly, total absolute elongation Euclidean errors were 1.0±0.9 mm for the model and 1.0±1.8 mm for Kalman. Overall, the model predicted PT insertions with high accuracy and KF smoothed but did not improve the predictions. Additionally, using deepPatella, the processing time of per test video was reduced by 90% from 30 minutes (manual labelling) to 3 minutes. Thus, deepPatella enables time-efficient and objective PT elongation analysis in US videos and provides the basis for automated stiffness estimation. The openly available deepPatella software further enables users to compute tendon elongation and stiffness on their own data.
- Open Access
- 17 February 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (2) , 021
UMUD: A Web Application for Easy Access to Musculoskeletal Ultrasonography Datasets
Introduction & Purpose: Ultrasonography is widely used to assess skeletal muscle and tendon properties, such as architecture, cross-sectional area, and tissue stiffness (Sarto et al., 2021). Despite its growing application in different scenarios, and the increasing call for open data access and sharing in clinical research, there remains a significant scarcity of public datasets in this field. This lack of accessible and standardized public datasets limits large-scale analysis algorithm studies, trainee training and the development of image analysis algorithms. To address this, we developed the Universal Musculoskeletal Ultrasonography Database (UMUD), a web application designed to facilitate access to these datasets and foster standardization and innovation in musculoskeletal ultrasonography imaging research. Methods: UMUD is an online repository that aggregates and indexes metadata from publicly available musculoskeletal ultrasonography datasets hosted on platforms like the Open Science Framework and Zenodo. The web application (https://universalmuscledatabase.streamlit.app/) is built using a streamlit (v1.35.0) frontend and mongoDB for its database infrastructure. Standardized metadata descriptors, i.e., muscle group, ultrasound device, participant demographics, are implemented using a combination of pydantic models (v1.10.0) and json schemata to ensure reproducibility and ease of usage for contributing data. UMUD provides detailed instructions for community contributions, including tools for data anonymization. Results: Currently, UMUD hosts 11 datasets from 10 studies, comprising 75,569 images and 2,573 videos from 1,769 participants. The database covers nine lower-limb muscles and one muscle–tendon junction (distal triceps surae and Achilles tendon), captured using various modalities including static imaging, dynamic video, and 3D reconstructions. Datasets include measurements across proximal, middle, and distal regions of each muscle. Benchmark datasets are provided for trainee training and algorithm evaluation, including multi-expert annotated images, fascicle and cross-sectional area overlays, and fully labeled datasets for deep-learning model training. Additionally, UMUD lists available automated image analysis algorithms as a reference for community use. Discussion: UMUD provides an initial foundation for open, standardized, and community-driven musculoskeletal ultrasound research. By centralizing datasets and metadata, it facilitates reproducible research, algorithm benchmarking, and operator education. The inclusion of multi-expert and labeled benchmark datasets supports both training and the development of automated analysis methods. Future directions include expanding dataset coverage, enhancing interactive visualization tools, and launching community challenges for algorithm benchmarking to accelerate innovation in the field. Conclusions: In conclusion, UMUD addresses relevant challenges in musculoskeletal ultrasonography by providing a centralized, standardized repository of datasets and tools. It promotes transparency and innovation in the field, supporting reproducible research and advancements in automated image analysis. Future developments include adding datasets, expanding functionalities and introducing community-driven algorithm development challenges. References Sarto, F., Spörri, J., Fitze, D. P., Quinlan, J. I., Narici, M. V., & Franchi, M. V. (2021). Implementing Ultrasound Imaging for the Assessment of Muscle and Tendon Properties in Elite Sports: Practical Aspects, Methodological Considerations and Future Directions. Sports Med, 51(6), 1151–1170. https://doi.org/10.1007/s40279-021-01436-7
- 17 February 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (2) , 021
