  • A Compact, Low-Cost, Highly Sensitive and High Speed Fiber Optic Vibration Sensor Based on Liquid Mass Block

    by Shuang Zeng, Jun-Hao Zhao, Hui Huang, Wei-Cheng Cai, Tao Sun, Jian-Wei Zhang, Peng-Bo Liu, Jian Zhao, Qing-Xin Wu, Jing Chen

    Currently, for fiber optic vibration sensors (FOVS), realizing high sensitivity (sub-μg) and high speed (~ kHz) simultaneously is still a challenge. Herein, a high speed and highly sensitive FOVS was demonstrated by using the liquid mass block (silicone oil), which can transmit the inertial force to all the direction inside the FOVS for omnidirectional sensing. Owing to the liquid nature of oil, the inertial force can be uniformly applied on the diaphragm without deteriorating its mechanical properties. The response magnitude of FOVS can be enhanced ~48 dB by employing the liquid mass block. Moreover, because without using any optical interference effect, precise control on the light wavelength and cavity length is no longer needed, which simplifies sensor fabrication and demodulation system for compact and low cost. An omnidirectional detection limit of 0.1 μg, a sensitivity of 3.2 V/g, and a resonance frequency of 2.7 kHz was realized for the FOVS.


  • A Compact and Sensitive Metal-Capillary Fluorometer: Application to Online Monitoring Oil Spill

    by Zhaolin Li, Pengcheng Sun, Hui Huang, Weicheng Cai, Xiaozheng Jiang, Pei Guo, Jianchao Fan, Shuo Zhang, Jing Chen, Jien Song, et al.

    Due to the frequent occurrence of marine oil spill accidents and related ecological pollution, online detection of oil-slick thickness is important. Fluorescence detection of oil slick has the advantages of high sensitivity and no need of reagent. Herein, a compact and sensitive fluorometer consisted of two metal capillary (MC), a UV LED and a linear variable filter (LVF), was developed for oil slick detection in a non-contact way. The two MCs are used to transmit UV light and collect fluorescence above the oil slick, respectively, and the angle between them is 45 degrees (V-shaped MCs). By employing MCs, the detection signal-to-noise ratio (SNR) can be improved by 34.5 times, and the limit of detection (LOD) of oil slick thickness is as low as 0.035 µm. The relationship between the fluorescence signal and the oil slick thickness features good linearity (R2 = 0.998) in a range of 0.035 ~ 20 µm. The spectrometer would be suitable for online monitoring marine oil spill.


  • A High-Sensitivity and Low-Cost Turbidimeter Based on Metal Capillary Cavity

    by Xuejing Li, Jianwei Zhang, Hui Huang, Weicheng Cai, Jian Zhao, Pengbo Liu, Yajun Wu, Mingchang Liu, Jing Chen

    Clean water is important for human health, but commercial turbidimeter with high sensitivity (detection limit <0.01 NTU) is still lack. Herein, a high-sensitivity and low-cost turbidimeter based on metal capillary cavity (MCC), which consists of a metal capillary and two apertured mirrors, was proposed. In order to improve the detection limit, the signal-to-noise ratio (SNR) need to be improved by optimizing the aperture size of MCC, since there is a trade-off between optical path and light intensity received by the detector, e.g., smaller aperture can increase optical path, but it would reduce light intensity received by the detector. The optimal aperture radius of 0.15 mm was obtained by experiments. The turbidimeter was used to measure formazine turbidity solution, and a detection limit of 0.001 NTU was realized, which is more than 3.6-fold lower than that of previous reports and commercial turbidimeters. The turbidimeter features compact structure, high sensitivity and low cost.


