Lisa Centofante
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lisa Centofante has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
A. Andrighetto
4 shared publications- Daniele Scarpa
INFN Laboratori Nazionali di Legnaro, I-35020, Legnaro (Pd), Italy
4 shared publications - Giordano Lilli
INFN, Laboratori Nazionali di Legnaro
4 shared publications M. Manzolaro
4 shared publicationsA. Monetti
3 shared publications- Michele Ballan
INFN – Legnaro National Laboratories, Legnaro (Padua)
3 shared publications
Latest Publications
- Open Access
- 26 March 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 563
Performance evaluation of the SPES FEBIAD ion source
- 26 March 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 563
Open AccessPerformance evaluation of the SPES FEBIAD ion source
- Open Access
- 8 September 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (1) , 378-390
Remote handling systems for the Selective Production of Exotic Species (SPES) facility
- 8 September 2022
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 55 (1) , 378-390
Open AccessRemote handling systems for the Selective Production of Exotic Species (SPES) facility
- 1 August 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (8) , 083001
New solid state laser system for SPES: Selective Production of Exotic Species project at Laboratori Nazionali di Legnaro
The Selective Production of Exotic Species project is under construction at Laboratori Nazionali di Legnaro-INFN. The aim of the collaboration is to produce highly pure Radioactive Ion Beams (RIBs) from fission fragments of a uranium carbide (UCx) target activated by a cyclotron proton beam. In order to select a specific atomic species, the main tool to be applied is the resonant laser ionization technique. We have just completed the installation of a dedicated all solid state laser system whose elements are tunable to transitions of all the elements/isotopes of interest for the project. The new laser system is based on three Titanium:sapphire laser sources, independently pumped by three Nd:YLF pump lasers, and it can be coupled to two high harmonic generation (second harmonic generation, third harmonic generation, and fourth harmonic generation) setups. The power, wavelength, and position of the laser beams are continuously monitored and stabilized by using automated active systems to improve the beam production stability of RIBs. This paper presents the main features of the laser system and examples of application of a laser ion source, including a first demonstration of photoionization of stable silver, one of the most requested elements for RIB application.
- 1 August 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (8) , 083001
New solid state laser system for SPES: Selective Production of Exotic Species project at Laboratori Nazionali di Legnaro
The Selective Production of Exotic Species project is under construction at Laboratori Nazionali di Legnaro-INFN. The aim of the collaboration is to produce highly pure Radioactive Ion Beams (RIBs) from fission fragments of a uranium carbide (UCx) target activated by a cyclotron proton beam. In order to select a specific atomic species, the main tool to be applied is the resonant laser ionization technique. We have just completed the installation of a dedicated all solid state laser system whose elements are tunable to transitions of all the elements/isotopes of interest for the project. The new laser system is based on three Titanium:sapphire laser sources, independently pumped by three Nd:YLF pump lasers, and it can be coupled to two high harmonic generation (second harmonic generation, third harmonic generation, and fourth harmonic generation) setups. The power, wavelength, and position of the laser beams are continuously monitored and stabilized by using automated active systems to improve the beam production stability of RIBs. This paper presents the main features of the laser system and examples of application of a laser ion source, including a first demonstration of photoionization of stable silver, one of the most requested elements for RIB application.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053304
Study of the radioactive contamination of the ion source complex in the Selective Production of Exotic Species (SPES) facility
The Isotope Separation On-Line (ISOL) technique is today established as one of the primary methods to produce high-intensity and high-quality radioactive beams. This technique produces, for a given amount of the desired isotope, many orders of magnitude of other radioactive species. Due to the activation generated by interactions of the primary beam, intense neutron fields, and deposition of the produced radioactive ions inside beam line elements, an ISOL facility in operation becomes an intense radioactive source. Therefore, the biological hazard imposes severe radiological safety challenges to the design, operation, maintenance, and final decommissioning of such facilities. A challenging component is the ion source complex, where the ion extraction electrode provides the extraction of radioactive ions from the ion source and the first acceleration to the extracted beam. The radioactive contamination of this sub-component is studied, by means of the FLUKA code, in the case of the Selective Production of Exotic Species facility, which is in the advanced construction phase at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, Padua, Italy. The developed model includes isotope production by the interactions of a 40 MeV energy proton beam on a 238UCx target, selection of radioactive isotopes that are able to stick on the electrode tip, time evolution of the deposited isotopes during the operation and cooling periods before maintenance interventions, and evaluation of the ambient dose equivalent rate generated by the contamination of the electrode tip. Based on these results, the possibility of manual interventions for maintenance and emergency vs the use of remote handling systems is discussed.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053304
