Verônica Ricken Marques
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Verônica Ricken Marques has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Antonio Belincanta
State University of Maringá, Civil Engineering Department, Maringá, Paraná, Brazil
1 shared publicationEwerton Guelssi
Presidente Castelo Branco’s City Hall, Castelo Branco, Paraná, Brazil
1 shared publicationHauke Zachert
Technical University Darmstadt, Institute and Laboratory for Geotechnics, Darmstadt, Germany
1 shared publicationJorge Luis Almada Augusto
State University of Londrina, Londrina, Paraná, Brazil
1 shared publicationMary-Antonette Beroya-Eitner
Technical University Darmstadt, Institute and Laboratory for Geotechnics, Darmstadt, Germany
1 shared publication
Latest Publications
- Open Access
- 26 April 2021
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 337, 03006
Effect of soil moisture content on the bearing capacity of small bored piles in the unsaturated soil of Maringá, Paraná, Brazil
In this study, the influence of soil moisture on the bearing capacity of piles founded in an unsaturated clay soil was investigated. The soil studied, composing the upper soil layer in Maringá, Brazil, is lateritic, has degree of saturation between 37% and 70% and has collapsible behaviour when wet. The bearing capacity was determined by full-scale load tests following the Brazilian Standard for Static Load Test. Two pile lengths, 4 m and 8 m, were considered. To analyse the influence of soil moisture, two tests were performed for each pile length: one in soil in its natural moisture content and another in pre-moistened soil. Results show that for both pile lengths, an increase in water content caused a significant reduction in bearing capacity, which is attributed to the decrease in the matric suction of the soil. This is confirmed by the results of the initial evaluation made on the variation of matric suction and its contribution to the bearing capacity with changes in water content. In summary, this study confirms that the pile bearing capacity in unsaturated soil is dependent on soil water content, highlighting the fact that the approach of assuming full saturation condition in the evaluation of the pile bearing capacity in such soil may give erroneous results. Moreover, this study demonstrate that the empirical methods most commonly used in Brazil for pile bearing capacity determination, the Décourt & Quaresma and Aoki & Velloso methods, are overly conservative when applied to the Maringá soil.
- 26 April 2021
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 337, 03006
Open AccessEffect of soil moisture content on the bearing capacity of small bored piles in the unsaturated soil of Maringá, Paraná, Brazil
In this study, the influence of soil moisture on the bearing capacity of piles founded in an unsaturated clay soil was investigated. The soil studied, composing the upper soil layer in Maringá, Brazil, is lateritic, has degree of saturation between 37% and 70% and has collapsible behaviour when wet. The bearing capacity was determined by full-scale load tests following the Brazilian Standard for Static Load Test. Two pile lengths, 4 m and 8 m, were considered. To analyse the influence of soil moisture, two tests were performed for each pile length: one in soil in its natural moisture content and another in pre-moistened soil. Results show that for both pile lengths, an increase in water content caused a significant reduction in bearing capacity, which is attributed to the decrease in the matric suction of the soil. This is confirmed by the results of the initial evaluation made on the variation of matric suction and its contribution to the bearing capacity with changes in water content. In summary, this study confirms that the pile bearing capacity in unsaturated soil is dependent on soil water content, highlighting the fact that the approach of assuming full saturation condition in the evaluation of the pile bearing capacity in such soil may give erroneous results. Moreover, this study demonstrate that the empirical methods most commonly used in Brazil for pile bearing capacity determination, the Décourt & Quaresma and Aoki & Velloso methods, are overly conservative when applied to the Maringá soil.