Open AccessUMUD: A Web Application for Easy Access to Musculoskeletal Ultrasonography Datasets
Introduction & Purpose: Ultrasonography is widely used to assess skeletal muscle and tendon properties, such as architecture, cross-sectional area, and tissue stiffness (Sarto et al., 2021). Despite its growing application in different scenarios, and the increasing call for open data access and sharing in clinical research, there remains a significant scarcity of public datasets in this field. This lack of accessible and standardized public datasets limits large-scale analysis algorithm studies, trainee training and the development of image analysis algorithms. To address this, we developed the Universal Musculoskeletal Ultrasonography Database (UMUD), a web application designed to facilitate access to these datasets and foster standardization and innovation in musculoskeletal ultrasonography imaging research. Methods: UMUD is an online repository that aggregates and indexes metadata from publicly available musculoskeletal ultrasonography datasets hosted on platforms like the Open Science Framework and Zenodo. The web application (https://universalmuscledatabase.streamlit.app/) is built using a streamlit (v1.35.0) frontend and mongoDB for its database infrastructure. Standardized metadata descriptors, i.e., muscle group, ultrasound device, participant demographics, are implemented using a combination of pydantic models (v1.10.0) and json schemata to ensure reproducibility and ease of usage for contributing data. UMUD provides detailed instructions for community contributions, including tools for data anonymization. Results: Currently, UMUD hosts 11 datasets from 10 studies, comprising 75,569 images and 2,573 videos from 1,769 participants. The database covers nine lower-limb muscles and one muscle–tendon junction (distal triceps surae and Achilles tendon), captured using various modalities including static imaging, dynamic video, and 3D reconstructions. Datasets include measurements across proximal, middle, and distal regions of each muscle. Benchmark datasets are provided for trainee training and algorithm evaluation, including multi-expert annotated images, fascicle and cross-sectional area overlays, and fully labeled datasets for deep-learning model training. Additionally, UMUD lists available automated image analysis algorithms as a reference for community use. Discussion: UMUD provides an initial foundation for open, standardized, and community-driven musculoskeletal ultrasound research. By centralizing datasets and metadata, it facilitates reproducible research, algorithm benchmarking, and operator education. The inclusion of multi-expert and labeled benchmark datasets supports both training and the development of automated analysis methods. Future directions include expanding dataset coverage, enhancing interactive visualization tools, and launching community challenges for algorithm benchmarking to accelerate innovation in the field. Conclusions: In conclusion, UMUD addresses relevant challenges in musculoskeletal ultrasonography by providing a centralized, standardized repository of datasets and tools. It promotes transparency and innovation in the field, supporting reproducible research and advancements in automated image analysis. Future developments include adding datasets, expanding functionalities and introducing community-driven algorithm development challenges. References Sarto, F., Spörri, J., Fitze, D. P., Quinlan, J. I., Narici, M. V., & Franchi, M. V. (2021). Implementing Ultrasound Imaging for the Assessment of Muscle and Tendon Properties in Elite Sports: Practical Aspects, Methodological Considerations and Future Directions. Sports Med, 51(6), 1151–1170. https://doi.org/10.1007/s40279-021-01436-7
- Open Access
- 17 February 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (2) , 059
Implementing Open and Standardized Data Practices in Musculoskeletal Imaging: ORMIR and UMUD
