MAMilad Alizadeh-Meghrazi

Milad Alizadeh-Meghrazi

*This is an algorithmically generated author record based on publicly available information.

Milad Alizadeh-Meghrazi has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Applications of Smart Textiles for Ambulatory Electrocardiogram Monitoring: Scoping Review of the Literature

    by Clarissa Pedrini Schuch, Gabriela Chaves, Bastien Moineau, Sarah Bennett, Meysam Pirbaglou, Edwin Martin Lobo, Milad Alizadeh-Meghrazi

    Background: Smart textiles (ie, electronic textiles) offer a promising solution to ease continuous electrocardiogram (ECG) monitoring, but their real-world clinical application has been limited. Objective: This review comprehensively examines the current state of research on textile-based ECG monitoring systems, synthesizing current evidence with respect to performance (ie, signal quality, function under static and dynamic conditions), user experience, and current challenges. Methods: A systematic literature search across the PubMed, MEDLINE, and Embase databases from 2000 to 2025 identified 34 research papers eligible for inclusion. Results: Textile-based ECG electrodes demonstrated good signal quality and comfort, particularly under static conditions. Nonetheless, integration into clinical practice requires addressing critical issues, which include greater efforts at validating these technologies in clinical settings and populations, as well as ensuring data security, cost‑effectiveness, user‑friendliness, and data interoperability. Conclusions: Considering the prominence of feasibility research, the successful clinical integration of textile-based ECG monitoring systems requires comprehensive efforts at establishing a clinical evaluation research base (via clinical trials) and developing regulatory policies.


  • Development of reusable cloth mask with nanoparticle filtration efficiency greater than 95%

    by Maryam Ebrahimiazar, Ladan Eskandarian, Samuele Amadio, Andre Khayat, Nasser Ashgriz, Milad Alizadeh-Meghrazi

    ABSRACT After the rapid spread of SARS-Cov-2 virus, the use of masks was suggested by the world health organization (WHO) to reduce the virus transmission, whose primary mode of transmission was suggested to be through respiratory droplets. The recommended face coverings were single use surgical and respirator masks made of non-woven materials. With the increased demand for masks worldwide, the environmental impacts of mask disposal and the pollution caused by microplastic fibers of the non-woven materials were presented. This challenge necessitates the need for the development of a novel reusable mask reducing the environmental effects, while providing the necessary personal protective properties. Based on the ASTM F2299 standard test method, the performance, i.e., particle-size dependent filtration efficiency and pressure drop were studied for 20 samples with multilayer knit fabrics of natural and synthetic fibers (inner layer of pure cotton, cotton-nylon and cotton-polyester, middle layer of Lycra, and outer layer of superhydrophobic polyester). The results show that all the samples had an efficiency of >94% and 87–99% for large (250 nm–1 μm) and small (100–250 nm) particles, respectively. The best performing structure has a material composition of 41% superhydrophobic polyester, 26% natural cotton, 24% nylon and 9% Lycra. The filtration efficiency, pressure drop, and quality factor for this sample are 97.8% (for 100 nm particles), 4.04 mmH2O/cm2 and 4.77 kPa−1, respectively. It was also demonstrated that the developed mask maintains its performance after 50 wash/dry cycles, verifying its reusability. It should be noted that charge neutralizer was not used in the experimental setup of this study which might have led to enhanced results for the filtration efficiency of small (100–250 nm) particles due to the dominance of electrostatic attraction. However, several samples were tested by the third-party company who uses a certified testing equipment based on ASTM F2299, and similar results were obtained. Copyright © 2022 American Association for Aerosol Research

  • 3D‐Knit Dry Electrodes using Conductive Elastomeric Fibers for Long‐Term Continuous Electrophysiological Monitoring

    by Ladan Eskandarian, Amirali Toossi, Farah Nassif, Sahar Golmohammadi Rostami, Siting Ni, Amin Mahnam, Milad Alizadeh Meghrazi, Wataru Takarada, Takeshi Kikutani, Hani E. Naguib

    Recent advances in telemedicine and personalized healthcare have motivated new developments in wearable technologies targeting continuous monitoring of biosignals. Common limitations of wearables for continuous monitoring include durability and breathability of their biopotential electrodes. This paper tackles this challenge by proposing flexible, breathable, and washable dry textile electrodes made of conductive elastomeric filaments (CEFs). First, candidate CEF fibers are characterized. Using an industrial knitting machine, CEF fibers are then directly knitted into textile electrodes. To assess their performance in more realistic circumstances, smart garments with textile electrodes are knitted. Electrocardiograms (ECGs) are acquired using an underwear garment and electrooculograms (EOGs) are acquired using a headband. ECGs and EOGs with textile electrodes are found to have comparable fidelity to that of the gold standard gel electrodes. CEF electrodes are also resistant to repeated wash and dry cycles (30×) and continue to acquire high‐fidelity biosignals. Smart underwear garments are also used to perform continuous ECG measurements in five participants over 24 h of unrestricted daily activities. Results demonstrate the success of these garments in performing high fidelity continuous ECG monitoring. Collectively, these results present CEF electrodes as a promising scalable solution to the challenges of wearable technologies for long‐term continuous electrophysiological monitoring applications.


