Stanislav Serov
Research Subjects
Stanislav Serov has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- S. N. Tugarinov
Institution “Project Center ITER,” 1 Moscow
2 shared publications V. V. Serov
Institution “Project Center ITER,” 1 Moscow
2 shared publicationsA. V. Krasilnikov
Institution “Project Center ITER”, State Atomic Energy Corporation “Rosatom”, Moscow, Russia
1 shared publication- A. V. Zvonkov
Institution “Project Center ITER,” 1 Moscow
1 shared publication - A. Yu. Shabashov
Institution “Project Center ITER,” 1 Moscow
1 shared publication - Detlev Reiter
Institute for Energy and Climate Research IEK-4, Forschungszentrum Jülich GmbH, 52425 Jülich, Germany
1 shared publication
Latest Publications
- 1 March 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (3)
Development of Charge eXchange Recombination Spectroscopy (CXRS) edge plasma diagnostic system for International Thermonuclear Experimental Reactor (ITER)
Charge eXchange Recombination Spectroscopy (CXRS) is a powerful diagnostic tool for hot plasmas, widely used on modern tokamaks and stellarators for measuring ion temperature, rotation velocity, and low-Z impurity concentration. Three CXRS diagnostics, observing different plasma regions, will be implemented on the ITER (International Thermonuclear Experimental Reactor) tokamak. In this paper, one of the ITER diagnostics, CXRS Edge, is described. An overview of its hardware, including a diagnostic neutral beam, a light collection system consisting of four in-vessel mirrors, vacuum windows, lens assemblies, fiber bundles, an alignment system, and back-end equipment (spectrometers, calibration equipment, and instrumentation and control) is presented. Laboratory tests of several manufactured mock-ups are described. The process of the diagnostic preparation for operation and specifics of measurement data analysis for CXRS on ITER is reviewed. A calibration system using a retroreflector, developed for remote calibration of the CXRS Edge diagnostic, is presented. CXRS modeling approaches and results are outlined. Non-statistical errors, their influence on parameters measurement, and possible solutions are also discussed.
- 1 March 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (3)
Development of Charge eXchange Recombination Spectroscopy (CXRS) edge plasma diagnostic system for International Thermonuclear Experimental Reactor (ITER)
Charge eXchange Recombination Spectroscopy (CXRS) is a powerful diagnostic tool for hot plasmas, widely used on modern tokamaks and stellarators for measuring ion temperature, rotation velocity, and low-Z impurity concentration. Three CXRS diagnostics, observing different plasma regions, will be implemented on the ITER (International Thermonuclear Experimental Reactor) tokamak. In this paper, one of the ITER diagnostics, CXRS Edge, is described. An overview of its hardware, including a diagnostic neutral beam, a light collection system consisting of four in-vessel mirrors, vacuum windows, lens assemblies, fiber bundles, an alignment system, and back-end equipment (spectrometers, calibration equipment, and instrumentation and control) is presented. Laboratory tests of several manufactured mock-ups are described. The process of the diagnostic preparation for operation and specifics of measurement data analysis for CXRS on ITER is reviewed. A calibration system using a retroreflector, developed for remote calibration of the CXRS Edge diagnostic, is presented. CXRS modeling approaches and results are outlined. Non-statistical errors, their influence on parameters measurement, and possible solutions are also discussed.
- 1 August 2022
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 48 (8) , 844-854
Development of the Diagnostic System “Active Spectroscopy” (CXRS) for the TRT Facility
TRT (Tokamak with Reactor Technologies) is the next major step in Russia’s National Controlled Fusion Program. The TRT facility is designed to develop technologies for providing a long operating pulse that is possible using high-temperature superconductivity. To control the operation of the TRT facility and control the parameters of thermonuclear plasma, it is necessary to develop and create a whole complex of diagnostic systems. One of the planned diagnostic systems for TRT is the “Active spectroscopy” diagnostic abbreviated in literature as CXRS. The development of this diagnostic is possible using either the heating or the diagnostic neutral beams. Its tasks include measuring the most important plasma parameters such as ion temperature, plasma rotation velocity, and the concentration of light impurities along the entire radius of the plasma column. This work presents the development of the Active Spectroscopy diagnostic system for the TRT facility. The levels of the active and background signals, as well as the signal-to-noise ratio are estimated. The simulation results for the spectral profiles of plasma radiation are presented. Based on the simulation results, a measurement scheme is proposed that takes into account the need for simultaneous measurements for the different spatial points. A description of the proposed light collection system from the plasma is given, as well as a description of the proposed measuring equipment. The accuracy of measuring individual plasma parameters and the achievable spatial resolution are estimated.