Due to the increasing amount of research data, open and reproducible data practices will define the future of medical research. Despite strong conceptual frameworks such as FAIR (Findable, Accessible, Interoperable, Reusable), implementation across laboratories remains inconsistent and fragmented. The MoveD (Haas et al., 2024) initiative outlines open, FAIR, and reproducible data practices in human movement research. However, putting such frameworks into operation remains challenging, especially in imaging-based disciplines, where data are heterogeneous and often under proprietary ecosystems. The Open and Reproducible Musculoskeletal Imaging Research (ORMIR) community and the Universal Musculoskeletal Ultrasonography Database (UMUD) address this issue by implementing reproducible data sharing in musculoskeletal imaging (Bonaretti et al., 2025; Ritsche et al., 2025). Here, we demonstrate implementation of guideline-based, reproducible data practices showcasing the ORMIR Medical Imaging Data Structure (MIDS) and UMUD. One of ORMIR’s aims is to create technical standards for organizing and sharing musculoskeletal imaging data across modalities and disciplines such as MRI, CT, and ultrasound. ORMIR-MIDS defines a transparent folder hierarchy, file-naming conventions, and a metadata scheme that ensure imaging datasets are both human-readable and machine-interpretable. A publicly available Python implementation enables validation, anonymization, and bidirectional conversion between ORMIR-MIDS and common vendor formats, lowering the technical barriers to adoption. Importantly, ORMIR-MIDS is not only a data structure but also a mechanism for community convergence—encouraging laboratories to align their workflows with shared standards that support cross-study comparability, reproducibility, and long-term reusability. UMUD offers an example of how such standards can be applied in ultrasonography research. It provides an openly available webapp that indexes metadata from publicly available musculoskeletal ultrasound datasets hosted on open platforms such as Zenodo. Using a standardized metadata scheme derived from ORMIR and MoveD principles, UMUD enhances the discoverability and comparability of datasets, linking them through descriptors based on expert consensus. By providing contribution and data structuring instructions, UMUD allows the research community to easily contribute their data. UMUD demonstrates how open research data can actively support both methodological innovation and capacity building in the research community. Together, ORMIR and UMUD embody the transition from conceptual to actionable open science. They illustrate how principles articulated in MoveD and FAIR can be realized through interoperable standards, shared infrastructure, and collaboration between technical and applied domains. References Bonaretti, S., Barzegari, M., Bevers, M., Boyd, S., Burghardt, A. J., Cameron, D., Chiumento, F., Crimi, G., Degenhart, G., Durongbhan, P., Hernandez, M. A. E., Fraterrigo, G., Ghasem-Zadeh, A., Grassi, L., Hirvasniemi, J., Hosseinitabatabaei, M., Iori, G., Kok, J., Kuczynski, M., … Zukic, D. (2025). Open and reproducible research in musculoskeletal imaging: Why it matters and how to implement it with the guidelines of the ORMIR community. https://doi.org/10.5281/zenodo.17258830 Haas, M. C., Sommer, B. B., Van Rekum, S., Moerman, F., & Graf, E. S. (2024, November). MoveD - open research data guidelines for movement laboratories. Zenodo. https://doi.org/10.5281/zenodo.14179954 Ritsche, P., Sarto, F., Santini, F., Leitner, C., Franchi, M., Faude, O., Finni, T., Seynnes, O., & Cronin, N. (2025). UMUD: A Web Application for Easy Access to Musculoskeletal Ultrasonography Datasets. Open Science Framework. https://doi.org/10.31219/osf.io/syr4z
- 17 February 2026
- Published by University of Bern in Current Issues in Sport Science (CISS)
- Vol. 11 (2) , 059
Open AccessImplementing Open and Standardized Data Practices in Musculoskeletal Imaging: ORMIR and UMUD
Due to the increasing amount of research data, open and reproducible data practices will define the future of medical research. Despite strong conceptual frameworks such as FAIR (Findable, Accessible, Interoperable, Reusable), implementation across laboratories remains inconsistent and fragmented. The MoveD (Haas et al., 2024) initiative outlines open, FAIR, and reproducible data practices in human movement research. However, putting such frameworks into operation remains challenging, especially in imaging-based disciplines, where data are heterogeneous and often under proprietary ecosystems. The Open and Reproducible Musculoskeletal Imaging Research (ORMIR) community and the Universal Musculoskeletal Ultrasonography Database (UMUD) address this issue by implementing reproducible data sharing in musculoskeletal imaging (Bonaretti et al., 2025; Ritsche et al., 2025). Here, we demonstrate implementation of guideline-based, reproducible data practices showcasing the ORMIR Medical Imaging Data Structure (MIDS) and UMUD. One of ORMIR’s aims is to create technical standards for organizing and sharing musculoskeletal imaging data across