  • Open Access

    Exploring textile-based electrode materials for electromyography smart garments

    by Emily Lam, Milad Alizadeh-Meghrazi, Alessandra Schlums, Ladan Eskandarian, Amin Mahnam, Bastien Moineau, Milos R Popovic

    Introduction: In recent years, electromyography (EMG) has been increasingly studied for wearable applications. Conventional gel electrodes for electrophysiological recordings have limited use in everyday applications such as prosthetic control or muscular therapy at home. This study investigates the efficacy and feasibility of dry-contact electrode materials employed in smart textiles for EMG recordings. Methods: Dry-contact electrode materials were selected and implemented on textile substrates. Using these electrodes, EMG was recorded from the forearm of able-bodied subjects. 25% and 50% isometric maximum voluntary contractions were captured. A comparative investigation was performed against gel electrodes, assessing the effect of material properties on signal fidelity and strength compared. Results: When isolating for electrode surface area and pressure, 31 of the 40 materials demonstrated strong positive correlations in their mean PSD with gel electrodes (r > 95, p < 0.001). The inclusion of ionic liquids in the material composition, and using raised or flat electrodes, did not demonstrate a significant effect in signal quality. Conclusions: For EMG dry-contact electrodes, comparing the performance against gel electrodes for the application with the selected material is important. Other factors recommended to be studied are electrodes’ durability and long-term stability.


  • Open Access

    A Mass-Producible Washable Smart Garment with Embedded Textile EMG Electrodes for Control of Myoelectric Prostheses: A Pilot Study

    by Milad Alizadeh-Meghrazi, Gurjant Sidhu, Saransh Jain, Michael Stone, Ladan Eskandarian, Amirali Toossi, Milos R. Popovic

    Electromyography (EMG) is the resulting electrical signal from muscle activity, commonly used as a proxy for users’ intent in voluntary control of prosthetic devices. EMG signals are recorded with gold standard Ag/AgCl gel electrodes, though there are limitations in continuous use applications, with potential skin irritations and discomfort. Alternative dry solid metallic electrodes also face long-term usability and comfort challenges due to their inflexible and non-breathable structures. This is critical when the anatomy of the targeted body region is variable (e.g., residual limbs of individuals with amputation), and conformal contact is essential. In this study, textile electrodes were developed, and their performance in recording EMG signals was compared to gel electrodes. Additionally, to assess the reusability and robustness of the textile electrodes, the effect of 30 consumer washes was investigated. Comparisons were made between the signal-to-noise ratio (SNR), with no statistically significant difference, and with the power spectral density (PSD), showing a high correlation. Subsequently, a fully textile sleeve was fabricated covering the forearm, with 14 textile electrodes. For three individuals, an artificial neural network model was trained, capturing the EMG of 7 distinct finger movements. The personalized models were then used to successfully control a myoelectric prosthetic hand.


  • Open Access

    Integrating Electronics to Textiles by Ultrasonic Welding for Cable-Driven Applications for Smart Textiles

    by Sebastian Micus, Sahar Golmohammadi Rostami, Michael Haupt, Götz T. Gresser, Milad Alizadeh Meghrazi, Ladan Eskandarian

    The connection between flexible textiles and stiff electronic components has always been structurally weak and a limiting factor in the establishment of smart textiles in our everyday life. This paper focuses on the formation of reliable connections between conductive textiles and conventional litz wires using ultrasonic welding. The paper offers a promising approach to solving this problem. The electrical and mechanical performance of the samples were investigated after 15 and 30 wash-and-dry cycles in a laundry machine. Here the contact resistances and their peeling strength were measured. Furthermore, their connection properties were analysed in microsections. The resistance of the joints increased more than 300%, because the silver-coated wires suffered under the laundry cycles. Meanwhile, the mechanical strength during the peeling test decreased by only about 20% after 15 cycles and remained the same after 30 cycles. The good results obtained in this study suggest that ultrasonic welding offers a useful approach to the connection of textile electronics to conductive wires and to the manufacture of smart textiles.


