Maria Cruz Cardeñosa‐Rubio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maria Cruz Cardeñosa‐Rubio has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Ryan C. Bailey
Department of Chemistry, University of Michigan, Ann Arbor, USA
3 shared publications - Laura M. Lechuga
Nanobiosensors and Bioanalytical Applications Group (NanoB2A), Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, CIBER-BBN, and BIST, Campus UAB Bellaterra, 08193 Barcelona, Spain
2 shared publications - Maria Soler
Nanobiosensors and Bioanalytical Applications Group (NanoB2A), Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, BIST and CIBER-BBN, 08193 Bellaterra, Barcelona, Spain
2 shared publications Richard M. Graybill
Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, USA
2 shared publications- Aida Mayorgas
STAT-Dx Life S.L. (A QIAGEN Company) Baldiri Reixac, 4 Barcelona 08028, Spain
1 shared publication Alejandro Astua
Nanobiosensors and Bioanalytical Applications (NanoB2A), Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, BIST and CIBER-BBN, 08193 Bellaterra, Barcelona, Spain
1 shared publication
Latest Publications
- Open Access
- 6 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (1) , 237-244
Novel Sensing Algorithm for Linear Read-Out of Bimodal Waveguide Interferometric Biosensors
Biosensors employing photonics integrated circuits, and specifically those that rely on interferometric evanescent wave working principles, have outstanding performances due to the extreme sensitivity exhibited in one-step and direct assay, without the need of amplification. Within the interferometric configurations, the Bimodal Waveguide (BiMW) interferometric sensor stands out due to its demonstrated sensitivity for real-life applications and the simplicity of its design. To overcome the ambiguities that arise from the periodic nature of interferometric read-outs, a new all-optical modulation and the subsequent trigonometry-based algorithm have been proposed and applied to the BiMW biosensor. This new algorithm has been successfully employed for the selective identification and quantification of the external Spike (S) protein of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). Our biosensing results from this simple, quick, and user-friendly method demonstrate high sensitivity and specificity and pave the way towards a point-of-care device for general use.
- 6 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 40 (1) , 237-244
Open AccessNovel Sensing Algorithm for Linear Read-Out of Bimodal Waveguide Interferometric Biosensors
Biosensors employing photonics integrated circuits, and specifically those that rely on interferometric evanescent wave working principles, have outstanding performances due to the extreme sensitivity exhibited in one-step and direct assay, without the need of amplification. Within the interferometric configurations, the Bimodal Waveguide (BiMW) interferometric sensor stands out due to its demonstrated sensitivity for real-life applications and the simplicity of its design. To overcome the ambiguities that arise from the periodic nature of interferometric read-outs, a new all-optical modulation and the subsequent trigonometry-based algorithm have been proposed and applied to the BiMW biosensor. This new algorithm has been successfully employed for the selective identification and quantification of the external Spike (S) protein of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). Our biosensing results from this simple, quick, and user-friendly method demonstrate high sensitivity and specificity and pave the way towards a point-of-care device for general use.
- 7 August 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (9) , 2663-2678
How Nanophotonic Label-Free Biosensors Can Contribute to Rapid and Massive Diagnostics of Respiratory Virus Infections: COVID-19 Case
The global sanitary crisis caused by the emergence of the respiratory virus SARS-CoV-2 and COVID-19 outbreak has revealed the urgent need for rapid, accurate, and affordable diagnostic tests to broadly and massively monitor the population in order to properly manage and control the spread of the pandemic. Current diagnostic techniques essentially rely on polymerase chain reaction (PCR) tests, which provide the required sensitivity and specificity. However, its relatively long time-to-result, including sample transport to a specialized laboratory, delays overly the massive detection. Rapid lateral flow tests (both antigen and serological tests) are a remarkable alternative for rapid point-of-care diagnostics, but they exhibit critical limitations as they do not always achieve the required sensitivity for reliable diagnostics and surveillance. Next-generation diagnostic tools capable to overcome all the above limitations are in demand, and optical biosensors are an excellent option to surpass such critical issues. Label-free nanophotonic biosensors offer high sensitivity and operational robustness with an enormous potential for integration in compact autonomous devices to be delivered out-of-the-lab at the point of care (POC). Taking the current COVID-19 pandemic as a critical case scenario, we provide an overview of the diagnostic techniques for respiratory viruses and analyze how nanophotonic biosensors can contribute to improving such diagnostics. We review the ongoing published work using this biosensor technology for intact virus detection, nucleic acid detection or serological tests, and the key factors for bringing nanophotonic POC biosensors to the accurate and effective COVID-19 diagnosis in a short term.