modalities and disciplines such as MRI, CT, and ultrasound. ORMIR-MIDS defines a transparent folder hierarchy, file-naming conventions, and a metadata scheme that ensure imaging datasets are both human-readable and machine-interpretable. A publicly available Python implementation enables validation, anonymization, and bidirectional conversion between ORMIR-MIDS and common vendor formats, lowering the technical barriers to adoption. Importantly, ORMIR-MIDS is not only a data structure but also a mechanism for community convergence—encouraging laboratories to align their workflows with shared standards that support cross-study comparability, reproducibility, and long-term reusability. UMUD offers an example of how such standards can be applied in ultrasonography research. It provides an openly available webapp that indexes metadata from publicly available musculoskeletal ultrasound datasets hosted on open platforms such as Zenodo. Using a standardized metadata scheme derived from ORMIR and MoveD principles, UMUD enhances the discoverability and comparability of datasets, linking them through descriptors based on expert consensus. By providing contribution and data structuring instructions, UMUD allows the research community to easily contribute their data. UMUD demonstrates how open research data can actively support both methodological innovation and capacity building in the research community. Together, ORMIR and UMUD embody the transition from conceptual to actionable open science. They illustrate how principles articulated in MoveD and FAIR can be realized through interoperable standards, shared infrastructure, and collaboration between technical and applied domains. References Bonaretti, S., Barzegari, M., Bevers, M., Boyd, S., Burghardt, A. J., Cameron, D., Chiumento, F., Crimi, G., Degenhart, G., Durongbhan, P., Hernandez, M. A. E., Fraterrigo, G., Ghasem-Zadeh, A., Grassi, L., Hirvasniemi, J., Hosseinitabatabaei, M., Iori, G., Kok, J., Kuczynski, M., … Zukic, D. (2025). Open and reproducible research in musculoskeletal imaging: Why it matters and how to implement it with the guidelines of the ORMIR community. https://doi.org/10.5281/zenodo.17258830 Haas, M. C., Sommer, B. B., Van Rekum, S., Moerman, F., & Graf, E. S. (2024, November). MoveD - open research data guidelines for movement laboratories. Zenodo. https://doi.org/10.5281/zenodo.14179954 Ritsche, P., Sarto, F., Santini, F., Leitner, C., Franchi, M., Faude, O., Finni, T., Seynnes, O., & Cronin, N. (2025). UMUD: A Web Application for Easy Access to Musculoskeletal Ultrasonography Datasets. Open Science Framework. https://doi.org/10.31219/osf.io/syr4z
- Open Access
- 12 February 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Ultrasonography-Based Patellar Tendon Area Measurement: Comparability of Automated vs. Manual Segmentation
While several openly available tools for the automatic segmentation of the anatomical cross-sectional area (ACSA) of muscle exist, there is no open-source and peer-reviewed tool for the patellar tendon. In this study, we tested an automatic approach for the segmentation of the patellar tendon ACSA in ultrasound images. Images were acquired at 25%, 50%, and 75% of the patellar tendon length from 30 participants (age 46.87 ± 6.03 years; BMI 25.45 ± 4.14 kg/m 2 ). To assess measurement consistency, we evaluated intra-rater and inter-session reliability using manual segmentation of the ACSA. Additionally, we trained three neural networks with a dataset of 497 images to compare manual with automatic segmentation. Intra-rater reliability was found to be good with intraclass correlation coefficient (ICC) of 0.804 (95% CI 0.628–0.902), standard error of measurement (SEM) equal to 0.05 cm 2 (0.03–0.07), and mean absolute error (MAE) of 0.05 cm 2 (0.04–0.07), while inter-session reliability was excellent with ICC of 0.980 (0.970–0.987), SEM equal to 0.02 cm 2 (0.02–0.02), and MAE of 0.02 cm 2 (0.01–0.02). Regarding the comparability with manual analysis after removal of erroneous predictions, ICC was equal to 0.848 (0.702–0.914), SEM was 0.05 (0.04–0.07), and MAE was 0.05 cm 2 (0.05–0.06) with a small standardized mean difference of 0.53 (0.33–0.75). When applying the model, analysis times per image ranged between 0.302 and 0.414 s. The proposed approach enables fast and less operator-dependent patellar tendon ACSA analysis. Although some differences were observed between manual and automatic analysis, this tool, if applied cautiously, could provide valuable support in clinical and research settings.
