Peng Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peng Sun has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Chao Wang
College of Food Science, Heilongjiang Bayi Agricultural University, Daqing, China
6 shared publicationsShuo Li
Agricultural Products and Processed Products Supervision and Testing Center, Ministry of Agriculture, Daqing, China
5 shared publicationsNan Li
College of Food Science, Heilongjiang Bayi Agricultural University, Daqing, China
4 shared publicationsYuling Gao
Agricultural Products and Processed Products Supervision and Testing Center, Ministry of Agriculture, Daqing, China
4 shared publicationsRui Yan
Center of Management of Laboratory Equipment, Heilongjiang Bayi Agricultural University, Daqing 163319, China
2 shared publicationsXiaolin Zhang
Dalian Customs Technology Center
2 shared publications
Latest Publications
- 20 August 2026
- Published by Springer Nature in Food Analytical Methods
- Vol. 19 (10) , 317
Ultrasound-Assisted Supramolecular Deep Eutectic Solvent Extraction for HPLC–UV Determination of γ-Aminobutyric Acid in Tea
- 20 August 2026
- Published by Springer Nature in Food Analytical Methods
- Vol. 19 (10) , 317
Ultrasound-Assisted Supramolecular Deep Eutectic Solvent Extraction for HPLC–UV Determination of γ-Aminobutyric Acid in Tea
- 1 January 2025
- Published by Sociedade Brasileira de Quimica (SBQ) in Química Nova
IONIC LIQUID-BASED DISPERSIVE LIQUID-LIQUID MICROEXTRACTION FOLLOWED BY HPLC FOR THE DETERMINATION OF SIX EFFECTIVE COMPOSITION OF Silybum marianum
A novel pretreatment method ionic liquid-based dispersive liquid-liquid microextraction followed by high-performance liquid chromatography (HPLC) was established and applied in the analysis of silychristin, silydianin, silybin, silybin B, isosilybin A, isosilybin B in Silybum marianum. The critical parameters affecting dispersive liquid-liquid micro-extraction (DLLME), including selection of dispersive solvent and extraction solvent, volume of dispersive solvent and extraction solvent, adjustment of pH, salt concentration, extraction time, were investigated by single factor study. Under optimum conditions, all of the target analytes presented good linearity (r > 0.9991) and satisfied recoveries (recoveries > 89.5%, relative standard deviation (RSD) < 4.6%). The limits of detection and quantification were 0.16 to 0.74 ng kg–1 and 0.42 to 2.52 ng kg–1, respectively. The developed method is sensitive, rapid, accurate and employable to simultaneously determine six target compounds in Silybum marianum.
- 1 January 2025
- Published by Sociedade Brasileira de Quimica (SBQ) in Química Nova
IONIC LIQUID-BASED DISPERSIVE LIQUID-LIQUID MICROEXTRACTION FOLLOWED BY HPLC FOR THE DETERMINATION OF SIX EFFECTIVE COMPOSITION OF Silybum marianum
A novel pretreatment method ionic liquid-based dispersive liquid-liquid microextraction followed by high-performance liquid chromatography (HPLC) was established and applied in the analysis of silychristin, silydianin, silybin, silybin B, isosilybin A, isosilybin B in Silybum marianum. The critical parameters affecting dispersive liquid-liquid micro-extraction (DLLME), including selection of dispersive solvent and extraction solvent, volume of dispersive solvent and extraction solvent, adjustment of pH, salt concentration, extraction time, were investigated by single factor study. Under optimum conditions, all of the target analytes presented good linearity (r > 0.9991) and satisfied recoveries (recoveries > 89.5%, relative standard deviation (RSD) < 4.6%). The limits of detection and quantification were 0.16 to 0.74 ng kg–1 and 0.42 to 2.52 ng kg–1, respectively. The developed method is sensitive, rapid, accurate and employable to simultaneously determine six target compounds in Silybum marianum.
