Baha Sakar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Baha Sakar has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Sibylle Sievers
Physikalisch-Technische Bundesanstalt
3 shared publications - Alexander Fernández Scarioni
Physikalisch-Technische Bundesanstalt, 38116 Braunschweig, Germany
2 shared publications - Felipe Garcia-Sanchez
Universidad de Salamanca
2 shared publications Hans W. Schumacher
Physikalisch-Technische Bundesanstalt, 38116 Braunschweig, Germany
2 shared publicationsAli Ata
Department of Material Science and Engineering, ‡Institute of Nanotechnology, ∥Department of Bioengineering, §Department of Physics, and ⊥Department of Chemical Engineering, Gebze Technical University, Gebze, Kocaeli 41400 Turkey
1 shared publication- Antonia Neels
Center for X-ray Analytics, Swiss Federal Laboratories for Materials Science and Technology (Empa), 8600 Dübendorf, Switzerland
1 shared publication
Latest Publications
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
On the influence of reference sample properties on magnetic force microscopy calibrations
Magnetic force microscopy (MFM) allows the characterization of magnetic stray field distributions with high sensitivity and spatial resolution. Based on a suitable calibration procedure, MFM can also yield quantitative magnetic field values. This process typically involves measuring a reference sample to determine the distribution of the tip’s stray field or stray field gradient at the sample surface. This distribution is called the tip transfer function (TTF) and is derived through regularized deconvolution in Fourier space. The properties of the reference sample and the noise characteristics of the detection system significantly influence the derived TTF, thereby limiting its validity range. In a recent study, the tip stray field distribution, and hence the TTF, of an MFM tip was independently measured in real space using a nitrogen vacancy center as a quantum sensor, revealing considerable discrepancies with the reference-sample-based TTF. Here, we analyze the influence of the feature distribution of the reference sample and the MFM measurement parameters on the resulting TTF. We explain the observed differences between quantum-calibrated stray field distributions and the classical approach by attributing them to a loss of information due to missing or suppressed spectral components. Furthermore, we emphasize the importance of the spectral coverage of the TTF. Our findings indicate that for high-quality reconstruction of the stray field of a sample under test (SUT), it is more critical to ensure a strong overlap of frequency components between the reference sample and the SUT than to achieve an accurate real-space reconstruction of the tip stray field distribution.
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
On the influence of reference sample properties on magnetic force microscopy calibrations
Magnetic force microscopy (MFM) allows the characterization of magnetic stray field distributions with high sensitivity and spatial resolution. Based on a suitable calibration procedure, MFM can also yield quantitative magnetic field values. This process typically involves measuring a reference sample to determine the distribution of the tip’s stray field or stray field gradient at the sample surface. This distribution is called the tip transfer function (TTF) and is derived through regularized deconvolution in Fourier space. The properties of the reference sample and the noise characteristics of the detection system significantly influence the derived TTF, thereby limiting its validity range. In a recent study, the tip stray field distribution, and hence the TTF, of an MFM tip was independently measured in real space using a nitrogen vacancy center as a quantum sensor, revealing considerable discrepancies with the reference-sample-based TTF. Here, we analyze the influence of the feature distribution of the reference sample and the MFM measurement parameters on the resulting TTF. We explain the observed differences between quantum-calibrated stray field distributions and the classical approach by attributing them to a loss of information due to missing or suppressed spectral components. Furthermore, we emphasize the importance of the spectral coverage of the TTF. Our findings indicate that for high-quality reconstruction of the stray field of a sample under test (SUT), it is more critical to ensure a strong overlap of frequency components between the reference sample and the SUT than to achieve an accurate real-space reconstruction of the tip stray field distribution.
- 12 September 2023
- Published by American Physical Society (APS) in Physical Review B
- Vol. 108 (10) , 104409
Radially dependent stray field signature of chiral magnetic skyrmions
Magnetic skyrmions are topological spin structures that arise in chiral magnetic systems which exhibit broken inversion symmetry and high spin-orbit coupling resulting in a sizable Dzyaloshinskii-Moriya interaction. Understanding the local spin texture of skyrmions is a vital metrological step in the development of skyrmionic technologies required for novel logic or storage devices in addition to providing fundamental insight into the nanoscale chiral interactions inherent to these systems. Here, we propose that there exists a radially dependent stray field signature that emanates from magnetic skyrmions. We employ quantitative magnetic force microscopy to experimentally explore this stray field signature. To corroborate the experimental observations a semianalytical model is developed which is validated against micromagnetic simulations. This unique approach provides a route to understand the unique radially dependent field signature from skyrmions, which allows an understanding of the underlying local magnetization profile to be obtained. From a practical standpoint, our results provide a rapid approach to validate outputs from numerical or micromagnetic simulations. This approach could be employed to optimize the complex matrix of magnetic parameters required for fabricating and modeling skyrmionic systems, in turn accelerating the technology readiness level of skyrmionic based devices.
