Latest Publications

  • Adapting mammography DRLs for improved usability

    by Gillian Power, Paola Baldelli, Sarah Barry, Elizabeth Keavey, Niall Phelan

    Introduction: Dose audit and diagnostic reference levels should promote continuing optimization and patient protection. The objective of this work is to extend the diagnostic reference level concept by formulating benchmarks stratified by breast thickness and system type, and to make these benchmarks readily available to facilitate ongoing real-time audit. Materials and Method: After comparing the Facility diagnostic reference levels with the National one, the data set was divided into groups based on compressed breast thickness and system type. Benchmarks were established at the 95th percentile for individual categories, each combining a compressed breast thickness range with a system-type. Results: A Dose Management System was used to compare the median values of each individual system against the relevant benchmark. This enabled ongoing, pertinent comparisons of data in real-time. Conclusion: Comparison to the relevant benchmark helps to quickly identify systems requiring investigation and possible optimization. This transforms dose auditing into a proactive tool rather than a retrospective one.

  • A statistical alternative to current measures of image quality in digital mammography

    by D Caldwell, P Baldelli, N Phelan, P Kenny

    Objective . Mammogram image quality in European breast screening systems is defined by threshold gold thickness ( T ) assessment of the CDMAM contrast-detail phantom. Previous studies have outlined several limitations of the phantom including expense, number of images required and inter-phantom manufacturing variability. Two alternative approaches to image quality assessment for routine quality control are examined and compared to the CDMAM technique: (i) A detectability index ( d ′) based on a non-prewhitened model observer with an eye filter (NPWE) an d (ii) A statistical estimate of contrast based on image noise levels ( C STAT ). Approach . The d ′ calculation follows a previously published methodology based on the NNPS and contrast, both measured from an image of 5 cm of PMMA containing a 0.2 mm Al target, as well as the MTF measured under standard conditions. For the proposed statistical method, pixels in the centre of the same NNPS image were re-binned into a range of equivalent CDMAM target areas. For any area, the minimum contrast necessary to distinguish a signal from the background, C STAT , is 3.29 σ at a 95% level of confidence, where σ is the standard deviation of the background pixels. Theoretical analysis predicts a simple relationships between C STAT , T and d ′. Measured values of C STAT were compared to T and d ′ as a function of air kerma at the detector for ten digital mammography systems from three different manufacturers. Main Results . Theoretical relationships between C STAT , d ′ and T were demonstrated. Minimum acceptable image quality performance for 0.10 and 0.25 mm diameter discs, defined by the European Guidelines in terms of T , are equivalent to d ′ values of 0.85 and 5.36 and threshold C STAT values of 0.055 and 0.022. Significance . Strong correlations between log( T ), log( d ′) and log( C STAT ) suggest that either alternative approach produces information corresponding to that obtained using the CDMAM. C STAT should be considered as a simple, objective and cost-effective alternative to routine image quality assessment in mammography.


  • Evaluation of microcalcification contrast in clinical images for digital mammography and synthetic mammography

    by P. Baldelli, P. Cardarelli, F. Flanagan, S. Maguire, N. Phelan, S. Tomasi, A. Taibi


  • Optimising Mammography Image Quality

    by Elizabeth Keavey, Paola Baldelli, Michael Manley, Gillian Power, Niall Phelan


  • Methodology for undertaking quality control testing of ghosting in digital breast tomosynthesis systems

    by Alistair Mackenzie, Nicholas W. Marshall, Paola Baldelli, Riyad Khan, Ruben van Engen

    Purpose: Low levels of ghosting are found during quality control of digital mammography (DM). In digital breast tomosynthesis (DBT) mode, the x-ray detector is not cleared during the series of exposures potentially leading to ghosting issues. Methods: The ghosting image factor (GIF) was calculated for systems from three manufacturers as follows. A 45 mm thick polymethyl methacrylate (PMMA) block covering half the detector was imaged, followed by the PMMA block plus 0.1 mm thick aluminium sheet centred on the block, this time positioned to fully cover the detector. This was undertaken for (1) DM and (2) between separate DBT scans. Inter-projection ghosting (3) was measured by moving the PMMA block from covering half the detector to covering the whole detector after the first projection. In method (4), a 3 mm thick aluminium plate with a 0.1 mm thick aluminium sheet on top was placed on the compression paddle at 100 mm above the breast covering half of the detector. Results: The GIF measured via test (1) and (2) was lower than the 0.3 tolerance set in the European guidelines for DM, however higher values were found for one system in DBT mode. Test 3, inter-projection GIF values were between 0.08 and 0.89, mostly above 0.3. Test 4 was a practical method and gave larger GIF values of between 1.07 and 8.01. Conclusions Ghosting factors measured between projections are considerably higher than the GIF measured between separate DBT scans. We propose a simple method using an aluminium plate to estimate the GIF.

  • Investigation of detector uniformity issues for Siemens Inspiration systems

    by P. Baldelli, E. Keavey, M. Manley, G. Power, N. Phelan


  • Quantitative analysis of the effect of energy separation in k-edge digital subtraction imaging

    by A Sarnelli, A Taibi, P Baldelli, M Gambaccini, A Bravin

    The aim of the work is to quantitatively compare the effect of the energy separation in the k-edge digital subtraction imaging technique. Images of a custom-made, iodine filled (k-edge = 33.17 keV) test object have been acquired with monochromatic x-ray beams (energy spread <0.1 keV) at the ID17 biomedical beamline of the ESRF. Image acquisition has been performed using two energy separations, namely 0.65 keV (32.85 keV and 33.5 keV, respectively) and 4.4 keV (31.2 keV and 35.6 keV, respectively), using beams of energies on either side of the iodine k-edge. Signal and signal-to-noise ratio (SNR) analysis has been performed as a function of DeltaE and the contrast medium concentrations. The results show that the SNR values measured for DeltaE < 1 keV are only slightly higher than those measured for DeltaE = 4.4 keV. This preliminary study shows that monochromaticity and the energy separation obtained with quasi monochromatic beams from conventional x-ray sources might be suitable for this imaging technique.


  • Application of the K-edge X-ray technique to map pigments of art paintings: Preliminary results

    by Paola Baldelli, Letizia Bonizzoni, M. Gambaccini, Marco Gargano, Logan Ludwig, Mario Milazzo, Lucia Pasetti, F. Petrucci, F. Prino, L. Ramello, et al.