Romina Canales
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Romina Canales has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Soledad Cerutti
Instituto de Química de San Luis (Consejo Nacional de Investigaciones Científicas y Técnicas), Laboratorio de Espectrometría de Masas, Área de Química Analítica, Facultad de Química Bioquímica y Farmacia, Universidad Nacional de San Luis, Bloque III, Ejército de los Andes 950, San Luis CP 5700, Argentina
4 shared publications Mario Reta
Laboratorio de Investigación y Desarrollo de Métodos Analíticos (LIDMA)
3 shared publications- María Guiñez
Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2290, Buenos Aires CP 1425, Argentina
3 shared publications Darío Gómez
Comisión Nacional de Energía Atómica (CNEA), Gerencia Química, Av. Gral. Paz 1499, B1650KNA-San Martín, Pcia., Buenos Aires, Argentina
2 shared publicationsCarolina Talio
Instituto de Química de San Luis (CCT-San Luis), Laboratorio de Espectrometría de Masas, Bloque III, Ejército de Los Andes 950, San Luis, CP5700, Argentina
1 shared publicationCristian Bazán
Instituto de Química de San Luis, Consejo Nacional de Investigaciones Científicas y Técnicas-Universidad Nacional de San Luis, Facultad de Química, Bioquímica y Farmacia Bloque III, Avda. Ejército de los Andes 950, San Luis CP: 5700, Argentina
1 shared publication
Latest Publications
- 18 February 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (11) , 1504-1513
Multi-response optimization of a green solid-phase extraction for the analysis of heterocyclic aromatic amines in environmental samples
Herein, a method for the multi-response optimization of a green and efficient solid phase extraction (SPE) sample treatment using non-modified multi-walled carbon nanotubes combined with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed for the quantification of ten heterocyclic aromatic amines (HAAs) in river and reservoir surface water samples. The proposed methodology was evaluated by employing experimental designs, which made the approach green. Ultra-trace amounts of HAAs were retained in the SPE cartridge. Then, the analytes were removed from the carbon nanotubes with 0.8 mL of a mixture of acetonitrile/water with 0.1% of formic acid. Under the optimal conditions, linearity was achieved for concentration levels ranging from 0.20 μg L−1 to 500 μg L−1, with regression coefficients (R2) in the range of 0.990 to 0.998. Limits of detection varying from 0.06 μg L−1 and 0.23 μg L−1 were attained, the relative standard deviations (n = 3) varied from 1.7 to 6.4, and the extraction recoveries ranged from 90.6% to 106.0% for all the analytes. The results of the presence of HAAs found in the river samples demonstrated levels ranging from 0.16 μg L−1 to 0.53 μg L−1; meanwhile, in the reservoir samples, the levels were higher, ranging from 0.37 μg L−1 to 0.93 μg L−1. Finally, a comparative discussion was applied to assess the greenness of approaches for the determination of heterocyclic aromatic amines in surface water using the available metrics.
- 18 February 2020
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 12 (11) , 1504-1513
Multi-response optimization of a green solid-phase extraction for the analysis of heterocyclic aromatic amines in environmental samples
Herein, a method for the multi-response optimization of a green and efficient solid phase extraction (SPE) sample treatment using non-modified multi-walled carbon nanotubes combined with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was developed for the quantification of ten heterocyclic aromatic amines (HAAs) in river and reservoir surface water samples. The proposed methodology was evaluated by employing experimental designs, which made the approach green. Ultra-trace amounts of HAAs were retained in the SPE cartridge. Then, the analytes were removed from the carbon nanotubes with 0.8 mL of a mixture of acetonitrile/water with 0.1% of formic acid. Under the optimal conditions, linearity was achieved for concentration levels ranging from 0.20 μg L−1 to 500 μg L−1, with regression coefficients (R2) in the range of 0.990 to 0.998. Limits of detection varying from 0.06 μg L−1 and 0.23 μg L−1 were attained, the relative standard deviations (n = 3) varied from 1.7 to 6.4, and the extraction recoveries ranged from 90.6% to 106.0% for all the analytes. The results of the presence of HAAs found in the river samples demonstrated levels ranging from 0.16 μg L−1 to 0.53 μg L−1; meanwhile, in the reservoir samples, the levels were higher, ranging from 0.37 μg L−1 to 0.93 μg L−1. Finally, a comparative discussion was applied to assess the greenness of approaches for the determination of heterocyclic aromatic amines in surface water using the available metrics.
- 2 February 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (8) , 910-919
Solvent-based de-emulsification dispersive liquid–liquid microextraction coupled with UPLC-MS/MS for the fast determination of ultratrace levels of nitrated and oxygenated polycyclic aromatic hydrocarbons in environmental samples
In this study, a new solvent-based de-emulsification dispersive liquid–liquid microextraction strategy followed by liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry has been developed for the determination of the ultratrace levels of nitrated and oxygenated polycyclic aromatic hydrocarbons present in environmental samples. Various parameters affecting the extraction efficiency such as type and volume of the extraction, dispersive and de-emulsifier solvents, temperature, salt addition, extraction time and sample volume were evaluated. Under optimal conditions, calibration plots were linear in the ranges between 0.005 ng mL−1 and 100 ng mL−1, with correlation coefficients (r2) better than 0.995. In addition, satisfactory extraction recoveries ranging from 95.1% to 98.5% were obtained. The proposed method has been found to have excellent detection sensitivity with limits of detection (LODs, S/N = 3) of 8.9–89.0 ng L−1 and precisions of 1.4–8.7% (RSDs, n = 5). Enrichment factors of the four target compounds were from 191-folds to 200-folds. The proposed method may be advised as an economical, fast easy, sensitive, accurate approach, even better than conventional DLLME and similar techniques. The results indicated that this methodology was suitable for the analysis of ultratraces of nitrated and oxygenated PAHs in water samples.
- 2 February 2018
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (8) , 910-919
Solvent-based de-emulsification dispersive liquid–liquid microextraction coupled with UPLC-MS/MS for the fast determination of ultratrace levels of nitrated and oxygenated polycyclic aromatic hydrocarbons in environmental samples
In this study, a new solvent-based de-emulsification dispersive liquid–liquid microextraction strategy followed by liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry has been developed for the determination of the ultratrace levels of nitrated and oxygenated polycyclic aromatic hydrocarbons present in environmental samples. Various parameters affecting the extraction efficiency such as type and volume of the extraction, dispersive and de-emulsifier solvents, temperature, salt addition, extraction time and sample volume were evaluated. Under optimal conditions, calibration plots were linear in the ranges between 0.005 ng mL−1 and 100 ng mL−1, with correlation coefficients (r2) better than 0.995. In addition, satisfactory extraction recoveries ranging from 95.1% to 98.5% were obtained. The proposed method has been found to have excellent detection sensitivity with limits of detection (LODs, S/N = 3) of 8.9–89.0 ng L−1 and precisions of 1.4–8.7% (RSDs, n = 5). Enrichment factors of the four target compounds were from 191-folds to 200-folds. The proposed method may be advised as an economical, fast easy, sensitive, accurate approach, even better than conventional DLLME and similar techniques. The results indicated that this methodology was suitable for the analysis of ultratraces of nitrated and oxygenated PAHs in water samples.