    Reinventing Effective Grounding Systems via Optimal Soil Composition, Thickness, and Replacement Parameters Under Fault Conditions

    by Ahmed El-Tayeb Khalil, Adel Zein El Dein, Mahmoud Ramadan Hefny, Matti Lehtonen, Mohamed M. F. Darwish

    This paper investigates the impact of soil replacement around a ground grid on its performance, with a focus on replacing the base soil with a lower-resistivity material and analyzing the influence of the replaced layer’s area and thickness. The study explores the effects of soil replacement on critical parameters such as total ground resistance, earth surface potential (ESP), current density, and electric field distribution under line-to-ground fault conditions. Key soil properties, including water content, thermal and electrical conductivity, heat capacity, density, and relative permittivity coefficient, are also considered to assess their role in optimizing the grounding environment. Despite extensive research on grounding system performance, most existing studies have assumed homogenous soil models or ideal conditions, overlooking the complex variations in real soil properties and environmental factors that critically affect fault performance. Traditional design methodologies often fail to address the effects of non-uniform soil composition, moisture variations, and localized resistivity changes, leading to suboptimal safety and performance in practical installations. This gap necessitated the proposed research, which systematically investigates soil replacement strategies as a practical and scalable solution to enhance grounding system efficiency under realistic conditions. This paper addresses a detailed investigation of how targeted soil replacement strategies influence grounding system behavior under realistic fault conditions. It introduces a practical framework that integrates both environmental and electrical soil properties to enhance performance evaluation and design accuracy. The results demonstrate that replacing high-resistivity sand with low-resistivity clay significantly reduces total ground resistance. For a 1-meter-thick replaced layer, resistance decreased from 8.4 Ω to 3.17 Ω (a 62.3% reduction) when sand was replaced with clay, whereas replacing clay with sand increased resistance to 11.5 Ω (a 37% increase) at 1.5 meters of thickness. Similarly, ESP values dropped substantially when clay was introduced as a replacement layer, enhancing current dissipation and reducing surface potential risks. Moreover, expanding the replaced soil width from 25 meters to 50 meters resulted in further ground resistance reduction, with values decreasing from 3.3 Ω to 3.17 Ω when replacing sand with clay, while resistance increased from 2.5 Ω to 8.4 Ω when replacing clay with sand. The study also revealed that a 50% replacement of sand with clay improved current density uniformity and enhanced grounding efficiency compared to full replacement scenarios. The findings show that replacing the cover soil layer achieves greater improvements in reducing ground resistance and enhancing current dissipation compared to the base layer. Increasing the thickness and area of the replaced soil further improves current density uniformity, reduces surface potential, and significantly boosts the safety and efficiency of grounding systems, especially in high-resistivity soils.


  • Open Access

    Electrical Impedance Spectroscopy: A Complementary Approach Differentiating PID Mechanisms in Photovoltaics