  • Compact Fluorescence Spectrometer with Built-In In-Line Calibration: Application to Detect Dissolved Organic Matter in Water

    by Weicheng Cai, Hui Huang, Zhaolin Li, Xuejing Li, Jianchao Fan, Shuo Zhang, Guojin Feng, Jing Chen

    Fluorescence spectrometry (FS) is widely used for component analysis because each fluorescing material has its own characteristic spectrum. However, the spectral calibration is complicated and bulky. Herein, an in-line spectral calibration sheet (ISCS) was proposed in which a narrow band-pass filter and a linear variable filter (LVF) were integrated on a metal plate. By moving the ISCS, the transmitted excitation light power (TEP) as well as fluorescence spectrum can be seamlessly scanned, and the TEP can be used for in-line spectral calibration. A compact FS device is based on UV-LED excitation and metal capillary (MC), and ISCS was fabricated (i.e., ISCS-FS) and applied to detect sodium humate in water. By employing TEP calibration, both the primary inner filter effect (PIFE) and the drift in the optical power of UV-LED can be simultaneously compensated. The linear correlation coefficient of signal concentration was improved from 0.89 to 0.998, and the relative standard deviation (RSD) of replicated detection was improved from 3 to 0.7%. A DLC of 1.3 mu g/L was realized, which is 15-fold lower than that of a commercial FS device (20 mu g/L). The DLC is even comparable with that (0.5-4 mu g/L) of commercial total organic carbon (TOC) analyzers, which are bulky and expensive. The linear correlation between the measurement results of ISCS-FS and commercial TOC analyzers can reach a good value of 0.94.


  • A Compact UV-LED-Induced Fluorescence With Short Metal Capillary and Low Light Leakage: Application to Noninvasive Glucose Detection

    by Weicheng Cai, Zhaolin Li, Hui Huang, Xuejing Li, Jian Zhao, Pengbo Liu, Yajun Wu, Mingchang Liu, Jian Wang

    Laser induced fluorescence (LIF) is one of the most sensitive techniques for detection. As for the LIF with UV excitation, replacing UV laser with UV LED (i.e., UV LED-IF) has advantages of long life time and low cost. However, for LED-IF, the background signal (noise) would be much higher, due to the poor beam-quality of LED. Herein, an axial-excitation UV LED-IF with short metal capillary (MC) and black sealing (i.e., MC-LED-IF) was proposed for noninvasive detection of human saliva glucose (HSG). The SNR was improved 3.1 fold by employing the black sealing, owing to the effective suppression of the background signal, which mainly results from light leakage. Moreover, transmission loss of UV LED light in MC and saliva filled MC was investigated, and an optimal MC length of only 4 cm was obtained. By using the MC-LED-IF, a DLC of 2.4 μM was realized for detecting HSG via conventional HPPA reagent with good selectivity and reliability. The MC-LED-IF features low cost and compact (11×4×4 cm 3 ), which is suitable for personal use.


  • Highly Sensitive and Selective Photoelectrochemical Aptasensors for Cancer Biomarkers Based on MoS2/Au/GaN Photoelectrodes

    by Danli Hu, Haiyan Cui, Xinyang Wang, Fang Luo, Bin Qiu, Weicheng Cai, Hui Huang, Jian Wang, Zhenyu Lin

    An Au/GaN photoelectrode was prepared by sputtering 30 nm thick Au film on the surface of n-type gallium nitride (GaN). When the electrode contacts with multilayered molybdenum disulfide (MoS2), photogenerated electrons and photogenerated holes transfer to MoS2 because of the band gap matching of MoS2 and GaN. The presence of Au promotes charge transfer and results in a greater recombination of electrons and holes; by this means, a more significant suppression of photocurrent can be detected. This characteristic has been coupled with the high selectivity of an aptamer and applied to develop a novel photoelectrochemical aptasensor for cancer biomarkers (alpha-fetoprotein (AFP) as a model). The aptamer of AFP was modified on the surface of the Au/GaN photoelectrode by Au–S bonds, which can bind to the target protein with high selectivity. Then, the transfer process of the charge carriers of GaN to MoS2 can be blocked by the target protein so that the suppression of photocurrent is reduced. The difference of the photocurrent in the presence and absence of AFP (ΔI) showed a linear relationship with AFP concentration that ranged from 1.0–150 ng/mL (R2 = 0.9995), and the detection limit was 0.3 ng/mL. The standard addition recovery rates ranged from 85.2 to 91.7%. The method possessed good sensitivity and high selectivity for AFP detection. The developed biosensor can be modified to detect other cancer biomarkers by simply replacing the aptamer used.