PGPilar Garrido

Pilar Garrido

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pilar Garrido has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mitral regurgitation caused by perforation of a pseudoaneurysm of the mitral-aortic intervalvular fibrosa

    by Juan Lacalzada-Almeida, Pilar Garrido, Flor Baeza-Garzón, María Manuela Izquierdo-Gómez

    A 68-year-old male patient with ex-alcoholic and liver transplantation was admitted with heart failure. Two months earlier, he had been admitted for cholangitis, with positive blood cultures for Escherichia coli, and the possibility of infectious endocarditis (IE) was not suspected. On admission, the patient was afebrile, with heart failure signs and a newly appearing apical pansystolic murmur. Blood cultures were negative. A transthoracic echocardiogram (TTE) showed a severe mitral regurgitation (MR) jet originating from the mitral-aortic intervalvular fibrosa (MAIVF) ( Supplementary material online, Figure S1 and Video 1). A transoesophageal echocardiogram (TOE) confirmed the existence of a pseudoaneurysm of the MAIVF (P-MAIVF), posterior to the left coronary and non-coronary sinuses, with a fistula connecting with the left atrium (LA) causing severe MR (Figure 1 and Videos 2 and 3). A three-dimensional (3D) TOE showed a perforation in the P-MAIVF followed by severe regurgitation from the left ventricular outflow tract (LVOT) to the LA (Figure 2 and Supplementary material online, Video S1 ). A cardiac computed tomography angiography (CCTA) confirmed the finding of a P-MAIVF with a connection neck with the LVOT ( Supplementary material online, Figures S2–S4 and Video S2). Transthoracic echocardiogram allowed the diagnosis of MR with a non-commissural regurgitant orifice origin. Transoesophageal echocardiogram two-dimensional determined the mechanism of this MR, a P-MAIVF with a fistula towards LA. The use of 3D TOE visualized the fistula entrance orifice in the LA and its anatomical position regarding to the aortic valve and the P-MAIVF. Finally, CCTA established the size and diameter of the neck of the P-MAIVF, as well as its position between the LVOT and the LA. The patient underwent cardiac surgery with mitral and aortic valve replacement ( Supplementary material online, Figure S5 ) but he died due to low cardiac output within a few hours after surgery.

  • Open Access

    Impact of bendopnea on postoperative outcomes in patients with severe aortic stenosis undergoing aortic valve replacement

    by Alberto Dominguez-Rodriguez, Jennifer T Thibodeau, Colby R Ayers, Alejandro Jimenez-Sosa, Pilar Garrido, Javier Montoto, Pablo C Prada-Arrondo, Pedro Abreu-Gonzalez, Mark H Drazner

    Bendopnea is a recently described symptom of advanced heart failure. Its prevalence and prognostic utility in other cardiac conditions are unknown. We prospectively enrolled 108 consecutive patients (75 ± 3 years, 68% men) with severe symptomatic aortic stenosis referred for surgical aortic valve replacement (SAVR). Preoperatively, patients were tested for bendopnea, which was considered to be present when dyspnoea occurred within 30 s of bending forward. Univariable and stepwise multivariable analyses tested the association of bendopnea with preoperative echocardiographic parameters and postoperative clinical outcomes. Bendopnea was present in 46 of 108 (42%) patients. The mean time of onset was 10.5 ± 3.4 s. Bendopnea was associated with higher estimated pulmonary artery systolic pressures [51 (11) mmHg vs 40 (11) mmHg), P < 0.0001], smaller aortic valve area [0.66 (0.16) cm2 vs 0.76 (0.13) cm2, P = 0.0006] and longer duration of mechanical ventilation (P = 0.002) and length of stay in the hospital (P = 0.007). Following SAVR, in-hospital mortality in those with bendopnea versus those without bendopnea was 13% vs 3% (P = 0.07). In multivariable analysis, bendopnea was associated with duration of mechanical ventilation (parameter estimate 2.4, P < 0.0001) and length of stay in the hospital (parameter estimate 10.2, P ≤ 0.0001). Bendopnea was present in a sizeable minority of patients (42%) with severe aortic stenosis referred for SAVR. Bendopnea was associated with higher pulmonary artery systolic pressure and smaller aortic valve area preoperatively and with longer duration of mechanical ventilation and length of hospitalization postoperatively. These data suggest that bendopnea provides prognostic information in patients with severe aortic stenosis undergoing SAVR.


  • Open Access

    The effect of intravenous and oral iron administration on perioperative anaemia and transfusion requirements in patients undergoing elective cardiac surgery: a randomized clinical trial

    by Pilar Garrido-Martín, Mohamed Ibrahim Nassar-Mansur, Ramiro de la Llana-Ducrós, Tirso Mª Virgos-Aller, Patricia María Rodríguez Fortunez, Rosa Ávalos-Pinto, Alejandro Jimenez-Sosa, Rafael Martínez-Sanz

    Anaemia is a frequent complication after cardiopulmonary bypass surgery. Iron therapy has been variably employed by medical centres over the years. In our study we test o test the clinical effectiveness of intravenous and oral iron supplementation in correcting anaemia, and its impact on blood transfusion requirements, in patients undergoing cardiopulmonary bypass surgery. A double-blind, randomized, placebo-controlled clinical trial with three parallel groups of patients. Group I (n = 54): intravenous iron(III)-hydroxide sucrose complex, three doses of 100 mg/24 h during pre- and postoperative hospitalization and 1 pill/24 h of oral placebo in the same period and during 1 month after discharge. Group II (n = 53): oral ferrous fumarate iron 1 pill/24 h pre- and postoperatively and during 1 month after discharge, and intravenous placebo while hospitalized. Group III (n = 52): oral and intravenous placebo pre- and postoperatively, following the same protocol. Data were collected preoperatively, at theatre, at intensive care unit admission, before hospital discharge and 1 month later. (1) Baseline clinical and demographic characteristics and surgical procedures were similar in the three groups; (2) no inter-group differences were found in haemoglobin and haematocrit during the postoperative period; (3) the intravenous iron group showed higher serum ferritin levels at hospital discharge (1321 ± 495 ng/ml; P < 0.001) and 1 month later (610 ± 387; P < 0.001) compared with the other groups and (4) we did not observe statistical differences in blood transfusion requirements between the three groups. The use of intravenous or oral iron supplementation proved ineffective in correcting anaemia after cardiopulmonary bypass and did not reduce blood transfusion requirements. [Current Controlled Trials number: NCT01078818 (oral and intravenous iron in patients postoperative cardiovascular surgery under EC)].