    by A. El-Tayeb, Fang Li, Akash Kumar, Govindasamy Tamizhmani

    Potential-induced degradation (PID) presents a critical reliability issue for solar photovoltaic (PV) modules, with three primary types identified in the literature, namely, PIDs (shunting type), PIDp (polarization type), and PIDc (corrosion type). Electrochemical/electrical impedance spectroscopy (EIS) is a highly effective but underutilized technique for differentiating between these PID mechanisms. When used alongside conventional I–V measurements (e.g., Isc, Voc, and FF), EIS offers direct insights into parameters such as Rs, Rp, and Cp, making it a valuable tool for PID type differentiation. In this study, two four-cell glass–glass modules were investigated using p-base PERC monofacial cells with EVA and POE encapsulants. Results indicate that Voc and FF remained nearly unchanged under +1000 V stress for both EVA and POE modules, suggesting a minimal impact of PID stress on these parameters. However, Isc was reduced by approximately 8.5% in the EVA module and 10% in the POE module. For the POE module, surface recombination (PIDp) is likely responsible for the Isc loss, as Rs, Rp, and Cp showed no significant variation. Conversely, in the EVA module, the combined effects of surface recombination and junction recombination (PIDjr) are the probable cause of the Isc loss, as evidenced by remarkable changes in Rp and Cp. The observed decrease in Rp for the EVA module is attributed to reduced dynamic diode resistance rather than ohmic shunt resistance. This reduction is linked to recombination currents induced by junction trap centers, formed by the positive voltage PID stress in the encapsulant, which contains trace amounts of oxidizable species such as CH3COOH and/or H2O. The objective of this study is to evaluate the impact of PID stress on the electrical characteristics of glass–glass PV modules with different encapsulants, utilizing a combined EIS and I–V approach to distinguish between PID mechanisms. The findings highlight the critical role of the encapsulant type in determining PID susceptibility, with the EVA module exhibiting significant degradation linked to junction recombination losses. These insights underscore the necessity of optimizing encapsulant materials to enhance PV module durability and reliability in real-world applications.


  • Open Access

    Effect of Grid Depth on the Performance of Ground Grid under Influence of Line to Ground Fault

    by Mahmoud R. Hefny, Adel Z. El Dein, A. El-Tayeb

    – There are many factors that affect the grounding process, so adapting these factors helps in achieving the best results for the grounding system. It is important to study some natural properties around the ground grid to create an appropriate environment for the grounding process. This paper aims to study the effect of the grid depth on the performance of the grounding grid with the effect of applying a specific line fault based on the experimental work and using a simulation program based on Finite Element Method (FEM). The effect of the change in the laying depth of the grid was monitored on the total ground resistance, the Earth Surface Potential (ESP), the current density, and the electric field of the ground grid. Also, the following soil properties have been taken into consideration; the water content, the thermal and electrical conductivity, heat capacity, density, and the relative permittivity coefficient of the soil. From the obtained results, it is noticed that by increasing the depth of the grounding grid, a decrease in the total ground resistance was observed, and there is a change in the performance of the ground grid. The findings of this investigation offer priceless insights: as grid depth rises, there is a noticeable decrease in overall ground resistance, indicating improved grounding system performance. Variations in ESP, electric field distribution, and current density further highlight the complex nature of the effects of grid depth.

  • Reaction kinetics studies for phenol degradation under the impact of different gas bubbles and pH using gas–liquid discharge plasma

    by A. El-Tayeb, Takamasa Okumura, Pankaj Attri, Kunihiro Kamataki, Kazunori Koga, Masaharu Shiratani

    A gas–liquid discharge plasma (GLDP) reactor is used to degrade organic pollutants such as phenol. GLDP contains a 7-pin plate system used to enhance phenol degradation in the presence of various pH, and gas bubbles produced from air, O2, O3, CO2, and Ar gases. Experimental outcomes show the impact of solution pH, as phenol degradation efficiencies of 85%, 90%, 96%, and 98% were obtained for pH of 12, 9, 3, and 1, respectively, after 60 min of treatment. This shows that the optimum pH for phenol degradation lies between 1 and 3. Moreover, we explored the influence of gas bubbles generated using various gases, such as air, O2, O3, CO2, and Ar, on phenol degradation. In the presence of O3 gas bubbles, the rate and degree of phenol degradation were significantly increased compared to gas bubbles produced from other gases (O2, CO2, Ar, and air). The degradation competence of phenol by added oxygen remained higher than argon. The performance of the GLDP system at various pH values and gas bubbles was evaluated using kinetic models. Pseudo-zero, first and second reaction kinetics models were used to examine the degradation of phenol. The rate of degradation at different pH and in the presence of gas bubbles follows pseudo-zero-order kinetics. Our GLDP reactor consumed energy of 127.5 J l−1 for phenol degradation under the influence of air bubbles and pH 5. The outcome of this research can help in the design of new reactors for industrial wastewater treatment.


