PCPeng Chen

Peng Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peng Chen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Ji Fan

    National Gravitation Laboratory, the MOE Key Laboratory of Fundamental Physical Quantities Measurement, and the School of Physics, Huazhong University of Science and Technology, Wuhan, China

    3 shared publications
  • Jinquan Liu

    Huazhong University of Science and Technology

    3 shared publications
  • Liangcheng Tu

    National Gravitation Laboratory, MOE Key Laboratory of Fundamental Physical Quantities Measurement, School of Physics, Huazhong University of Science and Technology, Wuhan, China

    3 shared publications
  • Chenyuan Hu

    National Gravitation Laboratory, the MOE Key Laboratory of Fundamental Physical Quantities Measurement, and the School of Physics, Huazhong University of Science and Technology, Wuhan, China

    2 shared publications
  • Li Yu

    National Gravitation Laboratory, the MOE Key Laboratory of Fundamental Physical Quantities Measurement, and the School of Physics, Huazhong University of Science and Technology, Wuhan, China

    2 shared publications
  • Mingbiao Yu

    Key Laboratory of Advanced Manufacturing Technology, Ministry of Education, School of Mechanical Engineering, Guizhou University, Guiyang, China

    2 shared publications

Latest Publications

  • Implementation of Effective Scale Factor Matching and Axial Centripetal Error Compensation for a Rotating Accelerometer Gravity Gradiometer

    by Jianyuan Pi, Xiaobing Yu, Peng Chen, Mingbiao Yu, Li Yu, Ji Fan, Jinquan Liu, Chenyuan Hu, Liangcheng Tu

    Rotating Accelerometer Gravity Gradientmeter (RAGG) is the only gravity gradient measuring device in the world to achieve commercial applications. When the parameter consistency among multiple accelerometers of the RAGG is not sufficient, its combined output cannot effectively suppress common-mode noise in the environment. A method for suppressing RAGG’s linear and angular motion noise is presented in this paper by projecting the parameters, including scale factor, misalignment angle, second-order terms and cross-coupling terms, onto the cartesian coordinate system of the turntable plane. Proposing the algorithm implementation scheme of three effective scale factor solver loops, and for further canceling the motion residual error, high precision gyroscope compensation loops is introduced. The added error compensation loop obtains the angular acceleration by differencing the angular velocity measured by the gyroscope, which in turn adjusts the loop parameters. Experimental results show that with the proposed method, the noise suppression of linear motion common-mode acceleration reaches 6.5 orders of magnitude, that is, the noise level 2.7 × 10 -8 g/ √ Hz of the accelerometer at the rotation frequency, and the angular motion common-mode acceleration noise is suppressed by 6 orders of magnitude, and the noise level 6.8×10 -8 g/ √ Hz of the accelerometer at the swing frequency is also obtained.


  • Quantitative Analysis of the Effects of Environmental Magnetic Field in Gravity Gradient Sensing

    by Chenyuan Hu, Tao Jiang, Peng Chen, Jingda Xiong, Li Yu, Mingbiao Yu, Wenjie Wu, Jinquan Liu, Ji Fan, Liangcheng Tu

    Magnetic field affects the sensing performance of rotating accelerometer gravity gradient instrument (RAGGI) used for airborne mineral exploration and gravity aided navigation. This paper studies the error introduction mechanism of the RAGGI measurement platform caused by the environmental magnetic field. It is clarified that the inseparable function relationship between gravity gradient and magnetic gradient based on magnetic-feedback-accelerometer RAGGI measurement principle. The RAGGI gravity gradient sensing output with environmental magnetic field quantitative analysis model is proposed and established. The experimental verification scheme of moving a ferromagnetic gravitational source for generating the gravity gradient anomaly and magnetic gradient anomaly simultaneously is set up. The experimental results witness that by lowering the magnetic sensitivity coefficient of the four accelerometers from >10 V/T to 56% to<1%, and verifies the effectiveness of the proposed error correction output model.


  • Open Access

    Cross-Coupling Coefficient Estimation of a Nano-gAccelerometer by Continuous Rotation Modulation on a Tilted Rate Table

    by Mengqi Zhang, Shitao Yan, Zhongguang Deng, Peng Chen, Zhi Li, Ji Fan, Huafeng Liu, Jinquan Liu, Liangcheng Tu

    Nano- g accelerometers are widely used in space exploration and measurement of the earth's gravitational field. It is essential to precisely evaluate error effects at high orders such as cross-coupling for applications in a dynamic environment. Nevertheless, it remains challenging to meet the precision requirements using conventional calibration measures. In this article, we propose a method to separate the cross-coupling coefficients of a linear single-axis accelerometer by mounting it on a steadily rotating rate table that is tilted at a fixed deviation angle with respect to the horizontal plane. The gravity component is periodically modulated along the input axis per revolution. Simultaneously, a series of centripetal acceleration is applied along the cross axis in sequence while adjusting the rotation frequency of the rate table by steps. Thus, the cross-coupling coefficient can be separated by its dependence both on the modulated gravity acceleration and the centripetal acceleration. In comparison to the static multipoint angular rotation test on a tilted dividing head, the proposed dynamic modulation method demonstrates improved robustness against corruption from bias drift, with an improved uncertainty. This method to separate the cross-coupling coefficient is suitable for testing high-resolution accelerometers, without requiring high bias stability or sensitive response sustaining at ultralow frequency.