- 12 September 2023
- Published by American Physical Society (APS) in Physical Review B
- Vol. 108 (10) , 104409
Radially dependent stray field signature of chiral magnetic skyrmions
Magnetic skyrmions are topological spin structures that arise in chiral magnetic systems which exhibit broken inversion symmetry and high spin-orbit coupling resulting in a sizable Dzyaloshinskii-Moriya interaction. Understanding the local spin texture of skyrmions is a vital metrological step in the development of skyrmionic technologies required for novel logic or storage devices in addition to providing fundamental insight into the nanoscale chiral interactions inherent to these systems. Here, we propose that there exists a radially dependent stray field signature that emanates from magnetic skyrmions. We employ quantitative magnetic force microscopy to experimentally explore this stray field signature. To corroborate the experimental observations a semianalytical model is developed which is validated against micromagnetic simulations. This unique approach provides a route to understand the unique radially dependent field signature from skyrmions, which allows an understanding of the underlying local magnetization profile to be obtained. From a practical standpoint, our results provide a rapid approach to validate outputs from numerical or micromagnetic simulations. This approach could be employed to optimize the complex matrix of magnetic parameters required for fabricating and modeling skyrmionic systems, in turn accelerating the technology readiness level of skyrmionic based devices.
- 21 December 2021
- Published by American Physical Society (APS) in Physical Review B
- Vol. 104 (21) , 214427
Quantum calibrated magnetic force microscopy
We report the quantum calibration of a magnetic force microscope (MFM) by measuring the two-dimensional magnetic stray-field distribution of the MFM tip using a single nitrogen vacancy (NV) center in diamond. From the measured stray-field distribution and the mechanical properties of the cantilever a calibration function is derived allowing to convert MFM images to quantum calibrated stray-field maps. This approach overcomes limitations of prior MFM calibration schemes and allows quantum calibrated nanoscale stray-field measurements in a field range inaccessible to scanning NV magnetometry. Quantum calibrated measurements of a stray-field reference sample allow its use as a transfer standard, opening the road towards fast and easily accessible quantum traceable calibrations of virtually any MFM.
- 21 December 2021
- Published by American Physical Society (APS) in Physical Review B
- Vol. 104 (21) , 214427
Quantum calibrated magnetic force microscopy
We report the quantum calibration of a magnetic force microscope (MFM) by measuring the two-dimensional magnetic stray-field distribution of the MFM tip using a single nitrogen vacancy (NV) center in diamond. From the measured stray-field distribution and the mechanical properties of the cantilever a calibration function is derived allowing to convert MFM images to quantum calibrated stray-field maps. This approach overcomes limitations of prior MFM calibration schemes and allows quantum calibrated nanoscale stray-field measurements in a field range inaccessible to scanning NV magnetometry. Quantum calibrated measurements of a stray-field reference sample allow its use as a transfer standard, opening the road towards fast and easily accessible quantum traceable calibrations of virtually any MFM.
- 24 September 2021
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 60 (10) , 105505
Structural and morphological effect of Ti underlayer on Pt/Co/Pt magnetic ultra-thin film
Pt( x Å)/Co(5 Å)/Pt(10 Å) trilayer films with x = 5, 8, and 10 Å were deposited on naturally oxidized Si ( 111 ) substrate to investigate the Ti underlayer effect on perpendicular magnetic anisotropy. A small amount of Ti underlayer promoted the magnetic anisotropy to perpendicular direction for x = 8 and 10 Å and also affected the growth mode of the trilayer film. The Pt particles preferably grew in the neighborhood of the Ti cluster, giving rise to a relatively smooth layer with a fcc fiber texture ( 111 ) structure. By contrast, the absence of a Ti underlayer led to a clustered, relatively rough, and randomly oriented nano-crystalline growth. Differences in the growth mode appeared as intensity loss in X-ray photoelectron spectroscopy spectra due to shadowing effects. Our results indicate that traceable amount of underlayer can change the magnetic anisotropy of the film by influencing the film growth.
