Thomas Sang Hyuk Yoo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas Sang Hyuk Yoo has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Enric Garcia-Caurel
Ecole Polytechnique, LPICM
10 shared publications Razvigor Ossikovski
LPICM, CNRS, École Polytechnique, Univ. Paris-Saclay (France)
5 shared publications- Razvigor Ossikovski
Institut Polytechnique de Paris
4 shared publications - Matthieu Lancry
Institut de Chimie Moléculaire et Des Matériaux d’Orsay (ICMMO), Université Paris-Saclay, 91405 Orsay, France
3 shared publications Andrea Fernández
Univ. de Cantabria (Spain)
2 shared publications- Bertrand Poumellec
Institut de Chimie Moléculaire et des Matériaux d’Orsay, CNRS, Université Paris-Saclay, 91405 Orsay, France
2 shared publications
Latest Publications
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Application d'un imageur polarimétrique multimodal pour l'étude de la réponse optique de milieux et de microstructures diffusantes
Application of a Multimodal Polarimetric Imager to Study the Polarimetric Response of Scattering Media and Microstructures: Les travaux réalisés au cours cette thèse ont eu comme objectif l’étude de l’interaction de la lumière polarisée avec des milieux et des particules diffusants. Ces travaux s’inscrivent dans un contexte collaboratif fort entre le LPICM et différents laboratoires privés et publics. Des aspects très variées ont été traités en profondeur dont le développement instrumental, la simulation numérique avancée et la création de protocoles de mesure pour l’interprétation de donnés à caractère complexe.La partie instrumentale de la thèse a été consacrée au développement d’un instrument novateur, adapté à la prise d’images polarimétriques à différents échelles (du millimètre au micron) pouvant être rapidement reconfigurable pour offrir différents modes d’imagerie du même échantillon. Les deux aspects principaux qui caractérisent l’instrument sont i) la possibilité d’obtenir des images polarimétriques réelles de l’échantillon et des images de la distribution angulaire de lumière diffusé par une zone sur l’échantillon dont sa taille et position peuvent être sélectionnée par l’utilisateur à volonté, ii) le contrôle total de l’état de polarisation, de la taille et de la divergence des faisceaux utilisés pour l’éclairage de l’échantillon et pour la réalisation des images de celui-ci. Ces deux aspects ne se trouvent réunis sur aucun autre appareil commercial ou expérimental actuel.Le premier objet d’étude en utilisant le polarimètre imageur multimodal a été l’étude de l’effet de l’épaisseur d’un milieu diffusant sur sa réponse optique. En imagerie médicale il existe un large consensus sur les avantages de l’utilisation de différentes propriétés polarimétriques pour améliorer l’efficacité de techniques optiques de dépistage de différentes maladies. En dépit de ces avantages, l’interprétation des observables polarimétriques en termes de propriétés physiologiques des tissus se trouve souvent obscurcie par l’influence de l’épaisseur, souvent inconnue, de l’échantillon étudié.L’objectif des travaux a été donc, de mieux comprendre la dépendance des propriétés polarimétriques de différents matériaux diffusants avec l’épaisseur de ceux-ci. En conclusion, il a été possible de montrer que, de manière assez universelle, les propriétés polarimétriques des milieux diffusants varient proportionnellement au chemin optique que la lumière a parcouru à l’intérieur du milieu, tandis que le dégrée de polarisation dépend quadratiquement de ce chemin. Cette découverte a pu être ensuite utilisée pour élaborer une méthode d’analyse de données qui permet de s’affranchir de l’effet des variations d’épaisseur des tissus, rendant ainsi les mesures très robustes et liées uniquement aux propriétés intrinsèques des échantillons étudiés.Un deuxième objet d’étude a été la réponse polarimétrique de particules de taille micrométrique. La sélection des particules étudiées par analogie à la taille des cellules qui forment les tissus biologiques et qui sont responsables de la dispersion de la lumière. Grâce à des mesures polarimétriques, il a été découvert que lorsque les microparticules sont éclairées avec une incidence oblique par rapport à l’axe optique du microscope, celles-ci semblent se comporter comme si elles étaient optiquement actives. D’ailleurs, il a été trouvé que la valeur de cette activité optique apparente dépend de la forme des particules étudiées. L’explication de ce phénomène est basée sur l’apparition d’une phase topologique dans le faisceau de lumière. Cette phase topologique dépend du parcours de la lumière diffusée à l’intérieur du microscope. L’observation inédite de cette phase topologique a été possible grâce au fait que l’imageur polarimétrique multimodale permet un éclairage des échantillons à l’incidence oblique. Cette découverte peut améliorer significativement l’efficacité de méthodes optiques pour la détermination de la forme de micro-objets.