- 7 August 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (9) , 2663-2678
How Nanophotonic Label-Free Biosensors Can Contribute to Rapid and Massive Diagnostics of Respiratory Virus Infections: COVID-19 Case
The global sanitary crisis caused by the emergence of the respiratory virus SARS-CoV-2 and COVID-19 outbreak has revealed the urgent need for rapid, accurate, and affordable diagnostic tests to broadly and massively monitor the population in order to properly manage and control the spread of the pandemic. Current diagnostic techniques essentially rely on polymerase chain reaction (PCR) tests, which provide the required sensitivity and specificity. However, its relatively long time-to-result, including sample transport to a specialized laboratory, delays overly the massive detection. Rapid lateral flow tests (both antigen and serological tests) are a remarkable alternative for rapid point-of-care diagnostics, but they exhibit critical limitations as they do not always achieve the required sensitivity for reliable diagnostics and surveillance. Next-generation diagnostic tools capable to overcome all the above limitations are in demand, and optical biosensors are an excellent option to surpass such critical issues. Label-free nanophotonic biosensors offer high sensitivity and operational robustness with an enormous potential for integration in compact autonomous devices to be delivered out-of-the-lab at the point of care (POC). Taking the current COVID-19 pandemic as a critical case scenario, we provide an overview of the diagnostic techniques for respiratory viruses and analyze how nanophotonic biosensors can contribute to improving such diagnostics. We review the ongoing published work using this biosensor technology for intact virus detection, nucleic acid detection or serological tests, and the key factors for bringing nanophotonic POC biosensors to the accurate and effective COVID-19 diagnosis in a short term.
- 14 September 2019
- Published by Elsevier in Current Opinion in Environmental Science & Health
- Vol. 10, 38-46
Recent advances in environmental and clinical analysis using microring resonator–based sensors
- 14 September 2019
- Published by Elsevier in Current Opinion in Environmental Science & Health
- Vol. 10, 38-46
Recent advances in environmental and clinical analysis using microring resonator–based sensors
- 23 March 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (14) , 1618-1623
Multiplexed microRNA expression profiling by combined asymmetric PCR and label-free detection using silicon photonic sensor arrays
Analysis methods based upon the quantitative, real-time polymerase chain reaction are extremely powerful; however, they face intrinsic limitations in terms of target multiplexing.
- 23 March 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (14) , 1618-1623
Multiplexed microRNA expression profiling by combined asymmetric PCR and label-free detection using silicon photonic sensor arrays
Analysis methods based upon the quantitative, real-time polymerase chain reaction are extremely powerful; however, they face intrinsic limitations in terms of target multiplexing.
- 26 January 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (5) , 1210-1216
Combining asymmetric PCR-based enzymatic amplification with silicon photonic microring resonators for the detection of lncRNAs from low input human RNA samples
A method for quantifying biologically relevant long-non-coding RNAs by combining nucleic acid amplification via asymmetric polymerase chain reaction (PCR) with label-free PCR product detection using silicon photonic microring resonator arrays is described. This approach eliminates the need for fluorophores, which presents a limit for spectral multiplexing in conventional qPCR methods, and rather offers potential for much higher levels of plexity by spatially arraying capture probes. Here, we demonstrate the potential of this technique to detect two differentially expressed lncRNA transcripts and an internal control mRNA transcript in different commercial human tissue specimens, as well as in a glioblastoma cell line using only nanogram input amounts of total RNA. The obtained results were validated using single-plex RT-qPCR and found to be in good agreement, demonstrating the potential of this technique for lncRNA quantification applications.