- 24 September 2021
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 60 (10) , 105505
Structural and morphological effect of Ti underlayer on Pt/Co/Pt magnetic ultra-thin film
Pt( x Å)/Co(5 Å)/Pt(10 Å) trilayer films with x = 5, 8, and 10 Å were deposited on naturally oxidized Si ( 111 ) substrate to investigate the Ti underlayer effect on perpendicular magnetic anisotropy. A small amount of Ti underlayer promoted the magnetic anisotropy to perpendicular direction for x = 8 and 10 Å and also affected the growth mode of the trilayer film. The Pt particles preferably grew in the neighborhood of the Ti cluster, giving rise to a relatively smooth layer with a fcc fiber texture ( 111 ) structure. By contrast, the absence of a Ti underlayer led to a clustered, relatively rough, and randomly oriented nano-crystalline growth. Differences in the growth mode appeared as intensity loss in X-ray photoelectron spectroscopy spectra due to shadowing effects. Our results indicate that traceable amount of underlayer can change the magnetic anisotropy of the film by influencing the film growth.
- Open Access
- 1 June 2021
- Published by MDPI AG in Magnetochemistry
- Vol. 7 (6) , 78
A Ti/Pt/Co Multilayer Stack for Transfer Function Based Magnetic Force Microscopy Calibrations
Magnetic force microscopy (MFM) is a widespread technique for imaging magnetic structures with a resolution of some 10 nanometers. MFM can be calibrated to obtain quantitative (qMFM) spatially resolved magnetization data in units of A/m by determining the calibrated point spread function of the instrument, its instrument calibration function (ICF), from a measurement of a well-known reference sample. Beyond quantifying the MFM data, a deconvolution of the MFM image data with the ICF also corrects the smearing caused by the finite width of the MFM tip stray field distribution. However, the quality of the calibration depends critically on the calculability of the magnetization distribution of the reference sample. Here, we discuss a Ti/Pt/Co multilayer stack that shows a stripe domain pattern as a suitable reference material. A precise control of the fabrication process, combined with a characterization of the sample micromagnetic parameters, allows reliable calculation of the sample’s magnetic stray field, proven by a very good agreement between micromagnetic simulations and qMFM measurements. A calibrated qMFM measurement using the Ti/Pt/Co stack as a reference sample is shown and validated, and the application area for quantitative MFM measurements calibrated with the Ti/Pt/Co stack is discussed.
- 1 June 2021
- Published by MDPI AG in Magnetochemistry
- Vol. 7 (6) , 78
Open AccessA Ti/Pt/Co Multilayer Stack for Transfer Function Based Magnetic Force Microscopy Calibrations
Magnetic force microscopy (MFM) is a widespread technique for imaging magnetic structures with a resolution of some 10 nanometers. MFM can be calibrated to obtain quantitative (qMFM) spatially resolved magnetization data in units of A/m by determining the calibrated point spread function of the instrument, its instrument calibration function (ICF), from a measurement of a well-known reference sample. Beyond quantifying the MFM data, a deconvolution of the MFM image data with the ICF also corrects the smearing caused by the finite width of the MFM tip stray field distribution. However, the quality of the calibration depends critically on the calculability of the magnetization distribution of the reference sample. Here, we discuss a Ti/Pt/Co multilayer stack that shows a stripe domain pattern as a suitable reference material. A precise control of the fabrication process, combined with a characterization of the sample micromagnetic parameters, allows reliable calculation of the sample’s magnetic stray field, proven by a very good agreement between micromagnetic simulations and qMFM measurements. A calibrated qMFM measurement using the Ti/Pt/Co stack as a reference sample is shown and validated, and the application area for quantitative MFM measurements calibrated with the Ti/Pt/Co stack is discussed.
- 10 July 2017
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 121 (28) , 15120-15126
Investigation of the Effect of Using Al2O3–Nafion Barrier on Room-Temperature Na–S Batteries
- 10 July 2017
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 121 (28) , 15120-15126
Investigation of the Effect of Using Al2O3–Nafion Barrier on Room-Temperature Na–S Batteries