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Application d'un imageur polarimétrique multimodal pour l'étude de la réponse optique de milieux et de microstructures diffusantes
Application of a Multimodal Polarimetric Imager to Study the Polarimetric Response of Scattering Media and Microstructures: Les travaux réalisés au cours cette thèse ont eu comme objectif l’étude de l’interaction de la lumière polarisée avec des milieux et des particules diffusants. Ces travaux s’inscrivent dans un contexte collaboratif fort entre le LPICM et différents laboratoires privés et publics. Des aspects très variées ont été traités en profondeur dont le développement instrumental, la simulation numérique avancée et la création de protocoles de mesure pour l’interprétation de donnés à caractère complexe.La partie instrumentale de la thèse a été consacrée au développement d’un instrument novateur, adapté à la prise d’images polarimétriques à différents échelles (du millimètre au micron) pouvant être rapidement reconfigurable pour offrir différents modes d’imagerie du même échantillon. Les deux aspects principaux qui caractérisent l’instrument sont i) la possibilité d’obtenir des images polarimétriques réelles de l’échantillon et des images de la distribution angulaire de lumière diffusé par une zone sur l’échantillon dont sa taille et position peuvent être sélectionnée par l’utilisateur à volonté, ii) le contrôle total de l’état de polarisation, de la taille et de la divergence des faisceaux utilisés pour l’éclairage de l’échantillon et pour la réalisation des images de celui-ci. Ces deux aspects ne se trouvent réunis sur aucun autre appareil commercial ou expérimental actuel.Le premier objet d’étude en utilisant le polarimètre imageur multimodal a été l’étude de l’effet de l’épaisseur d’un milieu diffusant sur sa réponse optique. En imagerie médicale il existe un large consensus sur les avantages de l’utilisation de différentes propriétés polarimétriques pour améliorer l’efficacité de techniques optiques de dépistage de différentes maladies. En dépit de ces avantages, l’interprétation des observables polarimétriques en termes de propriétés physiologiques des tissus se trouve souvent obscurcie par l’influence de l’épaisseur, souvent inconnue, de l’échantillon étudié.L’objectif des travaux a été donc, de mieux comprendre la dépendance des propriétés polarimétriques de différents matériaux diffusants avec l’épaisseur de ceux-ci. En conclusion, il a été possible de montrer que, de manière assez universelle, les propriétés polarimétriques des milieux diffusants varient proportionnellement au chemin optique que la lumière a parcouru à l’intérieur du milieu, tandis que le dégrée de polarisation dépend quadratiquement de ce chemin. Cette découverte a pu être ensuite utilisée pour élaborer une méthode d’analyse de données qui permet de s’affranchir de l’effet des variations d’épaisseur des tissus, rendant ainsi les mesures très robustes et liées uniquement aux propriétés intrinsèques des échantillons étudiés.Un deuxième objet d’étude a été la réponse polarimétrique de particules de taille micrométrique. La sélection des particules étudiées par analogie à la taille des cellules qui forment les tissus biologiques et qui sont responsables de la dispersion de la lumière. Grâce à des mesures polarimétriques, il a été découvert que lorsque les microparticules sont éclairées avec une incidence oblique par rapport à l’axe optique du microscope, celles-ci semblent se comporter comme si elles étaient optiquement actives. D’ailleurs, il a été trouvé que la valeur de cette activité optique apparente dépend de la forme des particules étudiées. L’explication de ce phénomène est basée sur l’apparition d’une phase topologique dans le faisceau de lumière. Cette phase topologique dépend du parcours de la lumière diffusée à l’intérieur du microscope. L’observation inédite de cette phase topologique a été possible grâce au fait que l’imageur polarimétrique multimodale permet un éclairage des échantillons à l’incidence oblique. Cette découverte peut améliorer significativement l’efficacité de méthodes optiques pour la détermination de la forme de micro-objets.
