Faraz Fazal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Faraz Fazal has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Norbert Radacsi
School of Engineering, Institute for Materials and Processes The University of Edinburgh Edinburgh UK
5 shared publications - Vasileios Koutsos
School of Engineering, Institute for Materials and Processes The University of Edinburgh Edinburgh UK
4 shared publications - Anthony Callanan
University of Edinburgh
3 shared publications Andreia F. Silva
Edinburgh Complex Fluids Partnership (ECFP) SUPA and School of Physics & Astronomy The University of Edinburgh Peter Guthrie Tait Road Edinburgh EH9 3FD UK
2 shared publicationsAndrew McCormack
School of Engineering and Physical Sciences Institute of Biological Chemistry Biophysics and Bioengineering Heriot‐Watt University Edinburgh EH14 4AS UK
2 shared publications- Francisco Javier Diaz Sanchez
School of Engineering, Institute for Materials and Processes, The University of Edinburgh, Robert Stevenson Road, Edinburgh, EH9 3FB, United Kingdom
2 shared publications
Latest Publications
- Open Access
- 25 July 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 9 (23)
Fabrication of a Compliant Vascular Graft Using Extrusion Printing and Electrospinning Technique
Small‐diameter vascular grafts having biomechanical properties similar to those of native arteries for the treatment of cardiovascular diseases are still elusive. Here, a hybrid extrusion printing and electrospinning technique is presented in which a layer of electrospun nanofibers is deposited over the printed gelatin‐methacryloyl (gelMA) constructs to improve the mechanical performance of gelMA grafts. Various blends of polycaprolactone (PCL) and poly(L‐lactide‐co‐ε‐caprolactone) (PLCL) polymer solutions are used to produce electrospun nanofibers. The variation of gelMA concentration is found to have a negligible role in the overall strength of the graft. It is shown that the burst pressure and tensile strength of the fiber‐reinforced gelMA constructs are comparable to those of native human arteries. Moreover, the compliance of grafts reinforced by 100% PCL and 75/25% PCL/PLCL nanofibers are found to be similar to human muscular arteries and elastic arteries, respectively. The cytocompatibility assessment shows that gelMA presents a bioactive surface for the endothelial cells to survive and grow. Also, PCL/PLCL electrospun nanofibers offer cellular metabolic activity in the same order of magnitude as observed in the control. Therefore, this hybrid technique opens up new possibilities for the fabrication of tubular constructs in tissue engineering.
- 25 July 2024
- Published by Wiley in Advanced Materials Technologies
- Vol. 9 (23)
Open AccessFabrication of a Compliant Vascular Graft Using Extrusion Printing and Electrospinning Technique
Small‐diameter vascular grafts having biomechanical properties similar to those of native arteries for the treatment of cardiovascular diseases are still elusive. Here, a hybrid extrusion printing and electrospinning technique is presented in which a layer of electrospun nanofibers is deposited over the printed gelatin‐methacryloyl (gelMA) constructs to improve the mechanical performance of gelMA grafts. Various blends of polycaprolactone (PCL) and poly(L‐lactide‐co‐ε‐caprolactone) (PLCL) polymer solutions are used to produce electrospun nanofibers. The variation of gelMA concentration is found to have a negligible role in the overall strength of the graft. It is shown that the burst pressure and tensile strength of the fiber‐reinforced gelMA constructs are comparable to those of native human arteries. Moreover, the compliance of grafts reinforced by 100% PCL and 75/25% PCL/PLCL nanofibers are found to be similar to human muscular arteries and elastic arteries, respectively. The cytocompatibility assessment shows that gelMA presents a bioactive surface for the endothelial cells to survive and grow. Also, PCL/PLCL electrospun nanofibers offer cellular metabolic activity in the same order of magnitude as observed in the control. Therefore, this hybrid technique opens up new possibilities for the fabrication of tubular constructs in tissue engineering.
- Open Access
- 6 January 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 139, 105665
A vertical additive-lathe printing system for the fabrication of tubular constructs using gelatin methacryloyl hydrogel
- 6 January 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 139, 105665
Open AccessA vertical additive-lathe printing system for the fabrication of tubular constructs using gelatin methacryloyl hydrogel
- Open Access
- 28 June 2021
- Published by IOP Publishing in Biofabrication
- Vol. 13 (3) , 032003
Recent advancements in the bioprinting of vascular grafts
Recent advancements in the bioinks and three-dimensional (3D) bioprinting methods used to fabricate vascular constructs are summarized herein. Critical biomechanical properties required to fabricate an ideal vascular graft are highlighted, as well as various testing methods have been outlined to evaluate the bio-fabricated grafts as per the Food and Drug Administration (FDA) and International Organization for Standardization (ISO) guidelines. Occlusive artery disease and cardiovascular disease are the major causes of death globally. These diseases are caused by the blockage in the arteries, which results in a decreased blood flow to the tissues of major organs in the body, such as the heart. Bypass surgery is often performed using a vascular graft to re-route the blood flow. Autologous grafts represent a gold standard for such bypass surgeries; however, these grafts may be unavailable due to the previous harvesting or possess a poor quality. Synthetic grafts serve well for medium to large-sized vessels, but they fail when used to replace small-diameter vessels, generally smaller than 6 mm. Various tissue engineering approaches have been used to address the urgent need for vascular graft that can withstand hemodynamic blood pressure and has the ability to grow and remodel. Among these approaches, 3D bioprinting offers an attractive solution to construct patient-specific vessel grafts with layered biomimetic structures.