- Open Access
- 3 June 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (15) , 3635-3637
Correction to: Supramolecular deep eutectic solvent: a powerful tool for pre‑concentration of trace metals in edible oil
- 3 June 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (15) , 3635-3637
Open AccessCorrection to: Supramolecular deep eutectic solvent: a powerful tool for pre‑concentration of trace metals in edible oil
- 1 May 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (15) , 3533-3542
Supramolecular deep eutectic solvent: a powerful tool for pre-concentration of trace metals in edible oil
The utilization of supramolecular deep eutectic solvent eddy-assisted liquid–liquid microextraction utilizing 2-hydroxypropyl β-cyclodextrin (SUPRADES) has been identified as a successful method for pre-enriching Cu, Zn, and Mn in vegetable oil samples. Determination of each element was conducted by inductively coupled plasma optical emission spectrometry (ICP-OES) after digestion of metal-enriched phases. Various parameters were examined, including the composition of SUPRADES species [2HP-β-CD: DL-lactic acid], a cyclodextrin mass ratio of 20 wt%, a water bath temperature of 75 °C, an extractor volume of 800 μL, a dispersant volume of 50 μL, and an eddy current time of 5 min. Optimal conditions resulted in extraction rates of 99.6% for Cu, 105.2% for Zn, and 101.5% for Mn. The method exhibits a broad linear range spanning from 10 to 20,000 μg L−1, with determination coefficients exceeding 0.99 for all analytes. Enrichment coefficients of 24, 21, and 35 were observed. Limits of detection ranged from 0.89 to 1.30 μg L−1, while limits of quantification ranged from 3.23 to 4.29 μg L−1. The unique structural characteristics of the method enable the successful determination of trace elements in a variety of edible vegetable oils. Graphical abstract
- 1 May 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (15) , 3533-3542
Supramolecular deep eutectic solvent: a powerful tool for pre-concentration of trace metals in edible oil
The utilization of supramolecular deep eutectic solvent eddy-assisted liquid–liquid microextraction utilizing 2-hydroxypropyl β-cyclodextrin (SUPRADES) has been identified as a successful method for pre-enriching Cu, Zn, and Mn in vegetable oil samples. Determination of each element was conducted by inductively coupled plasma optical emission spectrometry (ICP-OES) after digestion of metal-enriched phases. Various parameters were examined, including the composition of SUPRADES species [2HP-β-CD: DL-lactic acid], a cyclodextrin mass ratio of 20 wt%, a water bath temperature of 75 °C, an extractor volume of 800 μL, a dispersant volume of 50 μL, and an eddy current time of 5 min. Optimal conditions resulted in extraction rates of 99.6% for Cu, 105.2% for Zn, and 101.5% for Mn. The method exhibits a broad linear range spanning from 10 to 20,000 μg L−1, with determination coefficients exceeding 0.99 for all analytes. Enrichment coefficients of 24, 21, and 35 were observed. Limits of detection ranged from 0.89 to 1.30 μg L−1, while limits of quantification ranged from 3.23 to 4.29 μg L−1. The unique structural characteristics of the method enable the successful determination of trace elements in a variety of edible vegetable oils. Graphical abstract
- 8 December 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (4) , 873-882
Vortex-assisted hydrophobic natural deep eutectic solvent liquid-liquid microextraction for the removal of silver ions from environmental water
This study presents a novel approach for the quantification of silver ions in environmental water through the utilization of liquid-liquid microextraction, employing natural deep eutectic solvents in conjunction with inductively coupled plasma emission spectroscopy. The extracted solvent was characterized by Fourier transform infrared spectroscopy (FT-IR). The impact of various extractant types, extractant molar ratio, extractant volume, extraction time, and salt concentration on the efficacy of silver ion extraction was investigated. The findings indicate that the optimal extraction efficiency was attained by utilizing a 5-mL aqueous solution volume, containing 1000 μL thymol/lactic acid NADES 1:3, a salt concentration of 1 mg mL−1, a pH value of 4, and a vortex time of 4 min. Upon implementing the optimized experimental conditions, the recovery of target metal ions was from 96.9 to 101.0%. The relative standard deviations were observed to be within the range of 1.5 to 2.7%. The present study demonstrates the reproducibility, accuracy, and reliability of the method for detecting silver ions in environmental water, with linear range of 5~1000 ng mL−1 and limits of detection (LOD) and limits of quantification (LOQ) of 1.52 ng mL−1 and 5.02 ng mL−1, respectively. Graphical Abstract
- 8 December 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (4) , 873-882
Vortex-assisted hydrophobic natural deep eutectic solvent liquid-liquid microextraction for the removal of silver ions from environmental water