  • Open Access

    Evaluation of dry textile electrodes for long-term electrocardiographic monitoring

    by Milad Alizadeh-Meghrazi, Binbin Ying, Alessandra Schlums, Emily Lam, Ladan Eskandarian, Farhana Abbas, Gurjant Sidhu, Amin Mahnam, Bastien Moineau, Milos R. Popovic

    Background: Continuous long-term electrocardiography monitoring has been increasingly recognized for early diagnosis and management of different types of cardiovascular diseases. To find an alternative to Ag/AgCl gel electrodes that are improper for this application scenario, many efforts have been undertaken to develop novel flexible dry textile electrodes integrated into the everyday garments. With significant progresses made to address the potential issues (e.g., low signal-to-noise ratio, high skin–electrode impedance, motion artifact, and low durability), the lack of standard evaluation procedure hinders the further development of dry electrodes (mainly the design and optimization). Results: A standard testing procedure and framework for skin–electrode impedance measurement is demonstrated for the development of novel dry textile electrodes. Different representative electrode materials have been screen-printed on textile substrates. To verify the performance of dry textile electrodes, impedance measurements are conducted on an agar skin model using a universal setup with consistent frequency and pressure. In addition, they are demonstrated for ECG signals acquisition, in comparison to those obtained using conventional gel electrodes. Conclusions: Dry textile electrodes demonstrated similar impedance when in raised or flat structures. The tested pressure variations had an insignificant impact on electrode impedance. Looking at the effect of impedance on ECG signals, a noticeable effect on ECG signal performance metrics was not observed. Therefore, it is suggested that impedance alone is possibly not the primary indicator of signal quality. As well, the developed methods can also serve as useful guidelines for future textile dry-electrode design and testing for practical ECG monitoring applications.


  • Modeling and Reproducing Textile Sensor Noise: Implications for Textile-Compatible Signal Processing Algorithms

    by Yupeng Tian, Muammar Kabir, Mohammad Abdizadeh, Behnaz Poursartip, Amin Mahnam, Presish Bhattachan, Ladan Eskandarian, Milad Alizadeh-Meghrazi, Idir Mellal, Milos R. Popovic, et al.

    Smart textiles provide an opportunity to simultaneously record various electrophysiological signals, e.g., ECG, from the human body in a non-invasive and continuous manner. Accurate processing of ECG signals recorded using textile sensors is challenging due to the very low signal-to-noise ratio (SNR). Signal processing algorithms that can extract ECG signals out of textile-based electrode recordings, despite low SNR are needed. Presently, there are no textile ECG datasets available to develop, test and validate these algorithms. In this paper we attempted to model textile ECG signals by adding the textile sensor noise to open access ECG signals. We employed the linear predictive coding method to model different features of this noise. By approximating the linear predictive coding residual signals using Kernel Density Estimation, an artificial textile ECG noise signal was generated by filtering the residual signal with the linear predictive coding coefficients. The synthetic textile sensor noise was added to the MIT-BIH Arrhythmia Database (MITDB), thus creating Textile-like ECG dataset consisting of 108 trials (30 min each). Furthermore, a Python code for generating textile-like ECG signals with variable SNR was also made available online. Finally, to provide a benchmark for the performance of R-peak detection algorithms on textile ECG, the five common R-peak detection algorithms: Pan & Tompkins, improved Pan & Tompkins (in Biosppy), Hamilton, Engelse, and Khamis, were tested on textile-like MITDB. This work provides an approach to generating noisy textile ECG signals, and facilitating the development, testing, and evaluation of signal processing algorithms for textile ECGs.


  • Open Access

    Evaluation of Dry Textile Electrodes for Long-term Electrocardiographic Monitoring

    by Milad Alizadeh-Meghrazi, Binbin Ying, Alessandra Schlums, Emily Lam, Ladan Eskandarian, Farhana Abbas, Gurjant Sidhu, Amin Mahnam, Bastien Moineau, Milos Popovic

    Background: Continuous long-term electrocardiography monitoring has been increasingly recognized for early diagnosis and management of different types of cardiovascular diseases. To find an alternative to Ag/AgCl gel electrodes that are improper for this application scenario, many efforts have been undertaken to develop novel flexible dry textile electrodes integrated into the everyday garments. With significant progresses made to address the potential issues (e.g., low signal to noise ratio, high skin-electrode impedance, motion artifact, and low durability), the lack of standard evaluation procedure hinders the further development of dry electrodes (mainly the design and optimization).Results: A standard testing procedure and framework for skin-electrode impedance measurement is demonstrated for the development of novel dry textile electrodes. Different representative electrode materials have been screen-printed on textile substrates. To verify the performance of dry textile electrodes, impedance measurements are conducted on an Agar skin model using a universal setup with consistent frequency and pressure. In addition, they are demonstrated for ECG signals acquisition, in comparison to those obtained using conventional gel electrodes.Conclusions: Dry textile electrodes demonstrated similar impedance when in raised or flat structures. The tested pressure variations had an insignificant impact on electrode impedance. Looking at the effect of impedance on ECG signals, a noticeable effect on ECG signal performance metrics was not observed. Therefore, it is suggested that impedance alone is possibly not the primary indicator of signal quality. As well, the developed methods can also serve as useful guidelines for future textile dry electrode design and testing for practical ECG monitoring applications.

  • Open Access

    Additional file 1 of Evaluation of dry textile electrodes for long-term electrocardiographic monitoring

    by Milad Alizadeh-Meghrazi, Binbin Ying, Alessandra Schlums, Emily Lam, Ladan Eskandarian, Farhana Abbas, Gurjant Sidhu, Amin Mahnam, Bastien Moineau, Milos R. Popovic