MSMarek Siranec

Marek Siranec

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marek Siranec has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • Alena Otcenasova

    Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, Zilina, Slovak Republic

    2 shared publications
  • Marek Hoger

    Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, University of Zilina, Univerzitná 8215/1, 01026 Žilina, Slovakia

    2 shared publications
  • Michal Regula

    Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, Zilina, Slovak Republic

    1 shared publication

Latest Publications

  • Possibilities of the stray current measurement and corrosive risk evaluation

    by Michal Regula, Marek Siranec, Alena Otcenasova, Marek Hoger


  • Open Access

    Advanced Power Line Diagnostics Using Point Cloud Data—Possible Applications and Limits

    by Marek Siranec, Marek Höger, Alena Otcenasova

    The advance in remote sensing techniques, especially the development of LiDAR scanning systems, allowed the development of new methods for power line corridor surveys using a digital model of the powerline and its surroundings. The advanced diagnostic techniques based on the acquired conductor geometry recalculation to extreme operating and climatic conditions were proposed using this digital model. Although the recalculation process is relatively easy and straightforward, the uncertainties of input parameters used for the recalculation can significantly compromise such recalculation accuracy. This paper presents a systematic analysis of the accuracy of the recalculation affected by the inaccuracies of the conductor state equation input variables. The sensitivity of the recalculation to the inaccuracy of five basic input parameters was tested (initial temperature and mechanical tension, elasticity modulus, specific gravity load and tower span) by comparing the conductor sag values when input parameters were affected by a specific inaccuracy with an ideal sag-tension table. The presented tests clearly showed that the sag recalculation inaccuracy must be taken into account during the safety assessment process, as the sag deviation can, in some cases, reach values comparable to the minimal clearance distances specified in the technical standards.