Paola Baldelli
Research Subjects
Paola Baldelli has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Angelo Taibi
University of Ferrara
3 shared publications - Mauro Gambaccini
Department of Physics and Earth Sciences, University of Ferrara, Ferrara, Italy
3 shared publications Elizabeth Keavey
BreastCheck, National Cancer Screening Service, Western unit , Newcastle Rd H91YR4R , Galway
2 shared publicationsGillian Power
BreastCheck, National Cancer Screening Service, Merrion unit , Merrion Rd D04VP6 , Dublin
2 shared publications- Michael Manley
BreastCheck, National Screening Service, Ireland
2 shared publications - Niall Phelan
BreastCheck, National Screening Service, Ireland
2 shared publications
Latest Publications
- 24 March 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (11) , 904-911
Adapting mammography DRLs for improved usability
Introduction: Dose audit and diagnostic reference levels should promote continuing optimization and patient protection. The objective of this work is to extend the diagnostic reference level concept by formulating benchmarks stratified by breast thickness and system type, and to make these benchmarks readily available to facilitate ongoing real-time audit. Materials and Method: After comparing the Facility diagnostic reference levels with the National one, the data set was divided into groups based on compressed breast thickness and system type. Benchmarks were established at the 95th percentile for individual categories, each combining a compressed breast thickness range with a system-type. Results: A Dose Management System was used to compare the median values of each individual system against the relevant benchmark. This enabled ongoing, pertinent comparisons of data in real-time. Conclusion: Comparison to the relevant benchmark helps to quickly identify systems requiring investigation and possible optimization. This transforms dose auditing into a proactive tool rather than a retrospective one.
- 24 March 2026
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 202 (11) , 904-911
Adapting mammography DRLs for improved usability
Introduction: Dose audit and diagnostic reference levels should promote continuing optimization and patient protection. The objective of this work is to extend the diagnostic reference level concept by formulating benchmarks stratified by breast thickness and system type, and to make these benchmarks readily available to facilitate ongoing real-time audit. Materials and Method: After comparing the Facility diagnostic reference levels with the National one, the data set was divided into groups based on compressed breast thickness and system type. Benchmarks were established at the 95th percentile for individual categories, each combining a compressed breast thickness range with a system-type. Results: A Dose Management System was used to compare the median values of each individual system against the relevant benchmark. This enabled ongoing, pertinent comparisons of data in real-time. Conclusion: Comparison to the relevant benchmark helps to quickly identify systems requiring investigation and possible optimization. This transforms dose auditing into a proactive tool rather than a retrospective one.
- 1 February 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (3) , 035009
A statistical alternative to current measures of image quality in digital mammography
Objective . Mammogram image quality in European breast screening systems is defined by threshold gold thickness ( T ) assessment of the CDMAM contrast-detail phantom. Previous studies have outlined several limitations of the phantom including expense, number of images required and inter-phantom manufacturing variability. Two alternative approaches to image quality assessment for routine quality control are examined and compared to the CDMAM technique: (i) A detectability index ( d ′) based on a non-prewhitened model observer with an eye filter (NPWE) an d (ii) A statistical estimate of contrast based on image noise levels ( C STAT ). Approach . The d ′ calculation follows a previously published methodology based on the NNPS and contrast, both measured from an image of 5 cm of PMMA containing a 0.2 mm Al target, as well as the MTF measured under standard conditions. For the proposed statistical method, pixels in the centre of the same NNPS image were re-binned into a range of equivalent CDMAM target areas. For any area, the minimum contrast necessary to distinguish a signal from the background, C STAT , is 3.29 σ at a 95% level of confidence, where σ is the standard deviation of the background pixels. Theoretical analysis predicts a simple relationships between C STAT , T and d ′. Measured values of C STAT were compared to T and d ′ as a function of air kerma at the detector for ten digital mammography systems from three different manufacturers. Main Results . Theoretical relationships between C STAT , d ′ and T were demonstrated. Minimum acceptable image quality performance for 0.10 and 0.25 mm diameter discs, defined by the European Guidelines in terms of T , are equivalent to d ′ values of 0.85 and 5.36 and threshold C STAT values of 0.055 and 0.022. Significance . Strong correlations between log( T ), log( d ′) and log( C STAT ) suggest that either alternative approach produces information corresponding to that obtained using the CDMAM. C STAT should be considered as a simple, objective and cost-effective alternative to routine image quality assessment in mammography.
