EBErsoy Beser

Ersoy Beser

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ersoy Beser has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A cascaded asymmetric multilevel inverter for aircraft ground power unit: design and implementation

    by Korhan Karaarslan, Ersoy Beser, Mehlika Sengul Karaarslan, Esra Kandemir Beser

    Purpose: This study aims to propose a high-performance single-phase cascaded asymmetric multilevel inverter topology tailored for aircraft ground power units. It aims to replace conventional two-level architectures, which suffer from high harmonic content at 400 Hz and require bulky filters, with a compact solution meeting strict aviation power quality standards. Design/methodology/approach: The proposed topology integrates binary-scaled DC modules with a conventional H-bridge to synthesize a high number of voltage levels with minimized active switches. To avoid complex high-frequency PWM, a deterministic low-frequency switching strategy is implemented. The system’s steady-state and dynamic performance under load variations were verified via simulations and validated on a 31-level laboratory prototype. Findings: Experimental results demonstrate stable voltage regulation under both steady-state and dynamic load conditions, maintaining the output RMS voltage within a 108–118V tolerance band at 400 Hz. The system delivers a high-quality 31-level output voltage waveform with very low total harmonic distortion, fully complying with ISO 6858 and MIL-STD-704 standards without requiring bulky filters. Originality/value: This study introduces a novel application of an asymmetric cascaded multilevel inverter optimized for 400 Hz aircraft ground operations. The topology achieves significantly higher voltage level density compared with existing structures while eliminating flying capacitors or clamping diodes, thereby reducing hardware complexity, enhancing overall system reliability and providing rigorously validated power quality performance.

  • Open Access

    A Cascaded Asymmetric Multilevel Inverter for Aircraft Ground Power Unit: Design and Implementation

    by Korhan Karaarslan, Ersoy Beser, Mehlika Sengul, Esra Kandemir Beser

    Aircraft ground power units (GPUs) must supply regulated 115 V, 400 Hz power to aircraft systems during ground operations while satisfying strict power quality standards. Conventional GPU architectures commonly rely on two-level inverters with bulky output filters and transformers, increasing complexity and limiting harmonic performance at 400 Hz. This study proposes a single-phase cascaded asymmetric multilevel inverter topology specifically for aircraft ground power applications. The proposed inverter employs binary-scaled DC voltage modules combined with a conventional H-bridge to generate a high number of voltage levels using a reduced switching device. A deterministic switching strategy at low frequency enables staircase voltage synthesis without high-frequency pulse-width modulation. The feasibility of the proposed topology is verified through simulation and experimental studies on a 31-level laboratory prototype. Experimental results demonstrate that the inverter maintains stable voltage regulation under steady-state and dynamic load conditions while producing a high-quality output waveform with low total harmonic distortion. The multilevel voltage synthesis allows the inverter to satisfy aircraft requirements without bulky output filters. Additionally, comparative analysis shows that the proposed topology achieves higher voltage level density than several existing multilevel structures while avoiding flying-capacitors and clamping diodes.

  • A NEW MULTILEVEL INVERTER TOPOLOGY FOR PERMANENT MAGNET SYNCHRONOUS MOTORS

    by Esra Kandemi̇r Beşer, Ersoy Beşer

    Bu çalışmada, Sürekli Mıknatıslı Senkron Motorlarda (SMSM) kullanılabilecek çok seviyeli evirici topolojisi önerilmektedir. Önerilen yapı çok seviyeli gerilim şeklini yapısındaki seviye modülleri ve modüller içerisindeki anahtarlama elemanlarına ait tetikleme sinyalleri ile elde etmektedir. Çıkış gerilimi harmonikleri düşüktür. Bu yüzden bu yapının SMSM gibi giriş akımının saf sinüs olduğu motor uygulamalarında kullanılması oldukça uygundur. Bu üstünlüğü göstermek için önerilen eviricinin SMSM ile birlikte değişken moment ve değişken hız durumları için benzetim çalışması yapılmıştır. Benzetim sonuçlarına göre seviye sayısı arttıkça gerilim ve akım toplam harmonik bozunumu (THB) değerleri azalarak dalga şekilleri daha sinüsoidal hale gelmektedir. Önerilen eviricinin, SMSM sürücüsü olarak değişken yük ve değişken hız uygulamalarında kullanılması oldukça uygundur.