- 12 February 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
Open AccessUltrasonography-Based Patellar Tendon Area Measurement: Comparability of Automated vs. Manual Segmentation
While several openly available tools for the automatic segmentation of the anatomical cross-sectional area (ACSA) of muscle exist, there is no open-source and peer-reviewed tool for the patellar tendon. In this study, we tested an automatic approach for the segmentation of the patellar tendon ACSA in ultrasound images. Images were acquired at 25%, 50%, and 75% of the patellar tendon length from 30 participants (age 46.87 ± 6.03 years; BMI 25.45 ± 4.14 kg/m 2 ). To assess measurement consistency, we evaluated intra-rater and inter-session reliability using manual segmentation of the ACSA. Additionally, we trained three neural networks with a dataset of 497 images to compare manual with automatic segmentation. Intra-rater reliability was found to be good with intraclass correlation coefficient (ICC) of 0.804 (95% CI 0.628–0.902), standard error of measurement (SEM) equal to 0.05 cm 2 (0.03–0.07), and mean absolute error (MAE) of 0.05 cm 2 (0.04–0.07), while inter-session reliability was excellent with ICC of 0.980 (0.970–0.987), SEM equal to 0.02 cm 2 (0.02–0.02), and MAE of 0.02 cm 2 (0.01–0.02). Regarding the comparability with manual analysis after removal of erroneous predictions, ICC was equal to 0.848 (0.702–0.914), SEM was 0.05 (0.04–0.07), and MAE was 0.05 cm 2 (0.05–0.06) with a small standardized mean difference of 0.53 (0.33–0.75). When applying the model, analysis times per image ranged between 0.302 and 0.414 s. The proposed approach enables fast and less operator-dependent patellar tendon ACSA analysis. Although some differences were observed between manual and automatic analysis, this tool, if applied cautiously, could provide valuable support in clinical and research settings.
- Open Access
- 6 February 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
UMUD: a web application for easy access to musculoskeletal ultrasonography datasets
Background: Ultrasonography is widely used to assess skeletal muscle and tendon properties, such as architecture, cross-sectional area, and tissue stiffness. Despite its growing application in different scenarios, the lack of accessible and standardized public datasets limits large-scale studies and the development of image analysis algorithms. To address this, we developed the Universal Musculoskeletal Ultrasonography Database (UMUD), a platform designed to facilitate access to these datasets and foster standardization in musculoskeletal ultrasonography imaging research. UMUD is an online repository that aggregates and indexes metadata from publicly available musculoskeletal ultrasonography datasets hosted on platforms like the Open Science Framework and Zenodo. By offering detailed metadata descriptors—such as muscle group, ultrasound device, participant demographics, and publication details—UMUD streamlines dataset discovery and exploration through search and visualization tools. Results: So far, UMUD includes 14 Datasets, including 76.124 images (and/or 2.674 videos) derived from 1.901 participants. The platform also includes benchmark datasets for training and validating image analysis algorithms. These comprise multi-expert analyses of muscle architecture and panoramic cross-sectional area images, a dataset containing overlays of muscle geometry for teaching muscle architecture analysis, and labeled datasets for training deep learning models. Additionally, UMUD lists state-of-the-art automated analysis algorithms to support users in their application. Conclusion: UMUD addresses relevant challenges in musculoskeletal ultrasonography by providing a centralized, standardized repository of datasets and tools. Thus, it promotes transparency and innovation in the field, supporting reproducible research and advancements in automated image analysis. Future developments include adding more datasets, refining user functionalities, and introducing community-driven challenges to enhance its impact.
- 6 February 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Open AccessUMUD: a web application for easy access to musculoskeletal ultrasonography datasets
Background: Ultrasonography is widely used to assess skeletal muscle and tendon properties, such as architecture, cross-sectional area, and tissue stiffness. Despite its growing application in different scenarios, the lack of accessible and standardized public datasets limits large-scale studies and the development of image analysis algorithms. To address this, we developed the Universal Musculoskeletal Ultrasonography Database (UMUD), a platform designed to facilitate access to these datasets and foster standardization in musculoskeletal ultrasonography imaging research. UMUD is an online repository that aggregates and indexes metadata from publicly available musculoskeletal ultrasonography datasets hosted on platforms like the Open Science Framework and Zenodo. By offering detailed metadata descriptors—such as muscle group, ultrasound device, participant demographics, and publication details—UMUD streamlines dataset discovery and exploration through search and visualization tools. Results: So far, UMUD includes 14 Datasets, including 76.124 images (and/or 2.674 videos) derived from 1.901 participants. The platform also includes benchmark datasets for training and validating image analysis algorithms. These comprise multi-expert analyses of muscle architecture and panoramic cross-sectional area images, a dataset containing overlays of muscle geometry for teaching muscle architecture analysis, and labeled datasets for training deep learning models. Additionally, UMUD lists state-of-the-art automated analysis algorithms to support users in their application. Conclusion: UMUD addresses relevant challenges in musculoskeletal ultrasonography by providing a centralized, standardized repository of datasets and tools. Thus, it promotes transparency and innovation in the field, supporting reproducible research and advancements in automated image analysis. Future developments include adding more datasets, refining user functionalities, and introducing community-driven challenges to enhance its impact.