- 1 February 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (3) , 035009
A statistical alternative to current measures of image quality in digital mammography
Objective . Mammogram image quality in European breast screening systems is defined by threshold gold thickness ( T ) assessment of the CDMAM contrast-detail phantom. Previous studies have outlined several limitations of the phantom including expense, number of images required and inter-phantom manufacturing variability. Two alternative approaches to image quality assessment for routine quality control are examined and compared to the CDMAM technique: (i) A detectability index ( d ′) based on a non-prewhitened model observer with an eye filter (NPWE) an d (ii) A statistical estimate of contrast based on image noise levels ( C STAT ). Approach . The d ′ calculation follows a previously published methodology based on the NNPS and contrast, both measured from an image of 5 cm of PMMA containing a 0.2 mm Al target, as well as the MTF measured under standard conditions. For the proposed statistical method, pixels in the centre of the same NNPS image were re-binned into a range of equivalent CDMAM target areas. For any area, the minimum contrast necessary to distinguish a signal from the background, C STAT , is 3.29 σ at a 95% level of confidence, where σ is the standard deviation of the background pixels. Theoretical analysis predicts a simple relationships between C STAT , T and d ′. Measured values of C STAT were compared to T and d ′ as a function of air kerma at the detector for ten digital mammography systems from three different manufacturers. Main Results . Theoretical relationships between C STAT , d ′ and T were demonstrated. Minimum acceptable image quality performance for 0.10 and 0.25 mm diameter discs, defined by the European Guidelines in terms of T , are equivalent to d ′ values of 0.85 and 5.36 and threshold C STAT values of 0.055 and 0.022. Significance . Strong correlations between log( T ), log( d ′) and log( C STAT ) suggest that either alternative approach produces information corresponding to that obtained using the CDMAM. C STAT should be considered as a simple, objective and cost-effective alternative to routine image quality assessment in mammography.
- 1 July 2021
- Published by Elsevier in European Journal of Radiology
- Vol. 140, 109751
Evaluation of microcalcification contrast in clinical images for digital mammography and synthetic mammography
- 1 July 2021
- Published by Elsevier in European Journal of Radiology
- Vol. 140, 109751
Evaluation of microcalcification contrast in clinical images for digital mammography and synthetic mammography
- 1 April 2021
- Published by Elsevier in Physica Medica
- Vol. 84, 289
Optimising Mammography Image Quality
- 1 April 2021
- Published by Elsevier in Physica Medica
- Vol. 84, 289
Optimising Mammography Image Quality
- 22 May 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11513, 115132I
Methodology for undertaking quality control testing of ghosting in digital breast tomosynthesis systems
Purpose: Low levels of ghosting are found during quality control of digital mammography (DM). In digital breast tomosynthesis (DBT) mode, the x-ray detector is not cleared during the series of exposures potentially leading to ghosting issues. Methods: The ghosting image factor (GIF) was calculated for systems from three manufacturers as follows. A 45 mm thick polymethyl methacrylate (PMMA) block covering half the detector was imaged, followed by the PMMA block plus 0.1 mm thick aluminium sheet centred on the block, this time positioned to fully cover the detector. This was undertaken for (1) DM and (2) between separate DBT scans. Inter-projection ghosting (3) was measured by moving the PMMA block from covering half the detector to covering the whole detector after the first projection. In method (4), a 3 mm thick aluminium plate with a 0.1 mm thick aluminium sheet on top was placed on the compression paddle at 100 mm above the breast covering half of the detector. Results: The GIF measured via test (1) and (2) was lower than the 0.3 tolerance set in the European guidelines for DM, however higher values were found for one system in DBT mode. Test 3, inter-projection GIF values were between 0.08 and 0.89, mostly above 0.3. Test 4 was a practical method and gave larger GIF values of between 1.07 and 8.01. Conclusions Ghosting factors measured between projections are considerably higher than the GIF measured between separate DBT scans. We propose a simple method using an aluminium plate to estimate the GIF.
