Caio Henrique Marques Texeira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Caio Henrique Marques Texeira has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Juliana Maria Ferraz Sallum
Department of Ophthalmology and Visual Sciences, Universidade Federal de São Paulo
5 shared publications - Mariana Matioli da Palma
Universidade Federal de São Paulo, Escola Paulista de Medicina
3 shared publications - Adriana Berezovsky
Universidade Federal de São Paulo
2 shared publications - Amanda Amorim Rodrigues
Departamento de Oftalmologia e Ciências Visuais Escola Paulista de Medicina Universidade Federal de São Paulo São Paulo SP Brazil
2 shared publications - Gabriela Doná Rodrigues
Escola Paulista de Medicina
2 shared publications - Huber Martins Vasconcelos
Escola Paulista de Medicina
2 shared publications
Latest Publications
- 24 June 2026
- Published by Taylor & Francis in Ophthalmic Genetics
- p. 1-7
Ora visual navigation course™ mobility test results in two individuals with CEP290 LCA after intravitreal injection of antisense oligonucleotide
This study aimed to report the longitudinal Ora Visual Navigation Course (Ora VNC™) mobility test results in two individuals, with CEP290 LCA following intravitreal injections of an antisense oligonucleotide, sepofarsen. Two individuals were enrolled in the Illuminate Phase 3 trial and subsequently in the Post-Trial Access (PTA) program, undergoing Ora VNC™ across 12 visits. Subject 1 was initially randomized to the control (sham) group and switched to treatment from control group from the month 12 visit onwards. This individual passed only a few courses but demonstrated signs of enhanced spatial perception (defined by, among others, the ability to perceive objects' shapes and sizes). FST (full-field stimulus threshold) supported the light sensitivity gain in this subject. In contrast, subject 2, who received treatment since baseline visit, successfully completed mobility tests in all visits with progressive improvement, reaching lower luminance and more challenging contrast settings over time. According to the technicians' report, both subjects demonstrated an increase in perceived obstacle recognition during iterations, which may reflect improvement of mobility-based visual function outcomes. The Ora VNC™ mobility test captured mobility-based visual function gains, including subtle spatial improvements, but may lack sensitivity in individuals with extremely low vision, potentially overlooking small but patient-relevant changes.
- 24 June 2026
- Published by Taylor & Francis in Ophthalmic Genetics
- p. 1-7
Ora visual navigation course™ mobility test results in two individuals with CEP290 LCA after intravitreal injection of antisense oligonucleotide
This study aimed to report the longitudinal Ora Visual Navigation Course (Ora VNC™) mobility test results in two individuals, with CEP290 LCA following intravitreal injections of an antisense oligonucleotide, sepofarsen. Two individuals were enrolled in the Illuminate Phase 3 trial and subsequently in the Post-Trial Access (PTA) program, undergoing Ora VNC™ across 12 visits. Subject 1 was initially randomized to the control (sham) group and switched to treatment from control group from the month 12 visit onwards. This individual passed only a few courses but demonstrated signs of enhanced spatial perception (defined by, among others, the ability to perceive objects' shapes and sizes). FST (full-field stimulus threshold) supported the light sensitivity gain in this subject. In contrast, subject 2, who received treatment since baseline visit, successfully completed mobility tests in all visits with progressive improvement, reaching lower luminance and more challenging contrast settings over time. According to the technicians' report, both subjects demonstrated an increase in perceived obstacle recognition during iterations, which may reflect improvement of mobility-based visual function outcomes. The Ora VNC™ mobility test captured mobility-based visual function gains, including subtle spatial improvements, but may lack sensitivity in individuals with extremely low vision, potentially overlooking small but patient-relevant changes.
- 16 June 2026
- Published by Taylor & Francis in Ophthalmic Genetics
- p. 1-8
Microperimetry is a valuable tool for assessing changes in visual function following voretigene neparvovec-rzyl gene therapy
Gene therapy with voretigene neparvovec-rzyl was approved primarily based on improvements observed in the Multi-Luminance Mobility Test (MLMT), while the full-field stimulus threshold (FST) test, a secondary endpoint, also demonstrated efficacy. However, the MLMT is difficult to apply in routine practice, and the FST does not provide spatial information regarding retinal function, which limits direct structural-function correlation. Therefore, this study investigated whether microperimetry could serve as a simpler, more practical alternative by evaluating its changes after this gene therapy. Mean sensitivity and fixation parameters were evaluated in a cohort of 5 patients (10 eyes) who underwent microperi-metry following gene therapy in São Paulo, Brazil. Results demonstrated a significant increase in mean sensitivity (MS, p = 0.0006) and a better perception of dimmer stimuli (p = 0.0004), indicating higher sensitivity. Results from individual eyes showed consistent improvements in retinal sensitivity and fixation stability. These findings were consistent with improvements in daily functioning-particularly in low-light conditions-reported by the patients during medical history assessment during the routine visits. Overall, the findings suggest that microperimetry could be an useful tool for monitoring functional outcomes after gene therapy.