  • A modified line-commutated inverter for grid-connected photovoltaic systems with voltage-based maximum power point tracking method

    by Murat Unlu, Sabri Camur, Ersoy Beser, Birol Arifoglu

    This paper presents a new structure based on a line-commutated inverter (LCI) for photovoltaic (PV) applications. The proposed LCI circuit is able to inject the DC power to the grid at the unity power factor and with reduced harmonic levels. The proposed circuit with voltage-based maximum power point tracking (MPPT) is implemented in grid-connected PV system. The experimental results show that proposed system can extract the maximum power from PV array under varying irradiation levels. Besides, the power factor can be adjusted by modifying firing angle of SCRs. The modified LCI injects sinusoidal currents into the grid, thus the total harmonic distortion (THD) of the grid currents is about 5% or less, which is meet IEEE 1547 grid-connected standard. The results were obtained without any harmonic compensation or filter equipment when compared with the conventional LCI and current source inverter (CSI).

  • Half-bridge Cascaded Multilevel Inverter Based Series Active Power Filter

    by Korhan Karaarslan, Birol Arifoglu, Ersoy Beser, Sabri Camur

    Half-bridge Cascaded Multilevel Inverter Based Series Active Power Filter Active power filter;Half-bridge cascaded;Harmonic compensation;Multilevel inverter;Power quality; A new single phase half-bridge cascaded multilevel inverter based series active power filter (SAPF) is proposed. The main parts of the inverter are presented in detail. With the proposed inverter topology, any compensation voltage reference can be easily obtained. Therefore, the inverter acts as a harmonic source when the reference is a non-sinusoidal signal. A 31-level inverter based SAPF with the proposed topology, is manufactured and the voltage harmonics of the load connected to the point of common coupling (PCC) are compensated. There is no need for a parallel passive filter (PPF) since the main purpose of the paper is to represent the compensation capability of the SAPF without a PPF. It is aimed to compensate the voltage harmonics of the load fed by a non-sinusoidal supply using the proposed inverter. The validity of the proposed inverter based SAPF is verified by simulation as well as experimental study. The system efficiency is also measured in this study. Both simulation and experimental results show that the proposed multilevel inverter is suitable for SAPF applications.


  • A novel 7-level cascaded inverter for series active power filter

    by Korhan Karaarslan, Birol Arifoglu, Ersoy Beser, Sabri Camur

    Harmonic voltage compensation of the load connected to the point of common coupling (PCC) by using a series of active power filter (SAPF) based on a single phase cascaded multilevel inverter is proposed. The proposed multilevel inverter are presented in detail. The inverter has the ability of acting as a harmonic source when the reference is a non-sinusoidal signal. To achieve this, a simple control technique is performed with the proposed inverter. A prototype of 7-level inverter based SAPF is manufactured without using a parallel passive filter (PPF) because it is designed to show SAPF own compensation capacity alone. Filtering ability of the SAPF is shown both in simulation and experimental studies. The validity of the proposed inverter based SAPF is verified by simulation as well as experimental study. The results show that the proposed multi-level inverter is suitable for SAPF applications.

  • Single phase series active power filter based on 15-level cascaded inverter topology

    by Korhan Karaarslan, Birol Arifoglu, Ersoy Beser, Sabri Camur

    A topology of series active power filter (SAPF) based on a single phase half-bridge cascaded multilevel inverter is proposed to compensate voltage harmonics of the load connected to the point of common coupling (PCC). The main parts of the inverter are presented in detail. Any voltage reference can be easily obtained by a simple control with the proposed inverter. Therefore, the inverter acts as a harmonic source when the reference is a non-sinusoidal signal. A prototype of 15-level inverter based SAPF is manufactured without using a parallel passive filter (PPF) as it is intended to represent the compensation capability of the SAPF by itself. The load connected to PCC whose voltage is non-sinusoidal is filtered both in simulation and experimental studies. The validity of the proposed inverter based SAPF is verified by simulation as well as experimental study. Both simulation and experimental results show that the proposed multilevel inverter is suitable for SAPF applications.


  • A new method for tracking the global maximum power point for grid-connected pv system under partially shaded conditions

    by Murat Unlu, Sabri Camur, Ersoy Beser, Birol Arifoglu

    The output power of PV system can drastically decrease when photovoltaic modules under partially shaded condition. Therefore, partially shaded condition is a big issue to proper tracking maximum power point in photovoltaic systems. This paper proposes a new simple method which can track the global maximum power point under this condition. The proposed method is obtained by combining the incremental conductance algorithm and the sweeping p-v curve in the predetermined interval processing. The proposed method is implemented on a single phase grid-connected PV system, and is realized by adjusting the injected current into the grid. The model of proposed system is generated in MATLAB/Simulink. Moreover, an experimental setup is developed to confirm the effectiveness of the proposed system. The obtained simulation and experimental results show that the proposed algorithm can track accurately the global maximum power point of the PV system under uniform insolation and PSC.