Dechuan Qiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dechuan Qiu has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Kazunobu Nagasaki
Kyoto University
6 shared publications - Shinichiro Kado
Kyoto University
6 shared publications - Shinji Kobayashi
Kyoto University
6 shared publications - Shinsuke Ohshima
Institute of Advanced Energy, Kyoto University, Uji, Kyoto, Japan
6 shared publications H. Okada
Institute of Advanced Energy, Kyoto University 2 , Uji, Kyoto 611-0011, Japan
4 shared publications- Pengfei Zhang
Graduate School of Energy Science, Kyoto University 1 , Uji, Kyoto 611-0011, Japan
4 shared publications
Latest Publications
- Open Access
- 1 September 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (9)
Characterization of a retroreflector array for 320-GHz interferometer system in Heliotron J
A retroreflector array, composed of a cluster of small retroreflectors, is experimentally studied for application to a Michelson-type interferometer system in the fusion plasma experiment. Such a new-type reflector has the potential to be a vital and effective tool at a spatially limited location, such as on the vacuum chamber wall of plasma experimental devices. To investigate the effect of retroreflector array on the reflected beam properties, a tabletop experiment is performed with the retroreflector array composed of 4 mm corner-cube retroreflectors and with a 320-GHz (λ ∼ 0.937 mm) submillimeter wave source. An imaging camera is utilized to measure the submillimeter wave beam profile and is scanned perpendicularly to the beam propagation direction if necessary. The experimental result exhibits a diffraction effect on the reflected beam, resulting in the emergence of discrete peaks on the reflected beam profile, as predicted in the past numerical study; however, the most reflected beam power converges on the one reflected into the incident direction, resulting from a property as a retroreflector. Furthermore, the dependence of the reflected beam on the incident beam angle is characterized while fixing the detector position, and the retroreflection beam intensity is found to vary due to the diffraction effect. Such an undesired variation of beam intensity induced by the diffraction can be suppressed with a focusing lens placed in front of the detector in the practical application to an interferometer.
- 1 September 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (9)
Open AccessCharacterization of a retroreflector array for 320-GHz interferometer system in Heliotron J
A retroreflector array, composed of a cluster of small retroreflectors, is experimentally studied for application to a Michelson-type interferometer system in the fusion plasma experiment. Such a new-type reflector has the potential to be a vital and effective tool at a spatially limited location, such as on the vacuum chamber wall of plasma experimental devices. To investigate the effect of retroreflector array on the reflected beam properties, a tabletop experiment is performed with the retroreflector array composed of 4 mm corner-cube retroreflectors and with a 320-GHz (λ ∼ 0.937 mm) submillimeter wave source. An imaging camera is utilized to measure the submillimeter wave beam profile and is scanned perpendicularly to the beam propagation direction if necessary. The experimental result exhibits a diffraction effect on the reflected beam, resulting in the emergence of discrete peaks on the reflected beam profile, as predicted in the past numerical study; however, the most reflected beam power converges on the one reflected into the incident direction, resulting from a property as a retroreflector. Furthermore, the dependence of the reflected beam on the incident beam angle is characterized while fixing the detector position, and the retroreflection beam intensity is found to vary due to the diffraction effect. Such an undesired variation of beam intensity induced by the diffraction can be suppressed with a focusing lens placed in front of the detector in the practical application to an interferometer.
- 1 February 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (2) , 023510
Increased signal separation upgrade permits preliminary electron anisotropy measurements with Heliotron J multi-pass Thomson diagnostic
A signal separation system is constructed on the multi-pass Thomson scattering system of Heliotron J to solve the problem of overlapping scattered light signals for the electron temperature anisotropy measurement. The phenomenon of overlapping scattered light signals is relieved by operating the signal separation system. A Raman scattering experiment is undertaken to verify the separation effect of the signal separation system. Two scattered light signals corresponding to two adjacent incidences of one laser shot were extended to 104 ns. Moreover, we applied the multi-pass Thomson scattering system with signal separation system to the electron temperature anisotropy measurement. No anisotropy was observed within the error bars in the initial experiment.