- 20 November 2019
- Published by Optica Publishing Group in Applied Optics
- Vol. 58 (33) , 9267-9278
Experimental studies of the transmission of light through low-coverage regular or random arrays of silica micropillars supported by a glass substrate
The transmission of light through low-coverage regular and random arrays of glass-supported silica micropillars of diameters 10-40 mu m and height 10 mu m is studied experimentally. Angle-resolved measurements of the transmitted intensity are performed at visible wavelengths by either a goniospectrophotometer or a multimodal imaging (Mueller) polarimetric microscope. It is demonstrated that for the regular arrays, the angle-resolved measurements are capable of resolving many of the densely packed diffraction orders that are expected for periodic structures of lattice constants 20-80 mu m, but they also display features ("halos" and fringes) that are due to the scattering and guiding of light in individual micropillars or in the supporting glass slides. These latter features are also found in angle-resolved measurements on random arrays of micropillars of the same surface coverage. Finally, we perform a comparison of direct measurements of haze in transmission for our patterned glass samples with what can be calculated from the angle-resolved transmitted intensity measurements. Good agreement between the two types of results is found, which testifies to the accuracy of the angle-resolved measurements that we report. (C) 2019 Optical Society of America
- 20 November 2019
- Published by Optica Publishing Group in Applied Optics
- Vol. 58 (33) , 9267-9278
Experimental studies of the transmission of light through low-coverage regular or random arrays of silica micropillars supported by a glass substrate
The transmission of light through low-coverage regular and random arrays of glass-supported silica micropillars of diameters 10-40 mu m and height 10 mu m is studied experimentally. Angle-resolved measurements of the transmitted intensity are performed at visible wavelengths by either a goniospectrophotometer or a multimodal imaging (Mueller) polarimetric microscope. It is demonstrated that for the regular arrays, the angle-resolved measurements are capable of resolving many of the densely packed diffraction orders that are expected for periodic structures of lattice constants 20-80 mu m, but they also display features ("halos" and fringes) that are due to the scattering and guiding of light in individual micropillars or in the supporting glass slides. These latter features are also found in angle-resolved measurements on random arrays of micropillars of the same surface coverage. Finally, we perform a comparison of direct measurements of haze in transmission for our patterned glass samples with what can be calculated from the angle-resolved transmitted intensity measurements. Good agreement between the two types of results is found, which testifies to the accuracy of the angle-resolved measurements that we report. (C) 2019 Optical Society of America
- Open Access
- 25 July 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (07) , 076004-9
Digital histology with Mueller microscopy: how to mitigate an impact of tissue cut thickness fluctuations
Studies of biological tissue with polarized light may bring important information on the tissue’s polarimetric properties, namely, depolarization power, retardance, and dichroism. The evolution of these properties with a disease (e.g., inflammation, degeneration, cancer, etc.) suggests using them as optical markers for diagnostics in clinical settings.1 – 5 However, using these parameters for diagnostics requires (i) understanding the fundamental processes of interaction of polarized light with tissue and (ii) finding the optimal set of optical parameters, which will increase the accuracy of diagnostics.
- 25 July 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (07) , 076004-9
Open AccessDigital histology with Mueller microscopy: how to mitigate an impact of tissue cut thickness fluctuations
Studies of biological tissue with polarized light may bring important information on the tissue’s polarimetric properties, namely, depolarization power, retardance, and dichroism. The evolution of these properties with a disease (e.g., inflammation, degeneration, cancer, etc.) suggests using them as optical markers for diagnostics in clinical settings.1 – 5 However, using these parameters for diagnostics requires (i) understanding the fundamental processes of interaction of polarized light with tissue and (ii) finding the optimal set of optical parameters, which will increase the accuracy of diagnostics.
- Open Access
- 18 March 2019
- Published by Optica Publishing Group in OSA Continuum
- Vol. 2 (4) , 1233-1241
Spectral dependence of femtosecond laser induced circular optical properties in silica
Transmission Mueller-matrix spectroscopic ellipsometry is applied to study femtosecond laser induced nanogratings in silica glass in a wide spectral range 250–1800 nm. By using differential decomposition of the Mueller matrix, the circular birefringence and dichroism of femtosecond laser irradiated SiO2 are quantified for the first time in the UV and near-IR range. A maximum value of the effective specific rotation of α ∼ −860°/mm at 290 nm is found. In the near-IR range, we found a linear and circular dichroism band peaking around 1240 nm, which might be attributed to the formation of anisotropic species like the formation of oriented OH species and Si-O-Si bond.
- 18 March 2019
- Published by Optica Publishing Group in OSA Continuum
- Vol. 2 (4) , 1233-1241
Open AccessSpectral dependence of femtosecond laser induced circular optical properties in silica
Transmission Mueller-matrix spectroscopic ellipsometry is applied to study femtosecond laser induced nanogratings in silica glass in a wide spectral range 250–1800 nm. By using differential decomposition of the Mueller matrix, the circular birefringence and dichroism of femtosecond laser irradiated SiO2 are quantified for the first time in the UV and near-IR range. A maximum value of the effective specific rotation of α ∼ −860°/mm at 290 nm is found. In the near-IR range, we found a linear and circular dichroism band peaking around 1240 nm, which might be attributed to the formation of anisotropic species like the formation of oriented OH species and Si-O-Si bond.
