Orçin Bozkurt
Research Subjects
Orçin Bozkurt has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Melih Bağır
Department of Orthopaedics and Traumatology, Çukurova University Faculty of Medicine, Adana, Turkey
3 shared publications - Akif Mirioğlu
Department of Orthopaedics and Traumatology, Çukurova University, Adana, Turkey
2 shared publications - İsA Bolat
Department of Orthopaedics and Traumatology, Dörtyol State Hospital, Hatay, Türkiye
2 shared publications - Jalal İbRahimov
Department of Orthopaedics and Traumatology, Çukurova University Faculty of Medicine, Adana, Türkiye
2 shared publications - Mustafa Tekin
Department of Orthopaedics and Traumatology, Çukurova University Faculty of Medicine, Adana, Turkey
2 shared publications - Cenk Özkan
Department of Orthopedics and Traumatology, Gültepe, Balcalı Hospital, Adana, Turkey
1 shared publication
Latest Publications
- Open Access
- 11 September 2026
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 60 (5)
Accuracy of Preoperative Radiographic Templating Across Four Widely Used Total Knee Arthroplasty Systems
Objective: This study aimed to evaluate the accuracy of standardized preoperative radiographic templating in predicting femoral and tibial component sizes across four different total knee arthroplasty (TKA) systems in patients undergoing primary TKA for osteoarthritis. Methods: This retrospective, single-center observational study included 160 knees from 141 patients (mean age of 67.3 - 7.9 years) who underwent primary TKA for osteoarthritis between March 2011 and March 2020. Of the 141 patients, 122 underwent unilateral and 19 underwent bilateral TKA. Four different TKA systems were evaluated, with 40 knees assigned to each implant group. Standardized weight-bearing anteroposterior and lateral knee radiographs were used to measure femoral and tibial dimensions using a picture archiving and communication system (PACS). The primary outcome was the agreement between radiographically predicted and intraoperatively implanted femoral and tibial component sizes. Agreement was assessed using weighted Cohen’s kappa (κ), and interobserver reliability was evaluated using the intraclass correlation coefficient (ICC). Results: For femoral components, the exact size was predicted in 76.9% of knees, and 96.8% of predictions were within - 1 implant size. For tibial components, the exact size was predicted in 64.4% of knees, and 92.5% were within - 1 implant size. Agreement between predicted and implanted sizes was substantial for femoral components (κ = 0.70, 95% CI, 0.62–0.78) and moderate for tibial components (κ = 0.54, 95% CI, 0.45–0.63). Size discrepancies differed significantly among the four implant systems for both tibial (P = 0.001) and femoral components (P = 0.010). Overall, 94.4% (302/320) of all component size predictions were within - 1 implant size. Conclusion: Standardized preoperative radiographic templating reliably predicted component size across four different TKA systems, with greater accuracy for femoral than for tibial components. When standardized radiographic acquisition, calibration, and measurement protocols are applied, conventional two-dimensional templating can provide clinically acceptable component-size predictions across different implant designs. These findings support its clinical utility as an accessible and cost-effective method for preoperative planning in primary TKA. Cite this article as: Bolat İ, Tekin M, İbrahimov J, Bozkurt O. Accuracy of standardized preoperative radiographic templating in predicting implant size: a comparative analysis of four widely used total knee arthroplasty systems. Acta Orthop Traumatol Turc., 2026; 60(5), 0811, doi: 10.5152/j.aott.2026.25811.