This study presents a novel approach for the quantification of silver ions in environmental water through the utilization of liquid-liquid microextraction, employing natural deep eutectic solvents in conjunction with inductively coupled plasma emission spectroscopy. The extracted solvent was characterized by Fourier transform infrared spectroscopy (FT-IR). The impact of various extractant types, extractant molar ratio, extractant volume, extraction time, and salt concentration on the efficacy of silver ion extraction was investigated. The findings indicate that the optimal extraction efficiency was attained by utilizing a 5-mL aqueous solution volume, containing 1000 μL thymol/lactic acid NADES 1:3, a salt concentration of 1 mg mL−1, a pH value of 4, and a vortex time of 4 min. Upon implementing the optimized experimental conditions, the recovery of target metal ions was from 96.9 to 101.0%. The relative standard deviations were observed to be within the range of 1.5 to 2.7%. The present study demonstrates the reproducibility, accuracy, and reliability of the method for detecting silver ions in environmental water, with linear range of 5~1000 ng mL−1 and limits of detection (LOD) and limits of quantification (LOQ) of 1.52 ng mL−1 and 5.02 ng mL−1, respectively. Graphical Abstract
- Open Access
- 23 September 2022
- Published by Springer Nature in Research Square
Ionic liquid-based dispersive liquid-liquid followed high-performance liquid chromatography for the determination of Silychristin, Silydianin, Silybin, Silybin B, Isosilybin A, Isosilybin B in silbbum marianum seed
A novel pretreatment method ionic liquid-based dispersive liquid-liquid followed high-performance liquid chromatography was established and applied in the analysis of Silychristin, Silydianin, Silybin ,Silybin B, Isosilybin A, Isosilybin B in silbbum marianum. The critical parameters affecting dispersive liquid-liquid micro-extraction (DLLME), including selection of dispersive solvent and extraction solvent, volume of dispersive solvent and extraction solvent, adjustment of pH, salt concentration, extraction time, were investigated by single factor study. Under optimum conditions, all of the target analytes presented good linearity (r > 0.9991) and satisfied recoveries (Recoveries > 89.5%, relative standard deviation (RSD) < 4.6%). The limits of detection and quantification were 0.16 to 0.74 ng kg− 1 and 0.42 to 2.52 ng kg− 1, respectively. The developed method is sensitive, rapid, accurate and employable to simultaneously determine six target compounds in silbbum marianum.
- 23 September 2022
- Published by Springer Nature in Research Square
Open AccessIonic liquid-based dispersive liquid-liquid followed high-performance liquid chromatography for the determination of Silychristin, Silydianin, Silybin, Silybin B, Isosilybin A, Isosilybin B in silbbum marianum seed
A novel pretreatment method ionic liquid-based dispersive liquid-liquid followed high-performance liquid chromatography was established and applied in the analysis of Silychristin, Silydianin, Silybin ,Silybin B, Isosilybin A, Isosilybin B in silbbum marianum. The critical parameters affecting dispersive liquid-liquid micro-extraction (DLLME), including selection of dispersive solvent and extraction solvent, volume of dispersive solvent and extraction solvent, adjustment of pH, salt concentration, extraction time, were investigated by single factor study. Under optimum conditions, all of the target analytes presented good linearity (r > 0.9991) and satisfied recoveries (Recoveries > 89.5%, relative standard deviation (RSD) < 4.6%). The limits of detection and quantification were 0.16 to 0.74 ng kg− 1 and 0.42 to 2.52 ng kg− 1, respectively. The developed method is sensitive, rapid, accurate and employable to simultaneously determine six target compounds in silbbum marianum.
- Open Access
- 3 August 2022
- Published by Springer Nature in Research Square
Determination of eight Sterols in Rapeseed by Accelerated Solvent Extraction Coupled with Gas Chromatography tandem Mass Spectrometry
For determination of cholesterol, cholestanol, rapeseed sterol, ergosterol, rapeseed sterol, stigmasterol-sitosterol, and stigmasterol in rapeseed, an accelerated solvent extraction followed gas chromatography-tandem mass spectrometry technique was developed. The sterols were isolated after derivatization and identified using accelerated solvent extraction coupled with gas chromatography-mass spectrometry (GC-MS/MS). The results revealed a good linear relationship between the peak area and the corresponding mass concentration of the eight sterols in the range of 2-1000 mg/L, with correlation coefficients all greater than 0.9991, detection limits of 1.12–1.61 mg/kg, and quantification limits of 3.73–5.41 mg/kg, spiked recovery determination ranging from 5 to 20 mg/kg.The average recoveries were 89.5-105.2% at mg/kg supplemental level, and the precision was lower than 5.0%. The developed method was efficient, simple and accurate, and suitable for qualitative and quantitative analysis of eight sterol compounds in rapeseed, providing a method for rapid determination of sterol compounds in rapeseed.