- 1 February 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (2) , 023510
Increased signal separation upgrade permits preliminary electron anisotropy measurements with Heliotron J multi-pass Thomson diagnostic
A signal separation system is constructed on the multi-pass Thomson scattering system of Heliotron J to solve the problem of overlapping scattered light signals for the electron temperature anisotropy measurement. The phenomenon of overlapping scattered light signals is relieved by operating the signal separation system. A Raman scattering experiment is undertaken to verify the separation effect of the signal separation system. Two scattered light signals corresponding to two adjacent incidences of one laser shot were extended to 104 ns. Moreover, we applied the multi-pass Thomson scattering system with signal separation system to the electron temperature anisotropy measurement. No anisotropy was observed within the error bars in the initial experiment.
- 1 January 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (1) , 013503
Design of a dual scattering angle multi-pass Thomson scattering system with signal separation function on Heliotron J
This paper proposes a design of dual scattering angles multi-path Thomson scattering system with a signal separation function to solve the overlapping phenomenon of scattered light signals and to increase the measurement accuracy for the investigation of anisotropic electron velocity distribution. Furthermore, an optical path design is proposed to demonstrate how overlapping scattered light signals can be separated by setting the optical path in a limited room with a compact layout, which makes the incident interval between two overlapping scattered light signals 1.7 times longer than that of our current system. The specific position of each optical component existing in the system is determined via a Gaussian beam analysis to avoid damage caused by overexpansion of spot size with the application of two cooperating image relay systems. Conversely, a polychromator is optimized by resetting the pass waveband of the interference filter combination to achieve high accuracy in electron temperature (Te) measurement corresponding to two scattering angles simultaneously.
- 1 January 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (1) , 013503
Design of a dual scattering angle multi-pass Thomson scattering system with signal separation function on Heliotron J
This paper proposes a design of dual scattering angles multi-path Thomson scattering system with a signal separation function to solve the overlapping phenomenon of scattered light signals and to increase the measurement accuracy for the investigation of anisotropic electron velocity distribution. Furthermore, an optical path design is proposed to demonstrate how overlapping scattered light signals can be separated by setting the optical path in a limited room with a compact layout, which makes the incident interval between two overlapping scattered light signals 1.7 times longer than that of our current system. The specific position of each optical component existing in the system is determined via a Gaussian beam analysis to avoid damage caused by overexpansion of spot size with the application of two cooperating image relay systems. Conversely, a polychromator is optimized by resetting the pass waveband of the interference filter combination to achieve high accuracy in electron temperature (Te) measurement corresponding to two scattering angles simultaneously.
- 1 November 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (11) , 113519
Development and initial results of 320 GHz interferometer system in Heliotron J
A new 320 GHz solid-state source interferometer is installed in the Heliotron J helical device to explore the physics of high-density plasmas (ne > 2–3 × 1019 m−3, typically) realized with advanced fueling techniques. This interferometry system is of the Michelson type and is based on the heterodyne principle, with two independent solid-state sources that can deliver an output power of up to 50 mW. A high time resolution measurement of µs can be derived by tuning the frequency of one source in the frequency range of 312–324 GHz on the new system, which can realize the fluctuation measurement. We successfully measured the line-averaged electron density in high-density plasma experiments. The measured density agreed well with a microwave interferometer measurement using a different viewing chord, demonstrating that the new system can be used for routine diagnostics of electron density in Heliotron J.