- 1 August 2022
- Published by Pleiades Publishing Ltd in Plasma Physics Reports
- Vol. 48 (8) , 844-854
Development of the Diagnostic System “Active Spectroscopy” (CXRS) for the TRT Facility
TRT (Tokamak with Reactor Technologies) is the next major step in Russia’s National Controlled Fusion Program. The TRT facility is designed to develop technologies for providing a long operating pulse that is possible using high-temperature superconductivity. To control the operation of the TRT facility and control the parameters of thermonuclear plasma, it is necessary to develop and create a whole complex of diagnostic systems. One of the planned diagnostic systems for TRT is the “Active spectroscopy” diagnostic abbreviated in literature as CXRS. The development of this diagnostic is possible using either the heating or the diagnostic neutral beams. Its tasks include measuring the most important plasma parameters such as ion temperature, plasma rotation velocity, and the concentration of light impurities along the entire radius of the plasma column. This work presents the development of the Active Spectroscopy diagnostic system for the TRT facility. The levels of the active and background signals, as well as the signal-to-noise ratio are estimated. The simulation results for the spectral profiles of plasma radiation are presented. Based on the simulation results, a measurement scheme is proposed that takes into account the need for simultaneous measurements for the different spatial points. A description of the proposed light collection system from the plasma is given, as well as a description of the proposed measuring equipment. The accuracy of measuring individual plasma parameters and the achievable spatial resolution are estimated.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053517
Measurement performance assessment for the ITER CXRS Edge diagnostic system
Measurement performance assessment has been carried out for the latest design of the ITER Charge Exchange Recombination Spectroscopy (CXRS) Edge diagnostic system. Several plasma scenarios, covering all expected baseline operation regimes for ITER, were used. Various impurity (He, Be, C, and Ne) concentrations for the system whole spatial range (0.5 < r/a < 1.0) were considered. Statistical errors for the measurements of low-Z impurity temperature, density, and rotation velocity were calculated. Other non-statistical error sources were reviewed, including the presence of wall reflections, effects on the active charge-exchange line shape, calibration, and positioning uncertainties. Minimal impurity concentrations, allowing measurements with required accuracy, were obtained. It was shown that the CXRS Edge system will be able to measure primary plasma parameters with required accuracy, space, and time resolution.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053517
Measurement performance assessment for the ITER CXRS Edge diagnostic system
Measurement performance assessment has been carried out for the latest design of the ITER Charge Exchange Recombination Spectroscopy (CXRS) Edge diagnostic system. Several plasma scenarios, covering all expected baseline operation regimes for ITER, were used. Various impurity (He, Be, C, and Ne) concentrations for the system whole spatial range (0.5 < r/a < 1.0) were considered. Statistical errors for the measurements of low-Z impurity temperature, density, and rotation velocity were calculated. Other non-statistical error sources were reviewed, including the presence of wall reflections, effects on the active charge-exchange line shape, calibration, and positioning uncertainties. Minimal impurity concentrations, allowing measurements with required accuracy, were obtained. It was shown that the CXRS Edge system will be able to measure primary plasma parameters with required accuracy, space, and time resolution.
- Open Access
Simulation of Spectra Code (SOS) for ITER Active Beam Spectroscopy
The concept and structure of the Simulation of Spectra (SOS) code is described starting with an introduction to the physics background of the project and the development of a simulation tool enabling the modeling of charge-exchange recombination spectroscopy (CXRS) and associated passive background spectra observed in hot fusion plasmas. The generic structure of the code implies its general applicability to any fusion device, the development is indeed based on over two decades of spectroscopic observations and validation of derived plasma data. Four main types of active spectra are addressed in SOS. The first type represents thermal low-Z impurity ions and the associated spectral background. The second type of spectra represent slowing-down high energy ions created from either thermo-nuclear fusion reactions or ions from injected high energy neutral beams. Two other modules are dedicated to CXRS spectra representing bulk plasma ions (H+, D+, or T+) and beam emission spectroscopy (BES) or Motional Stark Effect (MSE) spectrum appearing in the same spectral range. The main part of the paper describes the physics background for the underlying emission processes: active and passive CXRS emission, continuum radiation, edge line emission, halo and plume effect, or finally the charge exchange (CX) cross-section effects on line shapes. The description is summarized by modeling the fast ions emissions, e.g., either of the α particles of the fusion reaction or of the beam ions itself.
Open AccessSimulation of Spectra Code (SOS) for ITER Active Beam Spectroscopy
The concept and structure of the Simulation of Spectra (SOS) code is described starting with an introduction to the physics background of the project and the development of a simulation tool enabling the modeling of charge-exchange recombination spectroscopy (CXRS) and associated passive background spectra observed in hot fusion plasmas. The generic structure of the code implies its general applicability to any fusion device, the development is indeed based on over two decades of spectroscopic observations and validation of derived plasma data. Four main types of active spectra are addressed in SOS. The first type represents thermal low-Z impurity ions and the associated spectral background. The second type of spectra represent slowing-down high energy ions created from either thermo-nuclear fusion reactions or ions from injected high energy neutral beams. Two other modules are dedicated to CXRS spectra representing bulk plasma ions (H+, D+, or T+) and beam emission spectroscopy (BES) or Motional Stark Effect (MSE) spectrum appearing in the same spectral range. The main part of the paper describes the physics background for the underlying emission processes: active and passive CXRS emission, continuum radiation, edge line emission, halo and plume effect, or finally the charge exchange (CX) cross-section effects on line shapes. The description is summarized by modeling the fast ions emissions, e.g., either of the α particles of the fusion reaction or of the beam ions itself.