Marek Siranec
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marek Siranec has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Alena Otcenasova
Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, Zilina, Slovak Republic
2 shared publications - Marek Hoger
Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, University of Zilina, Univerzitná 8215/1, 01026 Žilina, Slovakia
2 shared publications - Michal Regula
Department of Power Systems and Electric Drives, Faculty of Electrical Engineering and Information Technology, Zilina, Slovak Republic
1 shared publication
Latest Publications
- 7 February 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (4) , 2497-2513
Possibilities of the stray current measurement and corrosive risk evaluation
- 7 February 2022
- Published by Springer Nature in Electrical Engineering
- Vol. 104 (4) , 2497-2513
Possibilities of the stray current measurement and corrosive risk evaluation
- Open Access
- 11 May 2021
- Published by MDPI AG in Remote Sensing
- Vol. 13 (10) , 1880
Advanced Power Line Diagnostics Using Point Cloud Data—Possible Applications and Limits
The advance in remote sensing techniques, especially the development of LiDAR scanning systems, allowed the development of new methods for power line corridor surveys using a digital model of the powerline and its surroundings. The advanced diagnostic techniques based on the acquired conductor geometry recalculation to extreme operating and climatic conditions were proposed using this digital model. Although the recalculation process is relatively easy and straightforward, the uncertainties of input parameters used for the recalculation can significantly compromise such recalculation accuracy. This paper presents a systematic analysis of the accuracy of the recalculation affected by the inaccuracies of the conductor state equation input variables. The sensitivity of the recalculation to the inaccuracy of five basic input parameters was tested (initial temperature and mechanical tension, elasticity modulus, specific gravity load and tower span) by comparing the conductor sag values when input parameters were affected by a specific inaccuracy with an ideal sag-tension table. The presented tests clearly showed that the sag recalculation inaccuracy must be taken into account during the safety assessment process, as the sag deviation can, in some cases, reach values comparable to the minimal clearance distances specified in the technical standards.
- 11 May 2021
- Published by MDPI AG in Remote Sensing
- Vol. 13 (10) , 1880
Open AccessAdvanced Power Line Diagnostics Using Point Cloud Data—Possible Applications and Limits
The advance in remote sensing techniques, especially the development of LiDAR scanning systems, allowed the development of new methods for power line corridor surveys using a digital model of the powerline and its surroundings. The advanced diagnostic techniques based on the acquired conductor geometry recalculation to extreme operating and climatic conditions were proposed using this digital model. Although the recalculation process is relatively easy and straightforward, the uncertainties of input parameters used for the recalculation can significantly compromise such recalculation accuracy. This paper presents a systematic analysis of the accuracy of the recalculation affected by the inaccuracies of the conductor state equation input variables. The sensitivity of the recalculation to the inaccuracy of five basic input parameters was tested (initial temperature and mechanical tension, elasticity modulus, specific gravity load and tower span) by comparing the conductor sag values when input parameters were affected by a specific inaccuracy with an ideal sag-tension table. The presented tests clearly showed that the sag recalculation inaccuracy must be taken into account during the safety assessment process, as the sag deviation can, in some cases, reach values comparable to the minimal clearance distances specified in the technical standards.