Corinna Kroner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Corinna Kroner has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Oliver Büker
RISE Research Institutes of Sweden , Borås , Sweden
5 shared publications - Daniel Schumann
Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
4 shared publications Günter Hagemann
3 shared publicationsHeiko Warnecke
3 shared publications- Heiko Warnecke
Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
3 shared publications - Jens Tränckner
Faculty of Agriculture and Environmental Sciences, University of Rostock, 18059 Rostock, Germany
3 shared publications
Latest Publications
- 11 May 2026
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 93 (9-10) , 556-568
Untersuchung des Messverhaltens von Hauswasserzählern auf Basis von Daten aus Stichprobenprüfungen
Zusammenfassung: Mit der Erfassung des Trinkwasserverbrauchs und damit verbunden mit der Verbrauchsabrechnung sind immer wieder Diskussionen hinsichtlich der Messrichtigkeit der eingesetzten Wasserzähler oder deren Betriebszeit verbunden. Vor diesem Hintergrund wird anhand von Daten aus Stichprobenprüfungen in Deutschland das Messverhalten mechanischer und statischer (Ultraschall, magnetisch-induktiv) Hauswasserzähler analysiert und verglichen. Hinsichtlich der durchflussspezifischen Messabweichungen zeigen sich signifikante Unterschiede zwischen den Zählertypen. So tritt bei mechanischen Hauswasserzählern und hier insbesondere bei Ringkolbenzählern ein bis zu einem Faktor 6 häufigeres Überschreiten der Verkehrsfehlergrenzen im Vergleich zu statischen Zählern auf. Ebenso kommen Stehenbleiber bei mechanischen Zählern bei den Prüfdurchflüssen Q 1 und Q 2 um mehr als den Faktor 10 häufiger als bei statischen Zählern vor. Für alle Zählertypen deutet sich eine leichte Abhängigkeit der Häufigkeit, mit der Verkehrsfehlergrenzen überschritten werden, vom erfassten Volumen an. Als Gesamtbild zeichnet sich ab, dass elektronische Wasserzähler ein insgesamt qualitativ besseres Messverhalten zu zeigen scheinen. Hinsichtlich der erfassten Verbräuche weisen einfache Mehrstrahlflügelradzähler eher höhere Werte aus, während Ultraschallzähler im Vergleich die kleineren Gesamtvolumina erfassen. Der Unterschied Spitze-Spitze liegt bei über 20 %. Anzumerken ist, dass die Stichprobendaten lediglich einen ersten Einblick geben können, da nur solche Zähler in die Prüfung gegeben werden, von denen erwartet wird, dass diese die Prüfung bestehen.
- 11 May 2026
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 93 (9-10) , 556-568
Untersuchung des Messverhaltens von Hauswasserzählern auf Basis von Daten aus Stichprobenprüfungen
Zusammenfassung: Mit der Erfassung des Trinkwasserverbrauchs und damit verbunden mit der Verbrauchsabrechnung sind immer wieder Diskussionen hinsichtlich der Messrichtigkeit der eingesetzten Wasserzähler oder deren Betriebszeit verbunden. Vor diesem Hintergrund wird anhand von Daten aus Stichprobenprüfungen in Deutschland das Messverhalten mechanischer und statischer (Ultraschall, magnetisch-induktiv) Hauswasserzähler analysiert und verglichen. Hinsichtlich der durchflussspezifischen Messabweichungen zeigen sich signifikante Unterschiede zwischen den Zählertypen. So tritt bei mechanischen Hauswasserzählern und hier insbesondere bei Ringkolbenzählern ein bis zu einem Faktor 6 häufigeres Überschreiten der Verkehrsfehlergrenzen im Vergleich zu statischen Zählern auf. Ebenso kommen Stehenbleiber bei mechanischen Zählern bei den Prüfdurchflüssen Q 1 und Q 2 um mehr als den Faktor 10 häufiger als bei statischen Zählern vor. Für alle Zählertypen deutet sich eine leichte Abhängigkeit der Häufigkeit, mit der Verkehrsfehlergrenzen überschritten werden, vom erfassten Volumen an. Als Gesamtbild zeichnet sich ab, dass elektronische Wasserzähler ein insgesamt qualitativ besseres Messverhalten zu zeigen scheinen. Hinsichtlich der erfassten Verbräuche weisen einfache Mehrstrahlflügelradzähler eher höhere Werte aus, während Ultraschallzähler im Vergleich die kleineren Gesamtvolumina erfassen. Der Unterschied Spitze-Spitze liegt bei über 20 %. Anzumerken ist, dass die Stichprobendaten lediglich einen ersten Einblick geben können, da nur solche Zähler in die Prüfung gegeben werden, von denen erwartet wird, dass diese die Prüfung bestehen.