- 16 June 2026
- Published by Taylor & Francis in Ophthalmic Genetics
- p. 1-8
Microperimetry is a valuable tool for assessing changes in visual function following voretigene neparvovec-rzyl gene therapy
Gene therapy with voretigene neparvovec-rzyl was approved primarily based on improvements observed in the Multi-Luminance Mobility Test (MLMT), while the full-field stimulus threshold (FST) test, a secondary endpoint, also demonstrated efficacy. However, the MLMT is difficult to apply in routine practice, and the FST does not provide spatial information regarding retinal function, which limits direct structural-function correlation. Therefore, this study investigated whether microperimetry could serve as a simpler, more practical alternative by evaluating its changes after this gene therapy. Mean sensitivity and fixation parameters were evaluated in a cohort of 5 patients (10 eyes) who underwent microperi-metry following gene therapy in São Paulo, Brazil. Results demonstrated a significant increase in mean sensitivity (MS, p = 0.0006) and a better perception of dimmer stimuli (p = 0.0004), indicating higher sensitivity. Results from individual eyes showed consistent improvements in retinal sensitivity and fixation stability. These findings were consistent with improvements in daily functioning-particularly in low-light conditions-reported by the patients during medical history assessment during the routine visits. Overall, the findings suggest that microperimetry could be an useful tool for monitoring functional outcomes after gene therapy.
- Top Cited PapersOpen Access
- 18 June 2025
- Published by Springer Nature in Nature Machine Intelligence
- Vol. 7 (6) , 967-978
Next-generation phenotyping of inherited retinal diseases from multimodal imaging with Eye2Gene
Rare eye diseases such as inherited retinal diseases (IRDs) are challenging to diagnose genetically. IRDs are typically monogenic disorders and represent a leading cause of blindness in children and working-age adults worldwide. A growing number are now being targeted in clinical trials, with approved treatments increasingly available. However, access requires a genetic diagnosis to be established sufficiently early. Critically, the timely identification of a genetic cause remains challenging. We demonstrate that a deep learning algorithm, Eye2Gene, trained on a large multimodal imaging dataset of individuals with IRDs (n = 2,451) and externally validated on data provided by five different clinical centres, provides better-than-expert-level top-five accuracy of 83.9% for supporting genetic diagnosis for the 63 most common genetic causes. We demonstrate that Eye2Gene’s next-generation phenotyping can increase diagnostic yield by improving screening for IRDs, phenotype-driven variant prioritization and automatic similarity matching in phenotypic space to identify new genes. Eye2Gene is accessible online (app.eye2gene.com) for research purposes.
- 18 June 2025
- Published by Springer Nature in Nature Machine Intelligence
- Vol. 7 (6) , 967-978
Top Cited PapersOpen AccessNext-generation phenotyping of inherited retinal diseases from multimodal imaging with Eye2Gene
Rare eye diseases such as inherited retinal diseases (IRDs) are challenging to diagnose genetically. IRDs are typically monogenic disorders and represent a leading cause of blindness in children and working-age adults worldwide. A growing number are now being targeted in clinical trials, with approved treatments increasingly available. However, access requires a genetic diagnosis to be established sufficiently early. Critically, the timely identification of a genetic cause remains challenging. We demonstrate that a deep learning algorithm, Eye2Gene, trained on a large multimodal imaging dataset of individuals with IRDs (n = 2,451) and externally validated on data provided by five different clinical centres, provides better-than-expert-level top-five accuracy of 83.9% for supporting genetic diagnosis for the 63 most common genetic causes. We demonstrate that Eye2Gene’s next-generation phenotyping can increase diagnostic yield by improving screening for IRDs, phenotype-driven variant prioritization and automatic similarity matching in phenotypic space to identify new genes. Eye2Gene is accessible online (app.eye2gene.com) for research purposes.
- Open Access
- 1 January 2025
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 88 (3) , 1-8
Multimodal imaging in retinitis pigmentosa related to the EYS gene
Purpose: This study aimed to characterize retinitis pigmentosa associated with the eyes shut homolog gene, which causes hereditary retinal degeneration. Methods: The anatomical and functional findings of retinitis pigmentosa in patients with variants of the eyes shut homolog gene were characterized and compared using multimodal imaging and genetic analysis of the variants. Clinical data such as visual acuity, lens status, and refraction were obtained from medical records. Patients underwent an ophthalmic examination, including static visual field, microperimetry, optical coherence tomography, fundus autofluorescence, and fundus photography. Results: Twenty-two patients were included in the study. Several anatomical and functional characteristics of retinitis pigmentosa-eyes shut homolog were identified, including the presence of cataracts, cystoid macular edema, epiretinal membrane, and a tubular visual field. Genetic results revealed 26 distinct variants in the cohort, with 7 novel variants not previously documented or reported in the scientific literature or databases. Conclusion: The findings demonstrate that eyes shut homolog-retinitis pigmentosa manifests in specific patterns, starting in adolescence with mild progression and advancing with age. The integration of multimodal imaging and genetic analysis has provided a detailed understanding of the anatomical and functional features of retinitis pigmentosa-eyes shut homolog. Seven novel variants of the eyes shut homolog gene have been identified. These findings enhance the understanding of eyes shut homolog-related retinitis pigmentosa characteristics of by detailing the spectrum of mutations in this gene within the Brazilian population.