- Open Access
- 4 August 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (2) , 1507-1518
Assessment of Lower Limb Muscle Volume Using 3D Ultrasonography: Validity and Reliability Compared to MRI
Introduction: Muscle volume is a key indicator of strength and neuromuscular health, commonly assessed via Magnetic Resonance Imaging (MRI). While accurate, MRI is expensive and time-intensive. Three-dimensional ultrasonography (3DUS) offers a more accessible alternative but requires validation due to its setup-dependent accuracy. This study investigated the validity and reliability of a custom 3DUS setup for measuring lower limb muscle volumes. Methods: Fifteen participants (8 female; 18–40 years) underwent two 3DUS and one MRI sessions. The tibialis anterior, vastus lateralis, gastrocnemii, and biceps femoris muscles were scanned using ultrasonography integrated with a motion capture system. Phantom models were also scanned. After ten participants, the scanning protocol was adapted. 3DUS and MRI volumes were analyzed using 3D Slicer by two raters or one rater, respectively. Reliability was assessed using intra-class correlation (ICC), coefficient of variation (CV%), standard error of measurement (SEM), and minimal detectable change (MDC). Results: 3DUS showed excellent test–retest and inter-rater reliability (ICC = 0.97–0.99; CV% = 2.0–4.6%). MDC values were < 5 mL for all muscles. However, 3DUS systematically underestimated volumes compared to MRI (biases: –10.0 to 33.0%), with best agreement for tibialis anterior and lowest for gastrocnemii. After adapting the protocol, mean differences were reduced by ~ 70%. Phantom scans confirmed both modalities were accurate, suggesting in vivo errors arose from probe pressure and sweep inconsistencies. Conclusion: 3DUS demonstrated excellent reliability but underestimated volumes relative to MRI, influenced by muscle shape and location. Despite limitations, it is a promising, cost-effective method for tracking longitudinal muscle changes. Open methodology supports broader application.
- 4 August 2025
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- Vol. 39 (2) , 1507-1518
Open AccessAssessment of Lower Limb Muscle Volume Using 3D Ultrasonography: Validity and Reliability Compared to MRI
Introduction: Muscle volume is a key indicator of strength and neuromuscular health, commonly assessed via Magnetic Resonance Imaging (MRI). While accurate, MRI is expensive and time-intensive. Three-dimensional ultrasonography (3DUS) offers a more accessible alternative but requires validation due to its setup-dependent accuracy. This study investigated the validity and reliability of a custom 3DUS setup for measuring lower limb muscle volumes. Methods: Fifteen participants (8 female; 18–40 years) underwent two 3DUS and one MRI sessions. The tibialis anterior, vastus lateralis, gastrocnemii, and biceps femoris muscles were scanned using ultrasonography integrated with a motion capture system. Phantom models were also scanned. After ten participants, the scanning protocol was adapted. 3DUS and MRI volumes were analyzed using 3D Slicer by two raters or one rater, respectively. Reliability was assessed using intra-class correlation (ICC), coefficient of variation (CV%), standard error of measurement (SEM), and minimal detectable change (MDC). Results: 3DUS showed excellent test–retest and inter-rater reliability (ICC = 0.97–0.99; CV% = 2.0–4.6%). MDC values were < 5 mL for all muscles. However, 3DUS systematically underestimated volumes compared to MRI (biases: –10.0 to 33.0%), with best agreement for tibialis anterior and lowest for gastrocnemii. After adapting the protocol, mean differences were reduced by ~ 70%. Phantom scans confirmed both modalities were accurate, suggesting in vivo errors arose from probe pressure and sweep inconsistencies. Conclusion: 3DUS demonstrated excellent reliability but underestimated volumes relative to MRI, influenced by muscle shape and location. Despite limitations, it is a promising, cost-effective method for tracking longitudinal muscle changes. Open methodology supports broader application.