- Open Access
- 27 February 2025
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 104
Development of a prototype for measuring the fuel consumption of ocean-going ships
- 27 February 2025
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 104
Open AccessDevelopment of a prototype for measuring the fuel consumption of ocean-going ships
- Open Access
- 13 January 2024
- Published by Elsevier in Measurement
- Vol. 226
Metrology for reliable fuel consumption measurements in the maritime sector
- 13 January 2024
- Published by Elsevier in Measurement
- Vol. 226
Open AccessMetrology for reliable fuel consumption measurements in the maritime sector
- Open Access
- 19 July 2023
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 93
Characterisation of a Coriolis flow meter for fuel consumption measurements in realistic drive cycle tests
- 19 July 2023
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 93
Open AccessCharacterisation of a Coriolis flow meter for fuel consumption measurements in realistic drive cycle tests
- Open Access
- 22 November 2022
- Published by IWA Publishing in Water Supply
- Vol. 22 (12) , 8405-8417
Effect of the sampling interval on the measurement accuracy of electronic water meters under real consumption conditions
The share of electronic water meters installed in households has increased sharply in recent years. However, the current regulations are in large parts still tailored to traditional mechanical water meters. Electronic meters have already been included in the common standards, but reviews and various adaptions are still missing. An important point to be reviewed is the impact of the sampling interval of the electronic water meters on the measurement accuracy of the captured water volume. In this study, the error caused by the sampling interval is investigated by using measured data sets and stochastic water consumption data. It is shown that the error caused by sampling depends on the starting point of the sampling and the observation period. The studies show that for a billing period of one year, which is common in Germany, the sampling interval should be 14 s or less to always ensure a sampling-related error of less than 0.5%. Based on the results, input for further regulations is derived.
- 22 November 2022
- Published by IWA Publishing in Water Supply
- Vol. 22 (12) , 8405-8417
Open AccessEffect of the sampling interval on the measurement accuracy of electronic water meters under real consumption conditions
The share of electronic water meters installed in households has increased sharply in recent years. However, the current regulations are in large parts still tailored to traditional mechanical water meters. Electronic meters have already been included in the common standards, but reviews and various adaptions are still missing. An important point to be reviewed is the impact of the sampling interval of the electronic water meters on the measurement accuracy of the captured water volume. In this study, the error caused by the sampling interval is investigated by using measured data sets and stochastic water consumption data. It is shown that the error caused by sampling depends on the starting point of the sampling and the observation period. The studies show that for a billing period of one year, which is common in Germany, the sampling interval should be 14 s or less to always ensure a sampling-related error of less than 0.5%. Based on the results, input for further regulations is derived.
- Open Access
- 14 March 2022
- Published by IWA Publishing in Water Supply
- Vol. 22 (4) , 4700-4715
Evaluation of the measurement performance of water meters depending on water quality
Water meters of different types and sizes are used to monitor and bill the water supply. Although the water is of drinking water quality, its chemo-physical properties often adversely affect the measuring behaviour of a meter after a while. There is thus the risk that they no longer meet legal requirements and may no longer be used. In this paper a test regime with a focus on pH, total hardness and particle load is presented which allows water meters to be tested closer to their operating conditions prior to placing them on the market. The regime goes beyond the conventional continuous durability test as described in OIML R49:2013(E) and ISO 4064:2014. The feasibility and reliability of the test regime has been demonstrated through implementation at different facilities. In the study, the measurement performance of water meters of various types and from different manufacturers was also investigated. A heterogeneous spread of measurement errors was found for both, water meters in mint conditions and those which were exposed to a defined water quality. Furthermore, compared to the conventional continuous durability test, the test regime developed in the study generally leads to stronger changes in the measurement error of the water meters.
- 14 March 2022
- Published by IWA Publishing in Water Supply
- Vol. 22 (4) , 4700-4715
Open AccessEvaluation of the measurement performance of water meters depending on water quality
Water meters of different types and sizes are used to monitor and bill the water supply. Although the water is of drinking water quality, its chemo-physical properties often adversely affect the measuring behaviour of a meter after a while. There is thus the risk that they no longer meet legal requirements and may no longer be used. In this paper a test regime with a focus on pH, total hardness and particle load is presented which allows water meters to be tested closer to their operating conditions prior to placing them on the market. The regime goes beyond the conventional continuous durability test as described in OIML R49:2013(E) and ISO 4064:2014. The feasibility and reliability of the test regime has been demonstrated through implementation at different facilities. In the study, the measurement performance of water meters of various types and from different manufacturers was also investigated. A heterogeneous spread of measurement errors was found for both, water meters in mint conditions and those which were exposed to a defined water quality. Furthermore, compared to the conventional continuous durability test, the test regime developed in the study generally leads to stronger changes in the measurement error of the water meters.