- 1 January 2025
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 88 (3) , 1-8
Open AccessMultimodal imaging in retinitis pigmentosa related to the EYS gene
Purpose: This study aimed to characterize retinitis pigmentosa associated with the eyes shut homolog gene, which causes hereditary retinal degeneration. Methods: The anatomical and functional findings of retinitis pigmentosa in patients with variants of the eyes shut homolog gene were characterized and compared using multimodal imaging and genetic analysis of the variants. Clinical data such as visual acuity, lens status, and refraction were obtained from medical records. Patients underwent an ophthalmic examination, including static visual field, microperimetry, optical coherence tomography, fundus autofluorescence, and fundus photography. Results: Twenty-two patients were included in the study. Several anatomical and functional characteristics of retinitis pigmentosa-eyes shut homolog were identified, including the presence of cataracts, cystoid macular edema, epiretinal membrane, and a tubular visual field. Genetic results revealed 26 distinct variants in the cohort, with 7 novel variants not previously documented or reported in the scientific literature or databases. Conclusion: The findings demonstrate that eyes shut homolog-retinitis pigmentosa manifests in specific patterns, starting in adolescence with mild progression and advancing with age. The integration of multimodal imaging and genetic analysis has provided a detailed understanding of the anatomical and functional features of retinitis pigmentosa-eyes shut homolog. Seven novel variants of the eyes shut homolog gene have been identified. These findings enhance the understanding of eyes shut homolog-related retinitis pigmentosa characteristics of by detailing the spectrum of mutations in this gene within the Brazilian population.
- Open Access
- 1 January 2025
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 88 (2) , 1-7
Perception and satisfaction of blind individuals regarding an electronic cane prototype with a wearable haptic device
Purpose: This study aimed to evaluate the perception and degree of satisfaction of blind individuals regarding an electronic cane prototype with a wearable haptic interface. Methods: Two scenarios with different obstacles were created to conduct tests with the canes (the user’s cane and the prototype one). The perception and satisfaction of participants regarding the electronic cane were assessed using a questionnaire, the number of collisions during the tests, and the time each individual took to complete the course in each scenario. Results: Ten blind individuals who used the white cane participated in this study. Eight were males, and two were females. Their age ranged from 23 to 43 (average 32.3 ± 7.13 years and median 32 years). There was a tendency for fewer collisions with ground obstacles when the electronic cane was used than when the white cane was used. However, there was no statistically significant difference between the number of collisions and the course completion time in each scenario with either canes tested. Conclusion: Overall, the perception and satisfaction of individuals regarding the prototype used were positive.
- 1 January 2025
- Published by GN1 Sistemas e Publicacoes Ltd. in Arquivos Brasileiros de Oftalmologia
- Vol. 88 (2) , 1-7
Open AccessPerception and satisfaction of blind individuals regarding an electronic cane prototype with a wearable haptic device
Purpose: This study aimed to evaluate the perception and degree of satisfaction of blind individuals regarding an electronic cane prototype with a wearable haptic interface. Methods: Two scenarios with different obstacles were created to conduct tests with the canes (the user’s cane and the prototype one). The perception and satisfaction of participants regarding the electronic cane were assessed using a questionnaire, the number of collisions during the tests, and the time each individual took to complete the course in each scenario. Results: Ten blind individuals who used the white cane participated in this study. Eight were males, and two were females. Their age ranged from 23 to 43 (average 32.3 ± 7.13 years and median 32 years). There was a tendency for fewer collisions with ground obstacles when the electronic cane was used than when the white cane was used. However, there was no statistically significant difference between the number of collisions and the course completion time in each scenario with either canes tested. Conclusion: Overall, the perception and satisfaction of individuals regarding the prototype used were positive.