- 22 May 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11513, 115132I
Methodology for undertaking quality control testing of ghosting in digital breast tomosynthesis systems
Purpose: Low levels of ghosting are found during quality control of digital mammography (DM). In digital breast tomosynthesis (DBT) mode, the x-ray detector is not cleared during the series of exposures potentially leading to ghosting issues. Methods: The ghosting image factor (GIF) was calculated for systems from three manufacturers as follows. A 45 mm thick polymethyl methacrylate (PMMA) block covering half the detector was imaged, followed by the PMMA block plus 0.1 mm thick aluminium sheet centred on the block, this time positioned to fully cover the detector. This was undertaken for (1) DM and (2) between separate DBT scans. Inter-projection ghosting (3) was measured by moving the PMMA block from covering half the detector to covering the whole detector after the first projection. In method (4), a 3 mm thick aluminium plate with a 0.1 mm thick aluminium sheet on top was placed on the compression paddle at 100 mm above the breast covering half of the detector. Results: The GIF measured via test (1) and (2) was lower than the 0.3 tolerance set in the European guidelines for DM, however higher values were found for one system in DBT mode. Test 3, inter-projection GIF values were between 0.08 and 0.89, mostly above 0.3. Test 4 was a practical method and gave larger GIF values of between 1.07 and 8.01. Conclusions Ghosting factors measured between projections are considerably higher than the GIF measured between separate DBT scans. We propose a simple method using an aluminium plate to estimate the GIF.
- 1 January 2020
- Published by Elsevier in Physica Medica
- Vol. 69, 262-268
Investigation of detector uniformity issues for Siemens Inspiration systems
- 1 January 2020
- Published by Elsevier in Physica Medica
- Vol. 69, 262-268
Investigation of detector uniformity issues for Siemens Inspiration systems
- 8 May 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (11) , 3015-3026
Quantitative analysis of the effect of energy separation in k-edge digital subtraction imaging
The aim of the work is to quantitatively compare the effect of the energy separation in the k-edge digital subtraction imaging technique. Images of a custom-made, iodine filled (k-edge = 33.17 keV) test object have been acquired with monochromatic x-ray beams (energy spread <0.1 keV) at the ID17 biomedical beamline of the ESRF. Image acquisition has been performed using two energy separations, namely 0.65 keV (32.85 keV and 33.5 keV, respectively) and 4.4 keV (31.2 keV and 35.6 keV, respectively), using beams of energies on either side of the iodine k-edge. Signal and signal-to-noise ratio (SNR) analysis has been performed as a function of DeltaE and the contrast medium concentrations. The results show that the SNR values measured for DeltaE < 1 keV are only slightly higher than those measured for DeltaE = 4.4 keV. This preliminary study shows that monochromaticity and the energy separation obtained with quasi monochromatic beams from conventional x-ray sources might be suitable for this imaging technique.
- 8 May 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (11) , 3015-3026
Quantitative analysis of the effect of energy separation in k-edge digital subtraction imaging
The aim of the work is to quantitatively compare the effect of the energy separation in the k-edge digital subtraction imaging technique. Images of a custom-made, iodine filled (k-edge = 33.17 keV) test object have been acquired with monochromatic x-ray beams (energy spread <0.1 keV) at the ID17 biomedical beamline of the ESRF. Image acquisition has been performed using two energy separations, namely 0.65 keV (32.85 keV and 33.5 keV, respectively) and 4.4 keV (31.2 keV and 35.6 keV, respectively), using beams of energies on either side of the iodine k-edge. Signal and signal-to-noise ratio (SNR) analysis has been performed as a function of DeltaE and the contrast medium concentrations. The results show that the SNR values measured for DeltaE < 1 keV are only slightly higher than those measured for DeltaE = 4.4 keV. This preliminary study shows that monochromaticity and the energy separation obtained with quasi monochromatic beams from conventional x-ray sources might be suitable for this imaging technique.
- 1 May 1998
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 409 (1-3) , 508-510
Image noise properties of a phosphor-coated CCD X-ray detector
- 1 May 1998
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 409 (1-3) , 508-510
Image noise properties of a phosphor-coated CCD X-ray detector