- 26 January 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (5) , 1210-1216
Combining asymmetric PCR-based enzymatic amplification with silicon photonic microring resonators for the detection of lncRNAs from low input human RNA samples
A method for quantifying biologically relevant long-non-coding RNAs by combining nucleic acid amplification via asymmetric polymerase chain reaction (PCR) with label-free PCR product detection using silicon photonic microring resonator arrays is described. This approach eliminates the need for fluorophores, which presents a limit for spectral multiplexing in conventional qPCR methods, and rather offers potential for much higher levels of plexity by spatially arraying capture probes. Here, we demonstrate the potential of this technique to detect two differentially expressed lncRNA transcripts and an internal control mRNA transcript in different commercial human tissue specimens, as well as in a glioblastoma cell line using only nanogram input amounts of total RNA. The obtained results were validated using single-plex RT-qPCR and found to be in good agreement, demonstrating the potential of this technique for lncRNA quantification applications.
- Open Access
- 27 January 2014
- Published by Wiley in New Phytologist
- Vol. 202 (2) , 716-725
Different outcomes for the MYB floral symmetry genes DIVARICATA and RADIALIS during the evolution of derived actinomorphy in Plantago
Summary: The gene network that specifies flower shape in Antirrhinum majus (bilateral floral symmetry or zygomorphy) includes two MYB‐class genes – RADIALIS (RAD) and DIVARICATA (DIV). RAD is involved in establishing the dorsal identity program and its role is to regulate the domain of activity of DIV (the ventral identity program) by restricting it to ventral regions of the flower. Plantago is in the same family as Antirrhinum but has small, radially symmetrical (actinomorphic) flowers derived from a zygomorphic ancestral state. Here we investigate the MYB‐class floral symmetry genes and the role they have played in the evolution of derived actinomorphy in Plantago lanceolata. A DIV ortholog (PlDIV) but no RAD ortholog was identified in P. lanceolata. PlDIV is expressed across all petals and stamens later in flower development, which is consistent with the loss of RAD gene function. PlDIV expression in anther sporogenous tissue also suggests that PlDIV was co‐opted to regulate cell proliferation during the early stages of pollen development. These results indicate that evolution of derived actinomorphy in Plantago involved complete loss of dorsal gene function, resulting in expansion of the domain of expression of the ventral class of floral symmetry genes.
- 27 January 2014
- Published by Wiley in New Phytologist
- Vol. 202 (2) , 716-725
Open AccessDifferent outcomes for the MYB floral symmetry genes DIVARICATA and RADIALIS during the evolution of derived actinomorphy in Plantago
Summary: The gene network that specifies flower shape in Antirrhinum majus (bilateral floral symmetry or zygomorphy) includes two MYB‐class genes – RADIALIS (RAD) and DIVARICATA (DIV). RAD is involved in establishing the dorsal identity program and its role is to regulate the domain of activity of DIV (the ventral identity program) by restricting it to ventral regions of the flower. Plantago is in the same family as Antirrhinum but has small, radially symmetrical (actinomorphic) flowers derived from a zygomorphic ancestral state. Here we investigate the MYB‐class floral symmetry genes and the role they have played in the evolution of derived actinomorphy in Plantago lanceolata. A DIV ortholog (PlDIV) but no RAD ortholog was identified in P. lanceolata. PlDIV is expressed across all petals and stamens later in flower development, which is consistent with the loss of RAD gene function. PlDIV expression in anther sporogenous tissue also suggests that PlDIV was co‐opted to regulate cell proliferation during the early stages of pollen development. These results indicate that evolution of derived actinomorphy in Plantago involved complete loss of dorsal gene function, resulting in expansion of the domain of expression of the ventral class of floral symmetry genes.