- 19 September 2018
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 5 (10) , 4068-4073
Circularly Polarized Images with Contrast Reversal Using Pseudochiral Metasurfaces
- 19 September 2018
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 5 (10) , 4068-4073
Circularly Polarized Images with Contrast Reversal Using Pseudochiral Metasurfaces
- 24 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10678, 20
Multimodal imaging Mueller polarimetric microscope to study polarimetric properties of spheroidal microparticles
We present a multimodal imaging microscope combined with a Muller polarimeter. The multimodal imaging microscope works in both real and Fourier (back-focal) planes. The Fourier plane allows the study of the angular distribution of light scattered or transmitted by the studied sample, whereas the real plane provides an image of the sample, thus allowing the study of the spatial distribution created by the latter one. A Mueller polarimeter provides a complete description of the polarimetric response of the sample. In this paper, we describe the technical characteristics of the multimodal imaging Mueller polarimetric microscope, and we provide an example of the application consisting of the characterization of the polarization of the light scattered by spheroidal microparticles which are made of transparent polymer beads deposited on a glass substrate. A thermal treatment allows transforming the beads from their original spherical shape to those of prolate spheroids. We analyze the modification of the optical response of the particles as a function of their different shape. The experimental results are complemented by numerical simulations based on the Finite-Difference Time- Domain (FDTD) method.
- 24 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10678, 20
Multimodal imaging Mueller polarimetric microscope to study polarimetric properties of spheroidal microparticles
We present a multimodal imaging microscope combined with a Muller polarimeter. The multimodal imaging microscope works in both real and Fourier (back-focal) planes. The Fourier plane allows the study of the angular distribution of light scattered or transmitted by the studied sample, whereas the real plane provides an image of the sample, thus allowing the study of the spatial distribution created by the latter one. A Mueller polarimeter provides a complete description of the polarimetric response of the sample. In this paper, we describe the technical characteristics of the multimodal imaging Mueller polarimetric microscope, and we provide an example of the application consisting of the characterization of the polarization of the light scattered by spheroidal microparticles which are made of transparent polymer beads deposited on a glass substrate. A thermal treatment allows transforming the beads from their original spherical shape to those of prolate spheroids. We analyze the modification of the optical response of the particles as a function of their different shape. The experimental results are complemented by numerical simulations based on the Finite-Difference Time- Domain (FDTD) method.
- 24 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10677, 1067718
Mueller microscopy of anisotropic scattering media: theory and experiments
The combined approach including experiments (Mueller polarimetry) and theory (differential Mueller matrix formalism) for the studies of anisotropic scattering media was tested on the model system of human skin. Custom-build Mueller polarimetric microscope was used for the studies of histological cuts of full-thickness skin equivalents generated from epidermal keratinocytes forming a multilayered epidermis on top of collagen I hydrogel with dermal fibroblasts. The sets of fixed unstained tissue cuts of different thicknesses (5μm - 30μm) were measured in transmission configuration. The values of polarimetric (dichroism and retardance) and depolarization parameters were calculated by applying pixel-wise the logarithmic decomposition of Mueller matrices. The parabolic dependence of depolarization parameters and linear dependence of polarimetric parameters on thickness, as predicted by theory, was confirmed by measurements. It proves that phenomenological modeling of complex anisotropic scattering medium (e.g., biological tissue) may effectively disentangle the polarimetric and depolarizing properties of the system understudies and may be used for analysis and diagnostics of tissue.
- 24 May 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10677, 1067718
Mueller microscopy of anisotropic scattering media: theory and experiments
The combined approach including experiments (Mueller polarimetry) and theory (differential Mueller matrix formalism) for the studies of anisotropic scattering media was tested on the model system of human skin. Custom-build Mueller polarimetric microscope was used for the studies of histological cuts of full-thickness skin equivalents generated from epidermal keratinocytes forming a multilayered epidermis on top of collagen I hydrogel with dermal fibroblasts. The sets of fixed unstained tissue cuts of different thicknesses (5μm - 30μm) were measured in transmission configuration. The values of polarimetric (dichroism and retardance) and depolarization parameters were calculated by applying pixel-wise the logarithmic decomposition of Mueller matrices. The parabolic dependence of depolarization parameters and linear dependence of polarimetric parameters on thickness, as predicted by theory, was confirmed by measurements. It proves that phenomenological modeling of complex anisotropic scattering medium (e.g., biological tissue) may effectively disentangle the polarimetric and depolarizing properties of the system understudies and may be used for analysis and diagnostics of tissue.
- 1 January 2018
- Published by Optica Publishing Group
- p. JW4A.27
Multimodal imaging Mueller polarimetric microscope on geometrical analysis of spherical microparticles
We developed a multimodal imaging polarimetric microscope which images both in Fourier (back-focal) and real planes. We propose an application to study spherical microparticles showing size and shape dependent polarimetric properties.
- 1 January 2018
- Published by Optica Publishing Group
- p. JW4A.27
Multimodal imaging Mueller polarimetric microscope on geometrical analysis of spherical microparticles
We developed a multimodal imaging polarimetric microscope which images both in Fourier (back-focal) and real planes. We propose an application to study spherical microparticles showing size and shape dependent polarimetric properties.