- 11 September 2026
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 60 (5)
Open AccessAccuracy of Preoperative Radiographic Templating Across Four Widely Used Total Knee Arthroplasty Systems
Objective: This study aimed to evaluate the accuracy of standardized preoperative radiographic templating in predicting femoral and tibial component sizes across four different total knee arthroplasty (TKA) systems in patients undergoing primary TKA for osteoarthritis. Methods: This retrospective, single-center observational study included 160 knees from 141 patients (mean age of 67.3 - 7.9 years) who underwent primary TKA for osteoarthritis between March 2011 and March 2020. Of the 141 patients, 122 underwent unilateral and 19 underwent bilateral TKA. Four different TKA systems were evaluated, with 40 knees assigned to each implant group. Standardized weight-bearing anteroposterior and lateral knee radiographs were used to measure femoral and tibial dimensions using a picture archiving and communication system (PACS). The primary outcome was the agreement between radiographically predicted and intraoperatively implanted femoral and tibial component sizes. Agreement was assessed using weighted Cohen’s kappa (κ), and interobserver reliability was evaluated using the intraclass correlation coefficient (ICC). Results: For femoral components, the exact size was predicted in 76.9% of knees, and 96.8% of predictions were within - 1 implant size. For tibial components, the exact size was predicted in 64.4% of knees, and 92.5% were within - 1 implant size. Agreement between predicted and implanted sizes was substantial for femoral components (κ = 0.70, 95% CI, 0.62–0.78) and moderate for tibial components (κ = 0.54, 95% CI, 0.45–0.63). Size discrepancies differed significantly among the four implant systems for both tibial (P = 0.001) and femoral components (P = 0.010). Overall, 94.4% (302/320) of all component size predictions were within - 1 implant size. Conclusion: Standardized preoperative radiographic templating reliably predicted component size across four different TKA systems, with greater accuracy for femoral than for tibial components. When standardized radiographic acquisition, calibration, and measurement protocols are applied, conventional two-dimensional templating can provide clinically acceptable component-size predictions across different implant designs. These findings support its clinical utility as an accessible and cost-effective method for preoperative planning in primary TKA. Cite this article as: Bolat İ, Tekin M, İbrahimov J, Bozkurt O. Accuracy of standardized preoperative radiographic templating in predicting implant size: a comparative analysis of four widely used total knee arthroplasty systems. Acta Orthop Traumatol Turc., 2026; 60(5), 0811, doi: 10.5152/j.aott.2026.25811.
- Open Access
- 19 November 2021
- Published by Joint Diseases and Related Surgery in Joint Diseases and Related Surgery
- Vol. 32 (3) , 688-697
The histological effect of tranexamic acid on tendon-to-bone healing histologically in rats
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.
- 19 November 2021
- Published by Joint Diseases and Related Surgery in Joint Diseases and Related Surgery
- Vol. 32 (3) , 688-697
Open AccessThe histological effect of tranexamic acid on tendon-to-bone healing histologically in rats
Joint Diseases and Related Surgery (JDRS), the official journal of the Turkish Joint Diseases Foundation, is an international, peer-reviewed, immediate open access journal. All published articles in JDRS has been free for everyone, without embargo, since 1990.
- 1 October 2021
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 40 (5) , 702-703
A rare clinical entity: Florid reactive periostitis. Case report and literature review
- 1 October 2021
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 40 (5) , 702-703
A rare clinical entity: Florid reactive periostitis. Case report and literature review
- Open Access
- 1 January 2021
- Published by Cukurova Medical Journal in Cukurova Medical Journal
- Vol. 46 (4) , 1730-1732
Secondary carpal tunnel syndrome caused by space-occupying lesion-lipoma
The etiology of carpal tunnel syndrome is various. One of these etiological factors is space- occupying lesions in the carpal tunnel. Karpal tünel sendromunun etiyolojisi çeşitlidir. Bu etiyolojik faktörlerden biri de karpal tünelde yer kaplayan lezyondur.
- 1 January 2021
- Published by Cukurova Medical Journal in Cukurova Medical Journal
- Vol. 46 (4) , 1730-1732
Open AccessSecondary carpal tunnel syndrome caused by space-occupying lesion-lipoma
The etiology of carpal tunnel syndrome is various. One of these etiological factors is space- occupying lesions in the carpal tunnel. Karpal tünel sendromunun etiyolojisi çeşitlidir. Bu etiyolojik faktörlerden biri de karpal tünelde yer kaplayan lezyondur.