- 3 August 2022
- Published by Springer Nature in Research Square
Open AccessDetermination of eight Sterols in Rapeseed by Accelerated Solvent Extraction Coupled with Gas Chromatography tandem Mass Spectrometry
For determination of cholesterol, cholestanol, rapeseed sterol, ergosterol, rapeseed sterol, stigmasterol-sitosterol, and stigmasterol in rapeseed, an accelerated solvent extraction followed gas chromatography-tandem mass spectrometry technique was developed. The sterols were isolated after derivatization and identified using accelerated solvent extraction coupled with gas chromatography-mass spectrometry (GC-MS/MS). The results revealed a good linear relationship between the peak area and the corresponding mass concentration of the eight sterols in the range of 2-1000 mg/L, with correlation coefficients all greater than 0.9991, detection limits of 1.12–1.61 mg/kg, and quantification limits of 3.73–5.41 mg/kg, spiked recovery determination ranging from 5 to 20 mg/kg.The average recoveries were 89.5-105.2% at mg/kg supplemental level, and the precision was lower than 5.0%. The developed method was efficient, simple and accurate, and suitable for qualitative and quantitative analysis of eight sterol compounds in rapeseed, providing a method for rapid determination of sterol compounds in rapeseed.
- Open Access
- 19 March 2021
- Published by Akademiai Kiado Zrt. in Acta Chromatographica
- Vol. 33 (2) , 202-207
Determination of organochlorine pesticides in water using GC combined with dispersive solid-phase extraction with single-walled carbon nanotubes
Summary: In this study, single-walled carbon nanotubes (SWNTs) were used to determine organochlorine pesticides (chlorothalonil and pentachloronitrobenzene) in water using dispersive solid-phase extraction (DSPE), followed by gas chromatography (GC). The optimal adsorption conditions were determined by analyzing the effect of adsorbent dosage, adsorption time, eluent type and volume, and elution time. Under the optimal conditions, a good linearity was obtained at concentrations from 10 to 400 μg L−1 with correlation coefficients ranging from 0.9991 to 0.9986. The limits of detection (LOD) for the two organochlorine pesticides were 0.025 and 0.049 μg L−1, and the limits of quantification (LOQ) were 0.080 and 0.156 μg L−1, respectively. The accuracy of the proposed method was evaluated by measuring the recovery of the spiked samples, which ranged from 82.5% to 110.5% at spiking levels of 0.5–10 μg L−1 with relative standard deviations lower than 5.6% (n = 6). This method was successfully applied to determine the target analytes in canal water, drinking water, and water taken from the inlets and outlets of a wastewater treatment plant. The results demonstrate that the developed method has great potential for determining the two organochlorine pesticides in water samples.
- 19 March 2021
- Published by Akademiai Kiado Zrt. in Acta Chromatographica
- Vol. 33 (2) , 202-207
Open AccessDetermination of organochlorine pesticides in water using GC combined with dispersive solid-phase extraction with single-walled carbon nanotubes
Summary: In this study, single-walled carbon nanotubes (SWNTs) were used to determine organochlorine pesticides (chlorothalonil and pentachloronitrobenzene) in water using dispersive solid-phase extraction (DSPE), followed by gas chromatography (GC). The optimal adsorption conditions were determined by analyzing the effect of adsorbent dosage, adsorption time, eluent type and volume, and elution time. Under the optimal conditions, a good linearity was obtained at concentrations from 10 to 400 μg L−1 with correlation coefficients ranging from 0.9991 to 0.9986. The limits of detection (LOD) for the two organochlorine pesticides were 0.025 and 0.049 μg L−1, and the limits of quantification (LOQ) were 0.080 and 0.156 μg L−1, respectively. The accuracy of the proposed method was evaluated by measuring the recovery of the spiked samples, which ranged from 82.5% to 110.5% at spiking levels of 0.5–10 μg L−1 with relative standard deviations lower than 5.6% (n = 6). This method was successfully applied to determine the target analytes in canal water, drinking water, and water taken from the inlets and outlets of a wastewater treatment plant. The results demonstrate that the developed method has great potential for determining the two organochlorine pesticides in water samples.