- Open Access
- 14 March 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (2) , 025007
New metrological capabilities for measurements of dynamic liquid flows
The capability to calibrate flow and volume devices dynamically has gained increasing interest over the years. Within the scope of the EMPIR project 17IND13 ‘Metrology for real-world domestic water metering’, several test rigs were developed with which dynamic flow profiles can be generated and measured that reflect characteristics of real-world drinking water consumption. The dynamic component of the test rigs is realized based on different technologies such as valves, cavitation nozzles or piston provers. For validation purposes, an intercomparison of the test rigs was carried out in the scope of an EURAMET pilot study no. 1506. Between September 2020 and February 2021, a transfer standard specially developed for the intercomparison was calibrated at eight laboratories. The measurement error was determined for three dynamic flow profiles representative of drinking water consumption in Europe. In addition to determining the measurement errors and the degree of equivalence, five additional key parameters were derived to characterize the test rig properties: (1) repeatability of the profile measurements, (2) mean value of the residuals, (3) deviation between measured total mass and total mass resulting from the given profile and (4) duration of the flow change for an increasing change (5) and duration of the flow change for a decreasing change. These key parameters comprehensively describe the quality with which the dynamic flow profiles were generated and measured on the test rigs and can be used for evaluations in future intercomparisons of this kind. A main outcome of the intercomparison is that there is no technology to be preferred in terms of technical implementation. All test rigs agree well with each other, taking into account their expanded measurement uncertainties.
- 14 March 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (2) , 025007
Open AccessNew metrological capabilities for measurements of dynamic liquid flows
The capability to calibrate flow and volume devices dynamically has gained increasing interest over the years. Within the scope of the EMPIR project 17IND13 ‘Metrology for real-world domestic water metering’, several test rigs were developed with which dynamic flow profiles can be generated and measured that reflect characteristics of real-world drinking water consumption. The dynamic component of the test rigs is realized based on different technologies such as valves, cavitation nozzles or piston provers. For validation purposes, an intercomparison of the test rigs was carried out in the scope of an EURAMET pilot study no. 1506. Between September 2020 and February 2021, a transfer standard specially developed for the intercomparison was calibrated at eight laboratories. The measurement error was determined for three dynamic flow profiles representative of drinking water consumption in Europe. In addition to determining the measurement errors and the degree of equivalence, five additional key parameters were derived to characterize the test rig properties: (1) repeatability of the profile measurements, (2) mean value of the residuals, (3) deviation between measured total mass and total mass resulting from the given profile and (4) duration of the flow change for an increasing change (5) and duration of the flow change for a decreasing change. These key parameters comprehensively describe the quality with which the dynamic flow profiles were generated and measured on the test rigs and can be used for evaluations in future intercomparisons of this kind. A main outcome of the intercomparison is that there is no technology to be preferred in terms of technical implementation. All test rigs agree well with each other, taking into account their expanded measurement uncertainties.
- Open Access
- 1 December 2021
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 82
Generation, validation and application of dynamic load profiles in flow measurement using cavitating Herschel–Venturi nozzles
- 1 December 2021
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 82
Open AccessGeneration, validation and application of dynamic load profiles in flow measurement using cavitating Herschel–Venturi nozzles
- Open Access
Investigations on the Influence of Total Water Hardness and pH Value on the Measurement Accuracy of Domestic Cold Water Meters
In the framework of the ongoing EMPIR Joint Research Project (JRP) 17IND13 Metrology for real-world domestic water metering (Metrowamet), a main task is to investigate the influence of realistic operation conditions, that is, typical water qualities (suspended particles, degree of hardness, and pH value), on the measurement accuracy. For this purpose, two representative types of cold water meters were investigated in more detail. Initially, the cold water meters were calibrated and then subjected to an accelerated wear test with water of different pH values and degrees of hardness. The accelerated wear tests were designed to reproduce the realistic use and service life of a cold water meter. Subsequently, the cold water meters were re-calibrated to assess the influence of the different water qualities on the measurement accuracy. One of the results was that the measurement accuracy of the water meters investigated was not strongly affected by the water quality. The practical realisation and the measurement results are reported in this paper.
Open AccessInvestigations on the Influence of Total Water Hardness and pH Value on the Measurement Accuracy of Domestic Cold Water Meters
In the framework of the ongoing EMPIR Joint Research Project (JRP) 17IND13 Metrology for real-world domestic water metering (Metrowamet), a main task is to investigate the influence of realistic operation conditions, that is, typical water qualities (suspended particles, degree of hardness, and pH value), on the measurement accuracy. For this purpose, two representative types of cold water meters were investigated in more detail. Initially, the cold water meters were calibrated and then subjected to an accelerated wear test with water of different pH values and degrees of hardness. The accelerated wear tests were designed to reproduce the realistic use and service life of a cold water meter. Subsequently, the cold water meters were re-calibrated to assess the influence of the different water qualities on the measurement accuracy. One of the results was that the measurement accuracy of the water meters investigated was not strongly affected by the water quality. The practical realisation and the measurement results are reported in this paper.
- Open Access
- 1 June 2021
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 79
Measurements of water consumption for the development of new test regimes for domestic water meters
- 1 June 2021
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 79
Open AccessMeasurements of water consumption for the development of new test regimes for domestic water meters