- 1 November 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (11) , 113519
Development and initial results of 320 GHz interferometer system in Heliotron J
A new 320 GHz solid-state source interferometer is installed in the Heliotron J helical device to explore the physics of high-density plasmas (ne > 2–3 × 1019 m−3, typically) realized with advanced fueling techniques. This interferometry system is of the Michelson type and is based on the heterodyne principle, with two independent solid-state sources that can deliver an output power of up to 50 mW. A high time resolution measurement of µs can be derived by tuning the frequency of one source in the frequency range of 312–324 GHz on the new system, which can realize the fluctuation measurement. We successfully measured the line-averaged electron density in high-density plasma experiments. The measured density agreed well with a microwave interferometer measurement using a different viewing chord, demonstrating that the new system can be used for routine diagnostics of electron density in Heliotron J.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053519
Development of a multi-channel 320 GHz interferometer for high density plasma measurement in Heliotron J
We report the development of a new interferometer with two stable, high-power, 320 GHz solid-state sources in Heliotron J. A heterodyne Michelson interferometer optical scheme is employed. Two solid-state oscillators are utilized as sources with a fixed frequency at 320 GHz and frequency tunable of 312–324 GHz. Quasi-optical techniques are used for beam transmission. The beam is elongated in the vertical direction with two off-axis parabolic mirrors and injected into the plasma as a sheet beam for the multi-channel measurement (>5 ch.). Passing through the plasma, the beam is reflected at a retroreflector-array installed at the vacuum chamber wall. The retroreflector-array is a bunch of retroreflector structures, which can suppress the beam refraction caused by plasma without much space inside a vacuum chamber unlike a single retroreflector and can facilitate the system design. The source, detectors, and the retroreflector-array are tested to evaluate their basic performance on a tabletop experiment.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053519
Development of a multi-channel 320 GHz interferometer for high density plasma measurement in Heliotron J
We report the development of a new interferometer with two stable, high-power, 320 GHz solid-state sources in Heliotron J. A heterodyne Michelson interferometer optical scheme is employed. Two solid-state oscillators are utilized as sources with a fixed frequency at 320 GHz and frequency tunable of 312–324 GHz. Quasi-optical techniques are used for beam transmission. The beam is elongated in the vertical direction with two off-axis parabolic mirrors and injected into the plasma as a sheet beam for the multi-channel measurement (>5 ch.). Passing through the plasma, the beam is reflected at a retroreflector-array installed at the vacuum chamber wall. The retroreflector-array is a bunch of retroreflector structures, which can suppress the beam refraction caused by plasma without much space inside a vacuum chamber unlike a single retroreflector and can facilitate the system design. The source, detectors, and the retroreflector-array are tested to evaluate their basic performance on a tabletop experiment.
- 1 February 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (02) , C02011
Current status and plan of development of Nd:YAG laser Thomson scattering system in Heliotron J
An Nd:YAG Thomson Scattering system has been developed in Heliotron J. The Thomson scattering system is used for an investigation of an improved confinement physics such as the edge transport barrier (H-mode) or the internal transport barrier of the helical plasma. The system has 25 spatial points with ~10 mm resolution. Two high repetition Nd:YAG lasers (> 500mJ@50 Hz) realize the measurement of the time evolution of the plasma profile with 10 ms time intervals. The scattered light is collected with a large concave mirror (D=800 mm) with a solid angle of ~80–100 mstr. The laser beam is injected from obliquely downward to upward, and obliquely backscattered light is detected. A multi-path Thomson scattering system is under development to measure anisotropic electron velocity distribution and to increase the accuracy of the density and temperature profiles. First, we have applied a double-path Thomson scattering system using a Faraday rotator to the Heliotron J. The clear backward and forward scattered lights are successfully detected. Now the system is upgraded to a multi-path system using a pockels cell. The final goal of the development is the system that has two pockels cells to separate the backward and forward scattered lights.
- 1 February 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (02) , C02011
Current status and plan of development of Nd:YAG laser Thomson scattering system in Heliotron J
An Nd:YAG Thomson Scattering system has been developed in Heliotron J. The Thomson scattering system is used for an investigation of an improved confinement physics such as the edge transport barrier (H-mode) or the internal transport barrier of the helical plasma. The system has 25 spatial points with ~10 mm resolution. Two high repetition Nd:YAG lasers (> 500mJ@50 Hz) realize the measurement of the time evolution of the plasma profile with 10 ms time intervals. The scattered light is collected with a large concave mirror (D=800 mm) with a solid angle of ~80–100 mstr. The laser beam is injected from obliquely downward to upward, and obliquely backscattered light is detected. A multi-path Thomson scattering system is under development to measure anisotropic electron velocity distribution and to increase the accuracy of the density and temperature profiles. First, we have applied a double-path Thomson scattering system using a Faraday rotator to the Heliotron J. The clear backward and forward scattered lights are successfully detected. Now the system is upgraded to a multi-path system using a pockels cell. The final goal of the development is the system that has two pockels cells to separate the backward and forward scattered lights.
- 1 August 2017
- Published by Elsevier in Optics Communications
- Vol. 396, 92-99
Research of partition function on optical properties and temperature diagnosis of air plasma
- 1 August 2017
- Published by Elsevier in Optics Communications
- Vol. 396, 92-99
Research of partition function on optical properties and temperature diagnosis of air plasma