- Open Access
- 25 October 2023
- Published by Revista Brasileira de Oftalmologia in Revista Brasileira de Oftalmologia
- Vol. 82
Avaliação dos alunos deficientes visuais e videntes do Instituto de Cegos Padre Chico
RESUMO Objetivo Avaliar o perfil dos alunos concluintes, deficientes visuais e videntes do Instituto de Cegos Padre Chico entre os anos 2011 e 2020. Métodos Entre janeiro e março de 2021, foi realizada uma análise documental dos alunos concluintes entre os anos de 2011 e 2020. Foram coletados dados relacionados à situação social, educacional, socioeconômica e oftalmológica. Os dados foram tratados no programa Microsoft Excel 2013 da Microsoft e analisados no software livre Bioestat, versão 5.0. Resultados Foram coletados os [...] RESUMO Objetivo Avaliar o perfil dos alunos concluintes, deficientes visuais e videntes do Instituto de Cegos Padre Chico entre os anos 2011 e 2020. Métodos Entre janeiro e março de 2021, foi realizada uma análise documental dos alunos concluintes entre os anos de 2011 e 2020. Foram coletados dados relacionados à situação social, educacional, socioeconômica e oftalmológica. Os dados foram tratados no programa Microsoft Excel 2013 da Microsoft e analisados no software livre Bioestat, versão 5.0. Resultados Foram coletados os
- 25 October 2023
- Published by Revista Brasileira de Oftalmologia in Revista Brasileira de Oftalmologia
- Vol. 82
Open AccessAvaliação dos alunos deficientes visuais e videntes do Instituto de Cegos Padre Chico
RESUMO Objetivo Avaliar o perfil dos alunos concluintes, deficientes visuais e videntes do Instituto de Cegos Padre Chico entre os anos 2011 e 2020. Métodos Entre janeiro e março de 2021, foi realizada uma análise documental dos alunos concluintes entre os anos de 2011 e 2020. Foram coletados dados relacionados à situação social, educacional, socioeconômica e oftalmológica. Os dados foram tratados no programa Microsoft Excel 2013 da Microsoft e analisados no software livre Bioestat, versão 5.0. Resultados Foram coletados os [...] RESUMO Objetivo Avaliar o perfil dos alunos concluintes, deficientes visuais e videntes do Instituto de Cegos Padre Chico entre os anos 2011 e 2020. Métodos Entre janeiro e março de 2021, foi realizada uma análise documental dos alunos concluintes entre os anos de 2011 e 2020. Foram coletados dados relacionados à situação social, educacional, socioeconômica e oftalmológica. Os dados foram tratados no programa Microsoft Excel 2013 da Microsoft e analisados no software livre Bioestat, versão 5.0. Resultados Foram coletados os
- Open Access
Expanding the Phenotypic and Genotypic Spectrum of Bietti Crystalline Dystrophy
The rare form of retinal dystrophy, Bietti crystalline dystrophy, is associated with variations in CYP4V2, a member of the cytochrome P450 family. This study reports patients affected by typical and atypical Bietti crystalline dystrophy, expanding the spectrum of this disease. This is an observational case series of patients with a clinical and molecular diagnosis of Bietti crystalline dystrophy that underwent multimodal imaging. Four unrelated patients are described with two known variants, c.802-8_810del17insGC and c.518T > G (p.Leu173Trp), and one novel missense variant, c.1169G > T (p.Arg390Leu). The patient with the novel homozygous variant had the most severe phenotype resulting in macular hole formation and retinal detachment in both eyes. To the best of our knowledge, there is no association of these features with Bietti crystalline dystrophy. Patient 1 was the youngest patient and had the mildest phenotype with crystals in the retina without chorioretinal atrophy and visual complaints. Patients 2 and 3 presented with fewer crystals and chorioretinal atrophy. These three patients presented a classic phenotype. The fourth patient presented with an atypical and severe phenotype. This study reveals a new genotype and new phenotype associated with this disorder.
Open AccessExpanding the Phenotypic and Genotypic Spectrum of Bietti Crystalline Dystrophy
The rare form of retinal dystrophy, Bietti crystalline dystrophy, is associated with variations in CYP4V2, a member of the cytochrome P450 family. This study reports patients affected by typical and atypical Bietti crystalline dystrophy, expanding the spectrum of this disease. This is an observational case series of patients with a clinical and molecular diagnosis of Bietti crystalline dystrophy that underwent multimodal imaging. Four unrelated patients are described with two known variants, c.802-8_810del17insGC and c.518T > G (p.Leu173Trp), and one novel missense variant, c.1169G > T (p.Arg390Leu). The patient with the novel homozygous variant had the most severe phenotype resulting in macular hole formation and retinal detachment in both eyes. To the best of our knowledge, there is no association of these features with Bietti crystalline dystrophy. Patient 1 was the youngest patient and had the mildest phenotype with crystals in the retina without chorioretinal atrophy and visual complaints. Patients 2 and 3 presented with fewer crystals and chorioretinal atrophy. These three patients presented a classic phenotype. The fourth patient presented with an atypical and severe phenotype. This study reveals a new genotype and new phenotype associated with this disorder.