  • Open Access

    Influence of Temperature in Degradation of Organic Pollution Using Corona Discharge Plasma

    by A. El-Tayeb, Adel Z. El-Dein, Ashraf Y. Elnaggar, Enas E. Hussein

    Dye solution temperature influences the elimination efficiency of water-soluble and anionic acid dye. Acid Blue 25 dye, using a gas–liquid electrical discharge system, was successfully investigated. The results showed an increase in the percentage of dye decolorization from 91.16% to 96.12% when the dye solution temperature was increased from 278 K to 308 K. However, the initial dye decolorization percentage was decreased with the further increase in dye solution temperature from 318 K to 358 K. The 2D simulation model was introduced to consider the influence of temperature and the electric field generated by corona discharge plasma in air and water. Results also showed a great match between the experimental and the simulation results. The reaction rates of dye degradation were analyzed using the Arrhenius equation. Furthermore, pseudo-zero-, pseudo-first-, and pseudo-second-order models were used to determine the reaction kinetics. The best fit for the experimental data would follow the pseudo-first-order model. Finally, electrical energy per order, energy yield, and experimental degradation data were calculated to investigate the cost analysis.


  • Open Access

    RETRACTED: Phenol Removal using Corona Discharge Plasma Combined with Porous Polyaniline Nanofiber

    by Ahmed El-Tayeb Khalil, Hussain Noby, Ahmed H Elshazly, Marwa F. Elkady

    The authors have requested that this preprint be removed from Research Square.

  • Open Access

    Investigation the Influence of Different Salts on the Degradation of Organic Dyes Using Non-Thermal Plasma

    by Ahmed El-Tayeb, Ahmed H. El-Shazly, Marwa F. Elkady

    In dye decolorization tests a non-thermal plasma (NTP) corona discharge generated by a high voltage pin-to-ground plate displayed 82% color removal within 11 min. Total color removal was accomplished after 28 min. Different salts such as KCl, NaCl, CaCl2 and AlCl3 were utilized to check the influence of conductivity changes on the dye decolorization process. Higher dye solution conductivity improved the color removal efficiency. The discharge energy and degradation efficiency were computed for diverse concentrations for NaCl, KCl, CaCl2 and AlCl3, whereby it was noticed that the salts generally have a small impact on the level of dye decolorization using corona discharge. In addition, the essential reactive species involved in the oxidation of organic dye compounds such as ozone (O3) generated in treated water and hydrogen peroxide (H2O2) were investigated and the energetic species that produced the non-thermal plasma at the optimum operation time were determined. Energy yields for decolorization and Electrical Energy per Order (EE/O) were calculated for different concentrations of NaCl, KCl, CaCl2 and AlCl3. This work may help in designing plasma systems appropriate for treatment of industrial wastewaters polluted by dyes.


  • Impacts of different salts on the degradation of acid blue 25 dye using non-thermal plasma

    by A. El-Tayeb, A. H. El-Shazly, M. F. Elkady

    The color removal performance using non-thermal plasma system (NTP) corona discharge type generated from high voltage pin-to-ground plate display 82% color clearing at 11min. The total complete color removal was accomplished within 28min. Likewise, various salts as KCl, NaCl, CaCl2 and AlCl3 was used for check the influence of the conductivity. The increasing of conductivity signs that the reduction in color removal efficiency. The discharge energy and degradation competence are computed at diverse concentration for NaCl, KCl, CaCl2 and AlCl3. It was noticed that the salts compact the amount and the level of decolorization. In addition the investigated of the essential reactive species complicated in oxidation of dye organic compounds are O3 in treated water and H2O2. So the measurement for the energetic species that produced throughout the non-thermal plasma at the optimum operation time like hydrogen peroxide (H2O2), and ozone (O3). The benefits from this work in designing the plasma systems appropriate for industrial wastewaters treatment.