- 28 June 2021
- Published by IOP Publishing in Biofabrication
- Vol. 13 (3) , 032003
Open AccessRecent advancements in the bioprinting of vascular grafts
Recent advancements in the bioinks and three-dimensional (3D) bioprinting methods used to fabricate vascular constructs are summarized herein. Critical biomechanical properties required to fabricate an ideal vascular graft are highlighted, as well as various testing methods have been outlined to evaluate the bio-fabricated grafts as per the Food and Drug Administration (FDA) and International Organization for Standardization (ISO) guidelines. Occlusive artery disease and cardiovascular disease are the major causes of death globally. These diseases are caused by the blockage in the arteries, which results in a decreased blood flow to the tissues of major organs in the body, such as the heart. Bypass surgery is often performed using a vascular graft to re-route the blood flow. Autologous grafts represent a gold standard for such bypass surgeries; however, these grafts may be unavailable due to the previous harvesting or possess a poor quality. Synthetic grafts serve well for medium to large-sized vessels, but they fail when used to replace small-diameter vessels, generally smaller than 6 mm. Various tissue engineering approaches have been used to address the urgent need for vascular graft that can withstand hemodynamic blood pressure and has the ability to grow and remodel. Among these approaches, 3D bioprinting offers an attractive solution to construct patient-specific vessel grafts with layered biomimetic structures.
- 16 June 2021
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 94 (1) , 52-60
A modified 3D printer as a hybrid bioprinting-electrospinning system for use in vascular tissue engineering applications
There is a high demand for small diameter vascular grafts having mechanical and biological properties similar to that of living tissues. Tissue-engineered vascular grafts using current methods have often failed due to the mismatch of mechanical properties between the implanted graft and living tissues. To address this limitation, a hybrid bioprinting-electrospinning system is developed for vascular tissue engineering applications. The setup is capable of producing layered structure from electrospun fibres and cell-laden hydrogel. A Creality3D Ender 3D printer has been modified into a hybrid setup having one bioprinting head and two electrospinning heads. Fortus 250mc and Flashforge Creator Pro 3D printers were used to print parts using acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA) polymers. An Arduino mega 2560 and a Ramps 1.4 controller board were selected to control the functions of the hybrid bioprinting setup. The setup was tested successfully to print a tubular construct around a rotating needle.
- 16 June 2021
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 94 (1) , 52-60
A modified 3D printer as a hybrid bioprinting-electrospinning system for use in vascular tissue engineering applications
There is a high demand for small diameter vascular grafts having mechanical and biological properties similar to that of living tissues. Tissue-engineered vascular grafts using current methods have often failed due to the mismatch of mechanical properties between the implanted graft and living tissues. To address this limitation, a hybrid bioprinting-electrospinning system is developed for vascular tissue engineering applications. The setup is capable of producing layered structure from electrospun fibres and cell-laden hydrogel. A Creality3D Ender 3D printer has been modified into a hybrid setup having one bioprinting head and two electrospinning heads. Fortus 250mc and Flashforge Creator Pro 3D printers were used to print parts using acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA) polymers. An Arduino mega 2560 and a Ramps 1.4 controller board were selected to control the functions of the hybrid bioprinting setup. The setup was tested successfully to print a tubular construct around a rotating needle.
- 6 May 2021
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 92 (1) , 80-87
Design and development of a nozzle-free electrospinning device for the high-throughput production of biomaterial nanofibers
This technical note provides a step-by-step guide for the design and construction of a temperature-controlled nozzle-free electrospinning device. The equipment uses a rotating mandrel partially immersed within a polymer solution to produce fibers in an upward motion by inducing the formation of multiple Taylor cones and subsequently multi-jetting out of an electrified open surface. Free-surface electrospinning can overcome limitations and drawbacks associated with single and multi-nozzle spinneret configurations, such as low yield, limited production capacity, nonuniform electric field distribution, and clogging. Most importantly, this lab-scaled high-throughput device can provide an alternative economical route for needleless electrospinning research, in contrast to the high costs associated with industrially available upscaling equipment. Among the device's technical specifications, a key feature is a cryo-collector mandrel, capable of collecting fibers in sub-zero temperatures, which can induce ultra-porous nanostructures, wider pores, and subsequent in-depth penetration of cells. A multi-channel gas chamber allows the conditioning of the atmosphere, temperature, and airflow, while the chamber's design averts user exposure to the high-voltage components. All the Computer-Aided Design (CAD) files and point-by-point assembly instructions, along with a list of the materials used, are provided.
- 6 May 2021
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 92 (1) , 80-87
Design and development of a nozzle-free electrospinning device for the high-throughput production of biomaterial nanofibers
This technical note provides a step-by-step guide for the design and construction of a temperature-controlled nozzle-free electrospinning device. The equipment uses a rotating mandrel partially immersed within a polymer solution to produce fibers in an upward motion by inducing the formation of multiple Taylor cones and subsequently multi-jetting out of an electrified open surface. Free-surface electrospinning can overcome limitations and drawbacks associated with single and multi-nozzle spinneret configurations, such as low yield, limited production capacity, nonuniform electric field distribution, and clogging. Most importantly, this lab-scaled high-throughput device can provide an alternative economical route for needleless electrospinning research, in contrast to the high costs associated with industrially available upscaling equipment. Among the device's technical specifications, a key feature is a cryo-collector mandrel, capable of collecting fibers in sub-zero temperatures, which can induce ultra-porous nanostructures, wider pores, and subsequent in-depth penetration of cells. A multi-channel gas chamber allows the conditioning of the atmosphere, temperature, and airflow, while the chamber's design averts user exposure to the high-voltage components. All the Computer-Aided Design (CAD) files and point-by-point assembly instructions, along with a list of the materials used, are provided.