Study of the radioactive contamination of the ion source complex in the Selective Production of Exotic Species (SPES) facility
The Isotope Separation On-Line (ISOL) technique is today established as one of the primary methods to produce high-intensity and high-quality radioactive beams. This technique produces, for a given amount of the desired isotope, many orders of magnitude of other radioactive species. Due to the activation generated by interactions of the primary beam, intense neutron fields, and deposition of the produced radioactive ions inside beam line elements, an ISOL facility in operation becomes an intense radioactive source. Therefore, the biological hazard imposes severe radiological safety challenges to the design, operation, maintenance, and final decommissioning of such facilities. A challenging component is the ion source complex, where the ion extraction electrode provides the extraction of radioactive ions from the ion source and the first acceleration to the extracted beam. The radioactive contamination of this sub-component is studied, by means of the FLUKA code, in the case of the Selective Production of Exotic Species facility, which is in the advanced construction phase at Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, Padua, Italy. The developed model includes isotope production by the interactions of a 40 MeV energy proton beam on a 238UCx target, selection of radioactive isotopes that are able to stick on the electrode tip, time evolution of the deposited isotopes during the operation and cooling periods before maintenance interventions, and evaluation of the ambient dose equivalent rate generated by the contamination of the electrode tip. Based on these results, the possibility of manual interventions for maintenance and emergency vs the use of remote handling systems is discussed.
- Open Access
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1038 (1) , 012037
High temperature biaxial compressive strength of a commercial isotropic ultrafine grain graphite
Graphite is widely used in industrial applications, thanks to its excellent high temperature resistance. Therefore, its mechanical strength under combined stress at high temperature is an important issue for structural design. This work reports biaxial compressive data of an isotropic ultrafine grain graphite, the POCO EDM-3. Uniaxial tests have been first performed at room temperature with plane specimens, in order to obtain the stress strain curve for this material. Compressive tests have been then carried out with different notched geometries, both at room temperature and at 1000°C, in order to evaluate the biaxial compressive strength. Since plastic deformation was observed in uniaxial compressive tests with plane samples, elastic-plastic simulations have been performed with the FE code Ansys®, in order to assess the stress state at failure. The applicability of the Von Mises yield criterion has been evaluated, by comparing the equivalent Von Mises stresses at failure in different notched geometries. The tests demonstrated that, at room temperature, this type of graphite plastically deform in compression and that the Von Mises criterion can be used in order to evaluate the stress state. Moreover, the comparison between the failure loads at room temperature and at 1000°C showed that the resistance increases as the temperature increases.
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1038 (1) , 012037
Open AccessHigh temperature biaxial compressive strength of a commercial isotropic ultrafine grain graphite
Graphite is widely used in industrial applications, thanks to its excellent high temperature resistance. Therefore, its mechanical strength under combined stress at high temperature is an important issue for structural design. This work reports biaxial compressive data of an isotropic ultrafine grain graphite, the POCO EDM-3. Uniaxial tests have been first performed at room temperature with plane specimens, in order to obtain the stress strain curve for this material. Compressive tests have been then carried out with different notched geometries, both at room temperature and at 1000°C, in order to evaluate the biaxial compressive strength. Since plastic deformation was observed in uniaxial compressive tests with plane samples, elastic-plastic simulations have been performed with the FE code Ansys®, in order to assess the stress state at failure. The applicability of the Von Mises yield criterion has been evaluated, by comparing the equivalent Von Mises stresses at failure in different notched geometries. The tests demonstrated that, at room temperature, this type of graphite plastically deform in compression and that the Von Mises criterion can be used in order to evaluate the stress state. Moreover, the comparison between the failure loads at room temperature and at 1000°C showed that the resistance increases as the temperature increases.